October 02, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
3
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261002-0016. Resolved 00:17 MDT. |
| Morning planning cycle | 06:59 | SUNRISE | plan_written | Wrote public plan iris-20261002-0659. Resolved 07:01 MDT. |
| Solar peak planning checkpoint | 12:52 | SOLAR_MAX | acked | Acknowledged: Solar is 779 W/m² versus 678 forecast (+47 W/m² calibration-adjusted overshoot), but fresh house VPD is 1.06 kPa, below the dispatcher high edge (~1.22), temp 81.1°F, dew margin 9.7°F, and crop-zone VPD is west 0.96/east 0.80. The existing 14:30 hot-dry posture covers the afternoon; north is a non-crop outlier. No tactical write. Resolved 12:52 MDT. |
| Peak Stress | 14:51 | TRANSITION | acked | Acknowledged: Fresh crop-zone conditions are tracking the active plan: house 84.4F/1.11 kPa VPD with 9.5F dew margin, all equipment off, and no controller-attributable edge requiring a tactical change. North is a dry equipment-zone outlier; do not tune the crop posture to it. Resolved 14:52 MDT. |
| Decline | 17:41 | TRANSITION | acked | Acknowledged: Decline is tracking the active taper plan: house is IDLE at 82.5F/1.09 kPa VPD with 10.2F dew margin, all wet/cooling equipment off, and future waypoints already widen mist gap to 38s then 60s while raising fog threshold. No additional tunable change is warranted. Resolved 17:42 MDT. |
| Evening planning cycle | 18:42 | SUNSET | plan_written | Wrote public plan iris-20261002-1842. Resolved 18:43 MDT. |
| Forecast deviation | 18:52 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261002-1855. Resolved 18:55 MDT. |
🌅 Morning Cycle (12:17 AM) — iris-20261002-0016
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261001-0659
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:73.0,“outdoor_rh_min_pct”:31.0,“solar_peak_w_m2”:670.0,“cloud_cover_avg_pct”:15.0,“notes”:“Cool dawn then clear dry ramp. Prior plan self-score 5 versus deterministic anchor 1: dew safety and scoped VPD protection were real, but 72/81 moisture guardrail holds, cold exposure, and missing physical/cost/DLI evidence limit causal credit. Forecast RH/VPD has material 06-24h bias; live telemetry is fresh.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-01T06:59:00-06:00”,“end”:“2026-10-01T10:00:00-06:00”,“severity”:“medium”,“mitigation”:“low-wet dawn bridge, stable heat lead, and high churn penalty”},{“kind”:“vpd_high”,“start”:“2026-10-01T12:00:00-06:00”,“end”:“2026-10-01T18:30:00-06:00”,“severity”:“high”,“mitigation”:“band-coupled mist assist, fog excess 0.20, and 8F dew floor”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:0… Result: Scoped window 2026-10-02 00:17-07:01: plan preserved safe overnight posture with 0h VPD-low and 0h dew-risk, but nominal cold stress was about 2.04h and VPD-high about 3.13h; window planner score was 72.4 with temp compliance 24.4% and VPD compliance 59.6%. Evidence was controller-credit only: resource terms, physical crop-band, fixed-panel, and DLI endpoints unavailable. Outcome is only partially successful because the low-wet posture did not demonstrate strong temperature compliance and the short window limits causal attribution. Score: 3/10
Hypothesis
Testing: Test low-wet dawn stability followed by live-VPD-gated moisture assist before the Friday dry peak; separate guardrail execution from forecast skill.
