October 14, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:17 | MIDNIGHT | plan_written | Wrote public plan iris-20261014-0017. Resolved 00:18 MDT. |
| Morning planning cycle | 07:12 | SUNRISE | plan_written | Wrote public plan iris-20261014-0712. Resolved 07:13 MDT. |
| Solar peak planning checkpoint | 12:48 | SOLAR_MAX | acked | Acknowledged: No tunable change: solar is 140 W/m² versus a 0 W/m² raw forecast (bias-corrected remains 0), but the live VPD edge has recovered from 1.23 to 0.94 kPa, below the fresh dispatcher high edge, with 10.9°F dew margin, IDLE mode, and wet equipment off. Existing low-wet plan posture remains appropriate; open cumulative VPD alert is noted, not evidence of a current rising miss. Resolved 12:49 MDT. |
| Peak Stress | 14:48 | TRANSITION | acked | Acknowledged: Peak-stress checkpoint is tracking the existing posture: fresh climate is 77.0°F/1.13 kPa VPD with 13.0°F dew margin and IDLE; VPD is below the 1.17 kPa served high edge, vent/fans/fog/misters are off, and heat staging is active with both heaters. No narrow tunable change is justified. Resolved 14:48 MDT. |
| Forecast deviation | 16:06 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261014-1606. Resolved 16:08 MDT. |
| Decline | 17:23 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 17:23 MDT. |
| Evening planning cycle | 18:23 | SUNSET | plan_written | Wrote public plan iris-20261014-1824. Resolved 18:25 MDT. |
🌅 Morning Cycle (12:18 AM) — iris-20261014-0017
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261013-1452
Previous hypothesis: Cloud-cover deviation is forecast/weather error, not equipment failure: fresh climate is 80.2F, VPD 1.07 kPa, dew margin 10.7F, IDLE, with all climate relays off; six-hour telemetry rose smoothly and outdoor solar is 611 W/m2 despite the 100% cloud forecast. Historical calibration overstates outdoor VPD, so live dispatcher proof and the served high edge take precedence. Preserve a low-wet current bridge, suppress wetting through the 51-44F saturated passage, then allow only measured-VPD-gated readiness for the Thu/Fri clearing. The prior completed 1252 plan was scored 1 with a null anchor; its 0.040h window and missed/already-at-value rows support safety/persistence only, not causal efficacy. The superseded 1352 window is likewise short and will be evaluated after replacement. Vanda observations remain healthy… Result: Scoped 0.288h window: planner score 73.1; binary temp compliance 24.5%, VPD compliance 64.0%; cold stress 3.34h and VPD-high stress 1.59h, with no VPD-low or dew-risk hours. The low-wet objective partly held, but cold and VPD-high exposure persisted. Guardrail/missed-row evidence and short duration limit causal efficacy; resource, crop, DLI, fixed-panel, coverage, and physical-consumption endpoints unavailable. Score: 4/10
Hypothesis
Testing: Test a current-first low-wet bridge through a cold saturated dawn, then measured-VPD readiness after sunrise. Expected outcome: Hold dp-risk at 0h, keep cold stress below 15h, avoid VPD-low carryover and reduce heater/vent churn; resource and physical endpoints remain unavailable.
