October 28, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
12
6
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | delivery_failed | Delivery recorded without a public plan write. |
| End-of-day review and reset | 00:17 | MIDNIGHT | delivery_failed | Delivery recorded without a public plan write. |
| End-of-day review and reset | 00:19 | MIDNIGHT | plan_written | Wrote public plan iris-20261028-0021. Resolved 00:23 MDT. |
| Morning planning cycle | 07:26 | SUNRISE | delivery_failed | Delivery recorded without a public plan write. |
| Morning planning cycle | 07:28 | SUNRISE | plan_written | Wrote public plan iris-20261028-0729. Resolved 07:32 MDT. |
| Forecast deviation | 08:40 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261028-0840. Resolved 08:43 MDT. |
| Forecast deviation | 09:55 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261028-0955. Resolved 09:58 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 12:47 MDT. |
| Peak Stress | 14:46 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 14:47 MDT. |
| Forecast deviation | 16:10 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261028-1610. Resolved 16:13 MDT. |
| Decline | 17:04 | TRANSITION | acked | Acknowledged: Decline checkpoint: current climate is 76.6°F/0.99 kPa with 11.2°F dew margin, IDLE apart from heat1; wet/fog relays are off. VPD has eased from ~1.18 at 16:00 to ~1.00 by 17:00, and the near-term forecast cools with overnight humidity rebound. Existing gap (60s) and fog escalation (0.35 kPa) are already conservative; no concrete residual stress justifies another tunable change. Resolved 17:05 MDT. |
| Evening planning cycle | 18:03 | SUNSET | plan_written | Wrote public plan iris-20261028-1803. Resolved 18:08 MDT. |
🌅 Morning Cycle (12:23 AM) — iris-20261028-0021
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261027-1806
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:50,“outdoor_rh_min_pct”:58,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:46.917,“notes”:“Forecast Oct 27 19:00–Oct 28 06:00 MDT: 50F falling to 37F, RH 58–83%, no solar. Indoor 72.6F/VPD 0.65/dew margin 7.9F; heat1 on. Partial Oct 27 score 59, temp 35.2%, VPD 56.1%; cold stress 11.18h and VPD-low 6.30h. Costs unavailable; outdoor forecast is not indoor response.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-27T22:00:00-06:00”,“end”:“2026-10-28T06:00:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat; require clear temperature/dewpoint advantage before exchange; penalize relay churn.”},{“kind”:“vpd_low”,“start”:“2026-10-27T23:00:00-06:00”,“end”:“2026-10-28T05:30:00-06:00”,“severity”:“medium”,“mitigation”:“Keep wet duty limited but available; hold an 8.5F dew-margin floor and follow live demand… Result: Scoped completed window iris-20261028-0021 (00:23–07:32 MDT): plan-window contract-2 planner_score 66.6; legacy both-axis/temp compliance 0%, VPD compliance 83.3%; nominal cold stress 2.74h, VPD-low 0.46h, VPD-high 0h, dew-risk 0h. Resource terms, coverage, fixed-panel and physical crop outcome evidence unavailable. Overnight wetness risk was limited, but joint/binary diagnostics and cold stress remain poor; no causal claim or durable lesson supported. Score: 5/10
Hypothesis
Expected outcome: Through 10:30 MDT, target <1h added VPD-low and dew-risk; during the late-morning dry ramp, if measured VPD exceeds its band with dew margin >=8F, allow guarded mist/fog and target VPD-high <2h. Contract-2 diagnostics only; no crop-outcome claim.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:21 | hyst 0.21750000000000003 | Cold saturated night: no forecast-only wetting; preserve hea |
| 04:30 | hyst 0.21750000000000003 | 38F pre-dawn forecast: hold dew margin and avoid unnecessary |
| 07:30 | hyst 0.20750000000000002 | Cloudy sunrise remains cold; allow only live edge demand whi |
| 10:30 | hyst 0.1975 | Dry ramp nears: band-coupled wet assist only on live VPD-hig |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:21 | s2 1.98; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.005; all 1.155; pulse 30; gap 60; wt 1.3 | Cold saturated night: no forecast-only wetting; preserve hea |
| 04:30 | s2 1.8775000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.005; all 1.155; pulse 30; gap 56.25; wt 1.3333333333333333 | 38F pre-dawn forecast: hold dew margin and avoid unnecessary |
| 07:30 | s2 1.76; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9550000000000001; all 1.105; pulse 30; gap 48.75; wt 1.4333333333333333 | Cloudy sunrise remains cold; allow only live edge demand whi |
