October 27, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
6
3
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261027-0016. Resolved 00:20 MDT. |
| Morning planning cycle | 07:26 | SUNRISE | plan_written | Wrote public plan iris-20261027-0726. Resolved 07:32 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | acked | Acknowledged: No tunable change: live solar 326 W/m² is well above the raw 13:00 forecast 68 (about 21 after the stated +47 bias correction), but indoor VPD is steady at 0.67 kPa inside the current 0.44–0.99 band, RH 77%, dew margin 7.8°F, and mode IDLE. Retrieved guidance favors avoiding preemptive wetting until VPD rises; keep current plan posture and monitor the afternoon. Resolved 12:48 MDT. |
| Peak Stress | 14:46 | TRANSITION | acked | Acknowledged: No tunable change: live climate is 78.4°F, VPD 0.92 kPa, dew margin 9.6°F, inside the current dispatcher corridor; no heat/VPD-high stress is evident and cooling/wet equipment is appropriately off. Conditions do not justify an override to the governing plan. Open heap-pressure warning noted; no controller action inferred from it. Resolved 14:47 MDT. |
| Decline | 17:05 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 17:06 MDT. |
| Evening planning cycle | 18:05 | SUNSET | plan_written | Wrote public plan iris-20261027-1806. Resolved 18:10 MDT. |
🌅 Morning Cycle (12:20 AM) — iris-20261027-0016
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261026-1806
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:46.0,“outdoor_rh_min_pct”:90.0,“solar_peak_w_m2”:0.0,“cloud_cover_avg_pct”:65.75,“notes”:“Forecast cloud mean 65.75% for 19:00 Oct 26–06:00 Oct 27; outdoor 46F falling to 42F, RH 90–100%, VPD near zero. House is 74F/VPD 0.49 with 5.4F dew margin. Oct 26 score 66.7, temp 34.6% vs VPD 87.6%; cold stress dominated. Previous plan graded 4 vs anchor 3. Cost, coverage, and physical crop evidence are unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-26T18:06:00-06:00”,“end”:“2026-10-27T06:30:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat; avoid unnecessary outdoor exchange and wetting; retain stable dwell without changing crop bands… Result: Scoped window for iris-20261027-0016 (use its per-plan window scorecard, not yesterday’s daily summary): contract-2 legacy house-average both-axis compliance 0%, temp 0%, VPD 7.2%; nominal cold stress 1.99h and VPD-low stress 1.85h, with heat, VPD-high and dew-risk hours at 0; planner score 34.2. The hypothesis predicted under 1h VPD-low stress and zero new dew-risk through the handoff: dew-risk prediction met, but VPD-low exceeded the target by 0.85h and temperature remained entirely out of band. Cold pressure persisted as expected. This is a short ~7.1h scoped diagnostic window with unverified coverage and no fixed-panel or physical-crop evidence, so no causal attribution. The separate realized solar-night dryout read for Oct 26 had 24 episodes: 0 effective, 11 ineffective, 7 blocked, 6 insufficient-evidence; aggregate safety gate failed, including heat2_forbidden violations. One daytime dry-action sample and zero hold admissions do not prove zero daytime demand or complete coverage. Score: 3/10
Hypothesis
Testing: Cold-saturated overnight handoff: keep wet assist gated by measured band excess and an 8°F dew margin. Expected outcome: Through 10:30 MDT, target <1h VPD-low stress and 0 new dew-risk hours; cold stress may persist. Contract-2 diagnostics only, not crop outcomes.
