October 26, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
3
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:17 | MIDNIGHT | plan_written | Wrote public plan iris-20261026-0017. Resolved 00:19 MDT. |
| Morning planning cycle | 07:25 | SUNRISE | plan_written | Wrote public plan iris-20261026-0725. Resolved 07:29 MDT. |
| Forecast deviation | 11:17 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261026-1117. Resolved 11:20 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | acked | Acknowledged: No nudge: live solar 401 W/m² tracks the provisional bias-adjusted 14:00 peak (~408); indoor VPD is 0.60, below high 0.99 and has only modestly rebounded from 0.40, with dew margin 6.3°F and an open too-wet alert. Existing measure-gated plan remains appropriate. Resolved 12:48 MDT. |
| Peak Stress | 14:46 | TRANSITION | acked | Acknowledged: Peak-stress checkpoint shows no actionable VPD-high or heat miss: fresh house reading 78.5°F/0.64 kPa is below the 0.99 kPa VPD high edge, mode IDLE, vent/fans/fog/misters off, and dew margin 6.3°F. Keep current plan/tunables; avoid extra wetting near condensation-risk margin. Resolved 14:47 MDT. |
| Decline | 17:06 | TRANSITION | acked | Acknowledged: Decline is tracking: house 75.1°F/0.47 kPa with 5.1°F dew margin; heat1 on, vent/fog/misters off. VPD is just above the 0.44 low edge, pulse gap is already 60s, and a cold/humid rebound is forecast. No tunable change warranted. Resolved 17:07 MDT. |
| Evening planning cycle | 18:06 | SUNSET | plan_written | Wrote public plan iris-20261026-1806. Resolved 18:10 MDT. |
🌅 Morning Cycle (12:19 AM) — iris-20261026-0017
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-1808
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:51,“outdoor_rh_min_pct”:64,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:94.583,“notes”:“Fresh 19:00–06:00 forecast: 51°F peak falling to 45°F; RH 64–96%, outdoor VPD 0.04–0.46, cloud average 94.583%. Indoors 72.1°F, VPD 0.96, dew margin 12.5°F. Oct 25 score 74.6; cold and VPD-high stress dominated; costs and physical crop outcomes unavailable. Prior 0725 self-score 4 vs anchor 1 (+3): limited short-window VPD success, but weak temperature compliance and missing physical/resource evidence; grade remains uncertain, not causal.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-25T22:00:00-06:00”,“end”:“2026-10-26T07:00:00-06:00”,“severity”:“medium”,“mitigation”:“Keep exchange conservative as outdoor falls to 45°F; retain normal firmware heat staging and avoid band changes… Result: Scoped 2026-10-26 00:19–02:04 window: contract-2 house-average temp compliance 0%, VPD compliance 100%; nominal cold stress 0.49h and no heat/VPD-high/VPD-low stress. This is a short overnight window; current indoor VPD was below the high edge and heating was active, but dew margin and resource cost are not scoped. Coverage is unverified and no physical crop/fixed-panel evidence is eligible. Cold pressure was expected; limited partial support for measurement-gated moisture, not causal proof. Score: 5/10
Hypothesis
Testing: Observational cold, saturated dawn posture; keep wet assist measurement-gated until a live VPD edge appears. Expected outcome: Maintain dew margin >=8°F and avoid VPD-low/wet overshoot; retain live-edge assistance without forecast-only misting. Cold stress may persist; no physical crop outcome is claimed.