| 10:30 | s2 1.6125; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 33.75; gap 33.75; wt 1.6666666666666665 | Dry ramp nears: band-coupled wet assist only on live VPD-hig |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:21 | band_track_fraction | initial 0 |
| 00:21 | cold_vent_guard_delta_f | initial 14 |
| 00:21 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:21 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:21 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 00:21 | dwell_gate_ms | initial 300000 |
| 00:21 | enthalpy_close | initial 1 |
| 00:21 | enthalpy_open | initial -2 |
| 00:21 | fog_escalation_kpa | initial 0.45 |
| 00:21 | heat_hysteresis | initial 1 |
| 00:21 | min_fog_off_s | initial 102 |
| 00:21 | min_fog_on_s | initial 48 |
| 00:21 | mist_backoff_s | initial 600 |
| 00:21 | mist_max_closed_vent_s | initial 600 |
| 00:21 | mist_thermal_relief_s | initial 90 |
| 00:21 | mister_all_delay_s | initial 102 |
| 00:21 | mister_engage_delay_s | initial 51 |
| 00:21 | mister_water_budget_gal | initial 120 |
| 00:21 | night_vpd_bias_kpa | initial 0 |
| 00:21 | outdoor_staleness_max_s | initial 600 |
| 00:21 | sw_dwell_gate_enabled | initial 1 |
| 00:21 | sw_fog_closes_vent | initial 1 |
| 00:21 | sw_mister_closes_vent | initial 0 |
| 00:21 | sw_summer_vent_enabled | initial 1 |
| 00:21 | temp_hysteresis | initial 2.14 |
| 00:21 | vent_exchange_fraction | initial 0.3 |
| 00:21 | vent_prefer_dp_delta_f | initial 8 |
| 00:21 | vent_prefer_temp_delta_f | initial 10 |
| 00:21 | vpd_watch_dwell_s | initial 75 |
| 04:30 | direct_wet_stress_min_dew_margin_f | 8 → 8.5 |
| 04:30 | min_fog_off_s | 102 → 96 |
| 04:30 | min_fog_on_s | 48 → 50.25 |
| 07:30 | cold_vent_guard_delta_f | 14 → 12 |
| 07:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.2 |
| 07:30 | dwell_gate_ms | 300000 → 270000 |
| 07:30 | fog_escalation_kpa | 0.45 → 0.4 |
| 07:30 | min_fog_off_s | 96 → 84 |
| 07:30 | min_fog_on_s | 50.25 → 54.75 |
| 07:30 | mister_all_delay_s | 102 → 93 |
| 07:30 | mister_engage_delay_s | 51 → 46.5 |
| 07:30 | temp_hysteresis | 2.14 → 1.96 |
| 07:30 | vent_prefer_dp_delta_f | 8 → 6 |
| 07:30 | vent_prefer_temp_delta_f | 10 → 8 |
| 07:30 | vpd_watch_dwell_s | 75 → 67.5 |
| 10:30 | cold_vent_guard_delta_f | 12 → 10 |
| 10:30 | direct_wet_stress_min_dew_margin_f | 8.5 → 8 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.05 |
| 10:30 | dwell_gate_ms | 270000 → 240000 |
| 10:30 | fog_escalation_kpa | 0.4 → 0.25 |
| 10:30 | min_fog_off_s | 84 → 60 |
| 10:30 | min_fog_on_s | 54.75 → 63.75 |
| 10:30 | mister_all_delay_s | 93 → 84 |
| 10:30 | mister_engage_delay_s | 46.5 → 42 |
| 10:30 | temp_hysteresis | 1.96 → 1.78 |
| 10:30 | vent_prefer_dp_delta_f | 6 → 4 |
| 10:30 | vent_prefer_temp_delta_f | 8 → 6 |
| 10:30 | vpd_watch_dwell_s | 67.5 → 60 |
🌅 Morning Cycle (7:32 AM) — iris-20261028-0729
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261028-0021
Previous hypothesis: Oct 27 contract-2 planner_score 63.5 (resource weight 0; terms unavailable), both-axis legacy compliance 22.2%, temp 27.8%, VPD 66.9%; nominal cold stress 16.57h, VPD-low 6.30h, VPD-high 1.28h, dew-risk 3.1h, minimum dew margin -1.7F, water 483 gal, costs unavailable. These are diagnostics, not crop outcomes. At 00:21 MDT: 62.3F/0.46 kPa, dew margin 7.6F, heat1 on. Outdoor forecast has 38F cloudy dawn, then 65-69F and 17-22% RH with VPD up to 1.99 and solar 447 W/m2; it is not indoor response. Keep wetting restrained until measured VPD rises; open band-coupled assistance during the later dry ramp only with dew margin >=8F. The prior plan still had a 05:00 waypoint at reset, so its planned window is incomplete and is not graded here; no durable causal lesson is supported. Result: Scoped completed window 07:32–08:43 MDT: window diagnostics show low nominal stress (cold 0.55h, VPD-high 0.19h, VPD-low 0.08h, dew-risk 0h), but contract-2 legacy joint/temp compliance remained 2.5%/27.7%; VPD compliance 64.8%. The brief dawn moisture/dew predictions were met within this short window, but joint performance remained poor. Resource terms, coverage, fixed-panel and physical crop outcomes are unavailable; no causal claim or durable lesson. Score: 3/10
Hypothesis
Testing: Guarded dawn-to-dry-ramp handoff: low wet duty while indoor VPD is in-band; increase band-coupled assist only on measured high VPD with dew margin >=8.5F. Expected outcome: Contract-2 diagnostics: VPD-low <2h, VPD-high <2h, dew-risk 0h. Preserve measured in-band conditions without forecast-only wetting; costs and physical crop outcomes remain unverified.
