October 11, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
3
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261011-0016. Resolved 00:17 MDT. |
| Morning planning cycle | 07:09 | SUNRISE | plan_written | Wrote public plan iris-20261011-0709. Resolved 07:11 MDT. |
| Solar peak planning checkpoint | 12:48 | SOLAR_MAX | acked | Acknowledged: No tactical nudge: live solar 410 W/m2 is below the bias-corrected near-term forecast (~552), not an overshoot. Indoor VPD is rising (1.04→1.37 kPa over 30 min) with healthy 13.7F dew margin, but fresh state is IDLE with all climate relays off and the active plan covers the afternoon from 14:30. Preserve the scheduled posture rather than stacking a fog write; reassess at the next checkpoint. Resolved 12:49 MDT. |
| Peak Stress | 14:49 | TRANSITION | acked | Acknowledged: Peak stress is tracking the governing plan: fresh climate is 84.8F/1.13 kPa with 9.9F dew margin, ESP32 is IDLE, and all climate relays are off. Dispatcher authority shows only 0.80F temp edge error and no VPD band error; outdoor 79.1F/30% RH is less dry than forecast. Preserve the scheduled evening taper; no tactical write warranted. Resolved 14:50 MDT. |
| Decline | 17:27 | TRANSITION | acked | Acknowledged: Decline is tracking the existing taper: IDLE, house VPD 0.93 kPa, dew margin 9.0F, all climate equipment off; east 1.16 kPa is localized. Keep scheduled 18:30 and 21:30 evening unwind; no immediate change. Resolved 17:28 MDT. |
| Forecast deviation | 18:00 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261011-1800. Resolved 18:02 MDT. |
| Evening planning cycle | 18:28 | SUNSET | plan_written | Wrote public plan iris-20261011-1828. Resolved 18:30 MDT. |
🌅 Morning Cycle (12:17 AM) — iris-20261011-0016
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261010-1425
Previous hypothesis: Fresh MCP evidence at 14:25 MDT shows 81.5F, VPD 1.19 kPa, 11.8F dew margin, IDLE, and every climate relay off; the 3h trace is smooth. The trigger spike (observed VPD 2.06 vs 2.88 forecast; wind 1.81 vs 22 mph) is a weather/forecast miss, not equipment failure or a regime change. It agrees with the established forecast direction: VPD is commonly forecast high by about 0.22 kPa and temperature low, so raw dry/heat pressure is de-weighted. The replacement keeps a measured-VPD-gated, moderate near-term dry readiness, adds an evening recovery shoulder, supports Sunday’s cloudy-to-dry peak, then Monday’s clearer severe dry ramp, and tapers for the cold/wet Tuesday dawn. It does not chase target distance, widen dispatcher-owned crop bands, or infer DLI/resource/crop outcome proof… Result: Scoped 0.287h window with 12 missed rows and no causal endpoint. Window evidence showed zero VPD-low/VPD-high and healthy dew margin, but temperature/cold exposure remained in the short scorecard; current recovery and safe wet-off posture are persistence/safety evidence, not proof of tuning efficacy. Resource, physical crop, firmware-consumption, coverage, DLI, and experiment-endpoint evidence unavailable. Score: 5/10
Hypothesis
Testing: Test low-wet overnight recovery followed by measured-VPD moisture staging at the early dry ramp. Expected outcome: Dew margin stays >=8F, VPD-low remains 0h overnight, and moisture assist is available by 10:30 without unnecessary relay churn.