Setpoints
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:18 | hyst 0.21750000000000003 | Post-midnight: measured VPD is in-band; avoid forecast-only |
| 04:45 | hyst 0.21750000000000003 | Pre-dawn: retain stable heating; humid 43–45°F outdoor air d |
| 07:15 | hyst 0.21750000000000003 | Sunrise ramp: keep moisture band-coupled; no solar precoolin |
| 10:30 | hyst 0.21750000000000003 | Early-day handoff: permit assist only on observed VPD edge; |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:18 | s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.855; all 1.055; pulse 30; gap 60; wt 1.3 | Post-midnight: measured VPD is in-band; avoid forecast-only |
| 04:45 | s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.855; all 1.055; pulse 30; gap 60; wt 1.3 | Pre-dawn: retain stable heating; humid 43–45°F outdoor air d |
| 07:15 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 45; wt 1.5 | Sunrise ramp: keep moisture band-coupled; no solar precoolin |
| 10:30 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 45; wt 1.5333333333333332 | Early-day handoff: permit assist only on observed VPD edge; |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:18 | band_track_fraction | initial 0 |
| 00:18 | cold_vent_guard_delta_f | initial 9 |
| 00:18 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:18 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:18 | direct_wet_stress_vpd_margin_kpa | initial 0.1 |
| 00:18 | dwell_gate_ms | initial 300000 |
| 00:18 | enthalpy_close | initial 1 |
| 00:18 | enthalpy_open | initial -2 |
| 00:18 | fog_escalation_kpa | initial 0.4 |
| 00:18 | heat_hysteresis | initial 1 |
| 00:18 | min_fog_off_s | initial 108 |
| 00:18 | min_fog_on_s | initial 45.75 |
| 00:18 | mist_backoff_s | initial 600 |
| 00:18 | mist_max_closed_vent_s | initial 600 |
| 00:18 | mist_thermal_relief_s | initial 90 |
| 00:18 | mister_all_delay_s | initial 102 |
| 00:18 | mister_engage_delay_s | initial 51 |
| 00:18 | mister_water_budget_gal | initial 120 |
| 00:18 | night_vpd_bias_kpa | initial 0 |
| 00:18 | outdoor_staleness_max_s | initial 600 |
| 00:18 | sw_dwell_gate_enabled | initial 1 |
| 00:18 | sw_fog_closes_vent | initial 1 |
| 00:18 | sw_mister_closes_vent | initial 0 |
| 00:18 | sw_summer_vent_enabled | initial 1 |
| 00:18 | temp_hysteresis | initial 2.14 |
| 00:18 | vent_exchange_fraction | initial 0.3 |
| 00:18 | vent_prefer_dp_delta_f | initial 4 |
| 00:18 | vent_prefer_temp_delta_f | initial 5 |
| 00:18 | vpd_watch_dwell_s | initial 75 |
| 07:15 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 07:15 | fog_escalation_kpa | 0.4 → 0.35 |
| 07:15 | min_fog_off_s | 108 → 78 |
| 07:15 | min_fog_on_s | 45.75 → 57 |
🌅 Morning Cycle (2:04 AM) — iris-20261026-0203
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261025-1808
Result: Scoped window for iris-20261026-0203 was a short early-morning interval. Window scorecard reports contract-2 house-average temp compliance 1.9% and VPD compliance 92.7%; nominal cold stress 2.32h, VPD-high 0.17h, VPD-low 0h, with no scored heat/dew-risk hours. This broadly matched the cold/saturated-weather expectation and avoided VPD-low, but temp remained poor. Resource terms, coverage, fixed-panel and physical-crop evidence are unavailable; daily planner score 72.2 is not causal evidence for this window. Conservative partial result, no durable lesson. Score: 4/10
Hypothesis
Testing: Weekly posture test: conservative wetting through cold saturated periods, then measured band-coupled assist before the forecast Oct 28 dry ramp. Expected outcome: Oct 28 VPD-high stress <6h, VPD-low stress 0h and dew-risk 0h; evaluate contract-2 scorecard only, with no physical crop or causal claim.
Setpoints
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 02:03 | hyst 0.20750000000000002 | Cold saturated dawn; preserve heat and dew margin; wet only |
| 10:00 | hyst 0.20750000000000002 | Cloudy, cool daytime; maintain measured-only moisture suppor |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 02:03 | s2 1.9225; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.889; all 1.089; pulse 30; gap 60; wt 1.2666666666666666 | Cold saturated dawn; preserve heat and dew margin; wet only |
| 10:00 | s2 1.9075000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.839; all 1.039; pulse 30; gap 60; wt 1.3333333333333333 | Cloudy, cool daytime; maintain measured-only moisture suppor |
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.20750000000000002 | Saturated cold dawn forecast; hold conservative wetting unti |
| 14:00 | hyst 0.20750000000000002 | Ahead of Tuesday's drier rise, make moderate wet assist avai |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.9225; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9390000000000001; all 1.139; pulse 30; gap 60; wt 1.2666666666666666 | Saturated cold dawn forecast; hold conservative wetting unti |
| 14:00 | s2 1.7887500000000003; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.789; all 1; pulse 33.75; gap 45; wt 1.5666666666666667 | Ahead of Tuesday's drier rise, make moderate wet assist avai |
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.1975 | Forecast dry, sunny ramp; keep band-coupled wet assist ready |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.7; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.789; all 1; pulse 37.5; gap 33.75; wt 1.7000000000000002 | Forecast dry, sunny ramp; keep band-coupled wet assist ready |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 02:03 | band_track_fraction | initial 0 |