Setpoints
Wednesday October 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.22250000000000003 | Current low-wet bridge; suppress wetting and stabilize heat. |
| 04:30 | hyst 0.22250000000000003 | Pre-dawn cold/wet trough; preserve dew margin and avoid chur |
| 06:30 | hyst 0.21750000000000003 | Sunrise ramp remains overcast; allow only live VPD-gated rec |
| 10:30 | hyst 0.20750000000000002 | Early-day handoff; readiness only if measured VPD recovers. |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 2.055; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.006; all 1.1059999999999999; pulse 30; gap 60; wt 1.2666666666666666 | Current low-wet bridge; suppress wetting and stabilize heat. |
| 04:30 | s2 2.055; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.006; all 1.1059999999999999; pulse 30; gap 60; wt 1.2666666666666666 | Pre-dawn cold/wet trough; preserve dew margin and avoid chur |
| 06:30 | s2 2.04; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.956; all 1.056; pulse 30; gap 60; wt 1.3 | Sunrise ramp remains overcast; allow only live VPD-gated rec |
| 10:30 | s2 1.98; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.956; all 1.056; pulse 30; gap 60; wt 1.4666666666666666 | Early-day handoff; readiness only if measured VPD recovers. |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 10 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 00:15 | dwell_gate_ms | initial 315000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.45 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 132 |
| 00:15 | min_fog_on_s | initial 41.25 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 106.5 |
| 00:15 | mister_engage_delay_s | initial 53.25 |
| 00:15 | mister_water_budget_gal | initial 100 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.23 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 5 |
| 00:15 | vent_prefer_temp_delta_f | initial 6 |
| 00:15 | vpd_watch_dwell_s | initial 78.75 |
| 06:30 | cold_vent_guard_delta_f | 10 → 9 |
| 06:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.2 |
| 06:30 | dwell_gate_ms | 315000 → 300000 |
| 06:30 | min_fog_off_s | 132 → 126 |
| 06:30 | mister_all_delay_s | 106.5 → 102 |
| 06:30 | mister_engage_delay_s | 53.25 → 51 |
| 06:30 | temp_hysteresis | 2.23 → 2.14 |
| 06:30 | vent_prefer_dp_delta_f | 5 → 4 |
| 06:30 | vent_prefer_temp_delta_f | 6 → 5 |
| 06:30 | vpd_watch_dwell_s | 78.75 → 75 |
| 10:30 | dwell_gate_ms | 300000 → 270000 |
| 10:30 | fog_escalation_kpa | 0.45 → 0.35 |
| 10:30 | min_fog_off_s | 126 → 102 |
| 10:30 | min_fog_on_s | 41.25 → 48 |
| 10:30 | mister_all_delay_s | 102 → 93 |
| 10:30 | mister_engage_delay_s | 51 → 46.5 |
| 10:30 | temp_hysteresis | 2.14 → 1.96 |
| 10:30 | vpd_watch_dwell_s | 75 → 67.5 |
🌅 Morning Cycle (7:13 AM) — iris-20261014-0712
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261014-0017
Previous hypothesis: Cold saturated overcast start: the completed 2026-10-13 score was 75.2, with binary temp compliance 35.0% vs VPD 60.5%, cold stress 15.0h and VPD-high stress 9.1h; resource, crop, DLI, fixed-panel, and physical-consumption evidence are unavailable. Current house is 64.8F/0.61 kPa, RH 71%, dew margin 9.6F, IDLE with heat1 on, and an open too-wet band-drift alert. Forecast stays 43-50F, RH 91-97%, VPD 0.03-0.10, overcast through early day. Use a current-first low-wet bridge, steady thermal lead, and measured-VPD readiness only after dawn. The active 1825 plan is superseded only after this write; its missed/already-at-value rows will be graded as execution/safety evidence, not causal proof. Result: Scoped 0.371h window: planner score 73.2; binary temp compliance 34.3%, VPD compliance 58.4%; nominal cold stress 4.34h and VPD-high 2.75h, with no VPD-low or dew-risk hours. Guardrail audit had 40 missed versus 30 already-at-value rows, so this supports safety/persistence and execution-fidelity evidence, not causal efficacy. Cost, crop, DLI, fixed-panel coverage, firmware-consumption, and physical crop-outcome evidence unavailable. Score: 4/10
Hypothesis
Testing: Test a current-first low-wet, anti-churn posture through a cold saturated no-solar day, with measured-VPD readiness only. Expected outcome: Keep dew-risk and VPD-low stress at 0h, reduce heater-vent churn and keep cold stress below yesterday’s 15.15h; resource and physical endpoints remain unavailable.
Conditions
46.0°F
91.0%
0.0 W/m²
98.0%
Cold saturated overcast day; current house 63.1F/0.66kPa, IDLE with heat1, 11.2F dew margin. Yesterday score 75.2 had temp compliance 34.7% vs VPD 60.8%, with 15.15h cold and 9.1h VPD-high stress. The prior plan self-score 5 versus deterministic anchor 1; the 4-point gap reflects a 0.244h safety/persistence window with missed rows, not causal efficacy. Cost, crop, DLI, fixed-panel, coverage, and physical-consumption endpoints remain unavailable.
Expected stress windows
Use 60-minute thermal lead, conservative economizer and relay-churn penalty; avoid heater-vent cycling.