Setpoints
Friday October 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.22250000000000003 | Fresh VPD 0.59 and open too-wet alert: no overnight wet assi |
| 04:30 | hyst 0.22250000000000003 | Forecast 46F/0.12 kPa pre-dawn: stable heat lead, no wet cyc |
| 08:00 | hyst 0.21750000000000003 | Cold humid sunrise ramp: keep wet duty near zero while allow |
| 12:00 | hyst 0.2025 | Forecast reaches 71F/1.59 kPa at noon: stage assist before t |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.9525000000000001; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.958; all 1.108; pulse 30; gap 60; wt 1.1333333333333333 | Fresh VPD 0.59 and open too-wet alert: no overnight wet assi |
| 04:30 | s2 1.9525000000000001; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.958; all 1.108; pulse 30; gap 60; wt 1.1333333333333333 | Forecast 46F/0.12 kPa pre-dawn: stable heat lead, no wet cyc |
| 08:00 | s2 1.7475; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.908; all 1.058; pulse 30; gap 60; wt 1.2333333333333334 | Cold humid sunrise ramp: keep wet duty near zero while allow |
| 12:00 | s2 1.5250000000000001; cool_exit 1.87; all_fans 1; dw_stress 1; engage 0.808; all 1.008; pulse 37.5; gap 33.75; wt 1.7000000000000002 | Forecast reaches 71F/1.59 kPa at noon: stage assist before t |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 9 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 00:15 | dwell_gate_ms | initial 315000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.45 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 126 |
| 00:15 | min_fog_on_s | initial 39 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 106.5 |
| 00:15 | mister_engage_delay_s | initial 53.25 |
| 00:15 | mister_water_budget_gal | initial 150 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.23 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 4 |
| 00:15 | vent_prefer_temp_delta_f | initial 5 |
| 00:15 | vpd_watch_dwell_s | initial 78.75 |
| 04:30 | fog_escalation_kpa | 0.45 → 0.5 |
| 08:00 | cold_vent_guard_delta_f | 9 → 8 |
| 08:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.15 |
| 08:00 | dwell_gate_ms | 315000 → 300000 |
| 08:00 | fog_escalation_kpa | 0.5 → 0.35 |
| 08:00 | min_fog_off_s | 126 → 114 |
| 08:00 | min_fog_on_s | 39 → 43.5 |
| 08:00 | mister_all_delay_s | 106.5 → 102 |
| 08:00 | mister_engage_delay_s | 53.25 → 51 |
| 08:00 | temp_hysteresis | 2.23 → 2.14 |
| 08:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 08:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 08:00 | vpd_watch_dwell_s | 78.75 → 75 |
| 12:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.05 |
| 12:00 | dwell_gate_ms | 300000 → 255000 |
| 12:00 | fog_escalation_kpa | 0.35 → 0.18 |
| 12:00 | min_fog_off_s | 114 → 60 |
| 12:00 | min_fog_on_s | 43.5 → 63.75 |
| 12:00 | mister_all_delay_s | 102 → 88.5 |
| 12:00 | mister_engage_delay_s | 51 → 44.25 |
| 12:00 | mister_water_budget_gal | 150 → 180 |
| 12:00 | temp_hysteresis | 2.14 → 1.87 |
| 12:00 | vpd_watch_dwell_s | 75 → 63.75 |
🌅 Morning Cycle (7:01 AM) — iris-20261002-0659
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261002-0016
Previous hypothesis: Completed-window review: iris-20261001-0659 scored 4/10 versus deterministic anchor 1; 159 of 173 VPD guardrail events held requested changes, so its under-2h VPD-high goal and cold-risk control were not demonstrated despite 0h dew risk. iris-20261001-1844 scored 1/10 because its 7-minute window was not testable. The 2026-10-01 scorecard was 73.6 with resource terms unavailable, 13.25h nominal cold stress, 8.43h nominal VPD-high stress, and 9.1F minimum dew margin. Current telemetry is fresh and IDLE at 65F/0.59 kPa with all equipment off, but an open too-wet alert requires no overnight wetting. Forecast shows 46F/0.12 kPa pre-dawn, then 83F/3.27 kPa Friday afternoon and 88F/3.96 kPa Saturday; use a low-wet pre-dawn bridge and live-VPD-gated band-coupled assist at the noon ramp… Result: Scoped window scorecard: planner_score 67.9 with resource weight 0; nominal cold stress 5.10h and VPD-high stress 3.33h, so the predicted under-2h VPD-high and cold-risk reduction were not demonstrated. Dew-risk and VPD-low remained 0h; physical crop-band, fixed-panel, resource-cost, DLI, and experiment-endpoint evidence were unavailable. Guardrail audit also showed many requested rows missed/held, limiting causal credit. Score: 3/10
New finding: When a forecast-supported live-edge plan has substantial guardrail misses and physical/resource evidence is unavailable, score safety and execution separately; do not claim moisture or forecast-calibration benefit without a controller-attributable improvement. → Added to Lessons Learned
Hypothesis
Testing: Test guarded dawn to live-confirmed band-coupled dry-ramp assist, holding an evening recovery shoulder until VPD clears the high edge; compare requested versus guardrailed execution. Expected outcome: Keep dew-risk and VPD-low stress at 0h; reduce controller-attributable VPD-high below yesterday’s 8.43h when wet assist is served, while treating residual heat as potentially physics-limited.