Conditions
68.0°F
21.0%
512.0 W/m²
100.0%
Mostly overcast; 68F high, 21% RH low, 512 W/m2 peak. Indoor 65.4F/0.68kPa with 10.6F dew margin; outdoor is not indoor response. Prior plan 1806 self-scored 6 vs anchor 1: short-window VPD-low 0.40h/dew-risk 0h, but temp compliance 0% and limited coverage; anchor rationale unavailable. Oct 27 dryout had no episodes, not proof of zero demand or effectiveness.
Expected stress windows
Cold, low-VPD dawn: avoid forecast-only wetting; keep 8.5F dew floor and low duty.
Only if indoor VPD exceeds its band, allow guarded band-coupled wet assist with safe dew margin.
Parameter rationale
Keep fog conditional on measured band excess and healthy dew margin; target VPD-high <2h, VPD-low <2h, and dew-risk 0h.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:29 | hyst 0.21250000000000002 | Dawn: protect the cold, low-VPD house; no forecast-only wett |
| 10:00 | hyst 0.21250000000000002 | Morning ramp: preserve heat; wait for measured indoor VPD be |
| 13:00 | hyst 0.21250000000000002 | Peak dry risk: modest band-coupled assist only if live VPD r |
| 16:00 | hyst 0.21250000000000002 | Decline: taper gradually; retain wet assist only for measure |
| 19:00 | hyst 0.21250000000000002 | Evening: small recovery shoulder until observed VPD clears i |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:29 | s2 1.995; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.206; pulse 30; gap 60; wt 1.3 | Dawn: protect the cold, low-VPD house; no forecast-only wett |
| 10:00 | s2 1.9212500000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 56.25; wt 1.4 | Morning ramp: preserve heat; wait for measured indoor VPD be |
| 13:00 | s2 1.8175000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 33.75; gap 41.25; wt 1.6 | Peak dry risk: modest band-coupled assist only if live VPD r |
| 16:00 | s2 1.9000000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 48.75; wt 1.5 | Decline: taper gradually; retain wet assist only for measure |
| 19:00 | s2 1.965; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.206; pulse 30; gap 56.25; wt 1.4 | Evening: small recovery shoulder until observed VPD clears i |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:29 | band_track_fraction | initial 0 |
| 07:29 | cold_vent_guard_delta_f | initial 12 |
| 07:29 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:29 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 07:29 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 07:29 | dwell_gate_ms | initial 285000 |
| 07:29 | enthalpy_close | initial 1 |
| 07:29 | enthalpy_open | initial -2 |
| 07:29 | fog_escalation_kpa | initial 0.4 |
| 07:29 | heat_hysteresis | initial 1 |
| 07:29 | min_fog_off_s | initial 108 |
| 07:29 | min_fog_on_s | initial 45.75 |
| 07:29 | mist_backoff_s | initial 600 |
| 07:29 | mist_max_closed_vent_s | initial 600 |
| 07:29 | mist_thermal_relief_s | initial 90 |
| 07:29 | mister_all_delay_s | initial 97.5 |
| 07:29 | mister_engage_delay_s | initial 48.75 |
| 07:29 | mister_water_budget_gal | initial 120 |
| 07:29 | night_vpd_bias_kpa | initial 0 |
| 07:29 | outdoor_staleness_max_s | initial 600 |
| 07:29 | sw_dwell_gate_enabled | initial 1 |
| 07:29 | sw_fog_closes_vent | initial 1 |
| 07:29 | sw_mister_closes_vent | initial 0 |
| 07:29 | sw_summer_vent_enabled | initial 1 |
| 07:29 | temp_hysteresis | initial 2.05 |
| 07:29 | vent_exchange_fraction | initial 0.3 |
| 07:29 | vent_prefer_dp_delta_f | initial 5 |
| 07:29 | vent_prefer_temp_delta_f | initial 8 |
| 07:29 | vpd_watch_dwell_s | initial 71.25 |
| 10:00 | fog_escalation_kpa | 0.4 → 0.35 |
| 10:00 | min_fog_off_s | 108 → 96 |
| 10:00 | min_fog_on_s | 45.75 → 50.25 |
| 13:00 | cold_vent_guard_delta_f | 12 → 10 |
| 13:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 13:00 | min_fog_off_s | 96 → 72 |
| 13:00 | min_fog_on_s | 50.25 → 59.25 |
| 13:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 13:00 | vent_prefer_temp_delta_f | 8 → 6 |
| 16:00 | fog_escalation_kpa | 0.3 → 0.35 |
| 16:00 | min_fog_off_s | 72 → 84 |
| 16:00 | min_fog_on_s | 59.25 → 54.75 |
| 19:00 | cold_vent_guard_delta_f | 10 → 12 |
| 19:00 | fog_escalation_kpa | 0.35 → 0.45 |
| 19:00 | min_fog_off_s | 84 → 96 |
| 19:00 | min_fog_on_s | 54.75 → 50.25 |
| 19:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 19:00 | vent_prefer_temp_delta_f | 6 → 8 |
🌅 Morning Cycle (8:43 AM) — iris-20261028-0840
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261028-0021
