October 03, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261003-0017. Resolved 00:17 MDT. |
| Morning planning cycle | 07:00 | SUNRISE | plan_written | Wrote public plan iris-20261003-0700. Resolved 07:02 MDT. |
| Solar peak planning checkpoint | 12:51 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 12:52 MDT. |
| Peak Stress | 14:51 | TRANSITION | acked | Acknowledged: Peak stress is tracking the active posture: fresh 84.5F/1.43 kPa VPD with healthy 12.5F dew margin, fog active, and no relay churn. Existing plan already stages the 17:00 moisture taper; no additional write is justified. Resolved 14:51 MDT. |
| Decline | 17:40 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 17:41 MDT. |
| Forecast deviation | 18:38 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261003-1838. Resolved 18:41 MDT. |
| Evening planning cycle | 18:40 | SUNSET | plan_written | Wrote public plan iris-20261003-1840. Resolved 18:42 MDT. |
🌅 Morning Cycle (12:17 AM) — iris-20261003-0017
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261002-0659
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:83.0,“outdoor_rh_min_pct”:13.0,“solar_peak_w_m2”:678.0,“cloud_cover_avg_pct”:1.0,“notes”:“Cool dawn then clear dry ramp. Prior self-score 5 versus deterministic anchor 1: safety credit was real, but 98/112 guardrail holds and unavailable physical, resource, fixed-panel, and DLI evidence limit causal credit; this plan separates live-edge response from forecast skill.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-02T06:55:00-06:00”,“end”:“2026-10-02T09:00:00-06:00”,“severity”:“medium”,“mitigation”:“heat lead and high churn penalty; no wetting while dawn VPD is near the low edge”},{“kind”:“vpd_high”,“start”:“2026-10-02T11:30:00-06:00”,“end”:“2026-10-02T19:30:00-06:00”,“severity”:“high”,“mitigation”:“band-coupled mist/fog assist in VENTILATE; hold recovery shoulder until live VPD clears high edge”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old… Result: Scoped window 00:17-07:02: planner score 2.8; nominal stress 0.63h with cold 3.11h and VPD-high 2.15h; no VPD-low or dew-risk hours. Safety held, but the low-wet bridge did not reduce cold/VPD-high exposure. Physical crop-band, fixed-panel, resource-cost, DLI and experiment-endpoint evidence unavailable; guardrail execution limited causal attribution. Score: 3/10
Hypothesis
Testing: Measure whether a low-wet pre-dawn bridge plus live-gated morning assist reduces controller-attributable VPD-high exposure without VPD-low or dew-risk. Expected outcome: Maintain 0h VPD-low and dew-risk; keep early cold/churn controlled, reduce actionable VPD-high during the Saturday dry ramp, and treat residual heat exposure as capacity-limited.
Setpoints
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.22750000000000004 | Safe current IDLE; no wetting while VPD is in-band before th |
| 05:30 | hyst 0.22750000000000004 | Pre-dawn outdoor 49-54F and VPD near 0.5; favor heat stabili |
| 08:30 | hyst 0.20750000000000002 | Sunrise ramp reaches VPD 1.0 by 09:00; open assist only as l |
| 11:30 | hyst 0.1975 | Dry peak begins near noon; use band-coupled assist while acc |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.9225; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.008; all 1.208; pulse 30; gap 60; wt 1.2 | Safe current IDLE; no wetting while VPD is in-band before th |
| 05:30 | s2 1.9225; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.008; all 1.208; pulse 30; gap 60; wt 1.2 | Pre-dawn outdoor 49-54F and VPD near 0.5; favor heat stabili |
| 08:30 | s2 1.6575000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.808; all 1.008; pulse 30; gap 45; wt 1.5333333333333332 | Sunrise ramp reaches VPD 1.0 by 09:00; open assist only as l |