Conditions
83.0°F
13.0%
678.0 W/m²
1.0%
Cool dawn then clear dry ramp. Prior self-score 5 versus deterministic anchor 1: safety credit was real, but 98/112 guardrail holds and unavailable physical, resource, fixed-panel, and DLI evidence limit causal credit; this plan separates live-edge response from forecast skill.
Expected stress windows
heat lead and high churn penalty; no wetting while dawn VPD is near the low edge
band-coupled mist/fog assist in VENTILATE; hold recovery shoulder until live VPD clears high edge
Parameter rationale
start assist before the dry peak without pre-wetting the cool dawn
increase evaporation during confirmed dry stress without lengthening pulse-on time
allow earlier vent-fog assist while preserving the 8F dew floor
Setpoints
Friday October 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:55 | hyst 0.21750000000000003 | Guarded dawn: 45-54F outdoor, VPD near low edge; prioritize |
| 09:30 | hyst 0.20750000000000002 | Solar ramp: move to band-coupled wet assist only as live VPD |
| 14:30 | hyst 0.1975 | Peak dry stress: 13-20% RH, 582-678 W/m2; vent-mist/fog assi |
| 18:30 | hyst 0.20750000000000002 | Decline: keep wet assist through recovery; do not unwind on |
| 21:30 | hyst 0.21750000000000003 | Evening shoulder: taper only after live VPD clears high edge |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:55 | s2 1.785; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.154; all 1.254; pulse 30; gap 60; wt 1.3333333333333333 | Guarded dawn: 45-54F outdoor, VPD near low edge; prioritize |
| 09:30 | s2 1.6375000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.004; all 1.154; pulse 30; gap 45; wt 1.5333333333333332 | Solar ramp: move to band-coupled wet assist only as live VPD |
| 14:30 | s2 1.4900000000000002; cool_exit 1.78; all_fans 1; dw_stress 1; engage 0.9540000000000001; all 1.154; pulse 41.25; gap 30; wt 1.7666666666666666 | Peak dry stress: 13-20% RH, 582-678 W/m2; vent-mist/fog assi |
| 18:30 | s2 1.695; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 37.5; gap 37.5; wt 1.6666666666666665 | Decline: keep wet assist through recovery; do not unwind on |
| 21:30 | s2 1.96; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.004; all 1.204; pulse 30; gap 60; wt 1.3333333333333333 | Evening shoulder: taper only after live VPD clears high edge |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:55 | band_track_fraction | initial 0 |
| 06:55 | cold_vent_guard_delta_f | initial 8 |
| 06:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:55 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:55 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 06:55 | dwell_gate_ms | initial 300000 |
| 06:55 | enthalpy_close | initial 1 |
| 06:55 | enthalpy_open | initial -2 |
| 06:55 | fog_escalation_kpa | initial 0.35 |
| 06:55 | heat_hysteresis | initial 1 |
| 06:55 | min_fog_off_s | initial 102 |
| 06:55 | min_fog_on_s | initial 48 |
| 06:55 | mist_backoff_s | initial 600 |
| 06:55 | mist_max_closed_vent_s | initial 600 |
| 06:55 | mist_thermal_relief_s | initial 90 |
| 06:55 | mister_all_delay_s | initial 102 |
| 06:55 | mister_engage_delay_s | initial 51 |
| 06:55 | mister_water_budget_gal | initial 150 |
| 06:55 | night_vpd_bias_kpa | initial 0 |
| 06:55 | outdoor_staleness_max_s | initial 600 |
| 06:55 | sw_dwell_gate_enabled | initial 1 |
| 06:55 | sw_fog_closes_vent | initial 1 |
| 06:55 | sw_mister_closes_vent | initial 0 |
| 06:55 | sw_summer_vent_enabled | initial 1 |
| 06:55 | temp_hysteresis | initial 2.14 |
| 06:55 | vent_exchange_fraction | initial 0.3 |
| 06:55 | vent_prefer_dp_delta_f | initial 3 |
| 06:55 | vent_prefer_temp_delta_f | initial 4 |
| 06:55 | vpd_watch_dwell_s | initial 75 |
| 09:30 | cold_vent_guard_delta_f | 8 → 9 |
