October 27, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

6

Plan writes

3

No-change acknowledgements

2

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:16MIDNIGHTplan_writtenWrote public plan iris-20261027-0016. Resolved 00:20 MDT.
Morning planning cycle07:26SUNRISEplan_writtenWrote public plan iris-20261027-0726. Resolved 07:32 MDT.
Solar peak planning checkpoint12:46SOLAR_MAXackedAcknowledged: No tunable change: live solar 326 W/m² is well above the raw 13:00 forecast 68 (about 21 after the stated +47 bias correction), but indoor VPD is steady at 0.67 kPa inside the current 0.44–0.99 band, RH 77%, dew margin 7.8°F, and mode IDLE. Retrieved guidance favors avoiding preemptive wetting until VPD rises; keep current plan posture and monitor the afternoon. Resolved 12:48 MDT.
Peak Stress14:46TRANSITIONackedAcknowledged: No tunable change: live climate is 78.4°F, VPD 0.92 kPa, dew margin 9.6°F, inside the current dispatcher corridor; no heat/VPD-high stress is evident and cooling/wet equipment is appropriately off. Conditions do not justify an override to the governing plan. Open heap-pressure warning noted; no controller action inferred from it. Resolved 14:47 MDT.
Decline17:05TRANSITIONaction_completedDelivery recorded without a public plan write. Resolved 17:06 MDT.
Evening planning cycle18:05SUNSETplan_writtenWrote public plan iris-20261027-1806. Resolved 18:10 MDT.

🌅 Morning Cycle (12:20 AM) — iris-20261027-0016

Status

validated

Outcome score

3/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261026-1806

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:46.0,“outdoor_rh_min_pct”:90.0,“solar_peak_w_m2”:0.0,“cloud_cover_avg_pct”:65.75,“notes”:“Forecast cloud mean 65.75% for 19:00 Oct 26–06:00 Oct 27; outdoor 46F falling to 42F, RH 90–100%, VPD near zero. House is 74F/VPD 0.49 with 5.4F dew margin. Oct 26 score 66.7, temp 34.6% vs VPD 87.6%; cold stress dominated. Previous plan graded 4 vs anchor 3. Cost, coverage, and physical crop evidence are unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-26T18:06:00-06:00”,“end”:“2026-10-27T06:30:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat; avoid unnecessary outdoor exchange and wetting; retain stable dwell without changing crop bands… Result: Scoped window for iris-20261027-0016 (use its per-plan window scorecard, not yesterday’s daily summary): contract-2 legacy house-average both-axis compliance 0%, temp 0%, VPD 7.2%; nominal cold stress 1.99h and VPD-low stress 1.85h, with heat, VPD-high and dew-risk hours at 0; planner score 34.2. The hypothesis predicted under 1h VPD-low stress and zero new dew-risk through the handoff: dew-risk prediction met, but VPD-low exceeded the target by 0.85h and temperature remained entirely out of band. Cold pressure persisted as expected. This is a short ~7.1h scoped diagnostic window with unverified coverage and no fixed-panel or physical-crop evidence, so no causal attribution. The separate realized solar-night dryout read for Oct 26 had 24 episodes: 0 effective, 11 ineffective, 7 blocked, 6 insufficient-evidence; aggregate safety gate failed, including heat2_forbidden violations. One daytime dry-action sample and zero hold admissions do not prove zero daytime demand or complete coverage. Score: 3/10

Hypothesis

Testing: Cold-saturated overnight handoff: keep wet assist gated by measured band excess and an 8°F dew margin. Expected outcome: Through 10:30 MDT, target <1h VPD-low stress and 0 new dew-risk hours; cold stress may persist. Contract-2 diagnostics only, not crop outcomes.