| 02:03 | cold_vent_guard_delta_f | initial 10 |
| 02:03 | cool_stage2_exit_hysteresis_f | initial 1 |
| 02:03 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 02:03 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 02:03 | dwell_gate_ms | initial 270000 |
| 02:03 | enthalpy_close | initial 1 |
| 02:03 | enthalpy_open | initial -2 |
| 02:03 | fog_escalation_kpa | initial 0.35 |
| 02:03 | heat_hysteresis | initial 1 |
| 02:03 | min_fog_off_s | initial 114 |
| 02:03 | min_fog_on_s | initial 43.5 |
| 02:03 | mist_backoff_s | initial 600 |
| 02:03 | mist_max_closed_vent_s | initial 600 |
| 02:03 | mist_thermal_relief_s | initial 90 |
| 02:03 | mister_all_delay_s | initial 93 |
| 02:03 | mister_engage_delay_s | initial 46.5 |
| 02:03 | mister_water_budget_gal | initial 120 |
| 02:03 | night_vpd_bias_kpa | initial 0 |
| 02:03 | outdoor_staleness_max_s | initial 600 |
| 02:03 | sw_dwell_gate_enabled | initial 1 |
| 02:03 | sw_fog_closes_vent | initial 1 |
| 02:03 | sw_mister_closes_vent | initial 0 |
| 02:03 | sw_summer_vent_enabled | initial 1 |
| 02:03 | temp_hysteresis | initial 1.96 |
| 02:03 | vent_exchange_fraction | initial 0.3 |
| 02:03 | vent_prefer_dp_delta_f | initial 5 |
| 02:03 | vent_prefer_temp_delta_f | initial 6 |
| 02:03 | vpd_watch_dwell_s | initial 67.5 |
| 10:00 | cold_vent_guard_delta_f | 10 → 9 |
| 10:00 | direct_wet_stress_min_dew_margin_f | 10 → 9 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 10:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 10:00 | min_fog_off_s | 114 → 108 |
| 10:00 | min_fog_on_s | 43.5 → 45.75 |
| 10:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 10:00 | vent_prefer_temp_delta_f | 6 → 5 |
| 08:00 | cold_vent_guard_delta_f | 9 → 10 |
| 08:00 | direct_wet_stress_min_dew_margin_f | 9 → 10 |
| 08:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.2 |
| 08:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 08:00 | min_fog_off_s | 108 → 114 |
| 08:00 | min_fog_on_s | 45.75 → 43.5 |
| 08:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 08:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 14:00 | cold_vent_guard_delta_f | 10 → 8 |
| 14:00 | direct_wet_stress_min_dew_margin_f | 10 → 8.5 |
| 14:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.05 |
| 14:00 | fog_escalation_kpa | 0.4 → 0.25 |
| 14:00 | min_fog_off_s | 114 → 78 |
| 14:00 | min_fog_on_s | 43.5 → 57 |
| 14:00 | vent_prefer_dp_delta_f | 5 → 3 |
| 14:00 | vent_prefer_temp_delta_f | 6 → 4 |
| 08:00 | direct_wet_stress_min_dew_margin_f | 8.5 → 8 |
| 08:00 | dwell_gate_ms | 270000 → 240000 |
| 08:00 | fog_escalation_kpa | 0.25 → 0.2 |
| 08:00 | min_fog_off_s | 78 → 60 |
| 08:00 | min_fog_on_s | 57 → 63.75 |
| 08:00 | mister_all_delay_s | 93 → 84 |
| 08:00 | mister_engage_delay_s | 46.5 → 42 |
| 08:00 | temp_hysteresis | 1.96 → 1.78 |
| 08:00 | vpd_watch_dwell_s | 67.5 → 60 |
🌅 Morning Cycle (7:29 AM) — iris-20261026-0725
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261026-0017
Previous hypothesis: Oct 25 plan iris-20261025-1133 scored 74.2 in its scoped window: binary both-axis 1.2%, temp 27.7%, VPD 59.7%; 4.32h cold and 2.32h VPD-high, with no heat/VPD-low or dew-risk hours. I graded 4 vs deterministic anchor 1 (+3): I credited the appropriate response to the clear-sky forecast miss and avoiding forecast-only wetting, while the anchor reflects poor served-band outcomes; missing resource and physical-crop evidence prevents stronger credit. No durable lesson is supported. Today is cold and saturated/overcast (44–52°F, mostly 85–100% RH, little solar); current house is 62.2°F/0.64 kPa, within the active VPD corridor, with 11.2°F dew margin and heating active. Keep pre-dawn wetting measurement-gated, prioritize stable heat and condensation margin, then allow only bounded live-edge assist at the morning handoff… Result: The completed iris-20261026-0725 window ran 2026-10-26 07:29–11:20 MDT. Its assembled per-plan scorecard row reports 22.2% both-axis, 28.3% temp, 71.4% VPD, 0.00h heat, 2.57h cold, 0.14h VPD-high, 0.88h VPD-low, and 0.00h dew-risk; these are historical setpoint diagnostics with unverified coverage, not physical crop outcomes. The cold pressure broadly matched the forecast, but temperature performance was poor and the no-VPD-low expectation was missed. The planned Oct 28 dry-ramp outcome was not yet observable at this review, so it cannot be credited. Full Oct 26 scorecard was 60.8, with 28.3% temp and 71.4% VPD binary fractions, 22.47 nominal stress hours (16.07 cold, 5.50 VPD-low), water 172 gal, and 4.7 dp-risk hours; daily metrics are not attributable to this short window. Resource cost, coverage, fixed-panel, and physical crop evidence are unavailable. No durable causal lesson supported. Score: 3/10
Hypothesis
Testing: Measure-gated wet assist through cold/cloudy conditions; open band-coupled mist/fog only at the live VPD-high edge before Wednesday’s dry ramp. Expected outcome: On Wed Oct 28, target contract-2 daily VPD-high stress <6h, VPD-low 0h, and dew-risk 0h. Outdoor VPD is not an indoor outcome; resource cost and physical crop evidence remain unqualified.
