July 04, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner archive status: no full plan_journal planning cycles were recorded on 2026-07-04.

Delivery events

11

Required cycles pending

0

One-shot corrections

5

The planner did write one-shot setpoint corrections on 2026-07-04 (iris-oneshot-20260704-0022, iris-oneshot-20260704-0539, iris-oneshot-20260704-1307, iris-oneshot-20260704-1509, iris-oneshot-20260704-2038), but those are not counted as full daily planning cycles.

EventTypeStatusDeliveredNote
End-of-day review and reset (catch-up)MIDNIGHTplan_written2026-07-04 00:20Delivered 2026-07-04 00:20; resulting plan iris-oneshot-20260704-0022.
Morning planning cycleSUNRISEplan_written2026-07-04 05:37Delivered 2026-07-04 05:37; resulting plan iris-oneshot-20260704-0539.
Forecast deviationFORECAST_DEVIATIONacked2026-07-04 12:30Delivered 2026-07-04 12:30; resulting plan -. Acknowledged: FORECAST_DEVIATION no tunable change: observed solar is far below forecast, matching known positive solar forecast bias/nowcast error rather than a live control miss. Current climate is inside bands (81.7F vs temp_high 83.2, VPD 1.04 vs vpd_high 1.21, dew margin 9...
Solar peak planning checkpointSOLAR_MAXplan_written2026-07-04 13:07Delivered 2026-07-04 13:07; resulting plan iris-oneshot-20260704-1307.
Peak StressTRANSITIONplan_written2026-07-04 15:09Delivered 2026-07-04 15:09; resulting plan iris-oneshot-20260704-1509.
Forecast deviationFORECAST_DEVIATIONacked2026-07-04 16:28Delivered 2026-07-04 16:28; resulting plan -. Acknowledged: No tunable change: observed VPD is lower than raw forecast in the same direction as known positive VPD forecast bias; live climate is near the band with safe dew margin and equipment is idle, while current hot-dry posture is already at the aggressive moisture/fog limits.
Forecast deviationFORECAST_DEVIATIONacked2026-07-04 18:50Delivered 2026-07-04 18:50; resulting plan -. Acknowledged: FORECAST_DEVIATION assessed as known forecast VPD overshoot/catch-up, not a live equipment or weather regime change. Live climate is 82.1F, VPD 1.19 kPa, RH 69%, dew margin 11.5F, mode IDLE; equipment is off and setpoints already hold aggressive hot-dry moisture posture (fog_escalation_kpa 0...
DeclineTRANSITIONacked2026-07-04 19:38Delivered 2026-07-04 19:38; resulting plan -. Acknowledged: Decline transition checked live climate/equipment/plan/setpoints. Current house is still VPD-high (avg 1.32 kPa vs vpd_high 1.00) with healthy dew margin 13.5F, no VPD-low signal, mode IDLE, and all wet/cooling equipment off...
Forecast deviationFORECAST_DEVIATIONacked2026-07-04 19:54Delivered 2026-07-04 19:54; resulting plan -. Acknowledged: FORECAST_DEVIATION assessed: observed VPD is lower/more humid than forecast in the same direction as the established Open-Meteo VPD positive bias; live greenhouse is safe with temp 79.8F, VPD 1.12 kPa, dew margin 11.1F, IDLE/all equipment off, and current moisture posture already at aggressive limits...
Evening planning cycleSUNSETplan_written2026-07-04 20:37Delivered 2026-07-04 20:37; resulting plan iris-oneshot-20260704-2038.
Forecast deviationFORECAST_DEVIATIONacked2026-07-04 20:59Delivered 2026-07-04 20:59; resulting plan -. Acknowledged: FORECAST_DEVIATION assessed with live climate/equipment: observed conditions are cooler and more humid than raw forecast in the same direction as recent forecast positive VPD/temperature overshoot bias; forecast is fresh, equipment is idle/off as expected, dew margin is safe, and current hot-dry moisture...

End-of-Day Summary

Climate

Temperature

66.5–86.2°F; avg 76.0°F

VPD

0.61–2.13 kPa; avg 1.04 kPa

Relative humidity

47.7–75.5%

Stress Hours

  • Heat stress (>85°F): 0.8h
  • VPD stress (>2.0 kPa): 13.4h
  • Cold stress (<55°F): 0.0h

Economics

Electric

USD 1.46

Gas

USD 0.00

Water

USD 0.830

Total

USD 2.29

Equipment Runtimes

EquipmentRuntimeReading
Fan 1148 minPrimary exhaust runtime.
Fan 2142 minSecondary exhaust runtime.
Vent196 minIntake vent runtime.
Fog148 minFogger runtime.
Heat 1 electric9 minElectric heater runtime.
Heat 2 gas0 minGas heater runtime.
Grow lights698 minSupplemental lighting runtime.
Mister south0.99hSouth mister runtime.
Mister west0.18hWest mister runtime.
Mister center0.69hCenter mister runtime.

Water

  • Total: 171 gal
  • Mister: 107 gal

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Cannabissouth70%1Observation notes are collapsed below to avoid publishing partial vision snippets.
Lime Treewest80%1Observation notes are collapsed below to avoid publishing partial vision snippets.
Vanda Orchidscenter80%1Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
CannabisGemini Vision notes

[potential drought stress] Plants look generally healthy but soil moisture is reported at 0.0%, which could lead to stress if not addressed.

Lime TreeGemini Vision notes

Lime tree appears healthy with adequate soil moisture.

Vanda OrchidsGemini Vision notes

Orchids hanging in the center appear healthy with no visible signs of stress.

Hourly Pattern

HourTemperatureVPDRH
12:0081.1°F1.14 kPa69.0%
13:0082.2°F1.29 kPa66.8%
14:0083.2°F1.35 kPa67.0%
15:0083.8°F1.36 kPa67.6%
16:0083.5°F1.25 kPa69.1%
17:0082.2°F1.07 kPa72.5%
18:0081.8°F1.13 kPa70.9%
19:0081.3°F1.14 kPa69.6%
20:0079.5°F1.02 kPa71.0%
21:0077.0°F0.81 kPa74.5%
22:0074.5°F0.84 kPa71.4%
23:0073.2°F0.78 kPa72.1%
00:0071.2°F0.88 kPa66.2%
01:0069.0°F0.97 kPa60.1%
02:0068.8°F0.81 kPa66.5%
03:0067.8°F0.77 kPa67.0%
04:0067.8°F0.66 kPa71.6%
05:0066.9°F0.67 kPa70.2%
06:0068.2°F0.68 kPa71.6%
07:0070.2°F0.72 kPa71.9%
08:0072.6°F0.79 kPa71.5%
09:0075.7°F0.96 kPa68.9%
10:0079.2°F1.12 kPa67.6%
11:0080.5°F1.16 kPa68.1%

7-Day Stress Context

DateHeatVPD highCold
2026-06-280.2h9.9h0.0h
2026-06-290.2h11.9h0.0h
2026-06-300.0h7.4h0.0h
2026-07-010.3h8.5h0.0h
2026-07-020.1h10.7h0.0h
2026-07-030.0h10.8h0.0h
2026-07-040.8h13.4h0.0h