Setpoints
Sunday October 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.21750000000000003 | Recovered VPD; suppress overnight wetting and protect dew ma |
| 04:30 | hyst 0.21750000000000003 | Cloudy 59-60F pre-dawn; avoid mist-driven humidity and heate |
| 07:00 | hyst 0.20750000000000002 | Begin measured dawn readiness; keep assistance conditional o |
| 10:30 | hyst 0.1975 | Forecast VPD reaches 1.44; enable band-coupled assist before |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.85; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.907; all 1.057; pulse 30; gap 60; wt 1.2 | Recovered VPD; suppress overnight wetting and protect dew ma |
| 04:30 | s2 1.85; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.907; all 1.057; pulse 30; gap 60; wt 1.2 | Cloudy 59-60F pre-dawn; avoid mist-driven humidity and heate |
| 07:00 | s2 1.7025000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.857; all 1.057; pulse 30; gap 52.5; wt 1.4 | Begin measured dawn readiness; keep assistance conditional o |
| 10:30 | s2 1.555; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.807; all 1.0070000000000001; pulse 33.75; gap 37.5; wt 1.6333333333333333 | Forecast VPD reaches 1.44; enable band-coupled assist before |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 8 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 00:15 | dwell_gate_ms | initial 300000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.4 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 114 |
| 00:15 | min_fog_on_s | initial 43.5 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 102 |
| 00:15 | mister_engage_delay_s | initial 51 |
| 00:15 | mister_water_budget_gal | initial 120 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.14 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 3 |
| 00:15 | vent_prefer_temp_delta_f | initial 4 |
| 00:15 | vpd_watch_dwell_s | initial 75 |
| 07:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 07:00 | dwell_gate_ms | 300000 → 270000 |
| 07:00 | fog_escalation_kpa | 0.4 → 0.3 |
| 07:00 | min_fog_off_s | 114 → 90 |
| 07:00 | min_fog_on_s | 43.5 → 52.5 |
| 07:00 | mister_all_delay_s | 102 → 93 |
| 07:00 | mister_engage_delay_s | 51 → 46.5 |
| 07:00 | mister_water_budget_gal | 120 → 150 |
| 07:00 | temp_hysteresis | 2.14 → 1.96 |
| 07:00 | vpd_watch_dwell_s | 75 → 67.5 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 10:30 | dwell_gate_ms | 270000 → 240000 |
| 10:30 | fog_escalation_kpa | 0.3 → 0.2 |
| 10:30 | min_fog_off_s | 90 → 66 |
| 10:30 | min_fog_on_s | 52.5 → 61.5 |
| 10:30 | mister_all_delay_s | 93 → 84 |
| 10:30 | mister_engage_delay_s | 46.5 → 42 |
| 10:30 | mister_water_budget_gal | 150 → 180 |
| 10:30 | temp_hysteresis | 1.96 → 1.78 |
| 10:30 | vpd_watch_dwell_s | 67.5 → 60 |
🌅 Morning Cycle (7:11 AM) — iris-20261011-0709
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261011-0016
Previous hypothesis: Current VPD has recovered to 0.72 kPa with 9.8F dew margin and all climate relays off, while the forecast shifts from cloudy pre-dawn to a dry late-morning ramp. The prior iris-20261010-1829 window was only 0.239h with zero scored stress/compliance and 12 missed rows, so its self-score 5.7 is persistence/safety evidence, not causal proof. Keep overnight wetting suppressed, preserve heater/vent stability, and stage live-confirmed band-coupled moisture by the early dry ramp. Prediction: no VPD-low or dew-risk carryover overnight; at 10:30, moisture assist is available near the served VPD edge without target chasing. Result: Daily scorecard: planner score 76.6 with binary compliance 5.5%, temperature 30.0%, VPD 61.5%; nominal stress 18.52h, including cold 10.58h, VPD-high 6.57h, heat 1.37h, VPD-low 0h; dew-risk 0h and minimum dew margin 8.7F. Prediction errors: outdoor peak 84.0F vs 84.3F close; RH-min proxy 19% vs 52% materially wrong; solar 611 vs 766 W/m2 undercalled. The plan’s dry-ramp rationale was not causally testable: audit shows 39 missed rows and 32 already-at-value, including missed fog_escalation 0.15, mister engage delay 30s, and pulse gap 22s. Zero VPD-low/dew risk was achieved, but VPD-high and cold exposure remained high. Treat this as safety/persistence evidence, not proof of tuning efficacy; physical crop, resource/cost, firmware-consumption, coverage, DLI, and experiment-endpoint evidence were unavailable. Score: 4/10
Hypothesis
Testing: Guarded dawn to live-confirmed band-coupled dry-ramp moisture, with an evening recovery shoulder. Expected outcome: Keep VPD-low and dew-risk at 0h; reduce VPD-high below 4h despite physics-limited heat, without unnecessary relay churn. Physical crop/resource endpoints remain unavailable.
Conditions
84.0°F
19.0%
611.0 W/m²
38.0%
Cool cloudy dawn, then a clear dry ramp to 84F and VPD 3.26. Prior completed plan scored 3 vs deterministic anchor 1; the two-point gap reflects safety/persistence only because its 0.241h window had 12 missed rows and no causal endpoint.
Expected stress windows
Use live-edge band-coupled wet assist: engage excess 0.05, all-zone excess 0.25, fog excess 0.15-0.20.
Pre-cool and ventilate early; accept physics-limited heat while preserving moisture assist and dew floor.