Conditions
71.0°F
13.0%
529.0 W/m²
82.0%
Cold, cloudy Mon/Tue then dry/solar Wed; outdoor VPD is not indoor. Forecast alert cites 82% mean cloud over next 48h. Eval calibration: I rated windows 1808/0017 5/10 vs anchors 1; overcredited no VPD stress despite 0% temp compliance and missing resource/fixed-panel proof. No causal lesson.
Expected stress windows
Keep ordinary heat staging; no wetting from outdoor conditions; preserve dew margin.
Offer band-coupled mist/fog at measured VPD-high edge; no forecast-only wetting.
Parameter rationale
Use wet assist only at measured high+0.05; aim for Wed VPD-high <6h, VPD-low 0h and dew-risk 0h.
Permit guarded fog only if indoor VPD remains high and firmware safety gates allow; avoid forecast-only fog.
Setpoints
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:25 | hyst 0.1975 | Dawn: cold saturated air; use measured VPD only and protect |
| 10:00 | hyst 0.1975 | Morning ramp: cloudy and cool; allow only live band-edge wet |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:25 | s2 1.995; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.206; pulse 30; gap 60; wt 1.3 | Dawn: cold saturated air; use measured VPD only and protect |
| 10:00 | s2 1.98; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 60; wt 1.3666666666666667 | Morning ramp: cloudy and cool; allow only live band-edge wet |
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.1975 | Peak stress: open band-coupled wet assist only on measured V |
| 16:00 | hyst 0.1975 | Decline: retain recovery assist until observed indoor VPD cl |
| 19:00 | hyst 0.1975 | Evening: taper only after measured recovery; keep dew guard |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.7575; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.9560000000000001; all 1.1560000000000001; pulse 41.25; gap 26.25; wt 1.7999999999999998 | Peak stress: open band-coupled wet assist only on measured V |
| 16:00 | s2 1.86; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.9560000000000001; all 1.1560000000000001; pulse 37.5; gap 30; wt 1.7333333333333334 | Decline: retain recovery assist until observed indoor VPD cl |
| 19:00 | s2 1.905; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 41.25; wt 1.5666666666666669 | Evening: taper only after measured recovery; keep dew guard |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:25 | band_track_fraction | initial 0 |
| 07:25 | cold_vent_guard_delta_f | initial 9 |
| 07:25 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:25 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:25 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 07:25 | dwell_gate_ms | initial 240000 |
| 07:25 | enthalpy_close | initial 1 |
| 07:25 | enthalpy_open | initial -2 |
| 07:25 | fog_escalation_kpa | initial 0.35 |
| 07:25 | heat_hysteresis | initial 1 |
| 07:25 | min_fog_off_s | initial 108 |
| 07:25 | min_fog_on_s | initial 45.75 |
| 07:25 | mist_backoff_s | initial 600 |
| 07:25 | mist_max_closed_vent_s | initial 600 |
| 07:25 | mist_thermal_relief_s | initial 90 |
| 07:25 | mister_all_delay_s | initial 84 |
| 07:25 | mister_engage_delay_s | initial 42 |
| 07:25 | mister_water_budget_gal | initial 120 |
| 07:25 | night_vpd_bias_kpa | initial 0 |
| 07:25 | outdoor_staleness_max_s | initial 600 |
| 07:25 | sw_dwell_gate_enabled | initial 1 |
| 07:25 | sw_fog_closes_vent | initial 1 |
| 07:25 | sw_mister_closes_vent | initial 0 |
| 07:25 | sw_summer_vent_enabled | initial 1 |
| 07:25 | temp_hysteresis | initial 1.78 |
| 07:25 | vent_exchange_fraction | initial 0.3 |
| 07:25 | vent_prefer_dp_delta_f | initial 5 |
| 07:25 | vent_prefer_temp_delta_f | initial 5 |
| 07:25 | vpd_watch_dwell_s | initial 60 |
| 10:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 10:00 | min_fog_off_s | 108 → 102 |
| 10:00 | min_fog_on_s | 45.75 → 48 |
| 10:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 12:00 | cold_vent_guard_delta_f | 9 → 8 |
| 12:00 | fog_escalation_kpa | 0.3 → 0.2 |
| 12:00 | min_fog_off_s | 102 → 48 |