| 11:30 | s2 1.5100000000000002; cool_exit 1.78; all_fans 1; dw_stress 1; engage 0.808; all 1.008; pulse 45; gap 30; wt 1.8000000000000003 | Dry peak begins near noon; use band-coupled assist while acc |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 9 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 00:15 | dwell_gate_ms | initial 330000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.4 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 114 |
| 00:15 | min_fog_on_s | initial 43.5 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 111 |
| 00:15 | mister_engage_delay_s | initial 55.5 |
| 00:15 | mister_water_budget_gal | initial 150 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.3200000000000003 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 3 |
| 00:15 | vent_prefer_temp_delta_f | initial 5 |
| 00:15 | vpd_watch_dwell_s | initial 82.5 |
| 05:30 | cold_vent_guard_delta_f | 9 → 10 |
| 05:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 05:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 05:30 | vent_prefer_temp_delta_f | 5 → 6 |
| 08:30 | cold_vent_guard_delta_f | 10 → 9 |
| 08:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 08:30 | dwell_gate_ms | 330000 → 270000 |
| 08:30 | fog_escalation_kpa | 0.35 → 0.25 |
| 08:30 | min_fog_off_s | 114 → 78 |
| 08:30 | min_fog_on_s | 43.5 → 57 |
| 08:30 | mister_all_delay_s | 111 → 93 |
| 08:30 | mister_engage_delay_s | 55.5 → 46.5 |
| 08:30 | mister_water_budget_gal | 150 → 180 |
| 08:30 | temp_hysteresis | 2.3200000000000003 → 1.96 |
| 08:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 08:30 | vent_prefer_temp_delta_f | 6 → 5 |
| 08:30 | vpd_watch_dwell_s | 82.5 → 67.5 |
| 11:30 | cold_vent_guard_delta_f | 9 → 8 |
| 11:30 | dwell_gate_ms | 270000 → 240000 |
| 11:30 | fog_escalation_kpa | 0.25 → 0.15 |
| 11:30 | min_fog_off_s | 78 → 54 |
| 11:30 | min_fog_on_s | 57 → 66 |
| 11:30 | mister_all_delay_s | 93 → 84 |
| 11:30 | mister_engage_delay_s | 46.5 → 42 |
| 11:30 | temp_hysteresis | 1.96 → 1.78 |
| 11:30 | vent_prefer_temp_delta_f | 5 → 4 |
| 11:30 | vpd_watch_dwell_s | 67.5 → 60 |
🌅 Morning Cycle (7:02 AM) — iris-20261003-0700
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261003-0017
Previous hypothesis: MIDNIGHT reset after evaluating iris-20261002-1842 at 5/10: its 0.008h scoped window was safe (0h stress and dew risk) but too short for causal or forecast-skill credit; deterministic anchor was unavailable. Current 66.3F/0.64 kPa VPD, 9.7F dew margin, IDLE, and all relays off support a low-wet bridge. Forecast risk is a rapid dry ramp to 84F/11% RH and 3.5 kPa VPD Saturday, but prior forecast VPD runs high and heat capacity is physics-limited. Keep pre-dawn wet duty at zero, then enable live-VPD-gated band-coupled assist from sunrise and stronger moisture/fog support by late morning without changing dispatcher-owned bands. Evidence is degraded by missing plan-coverage validation and static site context; physical crop-band, resource-cost, fixed-panel, DLI, and experiment-endpoint evidence remain unavailable. Result: Scoped window score 76.4 with nominal stress 1.03h: heat 6.54h, cold 3.87h, VPD-high 0h, VPD-low 0h; forecast missed badly (predicted peak 84F/RH 11%/solar 610 versus observed peak 85.8F/RH proxy 52%/solar 772). The predicted cold and VPD-high windows were not supported in the measured plan window; dawn moisture avoidance was safe, but the short/guardrail-limited window did not demonstrate the expected dry-ramp VPD benefit. Physical crop-band, fixed-panel, cost/resource, DLI, and experiment-endpoint evidence were unavailable. Score: 4/10
Hypothesis
Testing: Test live-gated morning moisture assist after a zero-wet dawn, retaining an evening recovery shoulder until measured VPD clears high edge. Expected outcome: Keep VPD-low and dew-risk at 0h; reduce controller-attributable VPD-high during the dry ramp while treating residual heat as capacity-limited.
