8
4
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| Morning planning cycle (catch-up) | 07:50 | SUNRISE | delivery_failed | Delivery recorded without a public plan write. |
| Morning planning cycle (catch-up) | 07:51 | SUNRISE | plan_written | Wrote public plan iris-20261023-0751. Resolved 07:56 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 12:47 MDT. |
| Peak Stress | 14:47 | TRANSITION | acked | Acknowledged: No tactical change: live climate is fresh at 79.7°F, VPD 1.15 kPa at the latest dispatcher high edge (1.151), IDLE with all climate equipment off, and 12°F dew margin. No current heat or above-band miss; existing plan stages the next posture at 16:30. Resolved 14:47 MDT. |
| Forecast deviation | 15:21 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261023-1522. Resolved 15:24 MDT. |
| Decline | 17:09 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 17:11 MDT. |
| Forecast deviation | 17:51 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261023-1751. Resolved 17:54 MDT. |
| Evening planning cycle | 18:10 | SUNSET | plan_written | Wrote public plan iris-20261023-1810. Resolved 18:13 MDT. |
🌅 Morning Cycle (7:56 AM) — iris-20261023-0751
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261022-1307
Previous hypothesis: Forecast deviation: trigger VPD 1.77 vs observed 1.10 (Δ0.67) is a forecast/weather miss, not equipment failure or a confirmed regime shift. Fresh indoor climate is 77.7°F/1.01 kPa, inside dispatcher corridors (74.25–84.25°F; 0.672–1.222 kPa); east is 1.06, west 0.84, dew margin 10.9°F. State is IDLE with heat1 only; vent, fans, fog and misters are off. Six-hour house VPD rose to 1.25 then fell to 0.99. Historical outdoor forecast-minus-observed VPD bias is +0.051 kPa (0–6h)/+0.084 (6–24h), consistent in direction but much smaller than this trigger delta; do not conflate outdoor forecast calibration with indoor crop air… Result: Superseded iris-20261023-0751 after a partial 0.309-day window. Scoped diagnostics: planner_score 77.6, binary house compliance 5.4% (temp 27.5%, VPD 77.9%), nominal stress 4.40h (cold 3.37h, VPD-high 1.03h; no heat or VPD-low). The stated VPD-high <4h and VPD-low <1h diagnostic predictions were met, and dew-risk remained zero; however, 39 planned writes were missed and 24 already at value, so execution was incomplete. At replacement, fresh climate was 81.9°F/1.04 kPa in the dispatcher corridor, IDLE, 9.9°F dew margin, all equipment off. Treat this as partial safety/persistence evidence, not causal efficacy or measured crop benefit. Cost and qualified physical endpoints unavailable. Score: 4/10
Hypothesis
Testing: Test a live-edge-gated moisture bridge through today’s dry ramp: conservative dawn, band-coupled peak assistance, then taper only with measured recovery; no forecast-only wetting. Expected outcome: Maintain dew margin >=8F; no dawn forecast-only mist; keep VPD-low stress under 1h and nominal VPD-high stress under 4h, evaluated as historical controller diagnostics only (not physical crop or cost proof).
Conditions
80.0°F
12.0%
584.0 W/m²
43.0%
Dawn 66.6F/0.69 kPa; east 0.88 vs fresh high edge 0.929; dew margin 10.3F, heat1 on, wet off. Dry forecast peaks 80F/RH12%, but outdoor VPD bias is +0.13 kPa (forecast over observed), so gate wetting on indoor edge. Prior 0720 self 5/anchor 1 gap 4 reflects persistence, not efficacy; 1207’s 0.041d window returned null anchor. Active 1307 will be evaluated after replacement. Yesterday cost and qualified physical endpoints unavailable.
Expected stress windows
Use band-coupled wet assist only at measured high-edge stress; 0.05 engage excess, 0.25 all-zone, fog 0.20 when dew margin is safe.