| 09:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.1 |
| 09:30 | dwell_gate_ms | 300000 → 270000 |
| 09:30 | fog_escalation_kpa | 0.35 → 0.25 |
| 09:30 | min_fog_off_s | 102 → 78 |
| 09:30 | min_fog_on_s | 48 → 57 |
| 09:30 | mister_all_delay_s | 102 → 93 |
| 09:30 | mister_engage_delay_s | 51 → 46.5 |
| 09:30 | temp_hysteresis | 2.14 → 1.96 |
| 09:30 | vent_prefer_temp_delta_f | 4 → 5 |
| 09:30 | vpd_watch_dwell_s | 75 → 67.5 |
| 14:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 14:30 | dwell_gate_ms | 270000 → 240000 |
| 14:30 | fog_escalation_kpa | 0.25 → 0.15 |
| 14:30 | min_fog_off_s | 78 → 54 |
| 14:30 | min_fog_on_s | 57 → 66 |
| 14:30 | mister_all_delay_s | 93 → 84 |
| 14:30 | mister_engage_delay_s | 46.5 → 42 |
| 14:30 | temp_hysteresis | 1.96 → 1.78 |
| 14:30 | vpd_watch_dwell_s | 67.5 → 60 |
| 18:30 | cold_vent_guard_delta_f | 9 → 8 |
| 18:30 | dwell_gate_ms | 240000 → 270000 |
| 18:30 | min_fog_off_s | 54 → 66 |
| 18:30 | min_fog_on_s | 66 → 61.5 |
| 18:30 | mister_all_delay_s | 84 → 93 |
| 18:30 | mister_engage_delay_s | 42 → 46.5 |
| 18:30 | temp_hysteresis | 1.78 → 1.96 |
| 18:30 | vent_prefer_temp_delta_f | 5 → 4 |
| 18:30 | vpd_watch_dwell_s | 60 → 67.5 |
| 21:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 21:30 | dwell_gate_ms | 270000 → 300000 |
| 21:30 | fog_escalation_kpa | 0.15 → 0.35 |
| 21:30 | min_fog_off_s | 66 → 102 |
| 21:30 | min_fog_on_s | 61.5 → 48 |
| 21:30 | mister_all_delay_s | 93 → 102 |
| 21:30 | mister_engage_delay_s | 46.5 → 51 |
| 21:30 | temp_hysteresis | 1.96 → 2.14 |
| 21:30 | vpd_watch_dwell_s | 67.5 → 75 |
🌆 Evening Cycle (6:43 PM) — iris-20261002-1842
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261002-0659
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:83.0,“outdoor_rh_min_pct”:13.0,“solar_peak_w_m2”:678.0,“cloud_cover_avg_pct”:1.0,“notes”:“Cool dawn then clear dry ramp. Prior self-score 5 versus deterministic anchor 1: safety credit was real, but 98/112 guardrail holds and unavailable physical, resource, fixed-panel, and DLI evidence limit causal credit; this plan separates live-edge response from forecast skill.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-02T06:55:00-06:00”,“end”:“2026-10-02T09:00:00-06:00”,“severity”:“medium”,“mitigation”:“heat lead and high churn penalty; no wetting while dawn VPD is near the low edge”},{“kind”:“vpd_high”,“start”:“2026-10-02T11:30:00-06:00”,“end”:“2026-10-02T19:30:00-06:00”,“severity”:“high”,“mitigation”:“band-coupled mist/fog assist in VENTILATE; hold recovery shoulder until live VPD clears high edge”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old… Result: Scoped 2026-10-02 evening handoff window was only 0.008h: planner_score 84.4, binary temp compliance 0.0%, VPD compliance 100.0%, nominal stress 0.00h, dew-risk 0.00h. Safe IDLE telemetry and healthy dew margin matched the low-wet recovery intent, but the window was too short to test the forecast-dry-ramp hypothesis or establish actuator benefit; resource, physical crop-band, fixed-panel, and DLI evidence were unavailable. Audit context shows the subsequent 1855 plan had 23 already-at-value and 16 missed rows, so execution causality is limited. Score: 5/10
New finding: For a sub-1-minute or otherwise very short handoff window, credit safety and persistence separately but do not claim forecast or actuator efficacy; require a longer scoped window for causal grading. → Added to Lessons Learned
Hypothesis
Testing: Test a short live-VPD recovery shoulder followed by low-wet cold-night stabilization; compare stress and guardrail execution. Expected outcome: Keep overnight dew-risk and VPD-low at 0h, reduce added cold/VPD-high exposure versus the prior 00:17-07:01 window, and enter Saturday’s dry ramp with stable low-churn posture.
