September 01, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
6
3
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:17 | MIDNIGHT | plan_written | Wrote public plan iris-20260901-0017. Resolved 00:19 MDT. |
| Morning planning cycle | 06:30 | SUNRISE | plan_written | Wrote public plan iris-20260901-0630. Resolved 06:32 MDT. |
| Solar peak planning checkpoint | 13:02 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 13:03 MDT. |
| Peak Stress | 15:02 | TRANSITION | acked | Acknowledged: Peak stress is tracking the active posture: 83.6F, VPD 1.28 kPa, dew margin 11.9F, IDLE, all actuators off; no escalation warranted. Resolved 15:04 MDT. |
| Decline | 18:33 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 18:34 MDT. |
| Evening planning cycle | 19:33 | SUNSET | plan_written | Wrote public plan iris-20260901-1933. Resolved 19:35 MDT. |
🌅 Morning Cycle (12:19 AM) — iris-20260901-0017
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20260831-0628
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:89,“outdoor_rh_min_pct”:17,“solar_peak_w_m2”:612,“cloud_cover_avg_pct”:99,“notes”:“Hot-dry overcast day; corrected VPD peaks near 2.9 kPa. Prior bridge scored 3 vs anchor 1 because I overvalued safety while corridor compliance was 43.4% and 87 guardrails held vs 3 dispatched. Retrieval failed for missing OPENAI_API_KEY; use live MCP evidence and validated hot-dry lessons.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-08-31T10:30:00-06:00”,“end”:“2026-08-31T21:30:00-06:00”,“severity”:“high”,“mitigation”:“Band-coupled +0.05/+0.20-0.25 wet assist, 30-35% duty, 0.15 fog at peak, 300-gal cap.”},{“kind”:“heat”,“start”:“2026-08-31T11:30:00-06:00”,“end”:“2026-08-31T18:30:00-06:00”,“severity”:“high”,“mitigation”:“Use 45-60 min thermal lead and up to 2F precooling; accept physically limited residual heat… Result: Window 00:17-06:32 MDT: score 75.7, temp compliance 65.9%, VPD compliance 71.8%, total stress 1.13h (0 cold, 0.23 VPD-high), no VPD-low or dew-risk hours. Safety held, but corridor performance was only moderate; resource/cost metrics were unavailable, so efficiency was not gradeable. The planned dry-then-precondition posture was partly effective but did not eliminate temperature/VPD edge misses. Score: 6/10
Hypothesis
Testing: Use measured VPD to switch from drying to band-coupled assist at the high edge during the 09:00-10:00 ramp. Expected outcome: Keep overnight VPD-low and dew-risk at 0h; reduce controller-attributable VPD-high exposure during 10:00-15:00 without chasing in-band target deviation.
Setpoints
Tuesday September 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:17 | hyst 0.21750000000000003 | House is too wet at VPD 0.50; dry safely with no wet assist |
| 04:30 | hyst 0.21750000000000003 | Humid pre-dawn forecast favors dehumidification and stable d |
| 06:00 | hyst 0.1975 | At sunrise, hold off below-edge wetting but stage modest ass |
| 09:30 | hyst 0.1975 | Early dry ramp needs pre-cooling and strong band-coupled wet |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:17 | s2 2.055; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.112; all 1.212; pulse 30; gap 60; wt 1.1 | House is too wet at VPD 0.50; dry safely with no wet assist |
| 04:30 | s2 2.04; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.062; all 1.162; pulse 30; gap 60; wt 1.1333333333333333 | Humid pre-dawn forecast favors dehumidification and stable d |
| 06:00 | s2 1.73; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.862; all 1.012; pulse 30; gap 41.25; wt 1.5333333333333332 | At sunrise, hold off below-edge wetting but stage modest ass |
| 09:30 | s2 1.5250000000000001; cool_exit 1.78; all_fans 1; dw_stress 1; engage 0.812; all 1.012; pulse 41.25; gap 33.75; wt 1.7333333333333334 | Early dry ramp needs pre-cooling and strong band-coupled wet |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:17 | band_track_fraction | initial 0 |
| 00:17 | cold_vent_guard_delta_f | initial 11 |