| 12:00 | min_fog_on_s | 48 → 68.25 |
| 12:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 12:00 | vent_prefer_temp_delta_f | 5 → 4 |
| 16:00 | min_fog_off_s | 48 → 54 |
| 16:00 | min_fog_on_s | 68.25 → 66 |
| 19:00 | cold_vent_guard_delta_f | 8 → 9 |
| 19:00 | fog_escalation_kpa | 0.2 → 0.35 |
| 19:00 | min_fog_off_s | 54 → 72 |
| 19:00 | min_fog_on_s | 66 → 59.25 |
| 19:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 19:00 | vent_prefer_temp_delta_f | 4 → 5 |
☀️ Midday Cycle (11:20 AM) — iris-20261026-1117
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261026-0203
Previous hypothesis: Weekly evidence (Oct 19-25): contract-2 planner scores stayed 73.7-77.5 (7-day mean 75.8), but binary temp compliance was 28.7-36.6% and VPD 61.8-73.4%; nominal stress was 21.7-24.9h/day, mainly cold (14.7-16.2h) plus VPD-high (6.2-8.7h), with no VPD-low or dew-risk hours. These are historical controller-credit/house-average diagnostics, not measured crop outcomes. Resource weights were 0%; reliable cost/energy data were null and water was incomplete. Current indoor air is 61.3F/0.58kPa with 10.5F dew margin; cold saturated weather persists through Tue morning, then a dry clear ramp is forecast Wed (outdoor VPD up to 2.33kPa). Keep wet assist restrained while measured air is below band, then open band-coupled assist for measured VPD excess; do not wet from outdoor forecast alone… Result: Scoped 2026-10-26 11:20–18:06 window per plan window scorecard: planner score 65.7; contract-2 legacy house-average both-axis compliance 26.4%, temp 34.1%, VPD 86.3%; nominal cold stress 3.11h, VPD-high 0.25h, VPD-low 0.34h, heat and dew-risk 0h. This is a partial result: VPD stayed comparatively strong with little VPD stress, but temperature compliance remained weak and cold stress dominated. The cloud forecast missed a clear break; the plan’s Oct 28 expected outcome is not yet testable. Cost/resource evidence is null, coverage is unverified, and fixed-panel/physical-crop evidence is unavailable, so no causal claim or durable lesson is supported. Score: 4/10
Hypothesis
Testing: Measure-gated wet assist through cold/cloudy conditions; open band-coupled mist/fog only at the live VPD-high edge before Wednesday’s dry ramp. Expected outcome: On Wed Oct 28, target contract-2 daily VPD-high stress <6h, VPD-low 0h, and dew-risk 0h. Outdoor VPD is not an indoor outcome; resource cost and physical crop evidence remain unqualified.
Setpoints
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 11:17 | hyst 0.1975 | Clear-sky miss is outdoor-only; house is in corridor. Hold c |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 11:17 | s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.207; all 1.407; pulse 30; gap 45; wt 1.5333333333333332 | Clear-sky miss is outdoor-only; house is in corridor. Hold c |
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | hyst 0.1975 | Cold, saturated forecast; retain heat priority and restrain |
| 14:30 | hyst 0.1975 | Moderate Tue dry ramp; allow limited band-edge moisture only |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | s2 1.8475000000000001; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.307; all 1.457; pulse 30; gap 48.75; wt 1.4666666666666668 | Cold, saturated forecast; retain heat priority and restrain |
| 14:30 | s2 1.7974999999999999; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.2570000000000001; all 1.407; pulse 30; gap 45; wt 1.5333333333333332 | Moderate Tue dry ramp; allow limited band-edge moisture only |
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | hyst 0.1975 | Wed dry ramp; open bounded band-coupled assist at measured V |
| 17:00 | hyst 0.1975 | Recovery shoulder only while observed VPD stays high; fog re |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:30 | s2 1.7; cool_exit 1.78; all_fans 0; dw_stress 1; engage 1.207; all 1.407; pulse 41.25; gap 33.75; wt 1.7333333333333334 | Wed dry ramp; open bounded band-coupled assist at measured V |