Conditions
84.0°F
11.0%
653.0 W/m²
2.0%
Evaluated prior completed plan scored 3 versus deterministic anchor 1: dew safety was preserved, but cold/VPD-high exposure persisted and causal evidence was limited. Current live state is IDLE at 80.4F/1.00 kPa with 9.8F dew margin; near-term forecast falls to 51F/0.65 kPa by dawn, then turns hot and very dry Saturday. Resource, fixed-panel crop-band, and DLI evidence remain unavailable.
Expected stress windows
Keep a bounded live-VPD recovery shoulder while dew margin stays above 8F; taper only after measured recovery.
Use long thermal lead, conservative outdoor exchange, low wet duty, and high churn penalty.
Parameter rationale
Preserve the recovery shoulder without carrying frequent wet pulses into the cold, low-VPD night.
Keep limited wet assist available at the live edge, then let the overnight intent taper it after recovery.
Dampen marginal heat/vent transitions and protect overnight stability without changing crop bands.
Setpoints
Friday October 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:40 | hyst 0.1875 | Live VPD is at the high edge; retain bounded recovery wet as |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:40 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7666666666666666 | Live VPD is at the high edge; retain bounded recovery wet as |
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.1875 | Forecast VPD is below the high edge; taper wet duty and prio |
| 05:45 | hyst 0.1875 | Pre-dawn low is 51F/0.65 kPa; hold heat lead and avoid wetti |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | Forecast VPD is below the high edge; taper wet duty and prio |
| 05:45 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | Pre-dawn low is 51F/0.65 kPa; hold heat lead and avoid wetti |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:40 | band_track_fraction | initial 0 |
| 18:40 | cold_vent_guard_delta_f | initial 10 |
| 18:40 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:40 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:40 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:40 | dwell_gate_ms | initial 210000 |
| 18:40 | enthalpy_close | initial 1 |
| 18:40 | enthalpy_open | initial -2 |
| 18:40 | fog_escalation_kpa | initial 0.25 |
| 18:40 | heat_hysteresis | initial 1 |
| 18:40 | min_fog_off_s | initial 72 |
| 18:40 | min_fog_on_s | initial 59.25 |
| 18:40 | mist_backoff_s | initial 600 |
| 18:40 | mist_max_closed_vent_s | initial 600 |
| 18:40 | mist_thermal_relief_s | initial 90 |
| 18:40 | mister_all_delay_s | initial 75 |
| 18:40 | mister_engage_delay_s | initial 37.5 |
| 18:40 | mister_water_budget_gal | initial 150 |
| 18:40 | night_vpd_bias_kpa | initial 0 |
| 18:40 | outdoor_staleness_max_s | initial 600 |
| 18:40 | sw_dwell_gate_enabled | initial 1 |
| 18:40 | sw_fog_closes_vent | initial 1 |
| 18:40 | sw_mister_closes_vent | initial 0 |
| 18:40 | sw_summer_vent_enabled | initial 1 |
| 18:40 | temp_hysteresis | initial 1.6 |
| 18:40 | vent_exchange_fraction | initial 0.3 |
| 18:40 | vent_prefer_dp_delta_f | initial 4 |
| 18:40 | vent_prefer_temp_delta_f | initial 6 |
| 18:40 | vpd_watch_dwell_s | initial 52.5 |
| 00:15 | cold_vent_guard_delta_f | 10 → 12 |
| 00:15 | mister_water_budget_gal | 150 → 120 |
| 00:15 | vent_prefer_dp_delta_f | 4 → 5 |
| 00:15 | vent_prefer_temp_delta_f | 6 → 8 |
| 05:45 | cold_vent_guard_delta_f | 12 → 13 |
| 05:45 | vent_prefer_dp_delta_f | 5 → 6 |
| 05:45 | vent_prefer_temp_delta_f | 8 → 9 |
🌆 Evening Cycle (6:55 PM) — iris-20261002-1855
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261002-0659
Result: Scoped 0.224h window was safe but too short to test the dry-ramp hypothesis: planner score 71.6, binary temp compliance 0.0%, VPD compliance 100.0%, 0.00h nominal stress, 0.00h dew-risk, minimum dew margin 8.1F. Resource/cost, physical crop-band, fixed-panel, DLI, and experiment-endpoint evidence were unavailable; no causal actuator benefit demonstrated. Score: 5/10