Setpoints
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21750000000000003 | Now: VPD 0.38 is inside the midnight band; 6.1°F dew margin |
| 04:30 | hyst 0.21750000000000003 | Pre-dawn 41–42°F and saturated: preserve heat; avoid forecas |
| 07:00 | hyst 0.21750000000000003 | Cloudy 41°F dawn: keep heat stable; assist only on measured |
| 10:30 | hyst 0.21250000000000002 | Early handoff: retain band-coupled assistance; weather is st |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5333333333333332 | Now: VPD 0.38 is inside the midnight band; 6.1°F dew margin |
| 04:30 | s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5333333333333332 | Pre-dawn 41–42°F and saturated: preserve heat; avoid forecas |
| 07:00 | s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.5666666666666667 | Cloudy 41°F dawn: keep heat stable; assist only on measured |
| 10:30 | s2 1.8025000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 37.5; wt 1.6 | Early handoff: retain band-coupled assistance; weather is st |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 10 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 300000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.35 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 66 |
| 00:16 | min_fog_on_s | initial 61.5 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 102 |
| 00:16 | mister_engage_delay_s | initial 51 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.14 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 4 |
| 00:16 | vent_prefer_temp_delta_f | initial 6 |
| 00:16 | vpd_watch_dwell_s | initial 75 |
| 10:30 | dwell_gate_ms | 300000 → 285000 |
| 10:30 | fog_escalation_kpa | 0.35 → 0.3 |
| 10:30 | mister_all_delay_s | 102 → 97.5 |
| 10:30 | mister_engage_delay_s | 51 → 48.75 |
| 10:30 | temp_hysteresis | 2.14 → 2.05 |
| 10:30 | vpd_watch_dwell_s | 75 → 71.25 |
🌅 Morning Cycle (7:32 AM) — iris-20261027-0726
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261027-0016
Previous hypothesis: Prior completed plan iris-20261026-0725 scored 3/10 vs deterministic anchor 2 (gap 1): its 07:29–11:20 MDT window had weak temperature compliance and some VPD-low stress; cold load broadly matched expectation. The Oct 28 dry-ramp prediction is not yet testable. Oct 26 full-day contract-2 score was 60.8, with binary temp/VPD 28.3%/71.4% and 22.47 nominal stress hours (16.07 cold, 5.50 VPD-low); these are historical diagnostics, not crop outcomes. Costs, coverage, fixed-panel and physical-crop evidence are unavailable. Now 62.5°F/0.38 kPa, dew margin 6.1°F, heat1 on; outdoor is 42.9°F/92% RH. Forecast: cloudy 41–43°F dawn, slow rise to 60°F, no meaningful solar until later. Hypothesis: stable heat and an 8°F wet-assist dew-margin floor avoid additional dew-risk/VPD-low escalation through the early-day handoff; retain near-edge wet assist only for measured VPD excess with safe margin… Result: PARTIAL elapsed window only (plan still governed; future Oct 28 waypoints/outcomes not yet testable). Scoped window scorecard: planner_score 58.5; contract-2 legacy house-average both-axis compliance 27.6%, temp 34.9%, VPD 55.7%; nominal stress cold 4.87h, VPD-high 0.56h, VPD-low 2.75h, heat 0h. The VPD-high <3h prediction was met, but the VPD-low <2h/no-overshoot target was not met in the elapsed window. Outdoor peak was 61.5F vs 71F forecast; 699 W/m2 vs 518 forecast, but outdoor conditions are not indoor response. Missing cost, coverage, fixed-panel and physical crop evidence preclude causal claims or durable lessons. Score: 4/10
Hypothesis
Testing: Live-confirmed dry-ramp test: remain conservative through today’s damp/cloudy handoff, then open band-coupled moisture only when measured VPD exceeds the active high edge and dew margin is safe. Expected outcome: Oct 27: <2 additional VPD-low stress hours and 0 dew-risk hours. Oct 28: keep VPD-high stress <3h and avoid VPD-low overshoot; contract-2 diagnostics only, not crop outcomes.
Conditions
71.0°F
11.0%
518.0 W/m²
76.946%
MCP hourly cloud mean across Oct 27 08:00-Oct 28 20:00 MDT inclusive (37 values). Oct 27 is cloudy, 43-61F with outdoor VPD peak 1.03; Oct 28 dry ramp reaches 71F, 11% RH, outdoor VPD 2.34 and 518 W/m2. At 07:27 indoor is 63.3F/0.44kPa, RH 78%, dew margin 7F; outdoor forecast is not indoor response.
Expected stress windows
Avoid forecast-only wetting; hold an 8F dew-margin floor and rely on live controller demand.