Parameter rationale
Keep dawn dry and arm pulses near the live high edge, not on outdoor forecast alone; preserve dew margin at or above 8F.
Allow bounded fog only during measured VPD-high with safe dew margin; target under 4 nominal VPD-high stress hours without VPD-low overshoot.
Setpoints
Friday October 23
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:45 | hyst 0.2025 | Dawn: indoor VPD below edge; keep wet duty low while heat re |
| 10:30 | hyst 0.2025 | Ramp: arm moisture near the fresh high edge, not from foreca |
| 14:00 | hyst 0.1925 | Peak: compliance-first assist only for live VPD-high; retain |
| 16:30 | hyst 0.2025 | Decline: hold band-coupled recovery until indoor VPD clears |
| 19:00 | hyst 0.20750000000000002 | Evening: taper wet intensity; keep near-edge recovery bounde |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:45 | s2 1.8775000000000002; cool_exit 1.87; all_fans 0; dw_stress 0; engage 1.053; all 1.283; pulse 30; gap 56.25; wt 1.3533333333333333 | Dawn: indoor VPD below edge; keep wet duty low while heat re |
| 10:30 | s2 1.73; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9830000000000001; all 1.183; pulse 30; gap 41.25; wt 1.5533333333333332 | Ramp: arm moisture near the fresh high edge, not from foreca |
| 14:00 | s2 1.685; cool_exit 1.69; all_fans 0; dw_stress 1; engage 0.9830000000000001; all 1.183; pulse 37.5; gap 30; wt 1.7333333333333334 | Peak: compliance-first assist only for live VPD-high; retain |
| 16:30 | s2 1.7875; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9830000000000001; all 1.183; pulse 30; gap 33.75; wt 1.6333333333333333 | Decline: hold band-coupled recovery until indoor VPD clears |
| 19:00 | s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.0330000000000001; all 1.233; pulse 30; gap 56.25; wt 1.3533333333333333 | Evening: taper wet intensity; keep near-edge recovery bounde |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:45 | band_track_fraction | initial 0 |
| 07:45 | cold_vent_guard_delta_f | initial 8 |
| 07:45 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:45 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:45 | direct_wet_stress_vpd_margin_kpa | initial 0.12 |
| 07:45 | dwell_gate_ms | initial 255000 |
| 07:45 | enthalpy_close | initial 1 |
| 07:45 | enthalpy_open | initial -2 |
| 07:45 | fog_escalation_kpa | initial 0.3 |
| 07:45 | heat_hysteresis | initial 1 |
| 07:45 | min_fog_off_s | initial 96 |
| 07:45 | min_fog_on_s | initial 50.25 |
| 07:45 | mist_backoff_s | initial 600 |
| 07:45 | mist_max_closed_vent_s | initial 600 |
| 07:45 | mist_thermal_relief_s | initial 90 |
| 07:45 | mister_all_delay_s | initial 88.5 |
| 07:45 | mister_engage_delay_s | initial 44.25 |
| 07:45 | mister_water_budget_gal | initial 120 |
| 07:45 | night_vpd_bias_kpa | initial 0 |
| 07:45 | outdoor_staleness_max_s | initial 600 |
| 07:45 | sw_dwell_gate_enabled | initial 1 |
| 07:45 | sw_fog_closes_vent | initial 1 |
| 07:45 | sw_mister_closes_vent | initial 0 |
| 07:45 | sw_summer_vent_enabled | initial 1 |
| 07:45 | temp_hysteresis | initial 1.87 |
| 07:45 | vent_exchange_fraction | initial 0.3 |
| 07:45 | vent_prefer_dp_delta_f | initial 3 |
| 07:45 | vent_prefer_temp_delta_f | initial 4 |