Conditions
84.0°F
11.0%
610.0 W/m²
1.0%
Fresh dawn is 64F/0.59 kPa VPD after an overnight too-wet alert. Prior 0.224h plan window self-scored 5 vs deterministic anchor 1: safe but too short for causal credit; resource, physical crop-band, fixed-panel, and DLI evidence remain unavailable. Forecast VPD/RH is historically dry-biased, so use live recovery.
Expected stress windows
Low-wet dawn, long thermal lead, high churn penalty; no pre-wetting below live high edge.
Band-coupled assist near live high edge; peak fog/mist support in VENTILATE; retain recovery shoulder.
Parameter rationale
Avoid dawn wetting while making assist available before peak controller-attributable VPD-high stress.
Increase evaporation during live dry stress without increasing pulse-on time; widen after measured recovery.
Earlier bounded vent-fog assist while preserving the 8F dew floor.
Setpoints
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:55 | hyst 0.21750000000000003 | Dawn is 64F/0.59 VPD after a too-wet night; stabilize heat w |
| 09:30 | hyst 0.1975 | Morning solar/VPD ramp begins; open band-coupled assist as l |
| 12:30 | hyst 0.1875 | Peak forecast is 81-84F and 3.0-3.6 outdoor VPD; assist in V |
| 17:00 | hyst 0.1975 | Decline remains dry; maintain recovery through observed VPD |
| 19:30 | hyst 0.21750000000000003 | Evening VPD stays 1.9-1.6 forecast; taper after live recover |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:55 | s2 1.9225; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.103; all 1.303; pulse 30; gap 60; wt 1.2 | Dawn is 64F/0.59 VPD after a too-wet night; stabilize heat w |
| 09:30 | s2 1.775; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9530000000000001; all 1.153; pulse 30; gap 52.5; wt 1.6333333333333333 | Morning solar/VPD ramp begins; open band-coupled assist as l |
| 12:30 | s2 1.475; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9530000000000001; all 1.153; pulse 45; gap 33.75; wt 2.0166666666666666 | Peak forecast is 81-84F and 3.0-3.6 outdoor VPD; assist in V |
| 17:00 | s2 1.695; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.0030000000000001; all 1.203; pulse 37.5; gap 37.5; wt 1.9166666666666665 | Decline remains dry; maintain recovery through observed VPD |
| 19:30 | s2 1.8925; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.053; all 1.2530000000000001; pulse 30; gap 60; wt 1.5333333333333332 | Evening VPD stays 1.9-1.6 forecast; taper after live recover |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:55 | band_track_fraction | initial 0 |
| 06:55 | cold_vent_guard_delta_f | initial 9 |
| 06:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:55 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:55 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 06:55 | dwell_gate_ms | initial 300000 |
| 06:55 | enthalpy_close | initial 1 |
| 06:55 | enthalpy_open | initial -2 |
| 06:55 | fog_escalation_kpa | initial 0.35 |
| 06:55 | heat_hysteresis | initial 1 |
| 06:55 | min_fog_off_s | initial 114 |
| 06:55 | min_fog_on_s | initial 43.5 |
| 06:55 | mist_backoff_s | initial 600 |
| 06:55 | mist_max_closed_vent_s | initial 600 |
| 06:55 | mist_thermal_relief_s | initial 90 |
| 06:55 | mister_all_delay_s | initial 102 |
| 06:55 | mister_engage_delay_s | initial 51 |
| 06:55 | mister_water_budget_gal | initial 150 |
| 06:55 | night_vpd_bias_kpa | initial 0 |
| 06:55 | outdoor_staleness_max_s | initial 600 |
| 06:55 | sw_dwell_gate_enabled | initial 1 |
| 06:55 | sw_fog_closes_vent | initial 1 |
| 06:55 | sw_mister_closes_vent | initial 0 |