| 00:17 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:17 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 00:17 | direct_wet_stress_vpd_margin_kpa | initial 0.35 |
| 00:17 | dwell_gate_ms | initial 300000 |
| 00:17 | enthalpy_close | initial 1 |
| 00:17 | enthalpy_open | initial -2 |
| 00:17 | fog_escalation_kpa | initial 0.5 |
| 00:17 | heat_hysteresis | initial 1 |
| 00:17 | min_fog_off_s | initial 132 |
| 00:17 | min_fog_on_s | initial 36.75 |
| 00:17 | mist_backoff_s | initial 600 |
| 00:17 | mist_max_closed_vent_s | initial 600 |
| 00:17 | mist_thermal_relief_s | initial 90 |
| 00:17 | mister_all_delay_s | initial 102 |
| 00:17 | mister_engage_delay_s | initial 51 |
| 00:17 | mister_water_budget_gal | initial 300 |
| 00:17 | night_vpd_bias_kpa | initial 0 |
| 00:17 | outdoor_staleness_max_s | initial 600 |
| 00:17 | sw_dwell_gate_enabled | initial 1 |
| 00:17 | sw_fog_closes_vent | initial 1 |
| 00:17 | sw_mister_closes_vent | initial 0 |
| 00:17 | sw_summer_vent_enabled | initial 1 |
| 00:17 | temp_hysteresis | initial 2.14 |
| 00:17 | vent_exchange_fraction | initial 0.3 |
| 00:17 | vent_prefer_dp_delta_f | initial 6 |
| 00:17 | vent_prefer_temp_delta_f | initial 7 |
| 00:17 | vpd_watch_dwell_s | initial 75 |
| 04:30 | direct_wet_stress_vpd_margin_kpa | 0.35 → 0.3 |
| 04:30 | min_fog_off_s | 132 → 126 |
| 04:30 | min_fog_on_s | 36.75 → 39 |
| 06:00 | cold_vent_guard_delta_f | 11 → 9 |
| 06:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 06:00 | direct_wet_stress_vpd_margin_kpa | 0.3 → 0.1 |
| 06:00 | dwell_gate_ms | 300000 → 240000 |
| 06:00 | fog_escalation_kpa | 0.5 → 0.25 |
| 06:00 | min_fog_off_s | 126 → 72 |
| 06:00 | min_fog_on_s | 39 → 59.25 |
| 06:00 | mister_all_delay_s | 102 → 84 |
| 06:00 | mister_engage_delay_s | 51 → 42 |
| 06:00 | temp_hysteresis | 2.14 → 1.78 |
| 06:00 | vent_prefer_dp_delta_f | 6 → 5 |
| 06:00 | vent_prefer_temp_delta_f | 7 → 5 |
| 06:00 | vpd_watch_dwell_s | 75 → 60 |
| 09:30 | cold_vent_guard_delta_f | 9 → 8 |
| 09:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 09:30 | fog_escalation_kpa | 0.25 → 0.15 |
| 09:30 | min_fog_off_s | 72 → 60 |
| 09:30 | min_fog_on_s | 59.25 → 63.75 |
| 09:30 | vent_prefer_dp_delta_f | 5 → 3 |
| 09:30 | vent_prefer_temp_delta_f | 5 → 4 |
🌅 Morning Cycle (6:32 AM) — iris-20260901-0630
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20260901-0017
Previous hypothesis: Midnight reset: dry the currently over-wet house before dawn, then precondition ahead of the corrected hot/dry solar ramp. Keep wet assist suppressed while measured VPD is below the band; reopen bounded band-coupled moisture assist as VPD reaches the high edge. Expect zero overnight VPD-low/condensation risk and lower controller-attributable VPD-high exposure during the late-morning ramp, while accepting structural peak-heat limits. Result: Window scorecard: planner score 77.2, temp compliance 71.9%, VPD compliance 73.4%, total stress 2.14h; zero dew-risk reported. Peak temperature prediction was close (89.0F vs actual 88.7F). The 16% RH dry-air premise did not match the 51% indoor RH proxy, and solar was underpredicted (796 vs 1200 W/m2). The predicted high VPD-stress window was overcalled: actual VPD-high exposure was only 0.43h, so band-coupled wet assist largely met its purpose, but corridor compliance remained moderate. Treat the heat residual as partly structural and the forecast-RH mismatch as a reason to confirm live VPD before escalating. Score: 6/10
New finding: On hot-ramp days, early band-coupled wet assist can hold VPD-high exposure near 0.5h even when solar exceeds forecast; keep moisture available near the high edge, but confirm live RH/VPD before maximum escalation. → Added to Lessons Learned
Hypothesis
Testing: Measure whether band-coupled assist at the morning edge plus early peak fog reduces controller-attributable VPD-high misses without evening wet drift. Expected outcome: Keep VPD-low and dew-risk at 0h, mister water within 300 gal, and improve corridor compliance over the 74.4% sunset window despite structural heat limits.