Hypothesis
Testing: Test cloud-miss replacement: low-wet cold bridge plus band-coupled dry-ramp assist, measuring stress and guardrail execution. Expected outcome: Keep VPD-low and dew-risk at 0h; reduce controller-attributable VPD-high/cold exposure versus the prior window while tracking capacity-limited heat.
Setpoints
Friday October 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:50 | hyst 0.1875 | Cloud miss; fresh IDLE is safe, but VPD is just over the hig |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:50 | s2 1.865; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 33.75; gap 33.75; wt 1.7 | Cloud miss; fresh IDLE is safe, but VPD is just over the hig |
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 05:30 | hyst 0.1875 | Cold, low-VPD dawn: heat lead and low wet duty prevent oscil |
| 09:30 | hyst 0.1875 | Start assist before the clear dry ramp; retain dew and churn |
| 13:00 | hyst 0.1875 | Forecast peak is hot/dry; prioritize safe band-coupled vent- |
| 19:00 | hyst 0.1875 | Keep recovery shoulder until live VPD clears; do not unwind |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 05:30 | s2 1.895; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 33.75; gap 41.25; wt 1.7 | Cold, low-VPD dawn: heat lead and low wet duty prevent oscil |
| 09:30 | s2 1.7337500000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 37.5; gap 33.75; wt 1.7000000000000002 | Start assist before the clear dry ramp; retain dew and churn |
| 13:00 | s2 1.5725; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 52.5; gap 26.25; wt 1.9 | Forecast peak is hot/dry; prioritize safe band-coupled vent- |
| 19:00 | s2 1.895; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 33.75; gap 41.25; wt 1.7 | Keep recovery shoulder until live VPD clears; do not unwind |
Sunday October 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.1875 | Cool dawn reset: minimize wetting and relay churn before Sun |
| 12:30 | hyst 0.1875 | Sunday dry peak: maintain earlier moisture availability with |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.895; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 33.75; gap 41.25; wt 1.7 | Cool dawn reset: minimize wetting and relay churn before Sun |
| 12:30 | s2 1.5725; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 48.75; gap 26.25; wt 1.8666666666666667 | Sunday dry peak: maintain earlier moisture availability with |
Monday October 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:30 | hyst 0.1825 | Extreme Monday heat is capacity-limited; pre-cool and preser |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:30 | s2 1.5050000000000001; cool_exit 1.51; all_fans 0; dw_stress 1; engage 0.988; all 1.188; pulse 60; gap 22.5; wt 2 | Extreme Monday heat is capacity-limited; pre-cool and preser |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:50 | band_track_fraction | initial 0 |
| 18:50 | cold_vent_guard_delta_f | initial 9 |
| 18:50 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:50 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:50 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:50 | dwell_gate_ms | initial 210000 |
| 18:50 | enthalpy_close | initial 1 |
| 18:50 | enthalpy_open | initial -2 |
| 18:50 | fog_escalation_kpa | initial 0.25 |
| 18:50 | heat_hysteresis | initial 1 |
| 18:50 | min_fog_off_s | initial 60 |
| 18:50 | min_fog_on_s | initial 63.75 |
| 18:50 | mist_backoff_s | initial 600 |
| 18:50 | mist_max_closed_vent_s | initial 600 |
| 18:50 | mist_thermal_relief_s | initial 90 |
| 18:50 | mister_all_delay_s | initial 75 |
| 18:50 | mister_engage_delay_s | initial 37.5 |
| 18:50 | mister_water_budget_gal | initial 150 |