| 06:55 | sw_summer_vent_enabled | initial 1 |
| 06:55 | temp_hysteresis | initial 2.14 |
| 06:55 | vent_exchange_fraction | initial 0.3 |
| 06:55 | vent_prefer_dp_delta_f | initial 3 |
| 06:55 | vent_prefer_temp_delta_f | initial 5 |
| 06:55 | vpd_watch_dwell_s | initial 75 |
| 09:30 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.05 |
| 09:30 | dwell_gate_ms | 300000 → 240000 |
| 09:30 | fog_escalation_kpa | 0.35 → 0.2 |
| 09:30 | min_fog_off_s | 114 → 90 |
| 09:30 | min_fog_on_s | 43.5 → 52.5 |
| 09:30 | mister_all_delay_s | 102 → 84 |
| 09:30 | mister_engage_delay_s | 51 → 42 |
| 09:30 | temp_hysteresis | 2.14 → 1.78 |
| 09:30 | vpd_watch_dwell_s | 75 → 60 |
| 12:30 | dwell_gate_ms | 240000 → 210000 |
| 12:30 | fog_escalation_kpa | 0.2 → 0.18 |
| 12:30 | min_fog_off_s | 90 → 60 |
| 12:30 | min_fog_on_s | 52.5 → 63.75 |
| 12:30 | mister_all_delay_s | 84 → 75 |
| 12:30 | mister_engage_delay_s | 42 → 37.5 |
| 12:30 | temp_hysteresis | 1.78 → 1.6 |
| 12:30 | vpd_watch_dwell_s | 60 → 52.5 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 17:00 | dwell_gate_ms | 210000 → 240000 |
| 17:00 | fog_escalation_kpa | 0.18 → 0.2 |
| 17:00 | min_fog_off_s | 60 → 66 |
| 17:00 | min_fog_on_s | 63.75 → 61.5 |
| 17:00 | mister_all_delay_s | 75 → 84 |
| 17:00 | mister_engage_delay_s | 37.5 → 42 |
| 17:00 | temp_hysteresis | 1.6 → 1.78 |
| 17:00 | vpd_watch_dwell_s | 52.5 → 60 |
| 19:30 | cold_vent_guard_delta_f | 9 → 8 |
| 19:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.15 |
| 19:30 | dwell_gate_ms | 240000 → 300000 |
| 19:30 | fog_escalation_kpa | 0.2 → 0.35 |
| 19:30 | min_fog_off_s | 66 → 102 |
| 19:30 | min_fog_on_s | 61.5 → 48 |
| 19:30 | mister_all_delay_s | 84 → 102 |
| 19:30 | mister_engage_delay_s | 42 → 51 |
| 19:30 | temp_hysteresis | 1.78 → 2.14 |
| 19:30 | vent_prefer_temp_delta_f | 5 → 4 |
| 19:30 | vpd_watch_dwell_s | 60 → 75 |
🌆 Evening Cycle (6:41 PM) — iris-20261003-1838
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261003-0700
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:84.0,“outdoor_rh_min_pct”:11.0,“solar_peak_w_m2”:610.0,“cloud_cover_avg_pct”:1.0,“notes”:“Fresh dawn is 64F/0.59 kPa VPD after an overnight too-wet alert. Prior 0.224h plan window self-scored 5 vs deterministic anchor 1: safe but too short for causal credit; resource, physical crop-band, fixed-panel, and DLI evidence remain unavailable. Forecast VPD/RH is historically dry-biased, so use live recovery.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-03T06:55:00-06:00”,“end”:“2026-10-03T09:00:00-06:00”,“severity”:“medium”,“mitigation”:“Low-wet dawn, long thermal lead, high churn penalty; no pre-wetting below live high edge.”},{“kind”:“vpd_high”,“start”:“2026-10-03T10:30:00-06:00”,“end”:“2026-10-03T18:30:00-06:00”,“severity”:“high”,“mitigation”:“Band-coupled assist near live high edge; peak fog/mist support in VENTILATE; retain recovery shoulder… Result: Scoped 0.001h window scored 85.7 with 0h nominal stress and 0h dew risk; fresh telemetry was safe and IDLE, but the window was too short to establish the hypothesized evening recovery shoulder, low-wet overnight protection, or reduced heater-vent churn. Physical crop-band, fixed-panel, resource-cost, DLI, and causal experiment evidence were unavailable. Score: 6/10
Hypothesis
Testing: Forecast-deviation handoff: preserve low-wet night, then test live VPD-gated assist; do not claim causal benefit without physical evidence. Expected outcome: Keep dew-risk and VPD-low at 0h; reduce controller-attributable VPD-high during Sunday/Monday dry ramps while separating capacity-limited heat.