Parameter rationale
Increase evaporative delivery only during the dry ramp while keeping VPD-low and dew-risk at 0h.
Offer earlier high-leverage assist in the permitted fog window without target chasing.
Make S1 moisture available near the served edge before VPD-high accumulates.
Setpoints
Sunday October 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:05 | hyst 0.21750000000000003 | Guarded dawn: live VPD 0.68, IDLE, 10F dew margin; de-weight |
| 10:30 | hyst 0.1975 | Morning ramp: switch to band-coupled wet assist as solar cle |
| 14:30 | hyst 0.1875 | Peak stress: pre-cool, ventilate, and keep moisture availabl |
| 18:30 | hyst 0.1975 | Decline: retain a recovery shoulder; do not unwind on clock |
| 21:30 | hyst 0.21750000000000003 | Evening taper: widen wet posture only after measured VPD rec |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:05 | s2 1.7425; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.105; all 1.205; pulse 30; gap 60; wt 1.3666666666666667 | Guarded dawn: live VPD 0.68, IDLE, 10F dew margin; de-weight |
| 10:30 | s2 1.55; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.9550000000000001; all 1.155; pulse 48.75; gap 33.75; wt 1.7999999999999998 | Morning ramp: switch to band-coupled wet assist as solar cle |
| 14:30 | s2 1.4475000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9550000000000001; all 1.155; pulse 60; gap 30; wt 1.9333333333333331 | Peak stress: pre-cool, ventilate, and keep moisture availabl |
| 18:30 | s2 1.6675; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.985; all 1.155; pulse 45; gap 41.25; wt 1.7000000000000002 | Decline: retain a recovery shoulder; do not unwind on clock |
| 21:30 | s2 1.8299999999999998; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.055; all 1.205; pulse 30; gap 60; wt 1.4000000000000001 | Evening taper: widen wet posture only after measured VPD rec |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:05 | band_track_fraction | initial 0 |
| 07:05 | cold_vent_guard_delta_f | initial 8 |
| 07:05 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:05 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:05 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 07:05 | dwell_gate_ms | initial 300000 |
| 07:05 | enthalpy_close | initial 1 |
| 07:05 | enthalpy_open | initial -2 |
| 07:05 | fog_escalation_kpa | initial 0.35 |
| 07:05 | heat_hysteresis | initial 1 |
| 07:05 | min_fog_off_s | initial 102 |
| 07:05 | min_fog_on_s | initial 48 |
| 07:05 | mist_backoff_s | initial 600 |
| 07:05 | mist_max_closed_vent_s | initial 600 |
| 07:05 | mist_thermal_relief_s | initial 90 |
| 07:05 | mister_all_delay_s | initial 102 |
| 07:05 | mister_engage_delay_s | initial 51 |
| 07:05 | mister_water_budget_gal | initial 180 |
| 07:05 | night_vpd_bias_kpa | initial 0 |
| 07:05 | outdoor_staleness_max_s | initial 600 |
| 07:05 | sw_dwell_gate_enabled | initial 1 |
| 07:05 | sw_fog_closes_vent | initial 1 |
| 07:05 | sw_mister_closes_vent | initial 0 |
| 07:05 | sw_summer_vent_enabled | initial 1 |
| 07:05 | temp_hysteresis | initial 2.14 |
| 07:05 | vent_exchange_fraction | initial 0.3 |
| 07:05 | vent_prefer_dp_delta_f | initial 3 |
| 07:05 | vent_prefer_temp_delta_f | initial 4 |
| 07:05 | vpd_watch_dwell_s | initial 75 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.05 |