Result: Scoped completed window 08:43–09:58 MDT: window diagnostics show cold 0.58h, VPD-high 0.20h, VPD-low 0.08h, dew-risk 0h, with contract-2 legacy joint/temp compliance 2.5%/27.7% and VPD compliance 64.8%. No major humidity/dew excursion in the short interval, but poor joint/temp readings and limited duration do not validate causal benefit. Resource terms, coverage, fixed-panel and physical crop outcomes unavailable; no durable lesson. Score: 3/10
Hypothesis
Testing: Guarded dawn-to-dry-ramp handoff: low wet duty while indoor VPD is in-band; increase band-coupled assist only on measured high VPD with dew margin >=8.5F. Expected outcome: Contract-2 diagnostics: VPD-low <2h, VPD-high <2h, dew-risk 0h. Preserve measured in-band conditions without forecast-only wetting; costs and physical crop outcomes remain unverified.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:40 | hyst 0.1975 | Outdoor warmed/dried; indoor remains in corridor. Keep wetti |
| 12:00 | hyst 0.1975 | Dry ramp forecast is outdoor-only; assist only on measured i |
| 16:00 | hyst 0.1975 | Retain guarded edge assist; require measured VPD-high and >= |
| 20:00 | hyst 0.1975 | Evening taper; no forecast-only wetting, preserve cold-night |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:40 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Outdoor warmed/dried; indoor remains in corridor. Keep wetti |
| 12:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Dry ramp forecast is outdoor-only; assist only on measured i |
| 16:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Retain guarded edge assist; require measured VPD-high and >= |
| 20:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Evening taper; no forecast-only wetting, preserve cold-night |
Thursday October 29
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.1975 | Cold dawn forecast; hold heat-side discipline and avoid fore |
| 14:00 | hyst 0.1975 | Dry afternoon forecast; keep band-coupled wet assist conditi |
| 19:00 | hyst 0.1975 | Cool night; maintain experiment guardrails and conservative |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Cold dawn forecast; hold heat-side discipline and avoid fore |
| 14:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Dry afternoon forecast; keep band-coupled wet assist conditi |
| 19:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.021; all 1.221; pulse 33.75; gap 45; wt 1.5666666666666667 | Cool night; maintain experiment guardrails and conservative |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 08:40 | band_track_fraction | initial 0 |
| 08:40 | cold_vent_guard_delta_f | initial 8 |
| 08:40 | cool_stage2_exit_hysteresis_f | initial 1 |
| 08:40 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 08:40 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 08:40 | dwell_gate_ms | initial 240000 |
| 08:40 | enthalpy_close | initial 1 |
| 08:40 | enthalpy_open | initial -2 |
| 08:40 | fog_escalation_kpa | initial 0.3 |
| 08:40 | heat_hysteresis | initial 1 |
| 08:40 | min_fog_off_s | initial 78 |
| 08:40 | min_fog_on_s | initial 57 |
| 08:40 | mist_backoff_s | initial 600 |
| 08:40 | mist_max_closed_vent_s | initial 600 |
| 08:40 | mist_thermal_relief_s | initial 90 |
| 08:40 | mister_all_delay_s | initial 84 |
| 08:40 | mister_engage_delay_s | initial 42 |
| 08:40 | mister_water_budget_gal | initial 120 |
| 08:40 | night_vpd_bias_kpa | initial 0 |
| 08:40 | outdoor_staleness_max_s | initial 600 |
| 08:40 | sw_dwell_gate_enabled | initial 1 |
| 08:40 | sw_fog_closes_vent | initial 1 |
| 08:40 | sw_mister_closes_vent | initial 0 |
| 08:40 | sw_summer_vent_enabled | initial 1 |
| 08:40 | temp_hysteresis | initial 1.78 |
| 08:40 | vent_exchange_fraction | initial 0.3 |
| 08:40 | vent_prefer_dp_delta_f | initial 3 |
| 08:40 | vent_prefer_temp_delta_f | initial 4 |
| 08:40 | vpd_watch_dwell_s | initial 60 |
🌅 Morning Cycle (9:58 AM) — iris-20261028-0955
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261028-0021
Result: Scoped 2026-10-28 09:58–16:13 window: VPD-high stress 0.40h, VPD-low 0h, dew-risk 0h; joint legacy compliance 5.8%, temp 26.8%, VPD 72.3%, total nominal stress 4.35h. The plan’s dry-stress and dew-risk targets were met, but joint/temp performance remained poor. Resource terms, fixed-panel/physical crop evidence, and causal attribution are unavailable; cloud-break timing and the short scoped window limit inference. No durable lesson. Score: 4/10
Hypothesis
