October 25, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
9
5
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261025-0016. Resolved 00:19 MDT. |
| Morning planning cycle | 07:23 | SUNRISE | delivery_failed | Delivery recorded without a public plan write. |
| Morning planning cycle | 07:25 | SUNRISE | plan_written | Wrote public plan iris-20261025-0725. Resolved 07:30 MDT. |
| Forecast deviation | 10:33 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261025-1033. Resolved 10:37 MDT. |
| Forecast deviation | 11:33 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261025-1133. Resolved 11:36 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 12:47 MDT. |
| Peak Stress | 14:46 | TRANSITION | acked | Acknowledged: No tunable change: live climate is 76.4°F, VPD 1.08 kPa (below latest high edge ~1.164), dew margin 12.5°F, mode IDLE; heat1 is on with vent/fans/wet devices off. Existing peak-stress wet posture need not be intensified; first plan waypoint is 17:00 and forecast pressure is declining. Missing plan-coverage validation and static site context were noted; the feature-request text was rejected by Slack ops as unknown. Resolved 14:47 MDT. |
| Decline | 17:08 | TRANSITION | acked | Acknowledged: No tunable change: live VPD is 1.06 kPa, still above the current 0.99 kPa high edge, with healthy 12.7°F dew margin; east is 1.25 kPa. Climate is IDLE and wet devices are off as the evening cools. Keep wet assist available; defer the evening unwind until measured VPD stays below the high edge rather than relying on sunset/forecast alone. Resolved 17:09 MDT. |
| Evening planning cycle | 18:08 | SUNSET | plan_written | Wrote public plan iris-20261025-1808. Resolved 18:13 MDT. |
🌅 Morning Cycle (12:19 AM) — iris-20261025-0016
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261024-1809
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:50,“outdoor_rh_min_pct”:45,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:100,“notes”:“Cold overcast; low 41F, RH 80%, outdoor VPD 0.18. House 72.3F/0.91 kPa, dew margin 11.7F; east VPD 1.09. Oct 24 score 75.4 vs 7d 75.2; temp 37.7%, VPD 59.8%; nominal cold 10.58h, VPD-high 6.83h. Prior 0017 revised to 3 vs anchor 1; 0722 scored 3 vs anchor 1. Costs null; zero eligible observed-minute/crop evidence, so effects unproven.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-24T22:00:00-06:00”,“end”:“2026-10-25T07:00:00-06:00”,“severity”:“medium”,“mitigation”:“Keep outdoor exchange conservative as ambient reaches 41F; use stable heating posture and avoid heater-vent cycling… Result: Completed window through 2026-10-25 07:30 MDT: scoped planner_score 74.3; contract-2 house-average binary temp compliance 0.0%, VPD compliance 88.3%; nominal cold stress 2.99h and VPD-high stress 0.35h, with no heat or VPD-low stress. Dew-risk and resource terms unavailable in this window; coverage is unverified, and no physical crop outcome is eligible. The plan hypothesis was not present in the available completion summary, so this is a cautious partial grade, not causal attribution. Score: 5/10
Hypothesis
Testing: No controlled experiment; current-measurement-gated moisture posture for a cold, humid dawn and modest solar rise. Expected outcome: Target 0 dew-risk hours and no VPD-low overshoot; preserve measured-edge VPD-high assist if needed. Cold stress may persist under 39–41°F outdoor lows; no causal crop or resource claim.