Keep mist/fog off, preserve 8F dew margin, and permit stable dehumidification only when measured.
Parameter rationale
Reduce heater-to-vent churn and keep cold stress below yesterday without changing crop bands.
Prevent wet overshoot and keep VPD-low stress and dew-risk at zero.
Hold heavy wet assist back unless live VPD materially re-enters the high edge.
Setpoints
Wednesday October 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:10 | hyst 0.21750000000000003 | Dawn: cold saturated, current IDLE; hold wetting and lead he |
| 09:30 | hyst 0.21250000000000002 | Ramp: no solar forecast; allow only measured-VPD edge respon |
| 12:30 | hyst 0.20750000000000002 | Peak: cold and wet risk dominate; keep fog gated and avoid u |
| 16:30 | hyst 0.22250000000000003 | Decline: taper wet assist before evening unless measured VPD |
| 19:00 | hyst 0.22750000000000004 | Evening: 44F saturated air; heat steadily, no mist/fog, avoi |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:10 | s2 2.04; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.154; all 1.254; pulse 30; gap 60; wt 1.1333333333333333 | Dawn: cold saturated, current IDLE; hold wetting and lead he |
| 09:30 | s2 2.025; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.054; all 1.204; pulse 30; gap 60; wt 1.2833333333333332 | Ramp: no solar forecast; allow only measured-VPD edge respon |
| 12:30 | s2 2.0100000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.054; all 1.204; pulse 30; gap 60; wt 1.3166666666666667 | Peak: cold and wet risk dominate; keep fog gated and avoid u |
| 16:30 | s2 2.055; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.104; all 1.254; pulse 30; gap 60; wt 1.1 | Decline: taper wet assist before evening unless measured VPD |
| 19:00 | s2 2.0700000000000003; cool_exit 2.3200000000000003; all_fans 0; dw_stress 0; engage 1.204; all 1.304; pulse 30; gap 60; wt 1.0666666666666667 | Evening: 44F saturated air; heat steadily, no mist/fog, avoi |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:10 | band_track_fraction | initial 0 |
| 07:10 | cold_vent_guard_delta_f | initial 11 |
| 07:10 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:10 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:10 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 07:10 | dwell_gate_ms | initial 300000 |
| 07:10 | enthalpy_close | initial 1 |
| 07:10 | enthalpy_open | initial -2 |
| 07:10 | fog_escalation_kpa | initial 0.5 |
| 07:10 | heat_hysteresis | initial 1 |
| 07:10 | min_fog_off_s | initial 126 |
| 07:10 | min_fog_on_s | initial 39 |
| 07:10 | mist_backoff_s | initial 600 |
| 07:10 | mist_max_closed_vent_s | initial 600 |
| 07:10 | mist_thermal_relief_s | initial 90 |
| 07:10 | mister_all_delay_s | initial 102 |
| 07:10 | mister_engage_delay_s | initial 51 |
| 07:10 | mister_water_budget_gal | initial 100 |
| 07:10 | night_vpd_bias_kpa | initial 0 |
| 07:10 | outdoor_staleness_max_s | initial 600 |
| 07:10 | sw_dwell_gate_enabled | initial 1 |
| 07:10 | sw_fog_closes_vent | initial 1 |
| 07:10 | sw_mister_closes_vent | initial 0 |
| 07:10 | sw_summer_vent_enabled | initial 1 |
| 07:10 | temp_hysteresis | initial 2.14 |
| 07:10 | vent_exchange_fraction | initial 0.3 |
| 07:10 | vent_prefer_dp_delta_f | initial 4 |
| 07:10 | vent_prefer_temp_delta_f | initial 7 |
| 07:10 | vpd_watch_dwell_s | initial 75 |
| 09:30 | cold_vent_guard_delta_f | 11 → 10 |
| 09:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.15 |
| 09:30 | dwell_gate_ms | 300000 → 285000 |
| 09:30 | fog_escalation_kpa | 0.5 → 0.45 |
| 09:30 | min_fog_off_s | 126 → 120 |