| 10:30 | dwell_gate_ms | 300000 → 240000 |
| 10:30 | fog_escalation_kpa | 0.35 → 0.2 |
| 10:30 | min_fog_off_s | 102 → 60 |
| 10:30 | min_fog_on_s | 48 → 63.75 |
| 10:30 | mister_all_delay_s | 102 → 84 |
| 10:30 | mister_engage_delay_s | 51 → 42 |
| 10:30 | temp_hysteresis | 2.14 → 1.78 |
| 10:30 | vpd_watch_dwell_s | 75 → 60 |
| 14:30 | dwell_gate_ms | 240000 → 210000 |
| 14:30 | fog_escalation_kpa | 0.2 → 0.15 |
| 14:30 | min_fog_off_s | 60 → 54 |
| 14:30 | min_fog_on_s | 63.75 → 66 |
| 14:30 | mister_all_delay_s | 84 → 75 |
| 14:30 | mister_engage_delay_s | 42 → 37.5 |
| 14:30 | temp_hysteresis | 1.78 → 1.6 |
| 14:30 | vpd_watch_dwell_s | 60 → 52.5 |
| 18:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.08 |
| 18:30 | dwell_gate_ms | 210000 → 240000 |
| 18:30 | fog_escalation_kpa | 0.15 → 0.2 |
| 18:30 | min_fog_off_s | 54 → 72 |
| 18:30 | min_fog_on_s | 66 → 59.25 |
| 18:30 | mister_all_delay_s | 75 → 84 |
| 18:30 | mister_engage_delay_s | 37.5 → 42 |
| 18:30 | temp_hysteresis | 1.6 → 1.78 |
| 18:30 | vpd_watch_dwell_s | 52.5 → 60 |
| 21:30 | direct_wet_stress_vpd_margin_kpa | 0.08 → 0.15 |
| 21:30 | dwell_gate_ms | 240000 → 300000 |
| 21:30 | fog_escalation_kpa | 0.2 → 0.35 |
| 21:30 | min_fog_off_s | 72 → 102 |
| 21:30 | min_fog_on_s | 59.25 → 48 |
| 21:30 | mister_all_delay_s | 84 → 102 |
| 21:30 | mister_engage_delay_s | 42 → 51 |
| 21:30 | temp_hysteresis | 1.78 → 2.14 |
| 21:30 | vpd_watch_dwell_s | 60 → 75 |
🌆 Evening Cycle (6:02 PM) — iris-20261011-1800
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261011-0709
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:84.0,“outdoor_rh_min_pct”:19.0,“solar_peak_w_m2”:611.0,“cloud_cover_avg_pct”:38.0,“notes”:“Cool cloudy dawn, then a clear dry ramp to 84F and VPD 3.26. Prior completed plan scored 3 vs deterministic anchor 1; the two-point gap reflects safety/persistence only because its 0.241h window had 12 missed rows and no causal endpoint.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-10-11T10:30:00-06:00”,“end”:“2026-10-11T19:00:00-06:00”,“severity”:“high”,“mitigation”:“Use live-edge band-coupled wet assist: engage excess 0.05, all-zone excess 0.25, fog excess 0.15-0.20.”},{“kind”:“heat”,“start”:“2026-10-11T13:00:00-06:00”,“end”:“2026-10-11T18:00:00-06:00”,“severity”:“medium”,“mitigation”:“Pre-cool and ventilate early; accept physics-limited heat while preserving moisture assist and dew floor… Result: Scoped 0.019h window: planner score 84.4, binary temp and VPD compliance 0/100 fields as recorded, nominal stress 0.00h, VPD compliance 100%, no dew-risk exposure. Fresh recovery to IDLE with all climate relays off supports safety/persistence only; the window was too short for causal efficacy, resource/cost, physical crop, firmware-consumption, coverage, DLI, and experiment-endpoint evidence. Forecast-deviation diagnosis matched recovered weather rather than equipment failure. Score: 5/10
Hypothesis
Testing: Test forecast-bias deweighting with current-first recovery, measured-VPD gating, and a Monday dry-ramp posture. Expected outcome: Keep dew-risk and VPD-low exposure at 0h; reduce Monday VPD-high exposure versus the prior 6.57h daily diagnostic without chasing target distance or claiming physical crop proof.