Setpoints
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.20750000000000002 | Current VPD is below the high edge; keep cold-night exchange |
| 04:30 | hyst 0.20750000000000002 | 40–41°F ambient; retain heater-focused posture and avoid for |
| 07:00 | hyst 0.20750000000000002 | Overcast dawn; allow natural warm-up with dew protection and |
| 10:00 | hyst 0.20750000000000002 | Solar/VPD rise is modest; permit moderate wet assist only on |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.806; all 1.006; pulse 30; gap 48.75; wt 1.4333333333333333 | Current VPD is below the high edge; keep cold-night exchange |
| 04:30 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.806; all 1.006; pulse 30; gap 48.75; wt 1.4333333333333333 | 40–41°F ambient; retain heater-focused posture and avoid for |
| 07:00 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.806; all 1.006; pulse 30; gap 48.75; wt 1.4666666666666668 | Overcast dawn; allow natural warm-up with dew protection and |
| 10:00 | s2 1.92; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.806; all 1.006; pulse 33.75; gap 45; wt 1.5666666666666667 | Solar/VPD rise is modest; permit moderate wet assist only on |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 8 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 270000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.35 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 84 |
| 00:16 | min_fog_on_s | initial 54.75 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 93 |
| 00:16 | mister_engage_delay_s | initial 46.5 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 1.96 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 3 |
| 00:16 | vent_prefer_temp_delta_f | initial 4 |
| 00:16 | vpd_watch_dwell_s | initial 67.5 |
| 07:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 10:00 | min_fog_off_s | 84 → 78 |
| 10:00 | min_fog_on_s | 54.75 → 57 |
🌅 Morning Cycle (7:30 AM) — iris-20261025-0725
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-0016
Previous hypothesis: Oct 24 planner score was 77.5 with 30.1% legacy house-average temp compliance, 66.7% VPD compliance, and 23.2 nominal stress hours (15.72 cold, 7.48 VPD-high); dew-risk was 0h and minimum dew margin 8.6°F. Resource terms and physical crop evidence were unavailable; coverage is unverified. Completed plans 0017 and 0722 are already evaluated at 3/10 vs anchor 1; 1809 remains active until its future 04:30 waypoint, so it is not evaluated. No new durable lesson is supported. Overnight outdoor lows are 39–41°F; current house VPD is below its high edge with 11°F dew margin. Keep overnight moisture measurement-gated, then allow modest band-coupled assist during the forecast daytime rise. Plan-coverage validation and static site context are unavailable; traceability brief is unavailable. Result: Completed window evidence: 1.40h cold stress, 0.27h VPD-high, no VPD-low; temperature binary compliance 1.2%. The forecasted cold load occurred and VPD-low stayed absent; VPD-high was below the <2h target. No qualified cost, dew-risk, fixed-panel, or physical crop evidence; treatment attribution remains uncertain. Score: 4/10
Hypothesis
Testing: Observational test: gate wet assist to live VPD-edge demand through a cold, modestly sunny day; compare VPD-high/low and dew-risk without claiming causal crop benefit. Expected outcome: For Oct 25: keep VPD-high stress below 2h, VPD-low below 1h, and dew-risk at 0h; retain wet assist only for measured near-edge demand. Cold stress may persist under the 37F dawn.
Conditions
57.0°F
50.0%
523.0 W/m²
63.667%
Cold dawn, low 37F and forecast high 57F; outdoor VPD peaks at 0.79 kPa (not an indoor estimate). Clouds are sparse through 15:00, then 100% from 16:00. Current house is 63F/0.74 kPa with 12.9F dew margin.
Expected stress windows
Maintain stable heating and avoid cold-air exchange; keep wet assist gated to measured indoor VPD.
Parameter rationale
Preserve near-edge measured wet assist without forecast-only mist; target <2h VPD-high, <1h VPD-low and 0 dew-risk hours.