Setpoints
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:35 | hyst 0.1875 | Cloud miss; fresh IDLE cooling supports a low-wet night. |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:35 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 41.25; wt 1.7 | Cloud miss; fresh IDLE cooling supports a low-wet night. |
Sunday October 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:30 | hyst 0.1875 | Cold low-VPD dawn: lead heat, suppress wetting, avoid oscill |
| 10:30 | hyst 0.1875 | Dry ramp begins; open band-coupled assist near the live VPD |
| 13:30 | hyst 0.1875 | Sunday dry peak: prioritize VPD recovery; accept physics-lim |
| 18:30 | hyst 0.1875 | Keep recovery shoulder until observed VPD clears; do not unw |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:30 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 41.25; wt 1.7 | Cold low-VPD dawn: lead heat, suppress wetting, avoid oscill |
| 10:30 | s2 1.6425; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 41.25; wt 1.7 | Dry ramp begins; open band-coupled assist near the live VPD |
| 13:30 | s2 1.5250000000000001; cool_exit 1.6; all_fans 1; dw_stress 1; engage 1; all 1.2; pulse 37.5; gap 33.75; wt 1.7000000000000002 | Sunday dry peak: prioritize VPD recovery; accept physics-lim |
| 18:30 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 41.25; wt 1.7 | Keep recovery shoulder until observed VPD clears; do not unw |
Monday October 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | hyst 0.1875 | Monday dawn is cold first; keep the bridge low-wet before dr |
| 11:30 | hyst 0.1875 | Monday extreme dry ramp: early moisture assist; residual hea |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 41.25; wt 1.7 | Monday dawn is cold first; keep the bridge low-wet before dr |
| 11:30 | s2 1.5100000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 1; all 1.2; pulse 41.25; gap 30; wt 1.7666666666666666 | Monday extreme dry ramp: early moisture assist; residual hea |
Tuesday October 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:30 | hyst 0.1875 | Tuesday remains dry; retain live-edge assist without widenin |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:30 | s2 1.7; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1; all 1.2; pulse 33.75; gap 33.75; wt 1.7 | Tuesday remains dry; retain live-edge assist without widenin |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:35 | band_track_fraction | initial 0 |
| 18:35 | cold_vent_guard_delta_f | initial 9 |
| 18:35 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:35 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:35 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:35 | dwell_gate_ms | initial 210000 |
| 18:35 | enthalpy_close | initial 1 |
| 18:35 | enthalpy_open | initial -2 |
| 18:35 | fog_escalation_kpa | initial 0.25 |
| 18:35 | heat_hysteresis | initial 1 |
| 18:35 | min_fog_off_s | initial 72 |
| 18:35 | min_fog_on_s | initial 59.25 |
| 18:35 | mist_backoff_s | initial 600 |
| 18:35 | mist_max_closed_vent_s | initial 600 |
| 18:35 | mist_thermal_relief_s | initial 90 |
| 18:35 | mister_all_delay_s | initial 75 |