Allow band-coupled wet assist only on measured indoor VPD-high with dew margin >=8F; retain firmware fog gates.
Parameter rationale
If indoor VPD exceeds its active high edge and dew margin is >=8F, allow guarded fog; target VPD-high <3h without VPD-low overshoot.
Setpoints
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:26 | hyst 0.20750000000000002 | Dawn handoff: VPD is low-edge and dew margin 7F; keep wet as |
| 10:30 | hyst 0.20750000000000002 | Cloudy morning ramp: avoid adding moisture until live VPD ap |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:26 | s2 1.98; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.208; all 1.358; pulse 30; gap 60; wt 1.3333333333333333 | Dawn handoff: VPD is low-edge and dew margin 7F; keep wet as |
| 10:30 | s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.158; all 1.308; pulse 30; gap 56.25; wt 1.4 | Cloudy morning ramp: avoid adding moisture until live VPD ap |
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:30 | hyst 0.20750000000000002 | Dry-ramp lead: enable assist only at measured indoor edge de |
| 17:00 | hyst 0.20750000000000002 | After peak, retain guarded recovery while observed indoor VP |
| 20:00 | hyst 0.20750000000000002 | Evening recovery: cap wetting at 19:00 and stop if measured |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:30 | s2 1.875; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9580000000000001; all 1.158; pulse 37.5; gap 33.75; wt 1.7000000000000002 | Dry-ramp lead: enable assist only at measured indoor edge de |
| 17:00 | s2 1.8900000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9580000000000001; all 1.158; pulse 33.75; gap 37.5; wt 1.6333333333333333 | After peak, retain guarded recovery while observed indoor VP |
| 20:00 | s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9580000000000001; all 1.158; pulse 30; gap 56.25; wt 1.3666666666666667 | Evening recovery: cap wetting at 19:00 and stop if measured |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:26 | band_track_fraction | initial 0 |
| 07:26 | cold_vent_guard_delta_f | initial 8 |
| 07:26 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:26 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:26 | direct_wet_stress_vpd_margin_kpa | initial 0.3 |
| 07:26 | dwell_gate_ms | initial 270000 |
| 07:26 | enthalpy_close | initial 1 |
| 07:26 | enthalpy_open | initial -2 |
| 07:26 | fog_escalation_kpa | initial 0.4 |
| 07:26 | heat_hysteresis | initial 1 |
| 07:26 | min_fog_off_s | initial 102 |
| 07:26 | min_fog_on_s | initial 48 |
| 07:26 | mist_backoff_s | initial 600 |
| 07:26 | mist_max_closed_vent_s | initial 600 |
| 07:26 | mist_thermal_relief_s | initial 90 |
| 07:26 | mister_all_delay_s | initial 93 |
| 07:26 | mister_engage_delay_s | initial 46.5 |
| 07:26 | mister_water_budget_gal | initial 120 |
| 07:26 | night_vpd_bias_kpa | initial 0 |
| 07:26 | outdoor_staleness_max_s | initial 600 |
| 07:26 | sw_dwell_gate_enabled | initial 1 |
| 07:26 | sw_fog_closes_vent | initial 1 |
| 07:26 | sw_mister_closes_vent | initial 0 |
| 07:26 | sw_summer_vent_enabled | initial 1 |
| 07:26 | temp_hysteresis | initial 1.96 |
| 07:26 | vent_exchange_fraction | initial 0.3 |
| 07:26 | vent_prefer_dp_delta_f | initial 3 |
| 07:26 | vent_prefer_temp_delta_f | initial 4 |