Conditions
89.0°F
16.0%
796.0 W/m²
33.0%
Humid 69F dawn with house VPD 0.58, then clear hot-dry ramp. Last sunset self-score 5 vs anchor 4: safety held, but VPD corridor was weak and 93 guardrail events had 0 dispatches.
Expected stress windows
Band-coupled wet assist, 30% peak duty, fog threshold 0.15, retain wet coverage until measured recovery.
45-60 min thermal lead and 1.5-2F pre-cool; accept physics-limited residual heat.
Parameter rationale
Make wet assist available at the served high edge without wetting the 0.58-kPa dawn house.
Increase safe moisture duty during peak while avoiding sub-30s cycling.
Escalate fog earlier in eligible hot-dry VENTILATE while holding an 8F dew floor.
Setpoints
Tuesday September 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | hyst 0.21750000000000003 | Dawn: dry down the wet 0.58-kPa house before solar ramp; kee |
| 09:00 | hyst 0.20750000000000002 | Morning ramp: exchange cool dry air, then enable edge-trigge |
| 15:00 | hyst 0.21250000000000002 | Peak stress: pre-cool and prioritize band-coupled wet assist |
| 18:00 | hyst 0.21250000000000002 | Decline: retain measured-edge moisture coverage; do not unwi |
| 20:30 | hyst 0.21750000000000003 | Evening: taper only after observed VPD recovery; protect orc |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | s2 1.9025; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.154; all 1.304; pulse 30; gap 60; wt 1.1333333333333333 | Dawn: dry down the wet 0.58-kPa house before solar ramp; kee |
| 09:00 | s2 1.7249999999999999; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.004; all 1.204; pulse 30; gap 52.5; wt 1.4333333333333333 | Morning ramp: exchange cool dry air, then enable edge-trigge |
| 15:00 | s2 1.475; cool_exit 2.05; all_fans 1; dw_stress 1; engage 0.9540000000000001; all 1.154; pulse 41.25; gap 33.75; wt 1.7333333333333334 | Peak stress: pre-cool and prioritize band-coupled wet assist |
| 18:00 | s2 1.7000000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 37.5; gap 37.5; wt 1.6666666666666665 | Decline: retain measured-edge moisture coverage; do not unwi |
| 20:30 | s2 1.7975; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.004; all 1.204; pulse 30; gap 48.75; wt 1.5 | Evening: taper only after observed VPD recovery; protect orc |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:30 | band_track_fraction | initial 0 |
| 06:30 | cold_vent_guard_delta_f | initial 8 |
| 06:30 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:30 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:30 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 06:30 | dwell_gate_ms | initial 300000 |
| 06:30 | enthalpy_close | initial 1 |
| 06:30 | enthalpy_open | initial -2 |
| 06:30 | fog_escalation_kpa | initial 0.4 |
| 06:30 | heat_hysteresis | initial 1 |
| 06:30 | min_fog_off_s | initial 126 |
| 06:30 | min_fog_on_s | initial 39 |
| 06:30 | mist_backoff_s | initial 600 |
| 06:30 | mist_max_closed_vent_s | initial 600 |
| 06:30 | mist_thermal_relief_s | initial 90 |
| 06:30 | mister_all_delay_s | initial 102 |
| 06:30 | mister_engage_delay_s | initial 51 |
| 06:30 | mister_water_budget_gal | initial 300 |
| 06:30 | night_vpd_bias_kpa | initial 0 |
| 06:30 | outdoor_staleness_max_s | initial 600 |
| 06:30 | sw_dwell_gate_enabled | initial 1 |
| 06:30 | sw_fog_closes_vent | initial 1 |
| 06:30 | sw_mister_closes_vent | initial 0 |
| 06:30 | sw_summer_vent_enabled | initial 1 |
| 06:30 | temp_hysteresis | initial 2.14 |
