September 09, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

6

Plan writes

3

No-change acknowledgements

3

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:17MIDNIGHTplan_writtenWrote public plan iris-20260909-0017. Resolved 00:18 MDT.
Morning planning cycle06:37SUNRISEplan_writtenWrote public plan iris-20260909-0637. Resolved 06:39 MDT.
Solar peak planning checkpoint12:59SOLAR_MAXackedAcknowledged: Solar actual 544 W/m² is below the 14:00 forecast 767 W/m² (and below the bias-corrected ~720); indoor VPD 1.21 kPa is near the active high edge but not climbing rapidly, with 10.5°F dew margin and IDLE action. Existing 14:00 plan waypoint covers the afternoon; no nudge warranted. Resolved 13:00 MDT.
Peak Stress14:59TRANSITIONackedAcknowledged: Peak stress is covered by the active plan: 84.3°F/1.67 kPa with 16.0°F dew margin, vent+both fans+fog and center mist active. VPD-high exposure is 0.68h and heat stress 1.75h today, not clearly beyond plan expectations; no tactical change warranted. Resolved 14:59 MDT.
Decline18:20TRANSITIONackedAcknowledged: Decline conditions are tracking the existing posture: VPD 0.92 kPa is below the 0.99 high edge, temp 80.7F, dew margin 8.9F, and all relays are off in IDLE. No concrete signal warrants a tunable change; live telemetry is more humid than the dry forecast. Resolved 18:21 MDT.
Evening planning cycle19:20SUNSETplan_writtenWrote public plan iris-20260909-1920. Resolved 19:21 MDT.

🌅 Morning Cycle (12:18 AM) — iris-20260909-0017

Status

validated

Outcome score

5/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20260908-0637

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:87.0,“outdoor_rh_min_pct”:17.0,“solar_peak_w_m2”:776.0,“cloud_cover_avg_pct”:27.0,“notes”:“Forecast is near-term hot and dry but historically overstates heat and VPD; live VPD gates intensity, with corrected VPD near 2.23-2.67 kPa at peak.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-09-08T11:00:00-06:00”,“end”:“2026-09-08T18:30:00-06:00”,“severity”:“high”,“mitigation”:“Band-coupled vent-mist assist; moisture excess 0.05, all-zone excess 0.25, fog excess 0.15-0.20.”},{“kind”:“heat”,“start”:“2026-09-08T12:00:00-06:00”,“end”:“2026-09-08T18:30:00-06:00”,“severity”:“high”,“mitigation”:“Morning pre-cool and ventilate; accept structural capacity limits and never trap heat in sealed mist.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.6,“new_value”:1.35,“forecast_anchor”:“Corrected VPD rises to 2.23-2.67 kPa from noon through 18:00… Result: Window 09-09 00:18–06:39: score 78.2; temp compliance 69.6%, VPD compliance 77.2%; stress 1.04h (heat 0, cold 0, VPD-high 0.34h, VPD-low 0); resource terms unavailable. Longer overnight gap/watch dwell limited overshoot but did not eliminate VPD-high exposure; anchor mismatch should be checked against execution fidelity. Score: 5/10

Hypothesis

Testing: Live-gated overnight recovery: taper after observed VPD clears, then test earlier moisture assist at the morning dry ramp. Expected outcome: Keep overnight dew-risk and VPD-low stress at 0h; reduce post-sunrise moisture-gap exposure without pre-wetting the trough, within a 300-gal practical cap.

Setpoints

Wednesday September 09

Primary crop-band changes:

TimeValuesNote
00:17hyst 0.1875Live VPD 1.18 above edge; safe 17.7F dew margin supports a r
03:30hyst 0.1875Cool trough expected; taper only after observed VPD clears a
06:30hyst 0.1875Sunrise ramp begins; live-gate wet assist with south-first p
10:00hyst 0.1875Dry ramp to VPD above 2 kPa; keep vent cooling and moisture

Tactical tunable changes:

TimeValuesNote
00:17s2 1.7725000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.811; all 1.0110000000000001; pulse 33.75; gap 30; wt 1.7000000000000002Live VPD 1.18 above edge; safe 17.7F dew margin supports a r
03:30s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.811; all 1.0110000000000001; pulse 33.75; gap 41.25; wt 1.7Cool trough expected; taper only after observed VPD clears a
06:30s2 1.6125; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.811; all 1.0110000000000001; pulse 33.75; gap 33.75; wt 1.7Sunrise ramp begins; live-gate wet assist with south-first p
10:00s2 1.5100000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.811; all 1.0110000000000001; pulse 41.25; gap 30; wt 1.7666666666666666Dry ramp to VPD above 2 kPa; keep vent cooling and moisture