| 07:45 | vpd_watch_dwell_s | initial 63.75 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.12 → 0.05 |
| 10:30 | fog_escalation_kpa | 0.3 → 0.25 |
| 10:30 | min_fog_off_s | 96 → 72 |
| 10:30 | min_fog_on_s | 50.25 → 59.25 |
| 14:00 | dwell_gate_ms | 255000 → 225000 |
| 14:00 | fog_escalation_kpa | 0.25 → 0.2 |
| 14:00 | min_fog_off_s | 72 → 54 |
| 14:00 | min_fog_on_s | 59.25 → 66 |
| 14:00 | mister_all_delay_s | 88.5 → 79.5 |
| 14:00 | mister_engage_delay_s | 44.25 → 39.75 |
| 14:00 | temp_hysteresis | 1.87 → 1.69 |
| 14:00 | vpd_watch_dwell_s | 63.75 → 56.25 |
| 16:30 | dwell_gate_ms | 225000 → 255000 |
| 16:30 | min_fog_off_s | 54 → 60 |
| 16:30 | min_fog_on_s | 66 → 63.75 |
| 16:30 | mister_all_delay_s | 79.5 → 88.5 |
| 16:30 | mister_engage_delay_s | 39.75 → 44.25 |
| 16:30 | temp_hysteresis | 1.69 → 1.87 |
| 16:30 | vpd_watch_dwell_s | 56.25 → 63.75 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 19:00 | dwell_gate_ms | 255000 → 270000 |
| 19:00 | fog_escalation_kpa | 0.2 → 0.35 |
| 19:00 | min_fog_off_s | 60 → 96 |
| 19:00 | min_fog_on_s | 63.75 → 50.25 |
| 19:00 | mister_all_delay_s | 88.5 → 93 |
| 19:00 | mister_engage_delay_s | 44.25 → 46.5 |
| 19:00 | temp_hysteresis | 1.87 → 1.96 |
| 19:00 | vpd_watch_dwell_s | 63.75 → 67.5 |
🌆 Evening Cycle (3:24 PM) — iris-20261023-1522
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261023-0751
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:80,“outdoor_rh_min_pct”:12,“solar_peak_w_m2”:584,“cloud_cover_avg_pct”:43,“notes”:“Dawn 66.6F/0.69 kPa; east 0.88 vs fresh high edge 0.929; dew margin 10.3F, heat1 on, wet off. Dry forecast peaks 80F/RH12%, but outdoor VPD bias is +0.13 kPa (forecast over observed), so gate wetting on indoor edge. Prior 0720 self 5/anchor 1 gap 4 reflects persistence, not efficacy; 1207’s 0.041d window returned null anchor. Active 1307 will be evaluated after replacement. Yesterday cost and qualified physical endpoints unavailable.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-10-23T11:30:00-06:00”,“end”:“2026-10-23T16:45:00-06:00”,“severity”:“medium”,“mitigation”:“Use band-coupled wet assist only at measured high-edge stress; 0.05 engage excess, 0.25 all-zone, fog 0.20 when dew margin is safe.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:0… Result: Window 2026-10-23 15:24–17:54 MDT (0.104 d): scoped planner_score 76.3, house-average binary compliance 9.2% (temp 35.0%, VPD 72.0%), nominal stress 1.52 h (cold 0.84 h, VPD-high 0.68 h; heat/VPD-low 0). The forecast wind trigger was a substantial miss (14.1 mph forecast/23.3 gust vs 1.92/3.0 observed). The plan’s cautious live-edge posture was plausible, but the short window and no qualified physical crop or resource evidence prevent causal attribution; its stated plan does not establish a numeric success goal. No durable lesson supported. Score: 4/10
Hypothesis
Testing: Test a live-edge-gated moisture bridge through today’s dry ramp: conservative dawn, band-coupled peak assistance, then taper only with measured recovery; no forecast-only wetting. Expected outcome: Maintain dew margin >=8F; no dawn forecast-only mist; keep VPD-low stress under 1h and nominal VPD-high stress under 4h, evaluated as historical controller diagnostics only (not physical crop or cost proof).