Setpoints
Sunday October 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | hyst 0.21750000000000003 | Fresh VPD 0.98 and IDLE; deviation recovered, so preserve lo |
| 21:30 | hyst 0.21750000000000003 | Retain a small recovery shoulder without carrying raw foreca |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | s2 1.9225; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.125; all 1.325; pulse 30; gap 60; wt 1.4833333333333334 | Fresh VPD 0.98 and IDLE; deviation recovered, so preserve lo |
| 21:30 | s2 1.8925; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.075; all 1.275; pulse 30; gap 60; wt 1.5833333333333335 | Retain a small recovery shoulder without carrying raw foreca |
Monday October 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | hyst 0.2025 | Precondition the measured ramp before corrected VPD reaches |
| 11:30 | hyst 0.1975 | Corrected forecast supports high VPD; use bounded vent-mist/ |
| 17:30 | hyst 0.2025 | Hold moisture through peak exit; unwind only after measured |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | s2 1.6275000000000002; cool_exit 1.87; all_fans 0; dw_stress 1; engage 1.025; all 1.225; pulse 30; gap 37.5; wt 1.85 | Precondition the measured ramp before corrected VPD reaches |
| 11:30 | s2 1.5100000000000002; cool_exit 1.78; all_fans 1; dw_stress 1; engage 1.025; all 1.225; pulse 41.25; gap 30; wt 2.0166666666666666 | Corrected forecast supports high VPD; use bounded vent-mist/ |
| 17:30 | s2 1.715; cool_exit 1.87; all_fans 0; dw_stress 1; engage 1.025; all 1.275; pulse 33.75; gap 37.5; wt 1.8833333333333333 | Hold moisture through peak exit; unwind only after measured |
Tuesday October 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | hyst 0.22750000000000004 | Cold/wet front and VPD-low risk: suppress wet assist and pro |
| 13:00 | hyst 0.20750000000000002 | Use moderate midday recovery only as Tuesday solar and VPD r |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | s2 1.9525000000000001; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.225; all 1.375; pulse 30; gap 60; wt 1.3833333333333333 | Cold/wet front and VPD-low risk: suppress wet assist and pro |
| 13:00 | s2 1.76; cool_exit 1.96; all_fans 0; dw_stress 1; engage 1.075; all 1.275; pulse 30; gap 48.75; wt 1.75 | Use moderate midday recovery only as Tuesday solar and VPD r |
Wednesday October 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 17:00 | hyst 0.22750000000000004 | Cold saturated passage: zero planned wet duty and high dew f |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 17:00 | s2 2.0700000000000003; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.275; all 1.375; pulse 30; gap 60; wt 1.3166666666666667 | Cold saturated passage: zero planned wet duty and high dew f |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:00 | band_track_fraction | initial 0 |
| 18:00 | cold_vent_guard_delta_f | initial 8 |
| 18:00 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:00 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:00 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 18:00 | dwell_gate_ms | initial 300000 |
| 18:00 | enthalpy_close | initial 1 |
| 18:00 | enthalpy_open | initial -2 |
| 18:00 | fog_escalation_kpa | initial 0.4 |
| 18:00 | heat_hysteresis | initial 1 |
| 18:00 | min_fog_off_s | initial 114 |
| 18:00 | min_fog_on_s | initial 46.875 |
| 18:00 | mist_backoff_s | initial 600 |
| 18:00 | mist_max_closed_vent_s | initial 600 |
| 18:00 | mist_thermal_relief_s | initial 90 |
| 18:00 | mister_all_delay_s | initial 102 |
| 18:00 | mister_engage_delay_s | initial 51 |
| 18:00 | mister_water_budget_gal | initial 100 |
| 18:00 | night_vpd_bias_kpa | initial 0 |
| 18:00 | outdoor_staleness_max_s | initial 600 |
| 18:00 | sw_dwell_gate_enabled | initial 1 |
| 18:00 | sw_fog_closes_vent | initial 1 |
| 18:00 | sw_mister_closes_vent | initial 0 |
| 18:00 | sw_summer_vent_enabled | initial 1 |
| 18:00 | temp_hysteresis | initial 2.14 |
| 18:00 | vent_exchange_fraction | initial 0.3 |
| 18:00 | vent_prefer_dp_delta_f | initial 3 |
| 18:00 | vent_prefer_temp_delta_f | initial 4 |
| 18:00 | vpd_watch_dwell_s | initial 75 |
| 21:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 21:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 21:30 | min_fog_off_s | 114 → 102 |
| 21:30 | min_fog_on_s | 46.875 → 48 |
| 21:30 | mister_water_budget_gal | 100 → 120 |