Setpoints
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:25 | hyst 0.20750000000000002 | Cold dawn; preserve stable heat, avoid cold-air exchange, an |
| 09:30 | hyst 0.20750000000000002 | Modest morning ramp; keep wetting tied to live VPD, not outd |
| 14:00 | hyst 0.20750000000000002 | Midday outdoor VPD remains modest; allow bounded assist only |
| 16:00 | hyst 0.20750000000000002 | Cloud deck arrives; taper wet duty while protecting heat and |
| 18:30 | hyst 0.20750000000000002 | Cold humid evening; no forecast-only wetting, but retain liv |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:25 | s2 1.92; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 45; wt 1.5 | Cold dawn; preserve stable heat, avoid cold-air exchange, an |
| 09:30 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 48.75; wt 1.4866666666666666 | Modest morning ramp; keep wetting tied to live VPD, not outd |
| 14:00 | s2 1.95; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 52.5; wt 1.4666666666666666 | Midday outdoor VPD remains modest; allow bounded assist only |
| 16:00 | s2 1.98; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 60; wt 1.3466666666666667 | Cloud deck arrives; taper wet duty while protecting heat and |
| 18:30 | s2 1.995; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 60; wt 1.2666666666666666 | Cold humid evening; no forecast-only wetting, but retain liv |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:25 | band_track_fraction | initial 0 |
| 07:25 | cold_vent_guard_delta_f | initial 8 |
| 07:25 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:25 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:25 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 07:25 | dwell_gate_ms | initial 270000 |
| 07:25 | enthalpy_close | initial 1 |
| 07:25 | enthalpy_open | initial -2 |
| 07:25 | fog_escalation_kpa | initial 0.35 |
| 07:25 | heat_hysteresis | initial 1 |
| 07:25 | min_fog_off_s | initial 78 |
| 07:25 | min_fog_on_s | initial 57 |
| 07:25 | mist_backoff_s | initial 600 |
| 07:25 | mist_max_closed_vent_s | initial 600 |
| 07:25 | mist_thermal_relief_s | initial 90 |
| 07:25 | mister_all_delay_s | initial 93 |
| 07:25 | mister_engage_delay_s | initial 46.5 |
| 07:25 | mister_water_budget_gal | initial 120 |
| 07:25 | night_vpd_bias_kpa | initial 0 |
| 07:25 | outdoor_staleness_max_s | initial 600 |
| 07:25 | sw_dwell_gate_enabled | initial 1 |
| 07:25 | sw_fog_closes_vent | initial 1 |
| 07:25 | sw_mister_closes_vent | initial 0 |
| 07:25 | sw_summer_vent_enabled | initial 1 |
| 07:25 | temp_hysteresis | initial 1.96 |
| 07:25 | vent_exchange_fraction | initial 0.3 |
| 07:25 | vent_prefer_dp_delta_f | initial 3 |
| 07:25 | vent_prefer_temp_delta_f | initial 4 |
| 07:25 | vpd_watch_dwell_s | initial 67.5 |
| 09:30 | min_fog_off_s | 78 → 84 |
| 09:30 | min_fog_on_s | 57 → 54.75 |
| 14:00 | min_fog_off_s | 84 → 90 |
| 14:00 | min_fog_on_s | 54.75 → 52.5 |
| 16:00 | fog_escalation_kpa | 0.35 → 0.4 |
| 16:00 | min_fog_off_s | 90 → 102 |
| 16:00 | min_fog_on_s | 52.5 → 48 |
| 18:30 | min_fog_off_s | 102 → 108 |
| 18:30 | min_fog_on_s | 48 → 45.75 |
☀️ Midday Cycle (10:37 AM) — iris-20261025-1033
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-0016
Result: Short 10:37–11:36 window. Available context documents the forecast cloud miss and a modest thermal/forecast correction, but no qualified scoped outcome or attributable treatment effect for this window; resource and physical crop evidence unavailable. Grade conservatively; do not claim improved compliance from the daily scorecard. Score: 3/10
Hypothesis
Testing: Continue the existing observational test: wet assist only on live VPD-edge demand through a cold, partly sunny day; no causal crop-benefit claim. Expected outcome: Keep wet assist measurement-gated through 19:00, avoid forecast-only misting, and maintain dew margin above 5°F; cold stress may persist. Assess only qualified scorecard data, not crop benefit or energy savings.