Setpoints
Friday October 23
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 15:15 | hyst 0.1975 | Wind miss has no live climate/equipment consequence; retain |
| 16:30 | hyst 0.1975 | Preserve the live-edge dry-ramp bridge; assist remains bound |
| 19:00 | hyst 0.20750000000000002 | Cool evening forecast; taper wet duty while retaining live-e |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 15:15 | s2 1.7000000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.169; all 1.369; pulse 30; gap 45; wt 1.5333333333333332 | Wind miss has no live climate/equipment consequence; retain |
| 16:30 | s2 1.685; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.169; all 1.369; pulse 33.75; gap 41.25; wt 1.6 | Preserve the live-edge dry-ramp bridge; assist remains bound |
| 19:00 | s2 1.7825; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.219; all 1.419; pulse 30; gap 52.5; wt 1.4 | Cool evening forecast; taper wet duty while retaining live-e |
Saturday October 24
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.20750000000000002 | Cold cloudy dawn; keep wetting conservative and preserve hea |
| 20:00 | hyst 0.20750000000000002 | Forecast cold, saturated night; suppress unnecessary wet ass |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.8499999999999999; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.319; all 1.4689999999999999; pulse 30; gap 60; wt 1.3 | Cold cloudy dawn; keep wetting conservative and preserve hea |
| 20:00 | s2 1.7575; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.369; all 1.4689999999999999; pulse 30; gap 60; wt 1.2866666666666666 | Forecast cold, saturated night; suppress unnecessary wet ass |
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 11:00 | hyst 0.1975 | Stage a modest Sunday bridge; wet assist still requires meas |
| 19:00 | hyst 0.20750000000000002 | Return to low-wet posture after the forecast Sunday peak; re |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 11:00 | s2 1.6100000000000003; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.169; all 1.369; pulse 30; gap 45; wt 1.5 | Stage a modest Sunday bridge; wet assist still requires meas |
| 19:00 | s2 1.91; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.319; all 1.4689999999999999; pulse 30; gap 60; wt 1.2866666666666666 | Return to low-wet posture after the forecast Sunday peak; re |
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 14:45 | hyst 0.20750000000000002 | Monday remains cool/cloudy; hold conservative wetting pendin |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 14:45 | s2 1.91; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.319; all 1.4689999999999999; pulse 30; gap 60; wt 1.3 | Monday remains cool/cloudy; hold conservative wetting pendin |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 15:15 | band_track_fraction | initial 0 |
| 15:15 | cold_vent_guard_delta_f | initial 8 |
| 15:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 15:15 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 15:15 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 15:15 | dwell_gate_ms | initial 240000 |
| 15:15 | enthalpy_close | initial 1 |
| 15:15 | enthalpy_open | initial -2 |
| 15:15 | fog_escalation_kpa | initial 0.35 |
| 15:15 | heat_hysteresis | initial 1 |
| 15:15 | min_fog_off_s | initial 78 |
| 15:15 | min_fog_on_s | initial 57 |
| 15:15 | mist_backoff_s | initial 600 |
| 15:15 | mist_max_closed_vent_s | initial 600 |
| 15:15 | mist_thermal_relief_s | initial 90 |
| 15:15 | mister_all_delay_s | initial 84 |
| 15:15 | mister_engage_delay_s | initial 42 |
| 15:15 | mister_water_budget_gal | initial 120 |
| 15:15 | night_vpd_bias_kpa | initial 0 |