| 06:30 | vent_exchange_fraction | initial 0.3 |
| 06:30 | vent_prefer_dp_delta_f | initial 3 |
| 06:30 | vent_prefer_temp_delta_f | initial 4 |
| 06:30 | vpd_watch_dwell_s | initial 75 |
| 09:00 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.1 |
| 09:00 | dwell_gate_ms | 300000 → 270000 |
| 09:00 | fog_escalation_kpa | 0.4 → 0.25 |
| 09:00 | min_fog_off_s | 126 → 90 |
| 09:00 | min_fog_on_s | 39 → 52.5 |
| 09:00 | mister_all_delay_s | 102 → 93 |
| 09:00 | mister_engage_delay_s | 51 → 46.5 |
| 09:00 | temp_hysteresis | 2.14 → 1.96 |
| 09:00 | vpd_watch_dwell_s | 75 → 67.5 |
| 15:00 | cold_vent_guard_delta_f | 8 → 9 |
| 15:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 15:00 | dwell_gate_ms | 270000 → 285000 |
| 15:00 | fog_escalation_kpa | 0.25 → 0.15 |
| 15:00 | min_fog_off_s | 90 → 60 |
| 15:00 | min_fog_on_s | 52.5 → 63.75 |
| 15:00 | mister_all_delay_s | 93 → 97.5 |
| 15:00 | mister_engage_delay_s | 46.5 → 48.75 |
| 15:00 | temp_hysteresis | 1.96 → 2.05 |
| 15:00 | vent_prefer_dp_delta_f | 3 → 5 |
| 15:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 15:00 | vpd_watch_dwell_s | 67.5 → 71.25 |
| 18:00 | fog_escalation_kpa | 0.15 → 0.2 |
| 18:00 | min_fog_off_s | 60 → 66 |
| 18:00 | min_fog_on_s | 63.75 → 61.5 |
| 18:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 20:30 | cold_vent_guard_delta_f | 9 → 8 |
| 20:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 20:30 | dwell_gate_ms | 285000 → 300000 |
| 20:30 | fog_escalation_kpa | 0.2 → 0.3 |
| 20:30 | min_fog_off_s | 66 → 84 |
| 20:30 | min_fog_on_s | 61.5 → 54.75 |
| 20:30 | mister_all_delay_s | 97.5 → 102 |
| 20:30 | mister_engage_delay_s | 48.75 → 51 |
| 20:30 | temp_hysteresis | 2.05 → 2.14 |
| 20:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 20:30 | vent_prefer_temp_delta_f | 5 → 4 |
| 20:30 | vpd_watch_dwell_s | 71.25 → 75 |
🌆 Evening Cycle (7:35 PM) — iris-20260901-1933
validated
8/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20260901-0630
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:89.0,“outdoor_rh_min_pct”:16.0,“solar_peak_w_m2”:796.0,“cloud_cover_avg_pct”:33.0,“notes”:“Humid 69F dawn with house VPD 0.58, then clear hot-dry ramp. Last sunset self-score 5 vs anchor 4: safety held, but VPD corridor was weak and 93 guardrail events had 0 dispatches.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-09-01T11:00:00-06:00”,“end”:“2026-09-01T20:00:00-06:00”,“severity”:“high”,“mitigation”:“Band-coupled wet assist, 30% peak duty, fog threshold 0.15, retain wet coverage until measured recovery.”},{“kind”:“heat”,“start”:“2026-09-01T12:00:00-06:00”,“end”:“2026-09-01T18:00:00-06:00”,“severity”:“high”,“mitigation”:“45-60 min thermal lead and 1.5-2F pre-cool; accept physics-limited residual heat.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:0.862,“new_value”:0.99,“forecast_anchor”:“Forecast VPD 3.1-3… Result: Window scorecard: planner score 85.8, temp compliance 92.4%, VPD compliance 80.1%, total stress 0.00h (heat 0, cold 0, VPD-high 0, VPD-low 0); dew-risk 0h and minimum dew margin 8.9F. The bounded overnight edge-wetting/taper posture preserved safety and avoided oscillation, with VPD still the weaker axis. Resource cost was unavailable, so efficiency was not gradeable. Score: 8/10
Hypothesis
Conditions
75.0°F
32.0%
0.0 W/m²
45.0%
Cool overnight fall from 78F toward 59-60F; observed house VPD 0.86 and dew margin 8.8F. Main risk is heater/vent oscillation and a brief east-zone dry edge, not condensation.