| 09:30 | min_fog_on_s | 39 → 41.25 |
| 09:30 | mister_all_delay_s | 102 → 97.5 |
| 09:30 | mister_engage_delay_s | 51 → 48.75 |
| 09:30 | temp_hysteresis | 2.14 → 2.05 |
| 09:30 | vent_prefer_temp_delta_f | 7 → 6 |
| 09:30 | vpd_watch_dwell_s | 75 → 71.25 |
| 12:30 | cold_vent_guard_delta_f | 10 → 9 |
| 12:30 | dwell_gate_ms | 285000 → 270000 |
| 12:30 | min_fog_off_s | 120 → 114 |
| 12:30 | min_fog_on_s | 41.25 → 43.5 |
| 12:30 | mister_all_delay_s | 97.5 → 93 |
| 12:30 | mister_engage_delay_s | 48.75 → 46.5 |
| 12:30 | temp_hysteresis | 2.05 → 1.96 |
| 12:30 | vent_prefer_dp_delta_f | 4 → 3 |
| 12:30 | vent_prefer_temp_delta_f | 6 → 5 |
| 12:30 | vpd_watch_dwell_s | 71.25 → 67.5 |
| 16:30 | cold_vent_guard_delta_f | 9 → 10 |
| 16:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.2 |
| 16:30 | dwell_gate_ms | 270000 → 315000 |
| 16:30 | fog_escalation_kpa | 0.45 → 0.5 |
| 16:30 | min_fog_off_s | 114 → 132 |
| 16:30 | min_fog_on_s | 43.5 → 36.75 |
| 16:30 | mister_all_delay_s | 93 → 106.5 |
| 16:30 | mister_engage_delay_s | 46.5 → 53.25 |
| 16:30 | temp_hysteresis | 1.96 → 2.23 |
| 16:30 | vent_prefer_dp_delta_f | 3 → 4 |
| 16:30 | vent_prefer_temp_delta_f | 5 → 6 |
| 16:30 | vpd_watch_dwell_s | 67.5 → 78.75 |
| 19:00 | cold_vent_guard_delta_f | 10 → 12 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.3 |
| 19:00 | dwell_gate_ms | 315000 → 330000 |
| 19:00 | min_fog_off_s | 132 → 138 |
| 19:00 | min_fog_on_s | 36.75 → 34.5 |
| 19:00 | mister_all_delay_s | 106.5 → 111 |
| 19:00 | mister_engage_delay_s | 53.25 → 55.5 |
| 19:00 | temp_hysteresis | 2.23 → 2.3200000000000003 |
| 19:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 19:00 | vent_prefer_temp_delta_f | 6 → 8 |
| 19:00 | vpd_watch_dwell_s | 78.75 → 82.5 |
🌆 Evening Cycle (4:08 PM) — iris-20261014-1606
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261014-0712
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:46.0,“outdoor_rh_min_pct”:91.0,“solar_peak_w_m2”:0.0,“cloud_cover_avg_pct”:98.0,“notes”:“Cold saturated overcast day; current house 63.1F/0.66kPa, IDLE with heat1, 11.2F dew margin. Yesterday score 75.2 had temp compliance 34.7% vs VPD 60.8%, with 15.15h cold and 9.1h VPD-high stress. The prior plan self-score 5 versus deterministic anchor 1; the 4-point gap reflects a 0.244h safety/persistence window with missed rows, not causal efficacy. Cost, crop, DLI, fixed-panel, coverage, and physical-consumption endpoints remain unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-14T07:10:00-06:00”,“end”:“2026-10-14T18:00:00-06:00”,“severity”:“high”,“mitigation”:“Use 60-minute thermal lead, conservative economizer and relay-churn penalty; avoid heater-vent cycling… Result: Scoped 0.095h window: planner score 61.6, temp compliance 22.7%, VPD compliance 54.1%, cold stress 1.29h-equivalent and VPD-high stress 0.61h-equivalent, no VPD-low or dew-risk hours. Forecast deviation was only a 0.04 in/h precipitation miss with no equipment fault; 29 missed and 17 already-at-value rows in the governing plan audit limit this to execution/persistence evidence, not causal efficacy. Resource cost, DLI, coverage, firmware consumption, and physical crop-outcome endpoints were unavailable. No durable lesson extracted. Score: 3/10
Hypothesis
Testing: Test low-wet recovery after a precipitation forecast miss, then measured-VPD gating into Thu/Fri/Sat dry ramps. Expected outcome: No VPD-low or dew-risk hours overnight; preserve current safe recovery, then reduce controller-attributable VPD-high exposure during Fri/Sat dry ramps without widening crop bands.