| 07:26 | vpd_watch_dwell_s | initial 67.5 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.3 → 0.25 |
| 10:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 10:30 | min_fog_off_s | 102 → 96 |
| 10:30 | min_fog_on_s | 48 → 50.25 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 10:30 | fog_escalation_kpa | 0.35 → 0.2 |
| 10:30 | min_fog_off_s | 96 → 60 |
| 10:30 | min_fog_on_s | 50.25 → 63.75 |
| 17:00 | min_fog_off_s | 60 → 66 |
| 17:00 | min_fog_on_s | 63.75 → 61.5 |
| 20:00 | fog_escalation_kpa | 0.2 → 0.35 |
| 20:00 | min_fog_off_s | 66 → 96 |
| 20:00 | min_fog_on_s | 61.5 → 50.25 |
🌆 Evening Cycle (6:10 PM) — iris-20261027-1806
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261027-0726
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:71.0,“outdoor_rh_min_pct”:11.0,“solar_peak_w_m2”:518,“cloud_cover_avg_pct”:76.946,“notes”:“MCP hourly cloud mean across Oct 27 08:00-Oct 28 20:00 MDT inclusive (37 values). Oct 27 is cloudy, 43-61F with outdoor VPD peak 1.03; Oct 28 dry ramp reaches 71F, 11% RH, outdoor VPD 2.34 and 518 W/m2. At 07:27 indoor is 63.3F/0.44kPa, RH 78%, dew margin 7F; outdoor forecast is not indoor response.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-10-27T07:26:00-06:00”,“end”:“2026-10-27T10:30:00-06:00”,“severity”:“medium”,“mitigation”:“Avoid forecast-only wetting; hold an 8F dew-margin floor and rely on live controller demand.”},{“kind”:“vpd_high”,“start”:“2026-10-28T11:00:00-06:00”,“end”:“2026-10-28T17:00:00-06:00”,“severity”:“high”,“mitigation”:“Allow band-coupled wet assist only on measured indoor VPD-high with dew margin >=8F; retain firmware fog gates… Result: Scoped plan window 2026-10-27 18:10–2026-10-28 00:23 only: contract-2 planner_score 61.3; legacy house-average both-axis/temp compliance 0%/0%, VPD 77.5%; nominal stress cold 1.76h, VPD-high 0h, VPD-low 0.40h, dew-risk 0h. Hypothesis predicted overnight cold load and VPD-low risk; within this shorter window cold occurred and VPD-low stayed below 3h, while dew-risk stayed below 1h. This supports the limited scoped predictions, but the full overnight window was not included, costs/coverage/fixed-panel/crop outcomes unavailable, and daily 483 gal water + 3.1h dew risk cannot be attributed solely to this plan. No causal lesson; no episodes in the Oct 27 realized solar-night dryout read is not evidence of zero daytime admission or effectiveness. Score: 6/10
Hypothesis
Testing: Cold-humid overnight hold; assess the scoped night scorecard and relay stability at the next cycle. Expected outcome: For Oct 27 18:06–Oct 28 05:00 MDT, target VPD-low stress <3h, dew-risk <1h, and fewer heat/vent reversals; contract-2 diagnostics only, not crop outcomes.
Conditions
50.0°F
58.0%
0.0 W/m²
46.917%
Forecast Oct 27 19:00–Oct 28 06:00 MDT: 50F falling to 37F, RH 58–83%, no solar. Indoor 72.6F/VPD 0.65/dew margin 7.9F; heat1 on. Partial Oct 27 score 59, temp 35.2%, VPD 56.1%; cold stress 11.18h and VPD-low 6.30h. Costs unavailable; outdoor forecast is not indoor response.
Expected stress windows
Preserve heat; require clear temperature/dewpoint advantage before exchange; penalize relay churn.
Keep wet duty limited but available; hold an 8.5F dew-margin floor and follow live demand.
Parameter rationale
Require measured VPD > high+0.10 and a safe dew margin before wet assist; target overnight VPD-low <3h and dew-risk <1h.