Testing: Guarded dawn-to-dry-ramp handoff: low wet duty while indoor VPD is in-band; increase band-coupled assist only on measured high VPD with dew margin >=8.5F. Expected outcome: Contract-2 diagnostics: VPD-low <2h, VPD-high <2h, dew-risk 0h. Preserve measured in-band conditions without forecast-only wetting; costs and physical crop outcomes remain unverified.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:55 | hyst 0.19749999999999998 | Indoor VPD is in-band; the clear-sky miss alone does not jus |
| 12:00 | hyst 0.19749999999999998 | Dry outdoor ramp merits readiness only; wet assist stays tie |
| 17:00 | hyst 0.19749999999999998 | Keep a recovery shoulder; unwind only after measured VPD cle |
| 22:00 | hyst 0.19749999999999998 | Cold night and prior VPD-low risk favor low duty with measur |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:55 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.5333333333333332 | Indoor VPD is in-band; the clear-sky miss alone does not jus |
| 12:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 33.75; gap 45; wt 1.5666666666666667 | Dry outdoor ramp merits readiness only; wet assist stays tie |
| 17:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.5333333333333332 | Keep a recovery shoulder; unwind only after measured VPD cle |
| 22:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.4666666666666666 | Cold night and prior VPD-low risk favor low duty with measur |
Thursday October 29
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.19749999999999998 | Cold dawn: keep wetting demand-gated while the heating postu |
| 12:00 | hyst 0.19749999999999998 | Cool cloudy forecast: avoid pre-emptive moisture and follow |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.4666666666666666 | Cold dawn: keep wetting demand-gated while the heating postu |
| 12:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.5 | Cool cloudy forecast: avoid pre-emptive moisture and follow |
Friday October 30
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | hyst 0.19749999999999998 | Cool morning; preserve bounded wet assist only for measured |
| 13:00 | hyst 0.19749999999999998 | Forecast dry ramp supports moderate readiness, not outdoor-t |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.5 | Cool morning; preserve bounded wet assist only for measured |
| 13:00 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.085; all 1.285; pulse 30; gap 45; wt 1.5333333333333332 | Forecast dry ramp supports moderate readiness, not outdoor-t |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 09:55 | band_track_fraction | initial 0 |
| 09:55 | cold_vent_guard_delta_f | initial 8 |
| 09:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 09:55 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 09:55 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 09:55 | dwell_gate_ms | initial 240000 |
| 09:55 | enthalpy_close | initial 1 |
| 09:55 | enthalpy_open | initial -2 |
| 09:55 | fog_escalation_kpa | initial 0.3 |
| 09:55 | heat_hysteresis | initial 1 |
| 09:55 | min_fog_off_s | initial 78 |
| 09:55 | min_fog_on_s | initial 57 |
| 09:55 | mist_backoff_s | initial 600 |
| 09:55 | mist_max_closed_vent_s | initial 600 |
| 09:55 | mist_thermal_relief_s | initial 90 |
| 09:55 | mister_all_delay_s | initial 84 |
| 09:55 | mister_engage_delay_s | initial 42 |
| 09:55 | mister_water_budget_gal | initial 120 |
| 09:55 | night_vpd_bias_kpa | initial 0 |
| 09:55 | outdoor_staleness_max_s | initial 600 |
| 09:55 | sw_dwell_gate_enabled | initial 1 |
| 09:55 | sw_fog_closes_vent | initial 1 |
| 09:55 | sw_mister_closes_vent | initial 0 |
| 09:55 | sw_summer_vent_enabled | initial 1 |
| 09:55 | temp_hysteresis | initial 1.78 |
| 09:55 | vent_exchange_fraction | initial 0.3 |
| 09:55 | vent_prefer_dp_delta_f | initial 3 |
| 09:55 | vent_prefer_temp_delta_f | initial 4 |
| 09:55 | vpd_watch_dwell_s | initial 60 |
🌆 Evening Cycle (4:13 PM) — iris-20261028-1610
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261028-0955
Previous hypothesis: Cloud alert: 0% observed versus 100% forecast near 09:55 MDT. Outdoor history is coherent with a local clear break: 50.7F/63% RH/238 W/m2 at 09:30 MDT, solar now 347 W/m2. No cloud-specific calibration is available; small temperature/RH biases do not transfer. Indoor is 67.9F/0.76 kPa with 11.2F dew margin; VPD is within its served band, heat1+heat2 are on, and vent/fans/wet relays are off. This is a weather/forecast timing miss, not equipment failure or proof of indoor dry stress. Preserve guarded, measured-demand moisture. Prior plan iris-20261028-0021 self-score 5 vs anchor 1: I over-weighted 0.46h VPD-low/0h dew risk and under-weighted 0% binary both-axis/temp compliance and 2.74h cold stress; coverage and crop outcomes are unavailable, so no causal lesson. Result: Scoped 2026-10-28 16:13–18:08 window: VPD-high stress 0.11h, VPD-low 0h, dew-risk 0h; joint legacy compliance 5.4%, temp 24.7%, VPD 74.4%, total nominal stress 1.24h. The forecast-mismatch response preserved measured-demand-only moisture and avoided humidity/dew excursions in this short interval, but joint/temp diagnostics remained weak; no evidence of causal improvement, resource benefit, or crop outcome. No durable lesson. Score: 5/10