Changed secondary parameters:

TimeParameterChange
00:17band_track_fractioninitial 0
00:17cold_vent_guard_delta_finitial 8
00:17cool_stage2_exit_hysteresis_finitial 1
00:17direct_wet_stress_min_dew_margin_finitial 8
00:17direct_wet_stress_vpd_margin_kpainitial 0.05
00:17dwell_gate_msinitial 210000
00:17enthalpy_closeinitial 1
00:17enthalpy_openinitial -2
00:17fog_escalation_kpainitial 0.25
00:17heat_hysteresisinitial 1
00:17min_fog_off_sinitial 54
00:17min_fog_on_sinitial 66
00:17mist_backoff_sinitial 600
00:17mist_max_closed_vent_sinitial 600
00:17mist_thermal_relief_sinitial 90
00:17mister_all_delay_sinitial 75
00:17mister_engage_delay_sinitial 37.5
00:17mister_water_budget_galinitial 240
00:17night_vpd_bias_kpainitial 0
00:17outdoor_staleness_max_sinitial 600
00:17sw_dwell_gate_enabledinitial 1
00:17sw_fog_closes_ventinitial 1
00:17sw_mister_closes_ventinitial 0
00:17sw_summer_vent_enabledinitial 1
00:17temp_hysteresisinitial 1.6
00:17vent_exchange_fractioninitial 0.3
00:17vent_prefer_dp_delta_finitial 3
00:17vent_prefer_temp_delta_finitial 4
00:17vpd_watch_dwell_sinitial 52.5
03:30min_fog_off_s54 → 72
03:30min_fog_on_s66 → 59.25
06:30fog_escalation_kpa0.25 → 0.2
06:30min_fog_off_s72 → 60
06:30min_fog_on_s59.25 → 63.75
06:30mister_water_budget_gal240 → 300
10:00fog_escalation_kpa0.2 → 0.15
10:00min_fog_off_s60 → 54
10:00min_fog_on_s63.75 → 66

🌅 Morning Cycle (6:39 AM) — iris-20260909-0637

Status

validated

Outcome score

8/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20260909-0017

Previous hypothesis: Use live VPD and dew margin to bridge the current VPD-high recovery, taper before the cool trough only after observed VPD clears, then enable earlier band-coupled moisture assist for the forecast solar ramp. The prior governing plan scored 6 versus its deterministic anchor 8 because RH was much wetter than forecast; this plan discounts forecast VPD and gates intensity on live telemetry. No DLI or resource-efficiency claim is made while utility terms are unavailable. Result: Window 09-09 06:39–19:21: score 79.9; temp compliance 74.5%, VPD compliance 78.7%; stress 1.86h with 0.61h VPD-high, 0h VPD-low and 0h heat in the scoped window. The forecasted 84F/15% RH dry-heat scenario did not occur: actual peak outdoor temp was 81F and indoor RH proxy was 43%, while solar peaked near 1013 W/m². Band-coupled moisture posture limited VPD-high exposure but did not eliminate it; the forecast anchor materially overpredicted dryness and heat, so the high-intensity ramp hypothesis was only partially tested. Score: 8/10

New finding: When a clear-day forecast materially overpredicts dryness/heat, keep band-coupled moisture assist available but gate escalation on live VPD and temperature; the 2026-09-09 plan contained VPD-high stress to 0.61h in its scoped window but should not pre-stage the most aggressive posture from forecast alone. → Added to Lessons Learned

Hypothesis

Testing: Live-gated band-coupled wet assist: compare dawn telemetry with corrected forecast before tightening pulses; hold recovery until observed VPD clears. Expected outcome: Keep dew-risk and VPD-low stress at 0h; reduce controller-attributable VPD-high below 2.5h versus 2.63h yesterday; preserve 300-gal practical cap; accept weather-limited heat.

Conditions

Outdoor peak

84.0°F

RH minimum

15.0%

Solar peak

785.0 W/m²

Cloud average

3.0%

Clear dry ramp; fresh forecast, live dawn VPD 0.74 kPa; prior RH forecast overstated dryness.

Expected stress windows

vpd_highhigh · 2026-09-09T10:00:00-06:00 to 2026-09-09T19:00:00-06:00

Band-coupled vent-mist assist: engage excess 0.05, all-zone 0.25, fog excess 0.15-0.20.

heatmedium · 2026-09-09T14:00:00-06:00 to 2026-09-09T18:00:00-06:00

Morning pre-cool; keep ventilation dominant and accept capacity-limited heat if outdoor/indoor converge.