Setpoints
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:33 | hyst 0.1975 | Clear solar miss; cold low-edge house, retain trial and live |
| 14:00 | hyst 0.1975 | Daylight warming is forecast modest; do not pre-cool or wet |
| 18:30 | hyst 0.1975 | Sunset cooling and humid outdoor air; retain measured-edge g |
| 22:00 | hyst 0.1975 | Cold, humid night forecast; no scheduled wetting, preserve s |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:33 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Clear solar miss; cold low-edge house, retain trial and live |
| 14:00 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Daylight warming is forecast modest; do not pre-cool or wet |
| 18:30 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Sunset cooling and humid outdoor air; retain measured-edge g |
| 22:00 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Cold, humid night forecast; no scheduled wetting, preserve s |
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.1975 | Keep heat stability first before any solar recovery; preserv |
| 12:00 | hyst 0.1975 | Cloudy-to-partly-sunny cold day; keep moisture response tied |
| 16:00 | hyst 0.1975 | Finish next-day horizon with the same observational treatmen |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Keep heat stability first before any solar recovery; preserv |
| 12:00 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Cloudy-to-partly-sunny cold day; keep moisture response tied |
| 16:00 | s2 1.9; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1480000000000001; all 1.348; pulse 33.75; gap 45; wt 1.5666666666666667 | Finish next-day horizon with the same observational treatmen |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 10:33 | band_track_fraction | initial 0 |
| 10:33 | cold_vent_guard_delta_f | initial 10 |
| 10:33 | cool_stage2_exit_hysteresis_f | initial 1 |
| 10:33 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 10:33 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 10:33 | dwell_gate_ms | initial 240000 |
| 10:33 | enthalpy_close | initial 1 |
| 10:33 | enthalpy_open | initial -2 |
| 10:33 | fog_escalation_kpa | initial 0.4 |
| 10:33 | heat_hysteresis | initial 1 |
| 10:33 | min_fog_off_s | initial 78 |
| 10:33 | min_fog_on_s | initial 57 |
| 10:33 | mist_backoff_s | initial 600 |
| 10:33 | mist_max_closed_vent_s | initial 600 |
| 10:33 | mist_thermal_relief_s | initial 90 |
| 10:33 | mister_all_delay_s | initial 84 |
| 10:33 | mister_engage_delay_s | initial 42 |
| 10:33 | mister_water_budget_gal | initial 120 |
| 10:33 | night_vpd_bias_kpa | initial 0 |
| 10:33 | outdoor_staleness_max_s | initial 600 |
| 10:33 | sw_dwell_gate_enabled | initial 1 |
| 10:33 | sw_fog_closes_vent | initial 1 |
| 10:33 | sw_mister_closes_vent | initial 0 |
| 10:33 | sw_summer_vent_enabled | initial 1 |
| 10:33 | temp_hysteresis | initial 1.78 |
| 10:33 | vent_exchange_fraction | initial 0.3 |
| 10:33 | vent_prefer_dp_delta_f | initial 5 |
| 10:33 | vent_prefer_temp_delta_f | initial 6 |
| 10:33 | vpd_watch_dwell_s | initial 60 |
☀️ Midday Cycle (11:36 AM) — iris-20261025-1133
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-0016
Result: Scoped window 2026-10-25 11:36–18:13 (per assembled WINDOW SCORECARD): planner score 74.2; contract-2 legacy house-average binary both-axis compliance 1.2%, temp 27.7%, VPD 59.7%; nominal stress 6.64h total (cold 4.32h, VPD-high 2.32h, heat and VPD-low 0h); dew-risk 0h. The cloud forecast was badly wrong earlier (clear break vs forecast overcast), and the plan preserved live, measurement-gated wet assist rather than forecast-only wetting. The window still had weak temp/VPD compliance and substantial cold/VPD-high stress. Cost/resource terms are unavailable; coverage unverified; no physical crop or fixed-panel evidence. Daily Oct 25 score 76.8 is context, not causal attribution. No durable causal lesson supported. Score: 4/10
Hypothesis
Testing: Continue the existing observational test: wet assist only on live VPD-edge demand through a cold, partly sunny day; no causal crop-benefit claim. Expected outcome: Keep wet assist measurement-gated and dew margin above 5°F; avoid forecast-only misting and band changes. Evaluate only qualified scorecard evidence; resources and physical crop outcomes remain unavailable.