Hypothesis
Testing: Guarded dawn-to-dry-ramp handoff: low wet duty while indoor VPD is in-band; increase band-coupled assist only on measured high VPD with dew margin >=8.5F. Expected outcome: Contract-2 diagnostics: VPD-low <2h, VPD-high <2h, dew-risk 0h. Preserve measured in-band conditions without forecast-only wetting; costs and physical crop outcomes remain unverified.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:10 | hyst 0.1875 | Current VPD near edge, dew margin healthy; allow only measur |
| 20:00 | hyst 0.1875 | After the dry forecast miss, taper wet duty; preserve dew pr |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:10 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | Current VPD near edge, dew margin healthy; allow only measur |
| 20:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | After the dry forecast miss, taper wet duty; preserve dew pr |
Thursday October 29
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.1875 | Cold dawn forecast; avoid humidity preloading and wait for f |
| 11:00 | hyst 0.1875 | Cloudy cool ramp favors low duty; assist remains conditional |
| 15:00 | hyst 0.1875 | Forecasted mild dry ramp; restore guarded assist only if ind |
| 18:00 | hyst 0.1875 | Evening cooldown; taper only after observed VPD recovers and |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | Cold dawn forecast; avoid humidity preloading and wait for f |
| 11:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | Cloudy cool ramp favors low duty; assist remains conditional |
| 15:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | Forecasted mild dry ramp; restore guarded assist only if ind |
| 18:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.117; all 1.317; pulse 33.75; gap 41.25; wt 1.7 | Evening cooldown; taper only after observed VPD recovers and |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:10 | band_track_fraction | initial 0 |
| 16:10 | cold_vent_guard_delta_f | initial 8 |
| 16:10 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:10 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 16:10 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:10 | dwell_gate_ms | initial 210000 |
| 16:10 | enthalpy_close | initial 1 |
| 16:10 | enthalpy_open | initial -2 |
| 16:10 | fog_escalation_kpa | initial 0.25 |
| 16:10 | heat_hysteresis | initial 1 |
| 16:10 | min_fog_off_s | initial 72 |
| 16:10 | min_fog_on_s | initial 59.25 |
| 16:10 | mist_backoff_s | initial 600 |
| 16:10 | mist_max_closed_vent_s | initial 600 |
| 16:10 | mist_thermal_relief_s | initial 90 |
| 16:10 | mister_all_delay_s | initial 75 |
| 16:10 | mister_engage_delay_s | initial 37.5 |
| 16:10 | mister_water_budget_gal | initial 120 |
| 16:10 | night_vpd_bias_kpa | initial 0 |
| 16:10 | outdoor_staleness_max_s | initial 600 |
| 16:10 | sw_dwell_gate_enabled | initial 1 |
| 16:10 | sw_fog_closes_vent | initial 1 |
| 16:10 | sw_mister_closes_vent | initial 0 |
| 16:10 | sw_summer_vent_enabled | initial 1 |
| 16:10 | temp_hysteresis | initial 1.6 |
| 16:10 | vent_exchange_fraction | initial 0.3 |
| 16:10 | vent_prefer_dp_delta_f | initial 3 |
| 16:10 | vent_prefer_temp_delta_f | initial 4 |
| 16:10 | vpd_watch_dwell_s | initial 52.5 |
🌆 Evening Cycle (6:08 PM) — iris-20261028-1803
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261028-0955
Result: Scoped completed window 2026-10-28 18:08–2026-10-29 00:19: contract-2 planner_score 63.9; VPD compliance 100%, no VPD-high/VPD-low or dew-risk hours, with about 1.75h nominal cold stress and weak joint/temp compliance (0% in window diagnostics). The no-forecast-only-wetting / low VPD-low and zero dew-risk expectation was met, but the cold and joint diagnostics remain poor. Resource terms, coverage, fixed-panel and physical crop outcomes are unavailable; no causal effectiveness claim. Score: 5/10
Hypothesis
Testing: Continue guarded dawn-to-dry-ramp: no forecast-only wetting; assist only on measured VPD-high with dew margin >=8.5F. Expected outcome: Overnight diagnostics target cold stress <6h, VPD-low <2h, and dew-risk 0h; avoid forecast-only wetting. Cost, physical exposure and crop benefit remain unverified.