Setpoints
Tuesday October 27
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:06 | hyst 0.2175 | evening_settle: cold outdoor air; hold heat and limit wettin |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:06 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.5 | evening_settle: cold outdoor air; hold heat and limit wettin |
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.22249999999999998 | midnight_posture: low outdoor VPD and high RH favor heat ret |
| 05:00 | hyst 0.22249999999999998 | pre_dawn: forecast low 37F; preserve heat, avoid unnecessary |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.92; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.48 | midnight_posture: low outdoor VPD and high RH favor heat ret |
| 05:00 | s2 1.92; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.045; all 1.2449999999999999; pulse 30; gap 45; wt 1.5 | pre_dawn: forecast low 37F; preserve heat, avoid unnecessary |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:06 | band_track_fraction | initial 0 |
| 18:06 | cold_vent_guard_delta_f | initial 12 |
| 18:06 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:06 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 18:06 | direct_wet_stress_vpd_margin_kpa | initial 0.1 |
| 18:06 | dwell_gate_ms | initial 300000 |
| 18:06 | enthalpy_close | initial 1 |
| 18:06 | enthalpy_open | initial -2 |
| 18:06 | fog_escalation_kpa | initial 0.45 |
| 18:06 | heat_hysteresis | initial 1 |
| 18:06 | min_fog_off_s | initial 78 |
| 18:06 | min_fog_on_s | initial 57 |
| 18:06 | mist_backoff_s | initial 600 |
| 18:06 | mist_max_closed_vent_s | initial 600 |
| 18:06 | mist_thermal_relief_s | initial 90 |
| 18:06 | mister_all_delay_s | initial 102 |
| 18:06 | mister_engage_delay_s | initial 51 |
| 18:06 | mister_water_budget_gal | initial 120 |
| 18:06 | night_vpd_bias_kpa | initial 0 |
| 18:06 | outdoor_staleness_max_s | initial 600 |
| 18:06 | sw_dwell_gate_enabled | initial 1 |
| 18:06 | sw_fog_closes_vent | initial 1 |
| 18:06 | sw_mister_closes_vent | initial 0 |
| 18:06 | sw_summer_vent_enabled | initial 1 |
| 18:06 | temp_hysteresis | initial 2.14 |
| 18:06 | vent_exchange_fraction | initial 0.3 |
| 18:06 | vent_prefer_dp_delta_f | initial 5 |
| 18:06 | vent_prefer_temp_delta_f | initial 8 |
| 18:06 | vpd_watch_dwell_s | initial 75 |
| 00:00 | cold_vent_guard_delta_f | 12 → 14 |
| 00:00 | dwell_gate_ms | 300000 → 315000 |
| 00:00 | mister_all_delay_s | 102 → 106.5 |
| 00:00 | mister_engage_delay_s | 51 → 53.25 |
| 00:00 | temp_hysteresis | 2.14 → 2.23 |
| 00:00 | vent_prefer_dp_delta_f | 5 → 6 |
| 00:00 | vent_prefer_temp_delta_f | 8 → 10 |
| 00:00 | vpd_watch_dwell_s | 75 → 78.75 |
End-of-Day Summary
Climate
59.1–83.0°F; avg 68.6°F
0.24–1.14 kPa; avg 0.58 kPa
68.3–86.8%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 1.3h
- Cold stress (<55°F): 16.6h
Economics
Not available
USD 1.32
USD 2.340
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 8 min | Primary exhaust runtime. |
| Fan 2 | 16 min | Secondary exhaust runtime. |
| Vent | 24 min | Intake vent runtime. |
| Fog | 0 min | Fogger runtime. |
| Heat 1 electric | 1217 min | Electric heater runtime. |
| Heat 2 gas | 127 min | Gas heater runtime. |
| Grow lights | 1438 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 483 gal
- Mister: 0 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 66% | 9 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 68% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 58% | 5 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Plant appears healthy with vibrant green foliage, though specific identification as a Lime Tree is difficult from this distance. || Vegetative growth visible on the left-side shelving. Foliage appears dense and healthy. No obvious signs of nutrient deficiency or pest damage. || [high humidity] Vegetative growth observed in the west zone. The plant appears structurally sound, but the high relative humidity (85.5%) and low VPD (0.29 kPa) may limit transpiration and nutrient uptake. || [leaf browning] Large potted tree on the left (west). Some lower leaves appear brown and dry, likely due to the low humidity or inconsistent watering. || [leaf drop] The tree in the blue pot on the left (west) has sparse foliage with visible brown/dry leaves on the lower branches. The unavailable' soil moisture reading indicates a sensor issue or dryness. || [potential nutrient deficiency] Vegetative growth is visible on the left-side shelving. The 0.0% soil moisture reading for the South zone (likely associated
[low light exposure] Hanging in the center zone, roots are visible and appear intact. The 0 lux reading suggests lights are off (night cycle), which is normal, but the plants appear somewhat sparse. || [low light, high humidity] Hanging baskets visible in center. Roots appear exposed. 0 lux light level is suboptimal for active growth, though typical for night cycle. High humidity (85.5%) is suitable for Vanda but requires monitoring for fungal issues. || [root exposure] Hanging baskets visible in the center zone. Roots appear dry and exposed, which is typical for Vanda but requires monitoring given the 0.98 kPa VPD. || [root exposure] Hanging orchids visible in the center. Roots are exposed and appear somewhat pale/dry, which is typical for Vandas but requires monitoring given the 0% soil moisture reading in the south zone.