| 08:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 08:30 | dwell_gate_ms | 300000 → 255000 |
| 08:30 | fog_escalation_kpa | 0.35 → 0.25 |
| 08:30 | min_fog_off_s | 102 → 66 |
| 08:30 | min_fog_on_s | 48 → 61.5 |
| 08:30 | mister_all_delay_s | 102 → 88.5 |
| 08:30 | mister_engage_delay_s | 51 → 44.25 |
| 08:30 | mister_water_budget_gal | 120 → 180 |
| 08:30 | temp_hysteresis | 2.14 → 1.87 |
| 08:30 | vpd_watch_dwell_s | 75 → 63.75 |
| 11:30 | dwell_gate_ms | 255000 → 240000 |
| 11:30 | fog_escalation_kpa | 0.25 → 0.18 |
| 11:30 | min_fog_off_s | 66 → 54 |
| 11:30 | min_fog_on_s | 61.5 → 66 |
| 11:30 | mister_all_delay_s | 88.5 → 84 |
| 11:30 | mister_engage_delay_s | 44.25 → 42 |
| 11:30 | temp_hysteresis | 1.87 → 1.78 |
| 11:30 | vpd_watch_dwell_s | 63.75 → 60 |
| 17:30 | dwell_gate_ms | 240000 → 255000 |
| 17:30 | fog_escalation_kpa | 0.18 → 0.22 |
| 17:30 | min_fog_off_s | 54 → 66 |
| 17:30 | min_fog_on_s | 66 → 61.5 |
| 17:30 | mister_all_delay_s | 84 → 88.5 |
| 17:30 | mister_engage_delay_s | 42 → 44.25 |
| 17:30 | mister_water_budget_gal | 180 → 160 |
| 17:30 | temp_hysteresis | 1.78 → 1.87 |
| 17:30 | vpd_watch_dwell_s | 60 → 63.75 |
| 08:30 | cold_vent_guard_delta_f | 8 → 9 |
| 08:30 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 08:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.25 |
| 08:30 | dwell_gate_ms | 255000 → 330000 |
| 08:30 | fog_escalation_kpa | 0.22 → 0.45 |
| 08:30 | min_fog_off_s | 66 → 126 |
| 08:30 | min_fog_on_s | 61.5 → 46.875 |
| 08:30 | mister_all_delay_s | 88.5 → 111 |
| 08:30 | mister_engage_delay_s | 44.25 → 55.5 |
| 08:30 | mister_water_budget_gal | 160 → 100 |
| 08:30 | temp_hysteresis | 1.87 → 2.3200000000000003 |
| 08:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 08:30 | vent_prefer_temp_delta_f | 4 → 5 |
| 08:30 | vpd_watch_dwell_s | 63.75 → 82.5 |
| 13:00 | cold_vent_guard_delta_f | 9 → 8 |
| 13:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 13:00 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.1 |
| 13:00 | dwell_gate_ms | 330000 → 270000 |
| 13:00 | fog_escalation_kpa | 0.45 → 0.3 |
| 13:00 | min_fog_off_s | 126 → 84 |
| 13:00 | min_fog_on_s | 46.875 → 54.75 |
| 13:00 | mister_all_delay_s | 111 → 93 |
| 13:00 | mister_engage_delay_s | 55.5 → 46.5 |
| 13:00 | mister_water_budget_gal | 100 → 140 |
| 13:00 | temp_hysteresis | 2.3200000000000003 → 1.96 |
| 13:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 13:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 13:00 | vpd_watch_dwell_s | 82.5 → 67.5 |
| 17:00 | cold_vent_guard_delta_f | 8 → 9 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.3 |
| 17:00 | dwell_gate_ms | 270000 → 330000 |
| 17:00 | fog_escalation_kpa | 0.3 → 0.5 |
| 17:00 | min_fog_off_s | 84 → 138 |
| 17:00 | min_fog_on_s | 54.75 → 46.875 |
| 17:00 | mister_all_delay_s | 93 → 111 |
| 17:00 | mister_engage_delay_s | 46.5 → 55.5 |
| 17:00 | mister_water_budget_gal | 140 → 100 |
| 17:00 | temp_hysteresis | 1.96 → 2.3200000000000003 |
| 17:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 17:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 17:00 | vpd_watch_dwell_s | 67.5 → 82.5 |
🌆 Evening Cycle (6:30 PM) — iris-20261011-1828
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261011-0709
Result: Scoped 0.242h window: 0.00h nominal stress, temp compliance 0%, VPD compliance 100%, no VPD-high/VPD-low or dew-risk exposure; greenhouse was IDLE with climate relays off and dew margin about 8.6F at handoff. Audit had 40 missed rows and 19 already-at-value; cost, physical crop, firmware-consumption, coverage, DLI, and experiment-endpoint evidence unavailable. Safety/persistence evidence only, not causal efficacy. Score: 5/10
Hypothesis
Testing: Test recovery-first taper plus anti-churn overnight posture after a VPD-high day. Expected outcome: Keep dp_risk_hours at 0 and added VPD-low stress below 0.5h; reduce heater-vent churn and avoid forecast-driven wetting while retaining live-edge recovery.
Conditions
72.0°F
30.0%
0.0 W/m²
70.0%
Current indoor VPD 0.93 is just below the 0.99 high edge with 9.4F dew margin and IDLE relays. The next 12h is a cool, no-solar fall to 58F; raw outdoor VPD is de-weighted because recent bias is positive. Prior completed plan self-score 5 versus deterministic anchor 1; the 4-point gap reflects safety/persistence evidence from a short, missed-row window, not causal efficacy.