| 18:35 | mister_engage_delay_s | initial 37.5 |
| 18:35 | mister_water_budget_gal | initial 150 |
| 18:35 | night_vpd_bias_kpa | initial 0 |
| 18:35 | outdoor_staleness_max_s | initial 600 |
| 18:35 | sw_dwell_gate_enabled | initial 1 |
| 18:35 | sw_fog_closes_vent | initial 1 |
| 18:35 | sw_mister_closes_vent | initial 0 |
| 18:35 | sw_summer_vent_enabled | initial 1 |
| 18:35 | temp_hysteresis | initial 1.6 |
| 18:35 | vent_exchange_fraction | initial 0.3 |
| 18:35 | vent_prefer_dp_delta_f | initial 3 |
| 18:35 | vent_prefer_temp_delta_f | initial 5 |
| 18:35 | vpd_watch_dwell_s | initial 52.5 |
| 07:30 | cold_vent_guard_delta_f | 9 → 10 |
| 07:30 | direct_wet_stress_min_dew_margin_f | 8 → 8.5 |
| 07:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 07:30 | vent_prefer_temp_delta_f | 5 → 6 |
| 10:30 | cold_vent_guard_delta_f | 10 → 9 |
| 10:30 | direct_wet_stress_min_dew_margin_f | 8.5 → 8 |
| 10:30 | fog_escalation_kpa | 0.25 → 0.2 |
| 10:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 10:30 | vent_prefer_temp_delta_f | 6 → 5 |
| 13:30 | cold_vent_guard_delta_f | 9 → 8 |
| 13:30 | fog_escalation_kpa | 0.2 → 0.15 |
| 13:30 | min_fog_off_s | 72 → 60 |
| 13:30 | min_fog_on_s | 59.25 → 63.75 |
| 13:30 | mister_water_budget_gal | 150 → 180 |
| 13:30 | vent_prefer_temp_delta_f | 5 → 4 |
| 18:30 | cold_vent_guard_delta_f | 8 → 9 |
| 18:30 | fog_escalation_kpa | 0.15 → 0.25 |
| 18:30 | min_fog_off_s | 60 → 72 |
| 18:30 | min_fog_on_s | 63.75 → 59.25 |
| 18:30 | vent_prefer_temp_delta_f | 4 → 5 |
| 08:30 | cold_vent_guard_delta_f | 9 → 10 |
| 08:30 | direct_wet_stress_min_dew_margin_f | 8 → 8.5 |
| 08:30 | mister_water_budget_gal | 180 → 150 |
| 08:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 08:30 | vent_prefer_temp_delta_f | 5 → 6 |
| 11:30 | cold_vent_guard_delta_f | 10 → 8 |
| 11:30 | direct_wet_stress_min_dew_margin_f | 8.5 → 8 |
| 11:30 | fog_escalation_kpa | 0.25 → 0.15 |
| 11:30 | min_fog_off_s | 72 → 54 |
| 11:30 | min_fog_on_s | 59.25 → 66 |
| 11:30 | mister_water_budget_gal | 150 → 200 |
| 11:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 11:30 | vent_prefer_temp_delta_f | 6 → 4 |
| 09:30 | cold_vent_guard_delta_f | 8 → 9 |
| 09:30 | fog_escalation_kpa | 0.15 → 0.2 |
| 09:30 | min_fog_off_s | 54 → 60 |
| 09:30 | min_fog_on_s | 66 → 63.75 |
| 09:30 | mister_water_budget_gal | 200 → 180 |
| 09:30 | vent_prefer_temp_delta_f | 4 → 5 |
🌆 Evening Cycle (6:42 PM) — iris-20261003-1840
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261003-0700
Result: Safety held with 0 VPD-low hours and 0 dew-risk hours, but the scoped window still showed 1.49 cold-stress hours and did not demonstrate the planned evening VPD-recovery or churn benefit. Physical crop-band, fixed-panel, resource-cost, DLI, and experiment-endpoint evidence were unavailable; cost attribution remains unavailable. Score: 5/10
Hypothesis
Testing: Test a measured evening recovery shoulder, then low-wet cold-night posture before Sunday’s dry ramp. Expected outcome: Keep dew-risk and VPD-low at 0h, reduce post-sunset VPD-high after measured recovery, and reduce heater-vent churn without widening crop bands.