| 17:00 | s2 1.8175000000000001; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.207; all 1.407; pulse 33.75; gap 41.25; wt 1.6 | Recovery shoulder only while observed VPD stays high; fog re |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 11:17 | band_track_fraction | initial 0 |
| 11:17 | cold_vent_guard_delta_f | initial 8 |
| 11:17 | cool_stage2_exit_hysteresis_f | initial 1 |
| 11:17 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 11:17 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 11:17 | dwell_gate_ms | initial 240000 |
| 11:17 | enthalpy_close | initial 1 |
| 11:17 | enthalpy_open | initial -2 |
| 11:17 | fog_escalation_kpa | initial 0.35 |
| 11:17 | heat_hysteresis | initial 1 |
| 11:17 | min_fog_off_s | initial 78 |
| 11:17 | min_fog_on_s | initial 57 |
| 11:17 | mist_backoff_s | initial 600 |
| 11:17 | mist_max_closed_vent_s | initial 600 |
| 11:17 | mist_thermal_relief_s | initial 90 |
| 11:17 | mister_all_delay_s | initial 84 |
| 11:17 | mister_engage_delay_s | initial 42 |
| 11:17 | mister_water_budget_gal | initial 120 |
| 11:17 | night_vpd_bias_kpa | initial 0 |
| 11:17 | outdoor_staleness_max_s | initial 600 |
| 11:17 | sw_dwell_gate_enabled | initial 1 |
| 11:17 | sw_fog_closes_vent | initial 1 |
| 11:17 | sw_mister_closes_vent | initial 0 |
| 11:17 | sw_summer_vent_enabled | initial 1 |
| 11:17 | temp_hysteresis | initial 1.78 |
| 11:17 | vent_exchange_fraction | initial 0.3 |
| 11:17 | vent_prefer_dp_delta_f | initial 3 |
| 11:17 | vent_prefer_temp_delta_f | initial 4 |
| 11:17 | vpd_watch_dwell_s | initial 60 |
| 08:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.15 |
| 08:30 | min_fog_off_s | 78 → 84 |
| 08:30 | min_fog_on_s | 57 → 54.75 |
| 14:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 14:30 | fog_escalation_kpa | 0.35 → 0.3 |
| 14:30 | min_fog_off_s | 84 → 78 |
| 14:30 | min_fog_on_s | 54.75 → 57 |
| 08:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 08:30 | fog_escalation_kpa | 0.3 → 0.2 |
| 08:30 | min_fog_off_s | 78 → 60 |
| 08:30 | min_fog_on_s | 57 → 63.75 |
| 17:00 | fog_escalation_kpa | 0.2 → 0.25 |
| 17:00 | min_fog_off_s | 60 → 72 |
| 17:00 | min_fog_on_s | 63.75 → 59.25 |
🌆 Evening Cycle (6:10 PM) — iris-20261026-1806
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261026-1117
Previous hypothesis: Observed cloud is 0% versus forecast 100%, with 307 W/m² solar; this is a real local clearing/near-term forecast miss, not equipment failure. Outdoor 45.4°F/81% RH and house 72.4°F/0.96 kPa with 12.5°F dew margin; heat1 is on, vent/fans/wet devices off, and current temp/VPD remain inside dispatcher corridors. No calibrated cloud-bias history exists, so keep today’s cool/humid posture and avoid forecast-only wetting; retain measured band-edge wet assist for the later dry ramp. Prior plan iris-20261026-0203 was scored 4 vs anchor 1: I credited zero VPD-low stress, while the anchor reflects very poor temp compliance; missing resource and physical-crop evidence makes the favorable part uncertain. Result: Scoped window for iris-20261026-1806 (per-plan window scorecard, not full-day summary): legacy house-average both-axis compliance 0%, temp 0%, VPD 7.2%; nominal cold stress 1.73h and VPD-low stress 1.61h, with heat, VPD-high and dew-risk hours at 0; planner score 34.2. The plan expected overnight VPD-low and dew-risk each below 1h while cold stress could persist. Dew-risk objective was met, but VPD-low exceeded target by 0.61h and temperature compliance remained 0%; partial outcome, not a broad success. Coverage is unverified and physical crop/fixed-panel evidence is unavailable, so no causal claim or durable lesson. Score: 3/10
Hypothesis
Testing: Cold-saturated night: test measurement-gated wet assist with a high dew-margin floor and churn-aware overnight posture. Expected outcome: Over the overnight window, target VPD-low stress <1h and dew-risk <1h while avoiding VPD-high breakout; cold stress may persist in 42F air. Dollar costs remain unqualified.