Setpoints

Tuesday October 27

Primary crop-band changes:

TimeValuesNote
00:16hyst 0.21750000000000003Now: VPD 0.38 is inside the midnight band; 6.1°F dew margin
04:30hyst 0.21750000000000003Pre-dawn 41–42°F and saturated: preserve heat; avoid forecas
07:00hyst 0.21750000000000003Cloudy 41°F dawn: keep heat stable; assist only on measured
10:30hyst 0.21250000000000002Early handoff: retain band-coupled assistance; weather is st

Tactical tunable changes:

TimeValuesNote
00:16s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5333333333333332Now: VPD 0.38 is inside the midnight band; 6.1°F dew margin
04:30s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5333333333333332Pre-dawn 41–42°F and saturated: preserve heat; avoid forecas
07:00s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5666666666666667Cloudy 41°F dawn: keep heat stable; assist only on measured
10:30s2 1.8025000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.6Early handoff: retain band-coupled assistance; weather is st

Changed secondary parameters:

TimeParameterChange
00:16band_track_fractioninitial 0
00:16cold_vent_guard_delta_finitial 10
00:16cool_stage2_exit_hysteresis_finitial 1
00:16direct_wet_stress_min_dew_margin_finitial 8
00:16direct_wet_stress_vpd_margin_kpainitial 0.05
00:16dwell_gate_msinitial 300000
00:16enthalpy_closeinitial 1
00:16enthalpy_openinitial -2
00:16fog_escalation_kpainitial 0.35
00:16heat_hysteresisinitial 1
00:16min_fog_off_sinitial 66
00:16min_fog_on_sinitial 61.5
00:16mist_backoff_sinitial 600
00:16mist_max_closed_vent_sinitial 600
00:16mist_thermal_relief_sinitial 90
00:16mister_all_delay_sinitial 102
00:16mister_engage_delay_sinitial 51
00:16mister_water_budget_galinitial 120
00:16night_vpd_bias_kpainitial 0
00:16outdoor_staleness_max_sinitial 600
00:16sw_dwell_gate_enabledinitial 1
00:16sw_fog_closes_ventinitial 1
00:16sw_mister_closes_ventinitial 0
00:16sw_summer_vent_enabledinitial 1
00:16temp_hysteresisinitial 2.14
00:16vent_exchange_fractioninitial 0.3
00:16vent_prefer_dp_delta_finitial 4
00:16vent_prefer_temp_delta_finitial 6
00:16vpd_watch_dwell_sinitial 75
10:30dwell_gate_ms300000 → 285000
10:30fog_escalation_kpa0.35 → 0.3
10:30mister_all_delay_s102 → 97.5
10:30mister_engage_delay_s51 → 48.75
10:30temp_hysteresis2.14 → 2.05
10:30vpd_watch_dwell_s75 → 71.25

🌅 Morning Cycle (7:32 AM) — iris-20261027-0726

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261027-0016

Previous hypothesis: Prior completed plan iris-20261026-0725 scored 3/10 vs deterministic anchor 2 (gap 1): its 07:29–11:20 MDT window had weak temperature compliance and some VPD-low stress; cold load broadly matched expectation. The Oct 28 dry-ramp prediction is not yet testable. Oct 26 full-day contract-2 score was 60.8, with binary temp/VPD 28.3%/71.4% and 22.47 nominal stress hours (16.07 cold, 5.50 VPD-low); these are historical diagnostics, not crop outcomes. Costs, coverage, fixed-panel and physical-crop evidence are unavailable. Now 62.5°F/0.38 kPa, dew margin 6.1°F, heat1 on; outdoor is 42.9°F/92% RH. Forecast: cloudy 41–43°F dawn, slow rise to 60°F, no meaningful solar until later. Hypothesis: stable heat and an 8°F wet-assist dew-margin floor avoid additional dew-risk/VPD-low escalation through the early-day handoff; retain near-edge wet assist only for measured VPD excess with safe margin… Result: PARTIAL elapsed window only (plan still governed; future Oct 28 waypoints/outcomes not yet testable). Scoped window scorecard: planner_score 58.5; contract-2 legacy house-average both-axis compliance 27.6%, temp 34.9%, VPD 55.7%; nominal stress cold 4.87h, VPD-high 0.56h, VPD-low 2.75h, heat 0h. The VPD-high <3h prediction was met, but the VPD-low <2h/no-overshoot target was not met in the elapsed window. Outdoor peak was 61.5F vs 71F forecast; 699 W/m2 vs 518 forecast, but outdoor conditions are not indoor response. Missing cost, coverage, fixed-panel and physical crop evidence preclude causal claims or durable lessons. Score: 4/10

Hypothesis

Testing: Live-confirmed dry-ramp test: remain conservative through today’s damp/cloudy handoff, then open band-coupled moisture only when measured VPD exceeds the active high edge and dew margin is safe. Expected outcome: Oct 27: <2 additional VPD-low stress hours and 0 dew-risk hours. Oct 28: keep VPD-high stress <3h and avoid VPD-low overshoot; contract-2 diagnostics only, not crop outcomes.