Setpoints
Wednesday October 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:05 | hyst 0.2175 | Recovered precip miss; retain current low-wet heat posture. |
| 22:00 | hyst 0.2175 | Cold saturated overnight; suppress wet assist and avoid chur |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:05 | s2 2.0100000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.337; all 1.387; pulse 30; gap 60; wt 1.2 | Recovered precip miss; retain current low-wet heat posture. |
| 22:00 | s2 2.0100000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.337; all 1.387; pulse 30; gap 60; wt 1.2 | Cold saturated overnight; suppress wet assist and avoid chur |
Thursday October 15
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.19749999999999998 | Measured Thu clearing; open modest VPD support only as neede |
| 18:00 | hyst 0.20749999999999996 | Thu evening RH rebound; taper wetting and protect dew margin |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.775; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.187; all 1.337; pulse 33.75; gap 52.5; wt 1.5 | Measured Thu clearing; open modest VPD support only as neede |
| 18:00 | s2 2.0100000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.287; all 1.387; pulse 30; gap 60; wt 1.2 | Thu evening RH rebound; taper wetting and protect dew margin |
Friday October 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.2175 | Frost dawn; steady heat lead and no unnecessary wetting. |
| 13:00 | hyst 0.1925 | Fri dry peak; band-couple moisture without chasing forecast |
| 19:00 | hyst 0.19749999999999998 | Keep a short recovery shoulder; unwind after observed VPD cl |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 2.04; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.287; all 1.387; pulse 30; gap 60; wt 1.1333333333333333 | Frost dawn; steady heat lead and no unnecessary wetting. |
| 13:00 | s2 1.5400000000000003; cool_exit 1.69; all_fans 1; dw_stress 0; engage 1.137; all 1.337; pulse 41.25; gap 37.5; wt 1.6999999999999997 | Fri dry peak; band-couple moisture without chasing forecast |
| 19:00 | s2 1.95; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.187; all 1.337; pulse 30; gap 52.5; wt 1.4666666666666666 | Keep a short recovery shoulder; unwind after observed VPD cl |
Saturday October 17
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 13:00 | hyst 0.1875 | Sat severe dry ramp; prioritize safe VPD recovery over resou |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 13:00 | s2 1.5100000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 1.137; all 1.337; pulse 48.75; gap 30; wt 1.8333333333333335 | Sat severe dry ramp; prioritize safe VPD recovery over resou |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:05 | band_track_fraction | initial 0 |
| 16:05 | cold_vent_guard_delta_f | initial 9 |
| 16:05 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:05 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:05 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 16:05 | dwell_gate_ms | initial 300000 |
| 16:05 | enthalpy_close | initial 1 |
| 16:05 | enthalpy_open | initial -2 |
| 16:05 | fog_escalation_kpa | initial 0.45 |
| 16:05 | heat_hysteresis | initial 1 |
| 16:05 | min_fog_off_s | initial 114 |
| 16:05 | min_fog_on_s | initial 43.5 |
| 16:05 | mist_backoff_s | initial 600 |
| 16:05 | mist_max_closed_vent_s | initial 600 |
| 16:05 | mist_thermal_relief_s | initial 90 |
| 16:05 | mister_all_delay_s | initial 102 |
| 16:05 | mister_engage_delay_s | initial 51 |
| 16:05 | mister_water_budget_gal | initial 100 |
| 16:05 | night_vpd_bias_kpa | initial 0 |
| 16:05 | outdoor_staleness_max_s | initial 600 |
| 16:05 | sw_dwell_gate_enabled | initial 1 |
| 16:05 | sw_fog_closes_vent | initial 1 |
| 16:05 | sw_mister_closes_vent | initial 0 |
| 16:05 | sw_summer_vent_enabled | initial 1 |
| 16:05 | temp_hysteresis | initial 2.14 |
| 16:05 | vent_exchange_fraction | initial 0.3 |
| 16:05 | vent_prefer_dp_delta_f | initial 5 |
| 16:05 | vent_prefer_temp_delta_f | initial 5 |
| 16:05 | vpd_watch_dwell_s | initial 75 |
| 12:00 | cold_vent_guard_delta_f | 9 → 8 |
| 12:00 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.1 |