Setpoints
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 11:33 | hyst 0.19749999999999998 | Maintain live-edge assist: measured VPD is above the latest |
| 17:00 | hyst 0.19749999999999998 | Keep moisture edge-triggered through recovery; firmware fog |
| 22:00 | hyst 0.19749999999999998 | Cold, humid forecast is not indoor evidence; retain measured |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 11:33 | s2 1.7725000000000002; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.226; all 1.426; pulse 33.75; gap 30; wt 1.7000000000000002 | Maintain live-edge assist: measured VPD is above the latest |
| 17:00 | s2 1.7725000000000002; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.226; all 1.426; pulse 33.75; gap 30; wt 1.7000000000000002 | Keep moisture edge-triggered through recovery; firmware fog |
| 22:00 | s2 1.86; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.226; all 1.426; pulse 33.75; gap 30; wt 1.7000000000000002 | Cold, humid forecast is not indoor evidence; retain measured |
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.19749999999999998 | Reassess via live VPD as clouds break; outdoor VPD bias is n |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.7725000000000002; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.226; all 1.426; pulse 33.75; gap 30; wt 1.7000000000000002 | Reassess via live VPD as clouds break; outdoor VPD bias is n |
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.19749999999999998 | Anticipate the forecast dry ramp only with observed band-edg |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.7725000000000002; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.226; all 1.426; pulse 33.75; gap 30; wt 1.7000000000000002 | Anticipate the forecast dry ramp only with observed band-edg |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 11:33 | band_track_fraction | initial 0 |
| 11:33 | cold_vent_guard_delta_f | initial 8 |
| 11:33 | cool_stage2_exit_hysteresis_f | initial 1 |
| 11:33 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 11:33 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 11:33 | dwell_gate_ms | initial 240000 |
| 11:33 | enthalpy_close | initial 1 |
| 11:33 | enthalpy_open | initial -2 |
| 11:33 | fog_escalation_kpa | initial 0.25 |
| 11:33 | heat_hysteresis | initial 1 |
| 11:33 | min_fog_off_s | initial 54 |
| 11:33 | min_fog_on_s | initial 66 |
| 11:33 | mist_backoff_s | initial 600 |
| 11:33 | mist_max_closed_vent_s | initial 600 |
| 11:33 | mist_thermal_relief_s | initial 90 |
| 11:33 | mister_all_delay_s | initial 84 |
| 11:33 | mister_engage_delay_s | initial 42 |
| 11:33 | mister_water_budget_gal | initial 120 |
| 11:33 | night_vpd_bias_kpa | initial 0 |
| 11:33 | outdoor_staleness_max_s | initial 600 |
| 11:33 | sw_dwell_gate_enabled | initial 1 |
| 11:33 | sw_fog_closes_vent | initial 1 |
| 11:33 | sw_mister_closes_vent | initial 0 |
| 11:33 | sw_summer_vent_enabled | initial 1 |
| 11:33 | temp_hysteresis | initial 1.78 |
| 11:33 | vent_exchange_fraction | initial 0.3 |
| 11:33 | vent_prefer_dp_delta_f | initial 3 |
| 11:33 | vent_prefer_temp_delta_f | initial 4 |
| 11:33 | vpd_watch_dwell_s | initial 60 |
🌆 Evening Cycle (6:13 PM) — iris-20261025-1808
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-1133
Previous hypothesis: Observed cloud cover was 0% versus a 100% forecast, while the fresh hourly forecast now trends to 11% at 13:00 and 7% at 14:00; cloud calibration is unavailable, so treat this as a near-term forecast miss/nowcast catch-up, not a proven persistent regime shift. Current indoor VPD is 1.26 kPa above the latest dispatcher high edge of 1.172, with 16.2°F dew margin; climate is SEALED_MIST_FOG and fog is on while vent/fans are off, so this is not an equipment failure. Preserve the existing live-edge, measurement-gated wet-assist observation and avoid forecast-only wetting or target-band changes. The completed 07:25 window had 1.40h cold, 0.27h VPD-high, no VPD-low; predicted cold and low VPD-low/VPD-high stress were broadly met, but temp compliance was 1.2% and resource/physical crop evidence is unavailable… Result: Scoped 2026-10-25 18:13–2026-10-26 00:19 window: contract-2 house-average temp compliance 0%, VPD compliance 100%; nominal cold stress 1.70h, with no heat/VPD-high/VPD-low stress. Whole-day Oct 25 had 0 dp-risk hours and 9.1°F minimum dew margin, but those are not window-specific. Cost/resource and fixed-panel crop evidence unavailable; coverage unverified. Cold outdoor load was forecast; the window maintained VPD without recorded low-VPD stress, but temperature stayed outside the historical band. No causal claim or durable lesson. Score: 5/10
Hypothesis
Testing: Observational overnight: keep wet assist available at the live VPD edge; no forecast-only wetting or causal crop-benefit claim. Expected outcome: Keep dew margin above 5°F with 0 dp-risk hours; avoid VPD-low overshoot while retaining live VPD-edge assist. Cost and physical crop outcomes remain unqualified.