Conditions

Outdoor peak

71.0°F

RH minimum

11.0%

Solar peak

518.0 W/m²

Cloud average

76.946%

MCP hourly cloud mean across Oct 27 08:00-Oct 28 20:00 MDT inclusive (37 values). Oct 27 is cloudy, 43-61F with outdoor VPD peak 1.03; Oct 28 dry ramp reaches 71F, 11% RH, outdoor VPD 2.34 and 518 W/m2. At 07:27 indoor is 63.3F/0.44kPa, RH 78%, dew margin 7F; outdoor forecast is not indoor response.

Expected stress windows

vpd_lowmedium · 2026-10-27T07:26:00-06:00 to 2026-10-27T10:30:00-06:00

Avoid forecast-only wetting; hold an 8F dew-margin floor and rely on live controller demand.

vpd_highhigh · 2026-10-28T11:00:00-06:00 to 2026-10-28T17:00:00-06:00

Allow band-coupled wet assist only on measured indoor VPD-high with dew margin >=8F; retain firmware fog gates.

Parameter rationale

fog_escalation_kpa0.35 → 0.2; Oct 28 outdoor VPD 1.17-2.34kPa, RH 11-35%, 71F and 518W/m2 peak; forecast is outdoor-only.

If indoor VPD exceeds its active high edge and dew margin is >=8F, allow guarded fog; target VPD-high <3h without VPD-low overshoot.

Setpoints

Tuesday October 27

Primary crop-band changes:

TimeValuesNote
07:26hyst 0.20750000000000002Dawn handoff: VPD is low-edge and dew margin 7F; keep wet as
10:30hyst 0.20750000000000002Cloudy morning ramp: avoid adding moisture until live VPD ap

Tactical tunable changes:

TimeValuesNote
07:26s2 1.98; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.208; all 1.358; pulse 30; gap 60; wt 1.3333333333333333Dawn handoff: VPD is low-edge and dew margin 7F; keep wet as
10:30s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.158; all 1.308; pulse 30; gap 56.25; wt 1.4Cloudy morning ramp: avoid adding moisture until live VPD ap

Wednesday October 28

Primary crop-band changes:

TimeValuesNote
10:30hyst 0.20750000000000002Dry-ramp lead: enable assist only at measured indoor edge de
17:00hyst 0.20750000000000002After peak, retain guarded recovery while observed indoor VP
20:00hyst 0.20750000000000002Evening recovery: cap wetting at 19:00 and stop if measured

Tactical tunable changes:

TimeValuesNote
10:30s2 1.875; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9580000000000001; all 1.158; pulse 37.5; gap 33.75; wt 1.7000000000000002Dry-ramp lead: enable assist only at measured indoor edge de
17:00s2 1.8900000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9580000000000001; all 1.158; pulse 33.75; gap 37.5; wt 1.6333333333333333After peak, retain guarded recovery while observed indoor VP
20:00s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9580000000000001; all 1.158; pulse 30; gap 56.25; wt 1.3666666666666667Evening recovery: cap wetting at 19:00 and stop if measured

Changed secondary parameters:

TimeParameterChange
07:26band_track_fractioninitial 0
07:26cold_vent_guard_delta_finitial 8
07:26cool_stage2_exit_hysteresis_finitial 1
07:26direct_wet_stress_min_dew_margin_finitial 8
07:26direct_wet_stress_vpd_margin_kpainitial 0.3
07:26dwell_gate_msinitial 270000
07:26enthalpy_closeinitial 1
07:26enthalpy_openinitial -2
07:26fog_escalation_kpainitial 0.4
07:26heat_hysteresisinitial 1
07:26min_fog_off_sinitial 102
07:26min_fog_on_sinitial 48
07:26mist_backoff_sinitial 600
07:26mist_max_closed_vent_sinitial 600
07:26mist_thermal_relief_sinitial 90
07:26mister_all_delay_sinitial 93
07:26mister_engage_delay_sinitial 46.5
07:26mister_water_budget_galinitial 120
07:26night_vpd_bias_kpainitial 0
07:26outdoor_staleness_max_sinitial 600
07:26sw_dwell_gate_enabledinitial 1
07:26sw_fog_closes_ventinitial 1
07:26sw_mister_closes_ventinitial 0
07:26sw_summer_vent_enabledinitial 1
07:26temp_hysteresisinitial 1.96
07:26vent_exchange_fractioninitial 0.3
07:26vent_prefer_dp_delta_finitial 3
07:26vent_prefer_temp_delta_finitial 4
07:26vpd_watch_dwell_sinitial 67.5
10:30direct_wet_stress_vpd_margin_kpa0.3 → 0.25
10:30fog_escalation_kpa0.4 → 0.35
10:30min_fog_off_s102 → 96
10:30min_fog_on_s48 → 50.25
10:30direct_wet_stress_vpd_margin_kpa0.25 → 0.05
10:30fog_escalation_kpa0.35 → 0.2
10:30min_fog_off_s96 → 60
10:30min_fog_on_s50.25 → 63.75
17:00min_fog_off_s60 → 66
17:00min_fog_on_s63.75 → 61.5
20:00fog_escalation_kpa0.2 → 0.35
20:00min_fog_off_s66 → 96
20:00min_fog_on_s61.5 → 50.25