| 12:00 | dwell_gate_ms | 300000 → 240000 |
| 12:00 | fog_escalation_kpa | 0.45 → 0.3 |
| 12:00 | min_fog_off_s | 114 → 90 |
| 12:00 | min_fog_on_s | 43.5 → 52.5 |
| 12:00 | mister_all_delay_s | 102 → 84 |
| 12:00 | mister_engage_delay_s | 51 → 42 |
| 12:00 | mister_water_budget_gal | 100 → 120 |
| 12:00 | temp_hysteresis | 2.14 → 1.78 |
| 12:00 | vent_prefer_dp_delta_f | 5 → 3 |
| 12:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 12:00 | vpd_watch_dwell_s | 75 → 60 |
| 18:00 | cold_vent_guard_delta_f | 8 → 9 |
| 18:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.2 |
| 18:00 | dwell_gate_ms | 240000 → 270000 |
| 18:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 18:00 | min_fog_off_s | 90 → 114 |
| 18:00 | min_fog_on_s | 52.5 → 43.5 |
| 18:00 | mister_all_delay_s | 84 → 93 |
| 18:00 | mister_engage_delay_s | 42 → 46.5 |
| 18:00 | mister_water_budget_gal | 120 → 100 |
| 18:00 | temp_hysteresis | 1.78 → 1.96 |
| 18:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 18:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 18:00 | vpd_watch_dwell_s | 60 → 67.5 |
| 06:00 | dwell_gate_ms | 270000 → 300000 |
| 06:00 | fog_escalation_kpa | 0.4 → 0.45 |
| 06:00 | min_fog_off_s | 114 → 126 |
| 06:00 | min_fog_on_s | 43.5 → 39 |
| 06:00 | mister_all_delay_s | 93 → 102 |
| 06:00 | mister_engage_delay_s | 46.5 → 51 |
| 06:00 | temp_hysteresis | 1.96 → 2.14 |
| 06:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 06:00 | vpd_watch_dwell_s | 67.5 → 75 |
| 13:00 | cold_vent_guard_delta_f | 9 → 8 |
| 13:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.05 |
| 13:00 | dwell_gate_ms | 300000 → 225000 |
| 13:00 | fog_escalation_kpa | 0.45 → 0.2 |
| 13:00 | min_fog_off_s | 126 → 66 |
| 13:00 | min_fog_on_s | 39 → 61.5 |
| 13:00 | mister_all_delay_s | 102 → 79.5 |
| 13:00 | mister_engage_delay_s | 51 → 39.75 |
| 13:00 | mister_water_budget_gal | 100 → 120 |
| 13:00 | temp_hysteresis | 2.14 → 1.69 |
| 13:00 | vent_prefer_dp_delta_f | 5 → 3 |
| 13:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 13:00 | vpd_watch_dwell_s | 75 → 56.25 |
| 19:00 | cold_vent_guard_delta_f | 8 → 9 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 19:00 | dwell_gate_ms | 225000 → 240000 |
| 19:00 | fog_escalation_kpa | 0.2 → 0.3 |
| 19:00 | min_fog_off_s | 66 → 90 |
| 19:00 | min_fog_on_s | 61.5 → 52.5 |
| 19:00 | mister_all_delay_s | 79.5 → 84 |
| 19:00 | mister_engage_delay_s | 39.75 → 42 |
| 19:00 | temp_hysteresis | 1.69 → 1.78 |
| 19:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 19:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 19:00 | vpd_watch_dwell_s | 56.25 → 60 |
| 13:00 | cold_vent_guard_delta_f | 9 → 8 |
| 13:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 13:00 | dwell_gate_ms | 240000 → 210000 |
| 13:00 | fog_escalation_kpa | 0.3 → 0.15 |
| 13:00 | min_fog_off_s | 90 → 54 |
| 13:00 | min_fog_on_s | 52.5 → 66 |
| 13:00 | mister_all_delay_s | 84 → 75 |
| 13:00 | mister_engage_delay_s | 42 → 37.5 |
| 13:00 | temp_hysteresis | 1.78 → 1.6 |
| 13:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 13:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 13:00 | vpd_watch_dwell_s | 60 → 52.5 |
🌆 Evening Cycle (6:25 PM) — iris-20261014-1824
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261014-0712
Result: Scoped 0.245h window: planner score 60.6; binary temp compliance 0.0%, VPD compliance 100.0%; cold stress 1.62h-equivalent, with no VPD-high, VPD-low, or dew-risk hours. The cold-saturated forecast posture prevented wet overshoot, but the very short window plus missed/already-at-value guardrail rows limits this to safety and execution-fidelity evidence, not causal climate efficacy. Resource cost, DLI, coverage, firmware-consumption, and physical crop endpoints unavailable; forecast conditions were materially warmer/drier than the typed hypothesis. Score: 5/10
Hypothesis
Testing: Overnight cold-saturated anti-churn test with a brief live-VPD recovery shoulder before wet-assist taper. Expected outcome: Keep dew-risk and VPD-low at 0, hold dew margin >=8F, and reduce cold stress and heater-vent cycling versus today’s 11.68h cold stress while accepting forecast-driven heating load.