Expected stress windows
Permit bounded edge wetting only, then taper duty while preserving an 8F dew-margin floor.
Parameter rationale
Avoid VPD-low overshoot and reduce overnight mister cycling while retaining east-zone edge recovery.
Prevent unnecessary fog escalation at the next eligible window unless measured VPD remains above the high edge.
Keep short live-edge recovery available without wetting the in-band house.
Setpoints
Tuesday September 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 19:33 | hyst 0.2175 | evening_settle: taper wetting after the dry edge; stabilize |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 19:33 | s2 1.8625; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.099; all 1.2489999999999999; pulse 30; gap 60; wt 1.28 | evening_settle: taper wetting after the dry edge; stabilize |
Wednesday September 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:30 | hyst 0.22749999999999998 | midnight_posture: humidity should hold; suppress routine wet |
| 05:30 | hyst 0.2175 | pre_dawn: lead cooling ahead of the clear hot ramp; re-open |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:30 | s2 1.98; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.1989999999999998; all 1.299; pulse 30; gap 60; wt 1.1733333333333333 | midnight_posture: humidity should hold; suppress routine wet |
| 05:30 | s2 1.6425; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.149; all 1.2489999999999999; pulse 30; gap 56.25; wt 1.3666666666666667 | pre_dawn: lead cooling ahead of the clear hot ramp; re-open |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 19:33 | band_track_fraction | initial 0 |
| 19:33 | cold_vent_guard_delta_f | initial 11 |
| 19:33 | cool_stage2_exit_hysteresis_f | initial 1 |
| 19:33 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 19:33 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 19:33 | dwell_gate_ms | initial 300000 |
| 19:33 | enthalpy_close | initial 1 |
| 19:33 | enthalpy_open | initial -2 |
| 19:33 | fog_escalation_kpa | initial 0.4 |
| 19:33 | heat_hysteresis | initial 1 |
| 19:33 | min_fog_off_s | initial 114 |
| 19:33 | min_fog_on_s | initial 43.5 |
| 19:33 | mist_backoff_s | initial 600 |
| 19:33 | mist_max_closed_vent_s | initial 600 |
| 19:33 | mist_thermal_relief_s | initial 90 |
| 19:33 | mister_all_delay_s | initial 102 |
| 19:33 | mister_engage_delay_s | initial 51 |
| 19:33 | mister_water_budget_gal | initial 300 |
| 19:33 | night_vpd_bias_kpa | initial 0 |
| 19:33 | outdoor_staleness_max_s | initial 600 |
| 19:33 | sw_dwell_gate_enabled | initial 1 |
| 19:33 | sw_fog_closes_vent | initial 1 |
| 19:33 | sw_mister_closes_vent | initial 0 |
| 19:33 | sw_summer_vent_enabled | initial 1 |
| 19:33 | temp_hysteresis | initial 2.14 |
| 19:33 | vent_exchange_fraction | initial 0.3 |
| 19:33 | vent_prefer_dp_delta_f | initial 5 |
| 19:33 | vent_prefer_temp_delta_f | initial 7 |