Conditions
46.0°F
90.0%
0.0 W/m²
65.75%
Forecast cloud mean 65.75% for 19:00 Oct 26–06:00 Oct 27; outdoor 46F falling to 42F, RH 90–100%, VPD near zero. House is 74F/VPD 0.49 with 5.4F dew margin. Oct 26 score 66.7, temp 34.6% vs VPD 87.6%; cold stress dominated. Previous plan graded 4 vs anchor 3. Cost, coverage, and physical crop evidence are unavailable.
Expected stress windows
Preserve heat; avoid unnecessary outdoor exchange and wetting; retain stable dwell without changing crop bands.
Suppress forecast-only wetting; require measured VPD excess and healthy dew margin before moisture assist.
Parameter rationale
Keep wet assist restrained until measured demand and a safe dew margin; aim for overnight VPD-low and dew-risk each below 1h.
Setpoints
Monday October 26
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:06 | hyst 0.2175 | Evening settle: protect heat; VPD is in range but dew margin |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:06 | s2 1.835; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.146; all 1.346; pulse 30; gap 60; wt 1.28 | Evening settle: protect heat; VPD is in range but dew margin |
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.22249999999999998 | Midnight: cold saturated air raises VPD-low/dew risk; minimi |
| 04:30 | hyst 0.2175 | Pre-dawn: maintain restrained wetting and stable heat throug |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.85; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.196; all 1.446; pulse 30; gap 60; wt 1.2 | Midnight: cold saturated air raises VPD-low/dew risk; minimi |
| 04:30 | s2 1.835; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.146; all 1.346; pulse 30; gap 60; wt 1.2666666666666666 | Pre-dawn: maintain restrained wetting and stable heat throug |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:06 | band_track_fraction | initial 0 |
| 18:06 | cold_vent_guard_delta_f | initial 9 |
| 18:06 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:06 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:06 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 18:06 | dwell_gate_ms | initial 300000 |
| 18:06 | enthalpy_close | initial 1 |
| 18:06 | enthalpy_open | initial -2 |
| 18:06 | fog_escalation_kpa | initial 0.5 |
| 18:06 | heat_hysteresis | initial 1 |
| 18:06 | min_fog_off_s | initial 114 |
| 18:06 | min_fog_on_s | initial 43.5 |
| 18:06 | mist_backoff_s | initial 600 |
| 18:06 | mist_max_closed_vent_s | initial 600 |
| 18:06 | mist_thermal_relief_s | initial 90 |
| 18:06 | mister_all_delay_s | initial 102 |
| 18:06 | mister_engage_delay_s | initial 51 |
| 18:06 | mister_water_budget_gal | initial 120 |
| 18:06 | night_vpd_bias_kpa | initial 0 |
| 18:06 | outdoor_staleness_max_s | initial 600 |
| 18:06 | sw_dwell_gate_enabled | initial 1 |
| 18:06 | sw_fog_closes_vent | initial 1 |
| 18:06 | sw_mister_closes_vent | initial 0 |
| 18:06 | sw_summer_vent_enabled | initial 1 |
| 18:06 | temp_hysteresis | initial 2.14 |
| 18:06 | vent_exchange_fraction | initial 0.3 |
| 18:06 | vent_prefer_dp_delta_f | initial 4 |
| 18:06 | vent_prefer_temp_delta_f | initial 5 |
| 18:06 | vpd_watch_dwell_s | initial 75 |
| 00:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.25 |
| 00:00 | dwell_gate_ms | 300000 → 315000 |
| 00:00 | min_fog_off_s | 114 → 120 |
| 00:00 | min_fog_on_s | 43.5 → 41.25 |
| 00:00 | mister_all_delay_s | 102 → 106.5 |
| 00:00 | mister_engage_delay_s | 51 → 53.25 |
| 00:00 | temp_hysteresis | 2.14 → 2.23 |
| 00:00 | vpd_watch_dwell_s | 75 → 78.75 |
| 04:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.2 |
| 04:30 | dwell_gate_ms | 315000 → 300000 |
| 04:30 | min_fog_off_s | 120 → 114 |
| 04:30 | min_fog_on_s | 41.25 → 43.5 |
| 04:30 | mister_all_delay_s | 106.5 → 102 |
| 04:30 | mister_engage_delay_s | 53.25 → 51 |
| 04:30 | temp_hysteresis | 2.23 → 2.14 |
| 04:30 | vpd_watch_dwell_s | 78.75 → 75 |
End-of-Day Summary
Climate
59.7–79.9°F; avg 68.5°F
0.29–1.12 kPa; avg 0.57 kPa
59.5–89.4%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 0.9h
- Cold stress (<55°F): 16.5h
Economics
Not available
USD 1.72
USD 0.830
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 2 min | Primary exhaust runtime. |
| Fan 2 | 4 min | Secondary exhaust runtime. |
| Vent | 6 min | Intake vent runtime. |