Conditions
82.0°F
17.0%
649.0 W/m²
1.0%
Completed iris-20261003-0017 scored 3 vs deterministic anchor 1: safety held, but cold/VPD-high persisted. Physical crop-band, fixed-panel, resource-cost, DLI and experiment evidence unavailable; guardrail execution limited causal credit. Current VPD 1.06 is just above edge with 11.9F dew margin; forecast is 51F/70% RH dawn then Sunday 82F/19% RH, VPD 3.01.
Expected stress windows
Keep band-coupled moisture available while dew margin >8F; taper only after observed VPD recovery.
Use long thermal lead, conservative outdoor exchange, high churn penalty, and no pre-dawn wetting.
Parameter rationale
Avoid overnight VPD-low/condensation while allowing recovery before taper.
Reduce heater-to-vent churn and cold-stress carryover without changing crop bands.
Keep a limited evening shoulder, then suppress unnecessary overnight wetting.
Setpoints
Saturday October 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:39 | hyst 0.1875 | Evening VPD is just above edge; keep a short recovery should |
| 23:55 | hyst 0.1875 | Forecast VPD falls below edge after midnight; taper wet duty |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:39 | s2 1.875; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 33.75; wt 1.8333333333333335 | Evening VPD is just above edge; keep a short recovery should |
| 23:55 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | Forecast VPD falls below edge after midnight; taper wet duty |
Sunday October 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 05:45 | hyst 0.1875 | Cold 51F dawn with low VPD: protect heat, avoid wetting; sun |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 05:45 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | Cold 51F dawn with low VPD: protect heat, avoid wetting; sun |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:39 | band_track_fraction | initial 0 |
| 18:39 | cold_vent_guard_delta_f | initial 10 |
| 18:39 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:39 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:39 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:39 | dwell_gate_ms | initial 210000 |
| 18:39 | enthalpy_close | initial 1 |
| 18:39 | enthalpy_open | initial -2 |
| 18:39 | fog_escalation_kpa | initial 0.25 |
| 18:39 | heat_hysteresis | initial 1 |
| 18:39 | min_fog_off_s | initial 60 |
| 18:39 | min_fog_on_s | initial 63.75 |
| 18:39 | mist_backoff_s | initial 600 |
| 18:39 | mist_max_closed_vent_s | initial 600 |
| 18:39 | mist_thermal_relief_s | initial 90 |
| 18:39 | mister_all_delay_s | initial 75 |
| 18:39 | mister_engage_delay_s | initial 37.5 |
| 18:39 | mister_water_budget_gal | initial 120 |
| 18:39 | night_vpd_bias_kpa | initial 0 |
| 18:39 | outdoor_staleness_max_s | initial 600 |
| 18:39 | sw_dwell_gate_enabled | initial 1 |
| 18:39 | sw_fog_closes_vent | initial 1 |
| 18:39 | sw_mister_closes_vent | initial 0 |
| 18:39 | sw_summer_vent_enabled | initial 1 |
| 18:39 | temp_hysteresis | initial 1.6 |
| 18:39 | vent_exchange_fraction | initial 0.3 |
| 18:39 | vent_prefer_dp_delta_f | initial 4 |
| 18:39 | vent_prefer_temp_delta_f | initial 6 |
| 18:39 | vpd_watch_dwell_s | initial 52.5 |
| 23:55 | cold_vent_guard_delta_f | 10 → 12 |
| 23:55 | min_fog_off_s | 60 → 72 |
| 23:55 | min_fog_on_s | 63.75 → 59.25 |
| 23:55 | vent_prefer_dp_delta_f | 4 → 5 |
| 23:55 | vent_prefer_temp_delta_f | 6 → 8 |
| 05:45 | cold_vent_guard_delta_f | 12 → 13 |
| 05:45 | vent_prefer_dp_delta_f | 5 → 6 |
| 05:45 | vent_prefer_temp_delta_f | 8 → 9 |
End-of-Day Summary
Climate
62.3–85.8°F; avg 71.9°F
0.52–1.93 kPa; avg 0.91 kPa
51.8–75.4%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 2.2h
- VPD stress (>2.0 kPa): 8.5h
- Cold stress (<55°F): 14.3h
Economics
Not available
USD 0.15
USD 0.470
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 36 min | Primary exhaust runtime. |
| Fan 2 | 43 min | Secondary exhaust runtime. |
| Vent | 79 min | Intake vent runtime. |
| Fog | 96 min | Fogger runtime. |
| Heat 1 electric | 451 min | Electric heater runtime. |
| Heat 2 gas | 14 min | Gas heater runtime. |
| Grow lights | 888 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.26h | Center mister runtime. |
Water
- Total: 98 gal
- Mister: 48 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 76% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 80% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 78% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Foliage appears green and healthy. || Lime tree appears healthy with no visible signs of stress. || Lime tree in the west zone looks healthy and green. Soil moisture is adequate. || Lime tree in the west zone looks healthy. Soil moisture is adequate. || Lime tree looks generally healthy, but some leaves appear slightly pale. || Tree appears healthy with green foliage. || Tree looks generally healthy, but hard to assess fully in IR light. || Vegetative growth looks normal, no obvious stress.