| 15:15 | outdoor_staleness_max_s | initial 600 |
| 15:15 | sw_dwell_gate_enabled | initial 1 |
| 15:15 | sw_fog_closes_vent | initial 1 |
| 15:15 | sw_mister_closes_vent | initial 0 |
| 15:15 | sw_summer_vent_enabled | initial 1 |
| 15:15 | temp_hysteresis | initial 1.78 |
| 15:15 | vent_exchange_fraction | initial 0.3 |
| 15:15 | vent_prefer_dp_delta_f | initial 3 |
| 15:15 | vent_prefer_temp_delta_f | initial 4 |
| 15:15 | vpd_watch_dwell_s | initial 60 |
| 16:30 | fog_escalation_kpa | 0.35 → 0.2 |
| 16:30 | min_fog_off_s | 78 → 72 |
| 16:30 | min_fog_on_s | 57 → 59.25 |
| 19:00 | cold_vent_guard_delta_f | 8 → 9 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 19:00 | dwell_gate_ms | 240000 → 270000 |
| 19:00 | fog_escalation_kpa | 0.2 → 0.4 |
| 19:00 | min_fog_off_s | 72 → 90 |
| 19:00 | min_fog_on_s | 59.25 → 52.5 |
| 19:00 | mister_all_delay_s | 84 → 93 |
| 19:00 | mister_engage_delay_s | 42 → 46.5 |
| 19:00 | temp_hysteresis | 1.78 → 1.96 |
| 19:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 19:00 | vent_prefer_temp_delta_f | 4 → 5 |
| 19:00 | vpd_watch_dwell_s | 60 → 67.5 |
| 07:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.2 |
| 07:00 | fog_escalation_kpa | 0.4 → 0.45 |
| 07:00 | min_fog_off_s | 90 → 102 |
| 07:00 | min_fog_on_s | 52.5 → 48 |
| 20:00 | cold_vent_guard_delta_f | 9 → 10 |
| 20:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.25 |
| 20:00 | fog_escalation_kpa | 0.45 → 0.5 |
| 20:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 20:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 11:00 | cold_vent_guard_delta_f | 10 → 9 |
| 11:00 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 11:00 | dwell_gate_ms | 270000 → 240000 |
| 11:00 | fog_escalation_kpa | 0.5 → 0.25 |
| 11:00 | min_fog_off_s | 102 → 78 |
| 11:00 | min_fog_on_s | 48 → 57 |
| 11:00 | mister_all_delay_s | 93 → 84 |
| 11:00 | mister_engage_delay_s | 46.5 → 42 |
| 11:00 | temp_hysteresis | 1.96 → 1.78 |
| 11:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 11:00 | vent_prefer_temp_delta_f | 6 → 5 |
| 11:00 | vpd_watch_dwell_s | 67.5 → 60 |
| 19:00 | cold_vent_guard_delta_f | 9 → 10 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.2 |
| 19:00 | dwell_gate_ms | 240000 → 270000 |
| 19:00 | fog_escalation_kpa | 0.25 → 0.45 |
| 19:00 | min_fog_off_s | 78 → 102 |
| 19:00 | min_fog_on_s | 57 → 48 |
| 19:00 | mister_all_delay_s | 84 → 93 |
| 19:00 | mister_engage_delay_s | 42 → 46.5 |
| 19:00 | temp_hysteresis | 1.78 → 1.96 |
| 19:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 19:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 19:00 | vpd_watch_dwell_s | 60 → 67.5 |
🌆 Evening Cycle (5:54 PM) — iris-20261023-1751
validated
1/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261023-0751
Result: Window 2026-10-23 17:54–18:13 MDT (0.014 d, about 20 minutes): scoped planner_score 22.9, binary house compliance 2.8% (temp 10.5%, VPD 21.6%), nominal stress 0.06 h (cold 0.03 h, VPD-high 0.03 h; no heat/VPD-low). Cloud forecast had just caught up to observed overcast; no equipment fault was indicated. This window is too short for efficacy or forecast posture to be judged; utilities and qualified physical crop outcomes unavailable. No durable lesson supported. Score: 1/10
Hypothesis
Testing: Test a live-edge-gated moisture bridge through today’s dry ramp: conservative dawn, band-coupled peak assistance, then taper only with measured recovery; no forecast-only wetting. Expected outcome: Maintain dew margin >=8F; no dawn forecast-only mist; keep VPD-low stress under 1h and nominal VPD-high stress under 4h, evaluated as historical controller diagnostics only (not physical crop or cost proof).