Parameter rationale

mister_engage_kpa1.6 → 1.05; VPD rises from 0.74 live at dawn to 2.33-3.34 forecast during 11:00-18:00.

Start bounded assist near the active high-edge margin and reduce controller-attributable VPD-high time.

fog_escalation_kpa0.4 → 0.18; Clear dry ramp with 15-20% RH and 628-785 W/m2 solar at 11:00-18:00.

Offer heavy wet assist earlier during safe daytime gates without sealing against heat.

mister_pulse_gap_s45.0 → 22.0; Live dawn VPD is low; use short gap only after the measured ramp confirms dryness.

Reduce VPD-high moisture gaps while preserving a longer evening taper and 0h dew-risk target.

Setpoints

Wednesday September 09

Primary crop-band changes:

TimeValuesNote
06:30hyst 0.20750000000000002Dawn live VPD 0.74; recover only when observed VPD clears, w
09:00hyst 0.20750000000000002Solar/VPD ramp from 08:00; open band-coupled assist before d
14:00hyst 0.20750000000000002Forecast peak 84F/3.34 kPa; keep vent-mist assist available
18:30hyst 0.20750000000000002VPD remains high after solar decline; taper only after live
21:00hyst 0.20750000000000002Cool clear evening; suppress excess wetting after observed r

Tactical tunable changes:

TimeValuesNote
06:30s2 1.745; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.004; all 1.104; pulse 30; gap 45; wt 1.4666666666666666Dawn live VPD 0.74; recover only when observed VPD clears, w
09:00s2 1.6125; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9540000000000001; all 1.154; pulse 37.5; gap 33.75; wt 1.7000000000000002Solar/VPD ramp from 08:00; open band-coupled assist before d
14:00s2 1.7; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9540000000000001; all 1.154; pulse 41.25; gap 33.75; wt 1.7333333333333334Forecast peak 84F/3.34 kPa; keep vent-mist assist available
18:30s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.004; all 1.104; pulse 33.75; gap 41.25; wt 1.6VPD remains high after solar decline; taper only after live
21:00s2 1.95; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.054; all 1.054; pulse 30; gap 52.5; wt 1.4Cool clear evening; suppress excess wetting after observed r

Changed secondary parameters:

TimeParameterChange
06:30band_track_fractioninitial 0
06:30cold_vent_guard_delta_finitial 8
06:30cool_stage2_exit_hysteresis_finitial 1
06:30direct_wet_stress_min_dew_margin_finitial 8
06:30direct_wet_stress_vpd_margin_kpainitial 0.1
06:30dwell_gate_msinitial 270000
06:30enthalpy_closeinitial 1
06:30enthalpy_openinitial -2
06:30fog_escalation_kpainitial 0.3
06:30heat_hysteresisinitial 1
06:30min_fog_off_sinitial 78
06:30min_fog_on_sinitial 57
06:30mist_backoff_sinitial 600
06:30mist_max_closed_vent_sinitial 600
06:30mist_thermal_relief_sinitial 90
06:30mister_all_delay_sinitial 93
06:30mister_engage_delay_sinitial 46.5
06:30mister_water_budget_galinitial 300
06:30night_vpd_bias_kpainitial 0
06:30outdoor_staleness_max_sinitial 600
06:30sw_dwell_gate_enabledinitial 1
06:30sw_fog_closes_ventinitial 1
06:30sw_mister_closes_ventinitial 0
06:30sw_summer_vent_enabledinitial 1
06:30temp_hysteresisinitial 1.96
06:30vent_exchange_fractioninitial 0.3
06:30vent_prefer_dp_delta_finitial 3
06:30vent_prefer_temp_delta_finitial 4
06:30vpd_watch_dwell_sinitial 67.5
09:00direct_wet_stress_vpd_margin_kpa0.1 → 0.05
09:00fog_escalation_kpa0.3 → 0.2
09:00min_fog_off_s78 → 60
09:00min_fog_on_s57 → 63.75
14:00fog_escalation_kpa0.2 → 0.15
18:30direct_wet_stress_vpd_margin_kpa0.05 → 0.1
18:30fog_escalation_kpa0.15 → 0.2
18:30min_fog_off_s60 → 72
18:30min_fog_on_s63.75 → 59.25
21:00direct_wet_stress_vpd_margin_kpa0.1 → 0.15
21:00fog_escalation_kpa0.2 → 0.3
21:00min_fog_off_s72 → 90
21:00min_fog_on_s59.25 → 52.5