Seedlings visible on the right-side shelving units. Plants appear upright and turgid. No visible wilting or leaf drop. || [high humidity, low light] Seedlings visible on shelving units in the east zone. Plants appear upright but are subject to high humidity (85.5%) and low light (0 lux), which may inhibit growth and increase disease risk. || [low light exposure] Seedlings appear upright but are in a dark environment (0 lux) which limits photosynthesis. Located on the right-side shelving units. || [wilting, exposed roots] Seedling appears to be out of its pot with roots exposed to air, likely causing stress and wilting. || [wilting, nutrient deficiency] Visible in the bottom right corner. Leaves show significant yellowing and browning at the tips, indicating stress. The plant appears to be struggling, possibly due to the reported 0.0% soil moisture in the south zone (which may be adjacent or related to this area) or general nutrient issues.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 74.9°F | 0.47 kPa | 84.5% |
| 13:00 | 78.4°F | 0.45 kPa | 86.6% |
| 14:00 | 77.0°F | 0.59 kPa | 81.7% |
| 15:00 | 79.1°F | 0.73 kPa | 79.0% |
| 16:00 | 78.2°F | 0.57 kPa | 82.8% |
| 17:00 | 74.4°F | 0.46 kPa | 84.3% |
| 18:00 | 72.7°F | 0.44 kPa | 84.0% |
| 19:00 | 70.8°F | 0.42 kPa | 83.9% |
| 20:00 | 68.9°F | 0.39 kPa | 84.0% |
| 21:00 | 67.3°F | 0.37 kPa | 83.9% |
| 22:00 | 66.2°F | 0.34 kPa | 84.7% |
| 23:00 | 64.5°F | 0.34 kPa | 83.5% |
| 00:00 | 62.8°F | 0.31 kPa | 84.5% |
| 01:00 | 60.9°F | 0.31 kPa | 83.4% |
| 02:00 | 60.7°F | 0.27 kPa | 85.1% |
| 03:00 | 60.3°F | 0.27 kPa | 84.9% |
| 04:00 | 61.7°F | 0.37 kPa | 80.8% |
| 05:00 | 61.5°F | 0.37 kPa | 80.5% |
| 06:00 | 62.6°F | 0.42 kPa | 78.4% |
| 07:00 | 64.4°F | 0.50 kPa | 75.9% |
| 08:00 | 66.3°F | 0.58 kPa | 73.9% |
| 09:00 | 68.4°F | 0.68 kPa | 71.6% |
| 10:00 | 71.2°F | 0.68 kPa | 74.0% |
| 11:00 | 73.1°F | 0.59 kPa | 79.0% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-21 | 0.0h | 8.4h | 14.7h |
| 2026-10-22 | 0.0h | 7.3h | 14.9h |
| 2026-10-23 | 0.5h | 6.5h | 14.7h |
| 2026-10-24 | 0.0h | 7.5h | 15.8h |
| 2026-10-25 | 0.0h | 8.7h | 16.2h |
| 2026-10-26 | 0.0h | 0.9h | 16.5h |
| 2026-10-27 | 0.0h | 1.3h | 16.6h |