Setpoints
Friday October 23
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 17:45 | hyst 0.1875 | Cloud nowcast caught up; bounded live-edge assist while meas |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 17:45 | s2 1.7375; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.016; all 1.216; pulse 33.75; gap 41.25; wt 1.7 | Cloud nowcast caught up; bounded live-edge assist while meas |
Saturday October 24
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.1875 | Cold overcast Saturday: retain band-coupled assist, with low |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.7575; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.016; all 1.216; pulse 33.75; gap 41.25; wt 1.7 | Cold overcast Saturday: retain band-coupled assist, with low |
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.1875 | Sunday daylight ramp: limited assist only if measured VPD cr |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.6475000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.016; all 1.216; pulse 33.75; gap 41.25; wt 1.7 | Sunday daylight ramp: limited assist only if measured VPD cr |
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1875 | Cold overcast Monday: retain edge gating, minimize unnecessa |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.016; all 1.216; pulse 33.75; gap 41.25; wt 1.7 | Cold overcast Monday: retain edge gating, minimize unnecessa |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 17:45 | band_track_fraction | initial 0 |
| 17:45 | cold_vent_guard_delta_f | initial 8 |
| 17:45 | cool_stage2_exit_hysteresis_f | initial 1 |
| 17:45 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 17:45 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 17:45 | dwell_gate_ms | initial 210000 |
| 17:45 | enthalpy_close | initial 1 |
| 17:45 | enthalpy_open | initial -2 |
| 17:45 | fog_escalation_kpa | initial 0.25 |
| 17:45 | heat_hysteresis | initial 1 |
| 17:45 | min_fog_off_s | initial 72 |
| 17:45 | min_fog_on_s | initial 59.25 |
| 17:45 | mist_backoff_s | initial 600 |
| 17:45 | mist_max_closed_vent_s | initial 600 |
| 17:45 | mist_thermal_relief_s | initial 90 |
| 17:45 | mister_all_delay_s | initial 75 |
| 17:45 | mister_engage_delay_s | initial 37.5 |
| 17:45 | mister_water_budget_gal | initial 120 |
| 17:45 | night_vpd_bias_kpa | initial 0 |
| 17:45 | outdoor_staleness_max_s | initial 600 |
| 17:45 | sw_dwell_gate_enabled | initial 1 |
| 17:45 | sw_fog_closes_vent | initial 1 |
| 17:45 | sw_mister_closes_vent | initial 0 |
| 17:45 | sw_summer_vent_enabled | initial 1 |
| 17:45 | temp_hysteresis | initial 1.6 |
| 17:45 | vent_exchange_fraction | initial 0.3 |
| 17:45 | vent_prefer_dp_delta_f | initial 3 |
| 17:45 | vent_prefer_temp_delta_f | initial 4 |
| 17:45 | vpd_watch_dwell_s | initial 52.5 |
🌆 Evening Cycle (6:13 PM) — iris-20261023-1810
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261023-0751
Result: Scoped 2026-10-23 18:13 to 2026-10-24 00:20 window (0.255 d): planner_score 69.9; contract-2 house-average binary temp compliance 0%, VPD 100%; nominal stress 1.65 h, all cold, with no heat/VPD-high/VPD-low; dew-risk 0h. The plan’s overnight live-edge VPD recovery posture was consistent with no VPD-high stress, but cold stress occurred as outdoor temperature fell below 45F. Full-day Oct 23 score was 76.3, temp 35%, VPD 72%, stress 21.67h (cold 14.67h, VPD-high 6.52h). Cost and utility totals unavailable; observed-minute coverage was zero eligible minutes and physical crop-band evidence unavailable. No causal efficacy claim or durable lesson supported. Score: 4/10
Hypothesis
Conditions
68.0°F
24.0%
0.0 W/m²
85.0%
At 18:10 indoor is 78.0F/1.03 kPa, east VPD 1.34, dew margin 11F. Forecast falls from 68F to 51F by 06:00, RH 24-37%, outdoor VPD 1.79 to 0.80, then becomes mostly overcast. Main challenge: close the measured evening VPD-high edge without carrying excess moisture into a cooler night; heating demand is secondary tonight, but today’s cold stress was high.