| 18:50 | night_vpd_bias_kpa | initial 0 |
| 18:50 | outdoor_staleness_max_s | initial 600 |
| 18:50 | sw_dwell_gate_enabled | initial 1 |
| 18:50 | sw_fog_closes_vent | initial 1 |
| 18:50 | sw_mister_closes_vent | initial 0 |
| 18:50 | sw_summer_vent_enabled | initial 1 |
| 18:50 | temp_hysteresis | initial 1.6 |
| 18:50 | vent_exchange_fraction | initial 0.3 |
| 18:50 | vent_prefer_dp_delta_f | initial 3 |
| 18:50 | vent_prefer_temp_delta_f | initial 5 |
| 18:50 | vpd_watch_dwell_s | initial 52.5 |
| 05:30 | cold_vent_guard_delta_f | 9 → 10 |
| 05:30 | min_fog_off_s | 60 → 72 |
| 05:30 | min_fog_on_s | 63.75 → 59.25 |
| 05:30 | mister_water_budget_gal | 150 → 120 |
| 05:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 05:30 | vent_prefer_temp_delta_f | 5 → 6 |
| 09:30 | cold_vent_guard_delta_f | 10 → 8 |
| 09:30 | fog_escalation_kpa | 0.25 → 0.2 |
| 09:30 | min_fog_off_s | 72 → 60 |
| 09:30 | min_fog_on_s | 59.25 → 63.75 |
| 09:30 | mister_water_budget_gal | 120 → 220 |
| 09:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 09:30 | vent_prefer_temp_delta_f | 6 → 4 |
| 13:00 | fog_escalation_kpa | 0.2 → 0.15 |
| 13:00 | min_fog_off_s | 60 → 48 |
| 13:00 | min_fog_on_s | 63.75 → 68.25 |
| 13:00 | mister_water_budget_gal | 220 → 280 |
| 19:00 | cold_vent_guard_delta_f | 8 → 9 |
| 19:00 | fog_escalation_kpa | 0.15 → 0.25 |
| 19:00 | min_fog_off_s | 48 → 72 |
| 19:00 | min_fog_on_s | 68.25 → 59.25 |
| 19:00 | mister_water_budget_gal | 280 → 180 |
| 19:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 08:00 | cold_vent_guard_delta_f | 9 → 10 |
| 08:00 | mister_water_budget_gal | 180 → 120 |
| 08:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 08:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 12:30 | cold_vent_guard_delta_f | 10 → 8 |
| 12:30 | fog_escalation_kpa | 0.25 → 0.15 |
| 12:30 | min_fog_off_s | 72 → 48 |
| 12:30 | min_fog_on_s | 59.25 → 68.25 |
| 12:30 | mister_water_budget_gal | 120 → 260 |
| 12:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 12:30 | vent_prefer_temp_delta_f | 6 → 4 |
| 12:30 | dwell_gate_ms | 210000 → 195000 |
| 12:30 | min_fog_off_s | 48 → 42 |
| 12:30 | min_fog_on_s | 68.25 → 70.5 |
| 12:30 | mister_all_delay_s | 75 → 70.5 |
| 12:30 | mister_engage_delay_s | 37.5 → 35.25 |
| 12:30 | mister_water_budget_gal | 260 → 300 |
| 12:30 | temp_hysteresis | 1.6 → 1.51 |
| 12:30 | vpd_watch_dwell_s | 52.5 → 48.75 |
End-of-Day Summary
Climate
61.8–85.8°F; avg 72.1°F
0.51–1.89 kPa; avg 0.87 kPa
55.4–75.3%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 2.5h
- VPD stress (>2.0 kPa): 7.8h
- Cold stress (<55°F): 13.7h
Economics
Not available
USD 0.37
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 37 min | Primary exhaust runtime. |
| Fan 2 | 35 min | Secondary exhaust runtime. |
| Vent | 72 min | Intake vent runtime. |
| Fog | 72 min | Fogger runtime. |
| Heat 1 electric | 575 min | Electric heater runtime. |
| Heat 2 gas | 36 min | Gas heater runtime. |
| Grow lights | 832 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.26h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 74% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 80% | 7 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 80% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Lime tree appears healthy with adequate soil moisture. || Lime tree on the floor looks generally healthy, though lighting is low. || Plants on the left shelving unit seem stable, but detailed assessment is difficult due to lighting. || The lime tree in the west zone looks generally healthy with green foliage. || Tree appears healthy with green leaves. || Tree looks generally healthy, but some lower leaves show slight yellowing. || Tree looks generally healthy, though lighting is low in this area. || Vegetative growth looks normal, no obvious signs of stress.