Conditions
54.0°F
35.0%
0.0 W/m²
40.0%
Overnight forecast: 54F early evening falling to 39F by dawn, RH rising to 81%, outdoor VPD falling to 0.15 kPa; no solar. Indoor response and cost are not inferred.
Expected stress windows
Preserve heat; require a strong outdoor temperature advantage before exchange; discourage relay churn.
Avoid forecast-only wetting; retain a dew-margin floor and allow wet assist only on measured band excess.
Parameter rationale
Avoid forecast-led wetting while preserving measured high-VPD assist at dew margin >=8.5F; target VPD-low <2h and dew-risk 0h.
Setpoints
Wednesday October 28
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:03 | hyst 0.2125 | evening_settle: conserve heat; no forecast-only wetting; ret |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:03 | s2 1.8625; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 52.5; wt 1.4 | evening_settle: conserve heat; no forecast-only wetting; ret |
Thursday October 29
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.2175 | midnight_posture: cold, humid forecast; keep wet duty minima |
| 05:30 | hyst 0.2125 | pre_dawn: preserve heat; reopen band-coupled assist only if |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.98; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.196; all 1.2959999999999998; pulse 30; gap 60; wt 1.3 | midnight_posture: cold, humid forecast; keep wet duty minima |
| 05:30 | s2 1.8475000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.996; all 1.196; pulse 30; gap 48.75; wt 1.5 | pre_dawn: preserve heat; reopen band-coupled assist only if |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:03 | band_track_fraction | initial 0 |
| 18:03 | cold_vent_guard_delta_f | initial 12 |
| 18:03 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:03 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 18:03 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 18:03 | dwell_gate_ms | initial 285000 |
| 18:03 | enthalpy_close | initial 1 |
| 18:03 | enthalpy_open | initial -2 |
| 18:03 | fog_escalation_kpa | initial 0.45 |
| 18:03 | heat_hysteresis | initial 1 |
| 18:03 | min_fog_off_s | initial 90 |
| 18:03 | min_fog_on_s | initial 52.5 |
| 18:03 | mist_backoff_s | initial 600 |
| 18:03 | mist_max_closed_vent_s | initial 600 |
| 18:03 | mist_thermal_relief_s | initial 90 |
| 18:03 | mister_all_delay_s | initial 97.5 |
| 18:03 | mister_engage_delay_s | initial 48.75 |
| 18:03 | mister_water_budget_gal | initial 120 |
| 18:03 | night_vpd_bias_kpa | initial 0 |
| 18:03 | outdoor_staleness_max_s | initial 600 |
| 18:03 | sw_dwell_gate_enabled | initial 1 |
| 18:03 | sw_fog_closes_vent | initial 1 |
| 18:03 | sw_mister_closes_vent | initial 0 |
| 18:03 | sw_summer_vent_enabled | initial 1 |
| 18:03 | temp_hysteresis | initial 2.05 |
| 18:03 | vent_exchange_fraction | initial 0.3 |
| 18:03 | vent_prefer_dp_delta_f | initial 4 |
| 18:03 | vent_prefer_temp_delta_f | initial 8 |
| 18:03 | vpd_watch_dwell_s | initial 71.25 |
| 00:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.25 |
| 00:00 | dwell_gate_ms | 285000 → 300000 |
| 00:00 | fog_escalation_kpa | 0.45 → 0.5 |
| 00:00 | min_fog_off_s | 90 → 102 |
| 00:00 | min_fog_on_s | 52.5 → 48 |
| 00:00 | mister_all_delay_s | 97.5 → 102 |
| 00:00 | mister_engage_delay_s | 48.75 → 51 |
| 00:00 | temp_hysteresis | 2.05 → 2.14 |
| 00:00 | vpd_watch_dwell_s | 71.25 → 75 |
| 05:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 05:30 | dwell_gate_ms | 300000 → 285000 |
| 05:30 | fog_escalation_kpa | 0.5 → 0.3 |
| 05:30 | min_fog_off_s | 102 → 84 |
| 05:30 | min_fog_on_s | 48 → 54.75 |
| 05:30 | mister_all_delay_s | 102 → 97.5 |
| 05:30 | mister_engage_delay_s | 51 → 48.75 |
| 05:30 | temp_hysteresis | 2.14 → 2.05 |
| 05:30 | vpd_watch_dwell_s | 75 → 71.25 |
End-of-Day Summary
Climate
59.2–82.5°F; avg 68.4°F
0.41–1.36 kPa; avg 0.73 kPa
60.3–78.8%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 4.8h
- Cold stress (<55°F): 16.7h
Economics
Not available
USD 1.13
USD 0.020
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 4 min | Fogger runtime. |
| Heat 1 electric | 1280 min | Electric heater runtime. |