🌆 Evening Cycle (6:10 PM) — iris-20261027-1806

Status

validated

Outcome score

6/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261027-0726

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:71.0,“outdoor_rh_min_pct”:11.0,“solar_peak_w_m2”:518,“cloud_cover_avg_pct”:76.946,“notes”:“MCP hourly cloud mean across Oct 27 08:00-Oct 28 20:00 MDT inclusive (37 values). Oct 27 is cloudy, 43-61F with outdoor VPD peak 1.03; Oct 28 dry ramp reaches 71F, 11% RH, outdoor VPD 2.34 and 518 W/m2. At 07:27 indoor is 63.3F/0.44kPa, RH 78%, dew margin 7F; outdoor forecast is not indoor response.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-10-27T07:26:00-06:00”,“end”:“2026-10-27T10:30:00-06:00”,“severity”:“medium”,“mitigation”:“Avoid forecast-only wetting; hold an 8F dew-margin floor and rely on live controller demand.”},{“kind”:“vpd_high”,“start”:“2026-10-28T11:00:00-06:00”,“end”:“2026-10-28T17:00:00-06:00”,“severity”:“high”,“mitigation”:“Allow band-coupled wet assist only on measured indoor VPD-high with dew margin >=8F; retain firmware fog gates… Result: Scoped plan window 2026-10-27 18:10–2026-10-28 00:23 only: contract-2 planner_score 61.3; legacy house-average both-axis/temp compliance 0%/0%, VPD 77.5%; nominal stress cold 1.76h, VPD-high 0h, VPD-low 0.40h, dew-risk 0h. Hypothesis predicted overnight cold load and VPD-low risk; within this shorter window cold occurred and VPD-low stayed below 3h, while dew-risk stayed below 1h. This supports the limited scoped predictions, but the full overnight window was not included, costs/coverage/fixed-panel/crop outcomes unavailable, and daily 483 gal water + 3.1h dew risk cannot be attributed solely to this plan. No causal lesson; no episodes in the Oct 27 realized solar-night dryout read is not evidence of zero daytime admission or effectiveness. Score: 6/10

Hypothesis

Testing: Cold-humid overnight hold; assess the scoped night scorecard and relay stability at the next cycle. Expected outcome: For Oct 27 18:06–Oct 28 05:00 MDT, target VPD-low stress <3h, dew-risk <1h, and fewer heat/vent reversals; contract-2 diagnostics only, not crop outcomes.

Conditions

Outdoor peak

50.0°F

RH minimum

58.0%

Solar peak

0.0 W/m²

Cloud average

46.917%

Forecast Oct 27 19:00–Oct 28 06:00 MDT: 50F falling to 37F, RH 58–83%, no solar. Indoor 72.6F/VPD 0.65/dew margin 7.9F; heat1 on. Partial Oct 27 score 59, temp 35.2%, VPD 56.1%; cold stress 11.18h and VPD-low 6.30h. Costs unavailable; outdoor forecast is not indoor response.

Expected stress windows

coldhigh · 2026-10-27T22:00:00-06:00 to 2026-10-28T06:00:00-06:00

Preserve heat; require clear temperature/dewpoint advantage before exchange; penalize relay churn.

vpd_lowmedium · 2026-10-27T23:00:00-06:00 to 2026-10-28T05:30:00-06:00

Keep wet duty limited but available; hold an 8.5F dew-margin floor and follow live demand.