| Fog | 0 min | Fogger runtime. |
| Heat 1 electric | 1203 min | Electric heater runtime. |
| Heat 2 gas | 166 min | Gas heater runtime. |
| Grow lights | 1346 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 172 gal
- Mister: 0 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 60% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 65% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 48% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Located on the shelving units on the left. Foliage appears dense and upright. No obvious signs of yellowing or pest damage visible in this lighting. || Small potted plants on the right shelving (west zone). Hard to assess specific health due to distance and lighting, but no immediate collapse or major pest damage visible. || Vegetative growth is visible in the lower right corner; leaves appear green and turgid, though the specific soil moisture data is missing. || [low light] Located in the west zone. The lack of light (0 lux) is a significant stressor for a fruit tree, even in a vegetative stage. The soil moisture reading is unavailable', which is likely a sensor error or indicates a dry state. || [unknown moisture status] Potted citrus visible on the right side. Soil moisture data is missing (unavailable'), making it difficult to assess hydration status, though foliage appears green. || [unknown soil moisture, low light] Tree is visible in the west zone. The soil moisture reading is unavailable', i
Hanging orchids visible in the center. Roots appear exposed and healthy. No obvious signs of wilting or discoloration in the infrared spectrum. || [high humidity, low light] Hanging baskets visible in the center. Roots appear exposed and healthy, but the 0 lux light level indicates the plants are in a dark cycle or lights are off. High humidity (85.1%) is suitable for Vanda but requires good airflow to prevent rot. || [root desiccation risk, low light] Hanging baskets visible in the center. Roots appear exposed and potentially dry, which is critical for Vanda orchids. The 0 lux reading suggests a lack of supplemental lighting or a sensor error, which is detrimental to orchid growth. || [root exposure] Hanging baskets visible in the center background. Roots are exposed as expected for Vanda, but the low light (0 lux) and high humidity (82.8%) are critical for their health. No obvious yellowing or browning visible from this distance.
Seedlings appear upright and healthy on the shelving unit. No visible signs of wilting or yellowing in the infrared spectrum. || [wilting, desiccation] Seedlings in the blue trays on the left rack appear significantly wilted and dry, likely due to the 0.0% soil moisture reading. || [wilting, drooping] Visible in the lower right corner. The plant appears to be drooping significantly, suggesting water stress or root issues, despite the high humidity. || [wilting, drying] Seedlings in blue trays on the left rack appear dry and wilted, consistent with the 0.0% soil moisture reading.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 74.7°F | 1.19 kPa | 59.7% |
| 13:00 | 76.1°F | 1.10 kPa | 64.2% |
| 14:00 | 77.3°F | 1.10 kPa | 65.8% |
| 15:00 | 77.5°F | 1.19 kPa | 63.0% |
| 16:00 | 78.3°F | 1.12 kPa | 66.3% |
| 17:00 | 74.2°F | 1.03 kPa | 64.4% |
| 18:00 | 73.4°F | 1.05 kPa | 63.0% |
| 19:00 | 71.4°F | 0.97 kPa | 63.3% |
| 20:00 | 69.0°F | 0.89 kPa | 63.7% |
| 21:00 | 67.1°F | 0.82 kPa | 64.3% |
| 22:00 | 64.6°F | 0.71 kPa | 65.8% |
| 23:00 | 63.1°F | 0.66 kPa | 66.5% |
| 00:00 | 62.0°F | 0.63 kPa | 67.1% |
| 01:00 | 61.5°F | 0.60 kPa | 67.9% |
| 02:00 | 61.0°F | 0.57 kPa | 68.9% |
| 03:00 | 60.4°F | 0.54 kPa | 69.9% |
| 04:00 | 60.0°F | 0.52 kPa | 70.8% |
| 05:00 | 62.1°F | 0.57 kPa | 70.0% |
| 06:00 | 62.8°F | 0.60 kPa | 69.2% |
| 07:00 | 64.0°F | 0.68 kPa | 67.0% |
| 08:00 | 66.4°F | 0.80 kPa | 64.2% |
| 09:00 | 68.7°F | 0.91 kPa | 62.2% |
| 10:00 | 71.2°F | 1.01 kPa | 61.4% |
| 11:00 | 72.8°F | 0.74 kPa | 73.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-20 | 0.6h | 6.5h | 15.5h |
| 2026-10-21 | 0.0h | 8.4h | 14.7h |
| 2026-10-22 | 0.0h | 7.3h | 14.9h |
| 2026-10-23 | 0.5h | 6.5h | 14.7h |
| 2026-10-24 | 0.0h | 7.5h | 15.8h |
| 2026-10-25 | 0.0h | 8.7h | 16.2h |
| 2026-10-26 | 0.0h | 0.9h | 16.5h |