Expected stress windows
Use high relay-churn penalty, longer thermal lead, conservative vent/moisture posture; preserve dew margin.
Keep a short live-edge recovery shoulder, then taper only after measured VPD remains below the high edge.
Parameter rationale
Reduce heater-to-vent churn and overnight cold exposure without changing dispatcher-owned bands.
Prevent overnight wet carryover while retaining live-edge recovery if measured VPD re-enters high stress.
Suppress heavy wetting overnight and keep dew-risk at zero.
Setpoints
Sunday October 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:25 | hyst 0.2125 | Evening settle: short live-edge recovery, then taper after m |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:25 | s2 1.935; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.998; all 1.198; pulse 30; gap 48.75; wt 1.4866666666666666 | Evening settle: short live-edge recovery, then taper after m |
Monday October 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.22749999999999998 | Midnight posture: protect heat stability and dew margin; wet |
| 05:30 | hyst 0.23249999999999998 | Pre-dawn: preserve heat through the coldest window; avoid fo |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 2.04; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.0979999999999999; all 1.248; pulse 30; gap 60; wt 1.1866666666666665 | Midnight posture: protect heat stability and dew margin; wet |
| 05:30 | s2 1.9675000000000002; cool_exit 2.41; all_fans 0; dw_stress 0; engage 1.0979999999999999; all 1.248; pulse 30; gap 60; wt 1.1333333333333333 | Pre-dawn: preserve heat through the coldest window; avoid fo |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:25 | band_track_fraction | initial 0 |
| 18:25 | cold_vent_guard_delta_f | initial 9 |
| 18:25 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:25 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:25 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:25 | dwell_gate_ms | initial 285000 |
| 18:25 | enthalpy_close | initial 1 |
| 18:25 | enthalpy_open | initial -2 |
| 18:25 | fog_escalation_kpa | initial 0.2 |
| 18:25 | heat_hysteresis | initial 1 |
| 18:25 | min_fog_off_s | initial 84 |
| 18:25 | min_fog_on_s | initial 54.75 |
| 18:25 | mist_backoff_s | initial 600 |
| 18:25 | mist_max_closed_vent_s | initial 600 |
| 18:25 | mist_thermal_relief_s | initial 90 |
| 18:25 | mister_all_delay_s | initial 97.5 |
| 18:25 | mister_engage_delay_s | initial 48.75 |
| 18:25 | mister_water_budget_gal | initial 140 |
| 18:25 | night_vpd_bias_kpa | initial 0 |
| 18:25 | outdoor_staleness_max_s | initial 600 |
| 18:25 | sw_dwell_gate_enabled | initial 1 |
| 18:25 | sw_fog_closes_vent | initial 1 |
| 18:25 | sw_mister_closes_vent | initial 0 |
| 18:25 | sw_summer_vent_enabled | initial 1 |
| 18:25 | temp_hysteresis | initial 2.05 |
| 18:25 | vent_exchange_fraction | initial 0.3 |
| 18:25 | vent_prefer_dp_delta_f | initial 4 |
| 18:25 | vent_prefer_temp_delta_f | initial 5 |
| 18:25 | vpd_watch_dwell_s | initial 71.25 |
| 00:00 | cold_vent_guard_delta_f | 9 → 10 |
| 00:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.15 |
| 00:00 | dwell_gate_ms | 285000 → 330000 |
| 00:00 | fog_escalation_kpa | 0.2 → 0.4 |
| 00:00 | min_fog_off_s | 84 → 126 |
| 00:00 | min_fog_on_s | 54.75 → 39 |
| 00:00 | mister_all_delay_s | 97.5 → 111 |
| 00:00 | mister_engage_delay_s | 48.75 → 55.5 |
| 00:00 | mister_water_budget_gal | 140 → 110 |
| 00:00 | temp_hysteresis | 2.05 → 2.3200000000000003 |
| 00:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 00:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 00:00 | vpd_watch_dwell_s | 71.25 → 82.5 |
| 05:30 | dwell_gate_ms | 330000 → 345000 |