Conditions
51.0°F
64.0%
0.0 W/m²
94.583%
Fresh 19:00–06:00 forecast: 51°F peak falling to 45°F; RH 64–96%, outdoor VPD 0.04–0.46, cloud average 94.583%. Indoors 72.1°F, VPD 0.96, dew margin 12.5°F. Oct 25 score 74.6; cold and VPD-high stress dominated; costs and physical crop outcomes unavailable. Prior 0725 self-score 4 vs anchor 1 (+3): limited short-window VPD success, but weak temperature compliance and missing physical/resource evidence; grade remains uncertain, not causal.
Expected stress windows
Keep exchange conservative as outdoor falls to 45°F; retain normal firmware heat staging and avoid band changes.
Avoid forecast-only wetting in saturated air; preserve dew margin while retaining live band-edge assist.
Parameter rationale
Keep mister demand band-coupled at high+0.05; avoid needless wetting while retaining live-edge assist, with dew margin above 5°F and VPD-low under 2h.
Setpoints
Sunday October 25
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:08 | hyst 0.1875 | evening_settle: cold/wet air approaches; retain measured edg |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:08 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 41.25; wt 1.7 | evening_settle: cold/wet air approaches; retain measured edg |
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | midnight_posture: 46–48°F, RH rising; protect heat and dew m |
| 05:00 | hyst 0.1875 | pre_dawn: forecast 45°F/96% RH, VPD 0.04; keep wet duty boun |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 41.25; wt 1.7 | midnight_posture: 46–48°F, RH rising; protect heat and dew m |
| 05:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 41.25; wt 1.7 | pre_dawn: forecast 45°F/96% RH, VPD 0.04; keep wet duty boun |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:08 | band_track_fraction | initial 0 |
| 18:08 | cold_vent_guard_delta_f | initial 12 |
| 18:08 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:08 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:08 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 18:08 | dwell_gate_ms | initial 210000 |
| 18:08 | enthalpy_close | initial 1 |
| 18:08 | enthalpy_open | initial -2 |
| 18:08 | fog_escalation_kpa | initial 0.25 |
| 18:08 | heat_hysteresis | initial 1 |
| 18:08 | min_fog_off_s | initial 72 |
| 18:08 | min_fog_on_s | initial 59.25 |
| 18:08 | mist_backoff_s | initial 600 |
| 18:08 | mist_max_closed_vent_s | initial 600 |
| 18:08 | mist_thermal_relief_s | initial 90 |
| 18:08 | mister_all_delay_s | initial 75 |
| 18:08 | mister_engage_delay_s | initial 37.5 |
| 18:08 | mister_water_budget_gal | initial 120 |
| 18:08 | night_vpd_bias_kpa | initial 0 |
| 18:08 | outdoor_staleness_max_s | initial 600 |
| 18:08 | sw_dwell_gate_enabled | initial 1 |
| 18:08 | sw_fog_closes_vent | initial 1 |
| 18:08 | sw_mister_closes_vent | initial 0 |
| 18:08 | sw_summer_vent_enabled | initial 1 |
| 18:08 | temp_hysteresis | initial 1.6 |
| 18:08 | vent_exchange_fraction | initial 0.3 |
| 18:08 | vent_prefer_dp_delta_f | initial 5 |
| 18:08 | vent_prefer_temp_delta_f | initial 8 |
| 18:08 | vpd_watch_dwell_s | initial 52.5 |
End-of-Day Summary
Climate
59.2–79.7°F; avg 68.2°F
0.53–1.36 kPa; avg 0.88 kPa
54.7–73.7%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 8.7h
- Cold stress (<55°F): 16.2h
Economics
Not available
USD 4.20
USD 0.020
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 5 min | Fogger runtime. |
| Heat 1 electric | 1340 min | Electric heater runtime. |
| Heat 2 gas | 404 min | Gas heater runtime. |
| Grow lights | 1083 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 5 gal
- Mister: 5 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 74% | 9 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 70% | 5 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 58% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Large epiphytic plant (likely orchid) in the center. Roots are exposed and appear healthy (white/green), though some lower roots are brown. Leaves are green and upright. || Large leafy plant visible in the upper left corner. Foliage appears dense and green, indicating good health. || Large leafy plant visible on the left. Foliage appears dense and turgid, suggesting adequate hydration despite the low temperature. || Large potted tree visible in the background right. Foliage appears green and dense, indicating good health. No obvious signs of pest damage or yellowing. || Large potted tree visible in the upper left (west zone). Foliage is dense, dark green, and appears healthy. || Large potted tree visible on the right side (west zone). Leaves are dark green and dense, indicating good health. || Plants on the left shelving units appear upright and healthy. The 'Lime Tree' label may refer to the larger potted plants or the general collection in this zone. || Potted plant visible on the ri
Hanging baskets visible in the center. Roots appear exposed and healthy. No obvious wilting or discoloration visible in IR. || Hanging baskets visible in the upper center area. Roots appear white and healthy; foliage is green and turgid. || Hanging baskets visible in the upper center. Roots appear exposed and healthy. No obvious signs of wilting or leaf drop in the infrared view. || [root exposure, potential desiccation] Hanging baskets visible in the center. Roots appear exposed and dry, which is typical for Vandae but requires monitoring given the 64% humidity. || [root exposure] Hanging orchids visible in the upper center. Roots appear dry and exposed, which is typical for Vanda but requires monitoring given the 63.8% RH.