Hanging orchids appear healthy with no visible signs of stress. || Hanging orchids appear healthy, one is flowering. || Orchid appears healthy with green leaves and extensive root system. || Orchid is blooming beautifully with vibrant purple flowers. || Orchid is blooming with vibrant purple flowers. || Orchids appear healthy with no visible signs of stress. || Orchids appear healthy, hanging in the center zone. || Orchids hanging in the center appear generally healthy, though some lower leaves might be slightly yellowing. Hard to tell definitively from this distance.
Seedlings appear healthy and are establishing well in the hydroponic system. || Seedlings appear healthy in the hydroponic system. || Seedlings appear healthy under grow lights. || Seedlings appear healthy, but are small and difficult to assess in detail.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 80.6°F | 1.16 kPa | 68.4% |
| 13:00 | 83.2°F | 1.32 kPa | 67.8% |
| 14:00 | 83.9°F | 1.33 kPa | 68.5% |
| 15:00 | 83.7°F | 1.27 kPa | 68.6% |
| 16:00 | 83.0°F | 1.19 kPa | 69.2% |
| 17:00 | 82.8°F | 1.12 kPa | 70.9% |
| 18:00 | 80.8°F | 1.03 kPa | 71.5% |
| 19:00 | 78.4°F | 0.95 kPa | 71.6% |
| 20:00 | 75.6°F | 0.83 kPa | 72.9% |
| 21:00 | 73.1°F | 0.76 kPa | 73.2% |
| 22:00 | 69.9°F | 0.74 kPa | 70.2% |
| 23:00 | 67.7°F | 0.69 kPa | 70.4% |
| 00:00 | 65.6°F | 0.66 kPa | 69.2% |
| 01:00 | 64.1°F | 0.63 kPa | 69.4% |
| 02:00 | 63.1°F | 0.63 kPa | 68.4% |
| 03:00 | 62.7°F | 0.62 kPa | 68.3% |
| 04:00 | 62.8°F | 0.57 kPa | 70.9% |
| 05:00 | 62.6°F | 0.55 kPa | 71.8% |
| 06:00 | 62.6°F | 0.55 kPa | 71.8% |
| 07:00 | 66.7°F | 0.81 kPa | 64.1% |
| 08:00 | 68.8°F | 0.92 kPa | 62.2% |
| 09:00 | 70.9°F | 0.98 kPa | 62.2% |
| 10:00 | 71.4°F | 1.08 kPa | 58.8% |
| 11:00 | 74.2°F | 1.09 kPa | 62.6% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-09-27 | 2.6h | 9.3h | 13.5h |
| 2026-09-28 | 0.0h | 9.7h | 12.7h |
| 2026-09-29 | 1.9h | 7.8h | 13.2h |
| 2026-09-30 | 0.0h | 9.4h | 14.1h |
| 2026-10-01 | 2.7h | 8.4h | 13.4h |
| 2026-10-02 | 2.5h | 7.8h | 13.7h |
| 2026-10-03 | 2.3h | 8.5h | 14.3h |