Hanging orchids appear healthy, though lighting is poor for detailed inspection. || Hanging orchids appear robust with healthy root systems. || Hanging orchids, including one with purple blooms, look very healthy with extensive root systems. || Hanging plants appear healthy with no obvious signs of stress in the IR view. || Orchid is in full bloom and appears very healthy. || Orchids appear healthy, but hard to see detail from this distance. || Orchids hanging in the center appear healthy, though some lower leaves might be slightly yellowing. Hard to tell definitively from this distance.
Seedlings appear healthy and are establishing well in the hydroponic system. || Seedlings appear healthy in the hydroponic system. || Seedlings appear healthy under grow lights. || Seedlings in hydroponic system appear healthy.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 79.4°F | 1.21 kPa | 65.4% |
| 13:00 | 83.1°F | 1.27 kPa | 68.6% |
| 14:00 | 83.8°F | 1.34 kPa | 67.7% |
| 15:00 | 83.9°F | 1.26 kPa | 69.1% |
| 16:00 | 83.9°F | 1.15 kPa | 70.9% |
| 17:00 | 81.2°F | 1.20 kPa | 67.0% |
| 18:00 | 78.1°F | 1.07 kPa | 67.6% |
| 19:00 | 75.2°F | 0.95 kPa | 68.4% |
| 20:00 | 72.8°F | 0.85 kPa | 69.6% |
| 21:00 | 70.8°F | 0.78 kPa | 70.3% |
| 22:00 | 68.1°F | 0.68 kPa | 71.0% |
| 23:00 | 66.3°F | 0.63 kPa | 71.6% |
| 00:00 | 64.7°F | 0.59 kPa | 72.0% |
| 01:00 | 63.6°F | 0.57 kPa | 71.6% |
| 02:00 | 62.8°F | 0.58 kPa | 70.6% |
| 03:00 | 62.6°F | 0.57 kPa | 70.8% |
| 04:00 | 62.4°F | 0.58 kPa | 70.2% |
| 05:00 | 62.2°F | 0.54 kPa | 71.6% |
| 06:00 | 63.0°F | 0.57 kPa | 71.3% |
| 07:00 | 66.2°F | 0.77 kPa | 65.4% |
| 08:00 | 67.3°F | 0.82 kPa | 64.2% |
| 09:00 | 68.5°F | 0.85 kPa | 64.7% |
| 10:00 | 71.3°F | 0.98 kPa | 62.8% |
| 11:00 | 73.4°F | 1.08 kPa | 61.9% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-09-26 | 2.4h | 7.0h | 13.0h |
| 2026-09-27 | 2.6h | 9.3h | 13.5h |
| 2026-09-28 | 0.0h | 9.7h | 12.7h |
| 2026-09-29 | 1.9h | 7.8h | 13.2h |
| 2026-09-30 | 0.0h | 9.4h | 14.1h |
| 2026-10-01 | 2.7h | 8.4h | 13.4h |
| 2026-10-02 | 2.5h | 7.8h | 13.7h |