| 05:30 | fog_escalation_kpa | 0.4 → 0.45 |
| 05:30 | min_fog_off_s | 126 → 132 |
| 05:30 | min_fog_on_s | 39 → 36.75 |
| 05:30 | mister_all_delay_s | 111 → 115.5 |
| 05:30 | mister_engage_delay_s | 55.5 → 57.75 |
| 05:30 | mister_water_budget_gal | 110 → 100 |
| 05:30 | temp_hysteresis | 2.3200000000000003 → 2.41 |
| 05:30 | vpd_watch_dwell_s | 82.5 → 86.25 |
End-of-Day Summary
Climate
66.3–85.3°F; avg 73.5°F
0.62–1.80 kPa; avg 0.87 kPa
55.3–75.1%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 1.4h
- VPD stress (>2.0 kPa): 6.8h
- Cold stress (<55°F): 13.3h
Economics
Not available
USD 0.00
USD 0.140
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 4 min | Primary exhaust runtime. |
| Fan 2 | 8 min | Secondary exhaust runtime. |
| Vent | 12 min | Intake vent runtime. |
| Fog | 30 min | Fogger runtime. |
| Heat 1 electric | 102 min | Electric heater runtime. |
| Heat 2 gas | 0 min | Gas heater runtime. |
| Grow lights | 1568 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.04h | Center mister runtime. |
Water
- Total: 29 gal
- Mister: 21 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 74% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 78% | 6 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 75% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Foliage appears green and healthy. || Foliage looks green and healthy. No obvious signs of stress. || Potted tree in the west zone appears stable, but lighting is poor for a detailed health check. || Tree looks generally healthy, but some lower leaves might be slightly yellowing. || Tree looks generally healthy, though some leaves appear slightly pale. || Tree looks healthy, but soil moisture is unknown. || [yellowing] Lime tree shows some yellowing leaves, possibly indicating a nutrient deficiency or watering issue.
Hanging orchids appear generally healthy, though some aerial roots look dry. || Hanging orchids appear healthy with extensive root systems visible. || Hanging orchids appear stable, though roots look somewhat dry. || Hanging orchids are in bloom and appear very healthy with robust root systems. || Orchid is blooming and appears very healthy. || Orchids appear healthy with no visible signs of stress.
Seedlings appear healthy with no visible signs of stress. || Seedlings appear healthy, but light levels are very low. || Seedlings appear to be growing under intense artificial light. Hard to see detail due to glare.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 82.1°F | 1.19 kPa | 68.7% |
| 13:00 | 83.4°F | 1.12 kPa | 71.7% |
| 14:00 | 81.7°F | 1.13 kPa | 69.6% |
| 15:00 | 82.2°F | 1.15 kPa | 69.6% |
| 16:00 | 83.7°F | 1.22 kPa | 69.1% |
| 17:00 | 81.4°F | 1.07 kPa | 70.9% |
| 18:00 | 79.4°F | 1.14 kPa | 67.0% |
| 19:00 | 77.4°F | 1.17 kPa | 63.8% |
| 20:00 | 76.3°F | 1.04 kPa | 66.7% |
| 21:00 | 74.7°F | 0.92 kPa | 68.8% |
| 22:00 | 72.1°F | 0.80 kPa | 70.3% |
| 23:00 | 70.6°F | 0.75 kPa | 70.7% |
| 00:00 | 69.5°F | 0.70 kPa | 71.5% |
| 01:00 | 68.4°F | 0.67 kPa | 71.7% |
| 02:00 | 67.6°F | 0.65 kPa | 71.9% |
| 03:00 | 67.2°F | 0.65 kPa | 71.5% |
| 04:00 | 67.0°F | 0.65 kPa | 71.2% |
| 05:00 | 66.8°F | 0.65 kPa | 71.1% |
| 06:00 | 66.5°F | 0.66 kPa | 70.5% |
| 07:00 | 67.5°F | 0.72 kPa | 69.0% |
| 08:00 | 68.9°F | 0.79 kPa | 67.7% |
| 09:00 | 71.7°F | 0.98 kPa | 63.6% |
| 10:00 | 72.7°F | 1.01 kPa | 63.4% |
| 11:00 | 74.4°F | 1.12 kPa | 62.0% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-05 | 2.4h | 7.2h | 12.7h |
| 2026-10-06 | 2.7h | 7.7h | 12.1h |
| 2026-10-07 | 2.1h | 8.9h | 13.5h |
| 2026-10-08 | 2.1h | 7.5h | 12.6h |
| 2026-10-09 | 2.6h | 7.9h | 12.5h |
| 2026-10-10 | 1.9h | 8.9h | 12.4h |
| 2026-10-11 | 1.4h | 6.8h | 13.4h |