| Heat 2 gas | 109 min | Gas heater runtime. |
| Grow lights | 1002 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 4 gal
- Mister: 3 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 63% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 68% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 53% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Potted tree visible on the far left shelf. Foliage appears dense and healthy. No visible yellowing or browning. || Vegetative growth is visible in the west zone; plants appear green and turgid despite the unavailable' soil moisture reading. || [dormancy] A potted tree is visible on the far left (west zone). It appears structurally intact but is in a dark environment. The unavailable' soil moisture reading is inconclusive. || [leaf drop, dry soil] Potted tree on the left side. Some leaves appear brown or dry. The unavailable' soil moisture reading is likely a sensor error, but the plant shows signs of stress. || [leaf drop, dry soil] Small tree in a blue pot on the far left. Leaves are sparse and some appear brown/dried. Soil moisture is not available but likely low given the dry floor conditions. || [leaf yellowing] The potted plant in the bottom right corner shows significant yellowing of the lower leaves, possibly due to nutrient deficiency or overwatering. || [potential water stress] Vegetative pl
Hanging baskets visible in the center of the room. Roots appear exposed and healthy. No visible wilting or leaf drop. || [exposed roots, potential dehydration] Hanging baskets visible in the center. Roots appear exposed and dry, which is typical for Vanda but requires monitoring given the 0% soil moisture reading in the south zone. || [root exposure] Hanging baskets visible in the center background. Roots appear dry and exposed, which is typical for Vanda but requires monitoring given the 0% soil moisture reading. || [root exposure] Hanging baskets visible in the center. Roots appear long and exposed, which is typical for Vanda, but the 0.0% soil moisture reading (likely referring to the floor area or a sensor error) and 0 lux light suggest the plants are in a dark, potentially dry cycle.
Seedlings visible on the right-side shelving units. Plants appear upright and intact. No obvious signs of wilting or pest damage visible in this view. || [low light, low soil moisture] Seedlings visible on the right-side shelving units. The 0 lux light reading suggests the grow lights are off or the sensor is faulty, which is critical for seedlings. Soil moisture in the south (likely corresponding to this zone) is critically low at 0.0%. || [wilting, dehydration] Seedlings in the east zone appear wilted and stressed, likely due to the reported 0.0% soil moisture in the south/east area. || [wilting, drying] Seedlings in the blue trays on the left shelving appear sparse and dry, consistent with the 0.0% soil moisture reading.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 74.2°F | 0.66 kPa | 77.1% |
| 13:00 | 76.8°F | 0.81 kPa | 74.3% |
| 14:00 | 77.6°F | 0.88 kPa | 73.0% |
| 15:00 | 80.8°F | 1.06 kPa | 70.5% |
| 16:00 | 80.6°F | 0.99 kPa | 72.5% |
| 17:00 | 74.9°F | 0.73 kPa | 75.3% |
| 18:00 | 72.6°F | 0.66 kPa | 75.9% |
| 19:00 | 70.9°F | 0.64 kPa | 75.3% |
| 20:00 | 68.7°F | 0.57 kPa | 76.1% |
| 21:00 | 67.4°F | 0.57 kPa | 75.4% |
| 22:00 | 64.9°F | 0.50 kPa | 76.5% |
| 23:00 | 63.3°F | 0.48 kPa | 76.2% |
| 00:00 | 62.2°F | 0.46 kPa | 76.2% |
| 01:00 | 61.5°F | 0.44 kPa | 76.4% |
| 02:00 | 60.4°F | 0.44 kPa | 75.5% |
| 03:00 | 59.8°F | 0.43 kPa | 75.5% |
| 04:00 | 61.2°F | 0.49 kPa | 73.8% |
| 05:00 | 61.7°F | 0.50 kPa | 73.5% |
| 06:00 | 62.6°F | 0.53 kPa | 72.7% |
| 07:00 | 64.1°F | 0.60 kPa | 70.9% |
| 08:00 | 66.2°F | 0.68 kPa | 68.9% |
| 09:00 | 68.6°F | 0.79 kPa | 67.2% |
| 10:00 | 71.0°F | 0.87 kPa | 66.6% |
| 11:00 | 73.2°F | 0.94 kPa | 66.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-22 | 0.0h | 7.3h | 14.9h |
| 2026-10-23 | 0.5h | 6.5h | 14.7h |
| 2026-10-24 | 0.0h | 7.5h | 15.8h |
| 2026-10-25 | 0.0h | 8.7h | 16.2h |
| 2026-10-26 | 0.0h | 0.9h | 16.5h |
| 2026-10-27 | 0.0h | 1.3h | 16.6h |
| 2026-10-28 | 0.0h | 4.8h | 16.7h |