Parameter rationale

mister_engage_kpa0.889 → 1.09; Indoor VPD 0.65 is below the active 0.99 high edge; dew margin 7.9F is below the planned 8.5F floor, with 37F dawn forecast.

Require measured VPD > high+0.10 and a safe dew margin before wet assist; target overnight VPD-low <3h and dew-risk <1h.

Setpoints

Tuesday October 27

Primary crop-band changes:

TimeValuesNote
18:06hyst 0.2175evening_settle: cold outdoor air; hold heat and limit wettin

Tactical tunable changes:

TimeValuesNote
18:06s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.5evening_settle: cold outdoor air; hold heat and limit wettin

Wednesday October 28

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.22249999999999998midnight_posture: low outdoor VPD and high RH favor heat ret
05:00hyst 0.22249999999999998pre_dawn: forecast low 37F; preserve heat, avoid unnecessary

Tactical tunable changes:

TimeValuesNote
00:00s2 1.92; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.48midnight_posture: low outdoor VPD and high RH favor heat ret
05:00s2 1.92; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.5pre_dawn: forecast low 37F; preserve heat, avoid unnecessary

Changed secondary parameters:

TimeParameterChange
18:06band_track_fractioninitial 0
18:06cold_vent_guard_delta_finitial 12
18:06cool_stage2_exit_hysteresis_finitial 1
18:06direct_wet_stress_min_dew_margin_finitial 8.5
18:06direct_wet_stress_vpd_margin_kpainitial 0.1
18:06dwell_gate_msinitial 300000
18:06enthalpy_closeinitial 1
18:06enthalpy_openinitial -2
18:06fog_escalation_kpainitial 0.45
18:06heat_hysteresisinitial 1
18:06min_fog_off_sinitial 78
18:06min_fog_on_sinitial 57
18:06mist_backoff_sinitial 600
18:06mist_max_closed_vent_sinitial 600
18:06mist_thermal_relief_sinitial 90
18:06mister_all_delay_sinitial 102
18:06mister_engage_delay_sinitial 51
18:06mister_water_budget_galinitial 120
18:06night_vpd_bias_kpainitial 0
18:06outdoor_staleness_max_sinitial 600
18:06sw_dwell_gate_enabledinitial 1
18:06sw_fog_closes_ventinitial 1
18:06sw_mister_closes_ventinitial 0
18:06sw_summer_vent_enabledinitial 1
18:06temp_hysteresisinitial 2.14
18:06vent_exchange_fractioninitial 0.3
18:06vent_prefer_dp_delta_finitial 5
18:06vent_prefer_temp_delta_finitial 8
18:06vpd_watch_dwell_sinitial 75
00:00cold_vent_guard_delta_f12 → 14
00:00dwell_gate_ms300000 → 315000
00:00mister_all_delay_s102 → 106.5
00:00mister_engage_delay_s51 → 53.25
00:00temp_hysteresis2.14 → 2.23
00:00vent_prefer_dp_delta_f5 → 6
00:00vent_prefer_temp_delta_f8 → 10
00:00vpd_watch_dwell_s75 → 78.75

End-of-Day Summary

Climate

Temperature

59.1–83.0°F; avg 68.6°F

VPD

0.24–1.14 kPa; avg 0.58 kPa

Relative humidity

68.3–86.8%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: legacy_invalid_exterior_proxy_plus_fixture_estimate
  • Validity: dli-validity-v1; 2024-01-01T00:00:00+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (>85°F): 0.0h
  • VPD stress (>2.0 kPa): 1.3h
  • Cold stress (<55°F): 16.6h

Economics

Electric

Not available

Gas

USD 1.32

Water

USD 2.340

Total

Not available

Equipment Runtimes

EquipmentRuntimeReading
Fan 18 minPrimary exhaust runtime.
Fan 216 minSecondary exhaust runtime.
Vent24 minIntake vent runtime.
Fog0 minFogger runtime.
Heat 1 electric1217 minElectric heater runtime.
Heat 2 gas127 minGas heater runtime.
Grow lights1438 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center0.00hCenter mister runtime.