Expected stress windows
Keep band-relative mister access and modest duty while measured VPD is high; dew floor 8F; fog is time-gated after 17:00.
Conservative outdoor exchange and stable relay posture; no forecast-only wetting; retain dew-margin guard.
Parameter rationale
Hold a bounded recovery shoulder near the live high edge, then avoid VPD-low carryover; keep dew margin at least 8F.
Setpoints
Friday October 23
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:10 | hyst 0.1875 | Evening settle: measured VPD slightly high, east drier; dew |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:10 | s2 1.79; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.997; all 1.197; pulse 33.75; gap 30; wt 1.7000000000000002 | Evening settle: measured VPD slightly high, east drier; dew |
Saturday October 24
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | Midnight: retain near-edge moisture access at low duty; fore |
| 05:00 | hyst 0.1875 | Pre-dawn: 51F/0.80 outdoor VPD forecast; preserve heat and k |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.835; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.997; all 1.197; pulse 33.75; gap 41.25; wt 1.7 | Midnight: retain near-edge moisture access at low duty; fore |
| 05:00 | s2 1.835; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.997; all 1.197; pulse 33.75; gap 41.25; wt 1.7 | Pre-dawn: 51F/0.80 outdoor VPD forecast; preserve heat and k |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:10 | band_track_fraction | initial 0 |
| 18:10 | cold_vent_guard_delta_f | initial 9 |
| 18:10 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:10 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:10 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:10 | dwell_gate_ms | initial 210000 |
| 18:10 | enthalpy_close | initial 1 |
| 18:10 | enthalpy_open | initial -2 |
| 18:10 | fog_escalation_kpa | initial 0.2 |
| 18:10 | heat_hysteresis | initial 1 |
| 18:10 | min_fog_off_s | initial 54 |
| 18:10 | min_fog_on_s | initial 66 |
| 18:10 | mist_backoff_s | initial 600 |
| 18:10 | mist_max_closed_vent_s | initial 600 |
| 18:10 | mist_thermal_relief_s | initial 90 |
| 18:10 | mister_all_delay_s | initial 75 |
| 18:10 | mister_engage_delay_s | initial 37.5 |
| 18:10 | mister_water_budget_gal | initial 120 |
| 18:10 | night_vpd_bias_kpa | initial 0 |
| 18:10 | outdoor_staleness_max_s | initial 600 |
| 18:10 | sw_dwell_gate_enabled | initial 1 |
| 18:10 | sw_fog_closes_vent | initial 1 |
| 18:10 | sw_mister_closes_vent | initial 0 |
| 18:10 | sw_summer_vent_enabled | initial 1 |
| 18:10 | temp_hysteresis | initial 1.6 |
| 18:10 | vent_exchange_fraction | initial 0.3 |
| 18:10 | vent_prefer_dp_delta_f | initial 4 |
| 18:10 | vent_prefer_temp_delta_f | initial 5 |
| 18:10 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | fog_escalation_kpa | 0.2 → 0.25 |
| 00:00 | min_fog_off_s | 54 → 72 |
| 00:00 | min_fog_on_s | 66 → 59.25 |
End-of-Day Summary
Climate
63.6–85.2°F; avg 71.2°F
0.55–1.73 kPa; avg 0.82 kPa
55.1–74.4%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.5h
- VPD stress (>2.0 kPa): 6.5h
- Cold stress (<55°F): 14.7h
Economics
Not available
USD 0.11
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 16 min | Primary exhaust runtime. |
| Fan 2 | 18 min | Secondary exhaust runtime. |
| Vent | 34 min | Intake vent runtime. |
| Fog | 11 min | Fogger runtime. |
| Heat 1 electric | 440 min | Electric heater runtime. |
| Heat 2 gas | 10 min | Gas heater runtime. |
| Grow lights | 1006 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.04h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 74% | 5 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 67% | 3 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 40% | 2 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Large leafy plant visible in the upper right area (west zone) appears green and healthy, though some lower leaves show slight yellowing. || Large potted tree on the left. Foliage appears green and relatively healthy, though the soil moisture reading is missing. || Large potted tree visible in the upper left (west) corner. Foliage is dense and green, indicating good health despite the environmental readings. || The large leafy plant on the left (west) appears healthy with vibrant green foliage. No obvious signs of pest damage or nutrient deficiency are visible from this angle. || Vegetative growth is visible in the west zone (WEST-FLOOR). While the plant appears green, the surrounding area shows significant clutter and potential moisture issues on the floor.
