July 05, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner archive status: no full plan_journal planning cycles were recorded on 2026-07-05.

Delivery events

7

Required cycles pending

0

One-shot corrections

3

The planner did write one-shot setpoint corrections on 2026-07-05 (iris-oneshot-20260705-0021, iris-oneshot-20260705-0540, iris-oneshot-20260705-2035), but those are not counted as full daily planning cycles.

EventTypeStatusDeliveredNote
End-of-day review and resetMIDNIGHTplan_written2026-07-05 00:19Delivered 2026-07-05 00:19; resulting plan iris-oneshot-20260705-0021.
Morning planning cycleSUNRISEplan_written2026-07-05 05:38Delivered 2026-07-05 05:38; resulting plan iris-oneshot-20260705-0540.
Solar peak planning checkpointSOLAR_MAXacked2026-07-05 13:09Delivered 2026-07-05 13:09; resulting plan -. Acknowledged: SOLAR_MAX reviewed: live solar 1053 W/m2 is above the near-term forecast, but house is still inside served bands at 82.9F vs temp_high 83.8 and VPD 1.10 vs vpd_high 1.22 with dew margin 10F. Current hot-dry posture is already at or near the aggressive floor: fog_escalation_kpa 0...
Peak StressTRANSITIONacked2026-07-05 15:05Delivered 2026-07-05 15:05; resulting plan -. Acknowledged: Peak-stress transition checked live climate/equipment, active plan, and setpoints. House is in VENTILATE at 84.6F with VPD 1.39 kPa vs high 1.20 and safe dew margin 11.6F; wet assist is currently active (fog on, center mister on, vent/fan2 on)...
DeclineTRANSITIONacked2026-07-05 19:34Delivered 2026-07-05 19:34; resulting plan -. Acknowledged: TRANSITION decline reviewed live climate/equipment/plan/setpoints. Current temp is inside band (82.6F vs temp_high 83.4F) but VPD remains slightly above high (1.10 kPa vs vpd_high 1.00) with safe dew margin (10...
Forecast deviationFORECAST_DEVIATIONacked2026-07-05 19:35Delivered 2026-07-05 19:35; resulting plan -. Acknowledged: FORECAST_DEVIATION no tuning: observed VPD is lower than raw forecast in the same direction as the known positive VPD forecast bias; live house is stable at 82.5F, VPD 1.10 kPa, dew margin 10.0F, controller IDLE with relays off...
Evening planning cycleSUNSETplan_written2026-07-05 20:33Delivered 2026-07-05 20:33; resulting plan iris-oneshot-20260705-2035.

End-of-Day Summary

Climate

Temperature

65.6–87.0°F; avg 76.3°F

VPD

0.61–2.01 kPa; avg 1.06 kPa

Relative humidity

50.2–79.5%

Stress Hours

  • Heat stress (>85°F): 1.9h
  • VPD stress (>2.0 kPa): 11.8h
  • Cold stress (<55°F): 0.0h

Economics

Electric

USD 1.57

Gas

USD 0.00

Water

USD 1.890

Total

USD 3.46

Equipment Runtimes

EquipmentRuntimeReading
Fan 1326 minPrimary exhaust runtime.
Fan 2323 minSecondary exhaust runtime.
Vent460 minIntake vent runtime.
Fog258 minFogger runtime.
Heat 1 electric25 minElectric heater runtime.
Heat 2 gas0 minGas heater runtime.
Grow lights469 minSupplemental lighting runtime.
Mister south1.59hSouth mister runtime.
Mister west0.24hWest mister runtime.
Mister center1.48hCenter mister runtime.

Water

  • Total: 391 gal
  • Mister: 391 gal

Hourly Pattern

HourTemperatureVPDRH
12:0081.6°F1.15 kPa70.0%
13:0083.0°F1.33 kPa67.8%
14:0084.2°F1.42 kPa66.7%
15:0083.9°F1.36 kPa67.8%
16:0084.0°F1.37 kPa67.1%
17:0083.3°F1.32 kPa67.0%
18:0082.9°F1.23 kPa68.8%
19:0080.4°F1.19 kPa67.0%
20:0079.0°F1.16 kPa66.1%
21:0076.4°F1.10 kPa64.8%
22:0074.6°F1.08 kPa63.5%
23:0073.4°F0.98 kPa65.3%
00:0071.2°F1.11 kPa57.5%
01:0069.0°F1.11 kPa54.2%
02:0068.0°F1.00 kPa57.5%
03:0068.0°F0.76 kPa67.9%
04:0067.5°F0.66 kPa71.2%
05:0066.6°F0.69 kPa69.0%
06:0067.9°F0.76 kPa67.8%
07:0069.9°F0.76 kPa69.8%
08:0071.8°F0.80 kPa70.3%
09:0075.1°F0.96 kPa68.3%
10:0078.7°F1.12 kPa67.2%
11:0080.8°F1.14 kPa68.8%

7-Day Stress Context

DateHeatVPD highCold
2026-06-290.2h11.9h0.0h
2026-06-300.0h7.4h0.0h
2026-07-010.3h8.5h0.0h
2026-07-020.1h10.7h0.0h
2026-07-030.0h10.8h0.0h
2026-07-040.8h13.4h0.0h
2026-07-051.9h11.8h0.0h