Water

  • Total: 483 gal
  • Mister: 0 gal

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Lime Treewest66%9Observation notes are collapsed below to avoid publishing partial vision snippets.
Vanda Orchidscenter68%4Observation notes are collapsed below to avoid publishing partial vision snippets.
peppereast58%5Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
Lime TreeGemini Vision notes

Plant appears healthy with vibrant green foliage, though specific identification as a Lime Tree is difficult from this distance. || Vegetative growth visible on the left-side shelving. Foliage appears dense and healthy. No obvious signs of nutrient deficiency or pest damage. || [high humidity] Vegetative growth observed in the west zone. The plant appears structurally sound, but the high relative humidity (85.5%) and low VPD (0.29 kPa) may limit transpiration and nutrient uptake. || [leaf browning] Large potted tree on the left (west). Some lower leaves appear brown and dry, likely due to the low humidity or inconsistent watering. || [leaf drop] The tree in the blue pot on the left (west) has sparse foliage with visible brown/dry leaves on the lower branches. The unavailable' soil moisture reading indicates a sensor issue or dryness. || [potential nutrient deficiency] Vegetative growth is visible on the left-side shelving. The 0.0% soil moisture reading for the South zone (likely associated

Vanda OrchidsGemini Vision notes

[low light exposure] Hanging in the center zone, roots are visible and appear intact. The 0 lux reading suggests lights are off (night cycle), which is normal, but the plants appear somewhat sparse. || [low light, high humidity] Hanging baskets visible in center. Roots appear exposed. 0 lux light level is suboptimal for active growth, though typical for night cycle. High humidity (85.5%) is suitable for Vanda but requires monitoring for fungal issues. || [root exposure] Hanging baskets visible in the center zone. Roots appear dry and exposed, which is typical for Vanda but requires monitoring given the 0.98 kPa VPD. || [root exposure] Hanging orchids visible in the center. Roots are exposed and appear somewhat pale/dry, which is typical for Vandas but requires monitoring given the 0% soil moisture reading in the south zone.

pepperGemini Vision notes

Seedlings visible on the right-side shelving units. Plants appear upright and turgid. No visible wilting or leaf drop. || [high humidity, low light] Seedlings visible on shelving units in the east zone. Plants appear upright but are subject to high humidity (85.5%) and low light (0 lux), which may inhibit growth and increase disease risk. || [low light exposure] Seedlings appear upright but are in a dark environment (0 lux) which limits photosynthesis. Located on the right-side shelving units. || [wilting, exposed roots] Seedling appears to be out of its pot with roots exposed to air, likely causing stress and wilting. || [wilting, nutrient deficiency] Visible in the bottom right corner. Leaves show significant yellowing and browning at the tips, indicating stress. The plant appears to be struggling, possibly due to the reported 0.0% soil moisture in the south zone (which may be adjacent or related to this area) or general nutrient issues.

Hourly Pattern

HourTemperatureVPDRH
12:0074.9°F0.47 kPa84.5%
13:0078.4°F0.45 kPa86.6%
14:0077.0°F0.59 kPa81.7%
15:0079.1°F0.73 kPa79.0%
16:0078.2°F0.57 kPa82.8%
17:0074.4°F0.46 kPa84.3%
18:0072.7°F0.44 kPa84.0%
19:0070.8°F0.42 kPa83.9%
20:0068.9°F0.39 kPa84.0%
21:0067.3°F0.37 kPa83.9%
22:0066.2°F0.34 kPa84.7%
23:0064.5°F0.34 kPa83.5%
00:0062.8°F0.31 kPa84.5%
01:0060.9°F0.31 kPa83.4%
02:0060.7°F0.27 kPa85.1%
03:0060.3°F0.27 kPa84.9%
04:0061.7°F0.37 kPa80.8%
05:0061.5°F0.37 kPa80.5%
06:0062.6°F0.42 kPa78.4%
07:0064.4°F0.50 kPa75.9%
08:0066.3°F0.58 kPa73.9%
09:0068.4°F0.68 kPa71.6%
10:0071.2°F0.68 kPa74.0%
11:0073.1°F0.59 kPa79.0%

7-Day Stress Context

DateHeatVPD highCold
2026-10-210.0h8.4h14.7h
2026-10-220.0h7.3h14.9h
2026-10-230.5h6.5h14.7h
2026-10-240.0h7.5h15.8h
2026-10-250.0h8.7h16.2h
2026-10-260.0h0.9h16.5h
2026-10-270.0h1.3h16.6h