Hanging baskets visible in the center background. Roots appear white and healthy, though the 0 lux reading suggests the image is likely from a low-light period or the sensor is not capturing the supplemental grow lights. || [some leaf yellowing, potential root exposure] Hanging baskets visible in the center. Roots appear exposed and dry, which is typical for Vanda, but some leaves show slight yellowing. The plants are generally upright. || [some leaf yellowing, potential root exposure] Hanging orchids visible in the center. Some leaves show yellowing, possibly due to nutrient deficiency or age. Roots are exposed and appear dry.
[wilting, drying] Seedlings in blue trays on the left rack appear dry and wilted, consistent with the 0.0% soil moisture reading. || [wilting, drying] Seedlings in the blue hydroponic trays (HYDRO-41) appear sparse and dried out, with visible browning of foliage, suggesting potential water stress or nutrient deficiency.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 77.1°F | 1.20 kPa | 62.4% |
| 13:00 | 78.6°F | 1.12 kPa | 66.7% |
| 14:00 | 80.3°F | 1.19 kPa | 66.5% |
| 15:00 | 80.5°F | 1.22 kPa | 65.8% |
| 16:00 | 78.9°F | 1.13 kPa | 66.7% |
| 17:00 | 76.8°F | 1.03 kPa | 67.6% |
| 18:00 | 75.0°F | 0.96 kPa | 67.8% |
| 19:00 | 73.4°F | 0.88 kPa | 69.1% |
| 20:00 | 72.0°F | 0.81 kPa | 70.0% |
| 21:00 | 71.0°F | 0.78 kPa | 70.2% |
| 22:00 | 68.8°F | 0.68 kPa | 72.0% |
| 23:00 | 67.4°F | 0.63 kPa | 72.7% |
| 00:00 | 66.3°F | 0.64 kPa | 70.8% |
| 01:00 | 65.4°F | 0.63 kPa | 70.4% |
| 02:00 | 64.5°F | 0.64 kPa | 69.4% |
| 03:00 | 63.9°F | 0.64 kPa | 68.4% |
| 04:00 | 63.8°F | 0.58 kPa | 71.5% |
| 05:00 | 63.8°F | 0.56 kPa | 72.4% |
| 06:00 | 64.5°F | 0.58 kPa | 72.3% |
| 07:00 | 66.1°F | 0.66 kPa | 70.3% |
| 08:00 | 67.0°F | 0.70 kPa | 69.3% |
| 09:00 | 69.7°F | 0.82 kPa | 67.3% |
| 10:00 | 70.8°F | 0.83 kPa | 67.7% |
| 11:00 | 74.3°F | 0.97 kPa | 66.7% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-17 | 0.4h | 7.8h | 15.6h |
| 2026-10-18 | 0.0h | 6.3h | 15.6h |
| 2026-10-19 | 0.0h | 6.2h | 15.6h |
| 2026-10-20 | 0.6h | 6.5h | 15.5h |
| 2026-10-21 | 0.0h | 8.4h | 14.7h |
| 2026-10-22 | 0.0h | 7.3h | 14.9h |
| 2026-10-23 | 0.5h | 6.5h | 14.7h |