Conditions
45.0°F
92.0%
0.0 W/m²
99.0%
Cold saturated overnight: 44-45F, RH 92-97%, no solar; house 73.3F/1.00kPa, dew margin 12.6F, IDLE with heat1. Today’s score 73.2 was below 7d 76.2; temp 34.3% vs VPD 58.4%, with 11.68h cold and 7.40h VPD-high. Prior plan self-score 4 vs anchor 1; missed/already-at-value rows make this safety/persistence evidence, not causal proof. Costs, DLI, crop outcomes, coverage and firmware consumption unavailable.
Expected stress windows
Keep a short measured-VPD recovery shoulder while dew margin stays >=8F, then taper before the saturated trough.
Use steady heat lead and anti-churn posture with conservative economizer to avoid heater-vent cycling.
Parameter rationale
Reduce heat-to-vent churn and keep cold stress below today's level without changing crop bands.
Allow a brief measured-VPD recovery shoulder, then prevent wet-assist carryover during the saturated trough.
Reduce repeated mist/dehum transitions and keep VPD-low and dew-risk hours at zero.
Setpoints
Wednesday October 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:20 | hyst 0.1875 | evening_settle: brief measured-VPD recovery; preserve dew ma |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:20 | s2 1.8900000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 37.5; wt 1.7 | evening_settle: brief measured-VPD recovery; preserve dew ma |
Thursday October 15
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | midnight_posture: saturated 44F air; suppress wetting and ho |
| 05:30 | hyst 0.1875 | pre_dawn: coldest shoulder; preserve heat and dew margin, wi |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | midnight_posture: saturated 44F air; suppress wetting and ho |
| 05:30 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.999; all 1.1989999999999998; pulse 33.75; gap 41.25; wt 1.7 | pre_dawn: coldest shoulder; preserve heat and dew margin, wi |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:20 | band_track_fraction | initial 0 |
| 18:20 | cold_vent_guard_delta_f | initial 10 |
| 18:20 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:20 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:20 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:20 | dwell_gate_ms | initial 210000 |
| 18:20 | enthalpy_close | initial 1 |
| 18:20 | enthalpy_open | initial -2 |
| 18:20 | fog_escalation_kpa | initial 0.25 |
| 18:20 | heat_hysteresis | initial 1 |
| 18:20 | min_fog_off_s | initial 66 |
| 18:20 | min_fog_on_s | initial 61.5 |
| 18:20 | mist_backoff_s | initial 600 |
| 18:20 | mist_max_closed_vent_s | initial 600 |
| 18:20 | mist_thermal_relief_s | initial 90 |
| 18:20 | mister_all_delay_s | initial 75 |
| 18:20 | mister_engage_delay_s | initial 37.5 |
| 18:20 | mister_water_budget_gal | initial 120 |
| 18:20 | night_vpd_bias_kpa | initial 0 |
| 18:20 | outdoor_staleness_max_s | initial 600 |
| 18:20 | sw_dwell_gate_enabled | initial 1 |
| 18:20 | sw_fog_closes_vent | initial 1 |
| 18:20 | sw_mister_closes_vent | initial 0 |
| 18:20 | sw_summer_vent_enabled | initial 1 |
| 18:20 | temp_hysteresis | initial 1.6 |
| 18:20 | vent_exchange_fraction | initial 0.3 |
| 18:20 | vent_prefer_dp_delta_f | initial 4 |
| 18:20 | vent_prefer_temp_delta_f | initial 6 |
| 18:20 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | cold_vent_guard_delta_f | 10 → 12 |
| 00:00 | min_fog_off_s | 66 → 72 |