Seedlings visible in the blue trays on the left-side shelving. They appear upright and green, though the low light conditions (0 lux) suggest they are relying on supplemental lighting or are in a resting phase. || [potential nutrient deficiency, wilting] Seedlings visible in blue trays on the left shelving. Some plants appear leggy and pale, suggesting light stress or nutrient issues. The 0 lux reading is likely a sensor error given the visible daylight. || [wilting, drooping] Hanging plants in the east zone (right side) show significant drooping and wilting, likely due to the reported 0% soil moisture in the south zone or general irrigation issues. || [wilting] Seedlings in blue trays on the left rack appear somewhat leggy and potentially under-watered or stressed due to low light conditions.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 75.0°F | 1.19 kPa | 60.5% |
| 13:00 | 76.5°F | 1.18 kPa | 62.0% |
| 14:00 | 76.8°F | 1.18 kPa | 62.6% |
| 15:00 | 76.1°F | 1.18 kPa | 61.6% |
| 16:00 | 76.4°F | 1.12 kPa | 63.9% |
| 17:00 | 74.6°F | 1.03 kPa | 64.9% |
| 18:00 | 73.0°F | 0.99 kPa | 64.6% |
| 19:00 | 70.1°F | 0.92 kPa | 63.9% |
| 20:00 | 69.8°F | 0.94 kPa | 62.4% |
| 21:00 | 67.4°F | 0.86 kPa | 63.0% |
| 22:00 | 64.5°F | 0.72 kPa | 65.2% |
| 23:00 | 62.6°F | 0.65 kPa | 66.4% |
| 00:00 | 61.5°F | 0.61 kPa | 67.5% |
| 01:00 | 61.0°F | 0.58 kPa | 68.1% |
| 02:00 | 60.3°F | 0.57 kPa | 68.4% |
| 03:00 | 59.6°F | 0.55 kPa | 68.7% |
| 04:00 | 61.4°F | 0.61 kPa | 67.3% |
| 05:00 | 61.6°F | 0.63 kPa | 66.6% |
| 06:00 | 62.8°F | 0.69 kPa | 64.6% |
| 07:00 | 64.1°F | 0.78 kPa | 62.2% |
| 08:00 | 66.4°F | 0.89 kPa | 59.9% |
| 09:00 | 68.9°F | 1.03 kPa | 57.5% |
| 10:00 | 70.8°F | 1.13 kPa | 56.3% |
| 11:00 | 73.2°F | 1.13 kPa | 59.4% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-19 | 0.0h | 6.2h | 15.6h |
| 2026-10-20 | 0.6h | 6.5h | 15.5h |
| 2026-10-21 | 0.0h | 8.4h | 14.7h |
| 2026-10-22 | 0.0h | 7.3h | 14.9h |
| 2026-10-23 | 0.5h | 6.5h | 14.7h |
| 2026-10-24 | 0.0h | 7.5h | 15.8h |
| 2026-10-25 | 0.0h | 8.7h | 16.2h |