| 19:33 | vpd_watch_dwell_s | initial 75 |
| 00:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.25 |
| 00:30 | dwell_gate_ms | 300000 → 330000 |
| 00:30 | fog_escalation_kpa | 0.4 → 0.45 |
| 00:30 | min_fog_off_s | 114 → 126 |
| 00:30 | min_fog_on_s | 43.5 → 39 |
| 00:30 | mister_all_delay_s | 102 → 111 |
| 00:30 | mister_engage_delay_s | 51 → 55.5 |
| 00:30 | temp_hysteresis | 2.14 → 2.3200000000000003 |
| 00:30 | vpd_watch_dwell_s | 75 → 82.5 |
| 05:30 | cold_vent_guard_delta_f | 11 → 9 |
| 05:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.2 |
| 05:30 | dwell_gate_ms | 330000 → 300000 |
| 05:30 | fog_escalation_kpa | 0.45 → 0.4 |
| 05:30 | min_fog_off_s | 126 → 96 |
| 05:30 | min_fog_on_s | 39 → 50.25 |
| 05:30 | mister_all_delay_s | 111 → 102 |
| 05:30 | mister_engage_delay_s | 55.5 → 51 |
| 05:30 | temp_hysteresis | 2.3200000000000003 → 2.14 |
| 05:30 | vent_prefer_temp_delta_f | 7 → 5 |
| 05:30 | vpd_watch_dwell_s | 82.5 → 75 |
End-of-Day Summary
Climate
66.0–87.8°F; avg 75.0°F
0.46–2.09 kPa; avg 0.90 kPa
50.6–79.8%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 5.4h
- VPD stress (>2.0 kPa): 9.5h
- Cold stress (<55°F): 9.3h
Economics
Not available
USD 0.00
USD 1.060
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 325 min | Primary exhaust runtime. |
| Fan 2 | 316 min | Secondary exhaust runtime. |
| Vent | 572 min | Intake vent runtime. |
| Fog | 147 min | Fogger runtime. |
| Heat 1 electric | 110 min | Electric heater runtime. |
| Heat 2 gas | 0 min | Gas heater runtime. |
| Grow lights | 979 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 1.45h | Center mister runtime. |
Water
- Total: 218 gal
- Mister: 50 gal
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 83.2°F | 1.22 kPa | 68.9% |
| 13:00 | 83.6°F | 1.28 kPa | 68.0% |
| 14:00 | 83.8°F | 1.23 kPa | 69.1% |
| 15:00 | 83.9°F | 1.32 kPa | 66.9% |
| 16:00 | 82.9°F | 1.22 kPa | 68.3% |
| 17:00 | 82.0°F | 1.18 kPa | 68.7% |
| 18:00 | 79.8°F | 1.16 kPa | 66.8% |
| 19:00 | 78.3°F | 0.99 kPa | 70.1% |
| 20:00 | 75.9°F | 0.78 kPa | 74.6% |
| 21:00 | 73.0°F | 0.69 kPa | 75.0% |
| 22:00 | 69.3°F | 0.64 kPa | 74.0% |
| 23:00 | 67.7°F | 0.55 kPa | 76.4% |
| 00:00 | 67.2°F | 0.51 kPa | 77.8% |
| 01:00 | 67.2°F | 0.49 kPa | 78.5% |
| 02:00 | 66.8°F | 0.47 kPa | 79.2% |
| 03:00 | 66.3°F | 0.48 kPa | 78.4% |
| 04:00 | 66.4°F | 0.51 kPa | 77.0% |
| 05:00 | 68.3°F | 0.57 kPa | 76.4% |
| 06:00 | 69.3°F | 0.58 kPa | 76.5% |
| 07:00 | 70.4°F | 0.60 kPa | 76.6% |
| 08:00 | 72.7°F | 0.71 kPa | 74.4% |
| 09:00 | 74.2°F | 0.77 kPa | 73.6% |
| 10:00 | 76.4°F | 0.78 kPa | 74.9% |
| 11:00 | 81.3°F | 1.04 kPa | 71.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-08-26 | 6.6h | 8.6h | 8.9h |
| 2026-08-27 | 6.3h | 8.5h | 8.9h |
| 2026-08-28 | 6.1h | 14.8h | 7.6h |
| 2026-08-29 | 7.0h | 30.7h | 5.9h |
| 2026-08-30 | 4.7h | 12.9h | 12.6h |
| 2026-08-31 | 5.1h | 14.2h | 9.2h |
| 2026-09-01 | 5.4h | 9.5h | 9.3h |