| 00:00 | min_fog_on_s | 61.5 → 59.25 |
| 00:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 00:00 | vent_prefer_temp_delta_f | 6 → 8 |
End-of-Day Summary
Climate
60.7–78.7°F; avg 68.5°F
0.52–1.35 kPa; avg 0.83 kPa
52.0–75.2%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 7.8h
- Cold stress (<55°F): 16.8h
Economics
Not available
USD 3.33
USD 0.030
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 7 min | Fogger runtime. |
| Heat 1 electric | 1372 min | Electric heater runtime. |
| Heat 2 gas | 321 min | Gas heater runtime. |
| Grow lights | 1680 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 6 gal
- Mister: 6 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 71% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 80% | 6 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 78% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Foliage appears green and healthy, but partially obscured by lighting. || Foliage looks green and healthy. || Lime tree in pot on the floor looks generally healthy, but some lower leaves might be slightly yellowing. || Potted plants on the left appear to be in good condition, but details are hard to discern in the dark. || The lime tree is in the vegetative stage and looks generally healthy, though it's difficult to assess fully in the dark. || Tree appears healthy, no visible stress. || Tree looks generally healthy, but lighting is low in this area. || [yellowing] Lime tree shows some yellowing leaves, possibly nutrient deficiency or watering issue.
Hanging orchids appear healthy with extensive root systems visible. || Hanging orchids appear healthy, though some roots look dry. || Hanging orchids appear very healthy with robust root systems and active blooms. || Orchid is blooming and appears very healthy. || Orchids appear healthy, but hard to see detail from this distance.
Seedlings appear healthy and are growing well in the hydroponic system. || Seedlings appear healthy under grow lights. || Seedlings appear healthy, but hard to see detail. || Seedlings in hydroponic system appear healthy.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 76.6°F | 1.10 kPa | 64.9% |
| 13:00 | 78.7°F | 1.11 kPa | 67.2% |
| 14:00 | 79.4°F | 1.15 kPa | 66.8% |
| 15:00 | 81.8°F | 1.20 kPa | 68.1% |
| 16:00 | 80.7°F | 1.16 kPa | 67.7% |
| 17:00 | 77.0°F | 1.10 kPa | 65.4% |
| 18:00 | 74.9°F | 1.09 kPa | 63.2% |
| 19:00 | 73.3°F | 1.01 kPa | 64.2% |
| 20:00 | 71.5°F | 0.93 kPa | 65.0% |
| 21:00 | 69.5°F | 0.80 kPa | 68.1% |
| 22:00 | 67.3°F | 0.66 kPa | 71.2% |
| 23:00 | 65.8°F | 0.61 kPa | 71.6% |
| 00:00 | 64.5°F | 0.59 kPa | 71.4% |
| 01:00 | 63.4°F | 0.57 kPa | 71.5% |
| 02:00 | 62.7°F | 0.55 kPa | 71.7% |
| 03:00 | 62.2°F | 0.54 kPa | 71.7% |
| 04:00 | 61.6°F | 0.53 kPa | 71.5% |
| 05:00 | 61.0°F | 0.53 kPa | 71.1% |
| 06:00 | 63.2°F | 0.64 kPa | 67.9% |
| 07:00 | 63.9°F | 0.70 kPa | 65.8% |
| 08:00 | 66.4°F | 0.87 kPa | 61.1% |
| 09:00 | 68.6°F | 1.01 kPa | 57.9% |
| 10:00 | 70.9°F | 1.16 kPa | 55.2% |
| 11:00 | 72.7°F | 1.16 kPa | 57.9% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-08 | 2.1h | 7.5h | 12.6h |
| 2026-10-09 | 2.6h | 7.9h | 12.5h |
| 2026-10-10 | 1.9h | 8.9h | 12.4h |
| 2026-10-11 | 1.4h | 6.8h | 13.4h |
| 2026-10-12 | 1.5h | 10.1h | 14.4h |
| 2026-10-13 | 0.0h | 9.1h | 15.2h |
| 2026-10-14 | 0.0h | 7.8h | 16.8h |