🌆 Evening Cycle (7:21 PM) — iris-20260909-1920

Status

validated

Outcome score

8/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20260909-0637

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:84.0,“outdoor_rh_min_pct”:15.0,“solar_peak_w_m2”:785.0,“cloud_cover_avg_pct”:3.0,“notes”:“Clear dry ramp; fresh forecast, live dawn VPD 0.74 kPa; prior RH forecast overstated dryness.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-09-09T10:00:00-06:00”,“end”:“2026-09-09T19:00:00-06:00”,“severity”:“high”,“mitigation”:“Band-coupled vent-mist assist: engage excess 0.05, all-zone 0.25, fog excess 0.15-0.20.”},{“kind”:“heat”,“start”:“2026-09-09T14:00:00-06:00”,“end”:“2026-09-09T18:00:00-06:00”,“severity”:“medium”,“mitigation”:“Morning pre-cool; keep ventilation dominant and accept capacity-limited heat if outdoor/indoor converge.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.6,“new_value”:1.05,“forecast_anchor”:“VPD rises from 0.74 live at dawn to 2.33-3.34 forecast during 11:00-18:00… Result: Window 09-09 19:21–09-10 00:18: planner score 82.8; temp compliance 84.6%; VPD compliance 81.3%; total stress 0.00h (heat 0, cold 0, VPD-high 0, VPD-low 0); dew risk 0h. Resource terms unavailable, so no cost or water claim. Conservative overnight taper avoided overshoot, but the forecast was not validated against a dry-stress event. Score: 8/10

Hypothesis

Testing: Overnight recovery-gated moisture taper: use live VPD and dew margin to decide whether sparse wet assist persists, then stage the morning ramp. Expected outcome: Keep dew-risk and VPD-low stress at 0h; limit overnight VPD-high exposure to under 1h while reducing relay churn and preparing morning wet assist.

Conditions

Outdoor peak

73.0°F

RH minimum

18.0%

Solar peak

0.0 W/m²

Cloud average

0.0%

Clear cooling night; forecast VPD is likely high-biased. Live VPD is 0.85 kPa with 9F dew margin.

Expected stress windows

vpd_highmedium · 2026-09-09T20:00:00-06:00 to 2026-09-10T03:00:00-06:00

Use live-edge wet assist only above the active high edge; widen overnight gap and keep fog gated.

Parameter rationale

mister_pulse_gap_s45.0 → 60.0; Clear cool night; live VPD 0.85 and dew margin 9F.

Reduce overnight refires and avoid VPD-low overshoot.

vpd_watch_dwell_s60.0 → 90.0; Forecast VPD 1.19-1.35 through 02:00 is likely over-biased.

Suppress short sealed cycles while retaining live-edge recovery.

fog_escalation_kpa0.4 → 0.2; Tomorrow's clear dry ramp follows the overnight plan; fog remains time-gated overnight.

Make morning wet assist available earlier without unnecessary overnight fog.

Setpoints

Wednesday September 09

Primary crop-band changes:

TimeValuesNote
19:20hyst 0.2175evening_settle: sparse recovery-gated wet assist; protect de

Tactical tunable changes:

TimeValuesNote
19:20s2 2.0100000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.05; all 1.25; pulse 30; gap 60; wt 1.32evening_settle: sparse recovery-gated wet assist; protect de

Thursday September 10

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.22749999999999998midnight_posture: widen wetting dwell; taper only after live
05:30hyst 0.20749999999999996pre_dawn: pre-cool and stage band-coupled moisture before th

Tactical tunable changes:

TimeValuesNote
00:00s2 2.025; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.05; all 1.2; pulse 30; gap 60; wt 1.2466666666666666midnight_posture: widen wetting dwell; taper only after live
05:30s2 1.775; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1; all 1.2; pulse 36; gap 52.5; wt 1.52pre_dawn: pre-cool and stage band-coupled moisture before th

Changed secondary parameters:

TimeParameterChange
19:20band_track_fractioninitial 0
19:20cold_vent_guard_delta_finitial 7
19:20cool_stage2_exit_hysteresis_finitial 1
19:20direct_wet_stress_min_dew_margin_finitial 8
19:20direct_wet_stress_vpd_margin_kpainitial 0.1
19:20dwell_gate_msinitial 300000
19:20enthalpy_closeinitial 1
19:20enthalpy_openinitial -2
19:20fog_escalation_kpainitial 0.35
19:20heat_hysteresisinitial 1
19:20min_fog_off_sinitial 114
19:20min_fog_on_sinitial 43.5
19:20mist_backoff_sinitial 600
19:20mist_max_closed_vent_sinitial 600
19:20mist_thermal_relief_sinitial 90
19:20mister_all_delay_sinitial 102
19:20mister_engage_delay_sinitial 51
19:20mister_water_budget_galinitial 220
19:20night_vpd_bias_kpainitial 0
19:20outdoor_staleness_max_sinitial 600
19:20sw_dwell_gate_enabledinitial 1
19:20sw_fog_closes_ventinitial 1
19:20sw_mister_closes_ventinitial 0
19:20sw_summer_vent_enabledinitial 1
19:20temp_hysteresisinitial 2.14
19:20vent_exchange_fractioninitial 0.3
19:20vent_prefer_dp_delta_finitial 3
19:20vent_prefer_temp_delta_finitial 3
19:20vpd_watch_dwell_sinitial 75
00:00cold_vent_guard_delta_f7 → 8
00:00dwell_gate_ms300000 → 330000
00:00min_fog_off_s114 → 120
00:00min_fog_on_s43.5 → 41.25
00:00mister_all_delay_s102 → 111
00:00mister_engage_delay_s51 → 55.5
00:00temp_hysteresis2.14 → 2.3200000000000003
00:00vent_prefer_temp_delta_f3 → 4
00:00vpd_watch_dwell_s75 → 82.5
05:30direct_wet_stress_vpd_margin_kpa0.1 → 0.05
05:30dwell_gate_ms330000 → 270000
05:30fog_escalation_kpa0.35 → 0.2
05:30min_fog_off_s120 → 90
05:30min_fog_on_s41.25 → 52.5
05:30mister_all_delay_s111 → 93
05:30mister_engage_delay_s55.5 → 46.5
05:30mister_water_budget_gal220 → 240
05:30temp_hysteresis2.3200000000000003 → 1.96
05:30vpd_watch_dwell_s82.5 → 67.5

End-of-Day Summary

Climate

Temperature

67.7–86.7°F; avg 75.0°F

VPD

0.60–2.36 kPa; avg 1.00 kPa

Relative humidity

43.4–77.2%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: legacy_invalid_exterior_proxy_plus_fixture_estimate
  • Validity: dli-validity-v1; 2024-01-01T00:00:00+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (>85°F): 3.5h
  • VPD stress (>2.0 kPa): 10.1h
  • Cold stress (<55°F): 11.8h

Economics

Electric

Not available

Gas

USD 0.15

Water

Not available

Total

Not available

Equipment Runtimes

EquipmentRuntimeReading
Fan 1239 minPrimary exhaust runtime.
Fan 2242 minSecondary exhaust runtime.
Vent305 minIntake vent runtime.
Fog132 minFogger runtime.
Heat 1 electric241 minElectric heater runtime.
Heat 2 gas14 minGas heater runtime.
Grow lights1201 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center1.33hCenter mister runtime.

Hourly Pattern

HourTemperatureVPDRH
12:0083.6°F1.31 kPa66.9%
13:0084.3°F1.39 kPa65.6%
14:0086.0°F1.76 kPa59.0%
15:0085.5°F1.74 kPa58.4%
16:0082.8°F1.31 kPa66.1%
17:0081.3°F1.15 kPa68.7%
18:0079.8°F1.07 kPa69.5%
19:0077.6°F0.93 kPa71.5%
20:0075.7°F1.00 kPa67.3%
21:0073.9°F1.20 kPa58.2%
22:0071.9°F1.17 kPa56.6%
23:0070.8°F1.17 kPa54.8%
00:0070.0°F1.16 kPa53.9%
01:0068.4°F0.98 kPa59.0%
02:0068.6°F0.99 kPa59.1%
03:0069.5°F0.86 kPa65.7%
04:0069.1°F0.76 kPa69.3%
05:0068.5°F0.73 kPa69.7%
06:0068.5°F0.73 kPa70.1%
07:0069.8°F0.80 kPa68.4%
08:0071.8°F0.90 kPa66.7%
09:0072.6°F1.03 kPa62.5%
10:0076.2°F1.17 kPa62.2%
11:0080.1°F1.17 kPa66.6%

7-Day Stress Context

DateHeatVPD highCold
2026-09-035.7h15.2h8.9h
2026-09-046.9h15.8h8.1h
2026-09-055.1h16.0h9.5h
2026-09-064.4h15.3h9.2h
2026-09-074.3h12.1h8.5h
2026-09-084.0h14.2h10.0h
2026-09-093.5h10.1h11.8h