October 29, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

6

Plan writes

3

No-change acknowledgements

2

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:16MIDNIGHTplan_writtenWrote public plan iris-20261029-0016. Resolved 00:19 MDT.
Morning planning cycle07:28SUNRISEplan_writtenWrote public plan iris-20261029-0728. Resolved 07:31 MDT.
Solar peak planning checkpoint12:46SOLAR_MAXaction_completedDelivery recorded without a public plan write. Resolved 12:48 MDT.
Peak Stress14:46TRANSITIONackedAcknowledged: No one-shot change: fresh indoor 78.1F/1.24 kPa, dew margin 13.9F, no heat stress; scoped VPD-high 1.13h remains below plan's <2h target, and the scheduled 16:00 waypoint already tightens mist gap. Resolved 14:47 MDT.
Decline17:02TRANSITIONackedAcknowledged: Decline is tracking the existing staged taper: indoor VPD is 1.02 kPa (east 1.11) with 11.6°F dew margin, IDLE/heat1 only and no wet demand; 6h trend has eased from 1.32 to 1.02. The active plan already raises engage/gap/fog escalation at 18:00 and again at 20:00, while evening forecast VPD falls. No additional tunable change warranted. Resolved 17:03 MDT.
Evening planning cycle18:03SUNSETplan_writtenWrote public plan iris-20261029-1803. Resolved 18:06 MDT.

🌅 Morning Cycle (12:19 AM) — iris-20261029-0016

Status

validated

Outcome score

5/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261028-1803

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:54.0,“outdoor_rh_min_pct”:35.0,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:40.0,“notes”:“Overnight forecast: 54F early evening falling to 39F by dawn, RH rising to 81%, outdoor VPD falling to 0.15 kPa; no solar. Indoor response and cost are not inferred.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-29T02:00:00-06:00”,“end”:“2026-10-29T07:00:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat; require a strong outdoor temperature advantage before exchange; discourage relay churn.”},{“kind”:“vpd_low”,“start”:“2026-10-29T02:00:00-06:00”,“end”:“2026-10-29T08:00:00-06:00”,“severity”:“medium”,“mitigation”:“Avoid forecast-only wetting; retain a dew-margin floor and allow wet assist only on measured band excess.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:0.889,“new_value”:1.14,“forecast_anchor”:“Outdoor VPD falls to 0.15-0… Result: Plan window 2026-10-29 00:19–07:31 MDT, scoped scorecard: contract-2 planner score 71.1; joint legacy compliance 6.0%, temp 32.5%, VPD 61.6%; nominal cold stress 3.43h, VPD-high 1.95h, VPD-low 0h, dew-risk 0h. The moisture/dew guardrail outcome was good, but cold stress and joint/temp diagnostics remained poor. Resource terms were unavailable; coverage is unverified and this is not a physical crop outcome. Score: 5/10

Hypothesis

Testing: Guarded cold/humid dawn, then band-coupled wet assist only on live VPD-high with dew margin at least 8°F. Expected outcome: Through early-day handoff: avoid forecast-only wetting; target zero dew-risk and <1h additional VPD-low stress while retaining measured high-VPD assistance. No cost or crop-benefit claim.

Setpoints

Thursday October 29

Primary crop-band changes:

TimeValuesNote
00:16hyst 0.21750000000000003Cold humid night; avoid in-band wetting and unnecessary cold
04:30hyst 0.2175000000000000339°F dawn forecast; retain stable heat posture and require l
07:30hyst 0.21250000000000002Cloud timing is uncertain; keep dawn conservative and respon
10:30hyst 0.20750000000000002Early-day handoff: permit bounded wet assist only above the

Tactical tunable changes:

TimeValuesNote
00:16s2 1.965; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.875; all 1.055; pulse 30; gap 56.25; wt 1.4Cold humid night; avoid in-band wetting and unnecessary cold
04:30s2 1.965; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.855; all 1.055; pulse 30; gap 56.25; wt 1.439°F dawn forecast; retain stable heat posture and require l
07:30s2 1.8475000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 48.75; wt 1.5Cloud timing is uncertain; keep dawn conservative and respon
10:30s2 1.8325; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 33.75; gap 45; wt 1.5666666666666667Early-day handoff: permit bounded wet assist only above the

Changed secondary parameters:

TimeParameterChange
00:16band_track_fractioninitial 0
00:16cold_vent_guard_delta_finitial 12
00:16cool_stage2_exit_hysteresis_finitial 1
00:16direct_wet_stress_min_dew_margin_finitial 8
00:16direct_wet_stress_vpd_margin_kpainitial 0.12
00:16dwell_gate_msinitial 300000
00:16enthalpy_closeinitial 1
00:16enthalpy_openinitial -2
00:16fog_escalation_kpainitial 0.35
00:16heat_hysteresisinitial 1
00:16min_fog_off_sinitial 96
00:16min_fog_on_sinitial 50.25
00:16mist_backoff_sinitial 600
00:16mist_max_closed_vent_sinitial 600
00:16mist_thermal_relief_sinitial 90
00:16mister_all_delay_sinitial 102
00:16mister_engage_delay_sinitial 51
00:16mister_water_budget_galinitial 120
00:16night_vpd_bias_kpainitial 0
00:16outdoor_staleness_max_sinitial 600
00:16sw_dwell_gate_enabledinitial 1
00:16sw_fog_closes_ventinitial 1
00:16sw_mister_closes_ventinitial 0
00:16sw_summer_vent_enabledinitial 1
00:16temp_hysteresisinitial 2.14
00:16vent_exchange_fractioninitial 0.3
00:16vent_prefer_dp_delta_finitial 4.5
00:16vent_prefer_temp_delta_finitial 8
00:16vpd_watch_dwell_sinitial 75
04:30direct_wet_stress_vpd_margin_kpa0.12 → 0.1
07:30cold_vent_guard_delta_f12 → 10
07:30direct_wet_stress_vpd_margin_kpa0.1 → 0.05
07:30dwell_gate_ms300000 → 285000
07:30fog_escalation_kpa0.35 → 0.3
07:30min_fog_off_s96 → 84
07:30min_fog_on_s50.25 → 54.75
07:30mister_all_delay_s102 → 97.5
07:30mister_engage_delay_s51 → 48.75
07:30temp_hysteresis2.14 → 2.05
07:30vent_prefer_dp_delta_f4.5 → 4
07:30vent_prefer_temp_delta_f8 → 6
07:30vpd_watch_dwell_s75 → 71.25
10:30dwell_gate_ms285000 → 270000
10:30fog_escalation_kpa0.3 → 0.25
10:30min_fog_off_s84 → 78
10:30min_fog_on_s54.75 → 57
10:30mister_all_delay_s97.5 → 93
10:30mister_engage_delay_s48.75 → 46.5
10:30temp_hysteresis2.05 → 1.96
10:30vpd_watch_dwell_s71.25 → 67.5

🌅 Morning Cycle (7:31 AM) — iris-20261029-0728

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261029-0016

Previous hypothesis: Oct 28 contract-2 score was 73.4 with resource weight 0; legacy joint/temp/VPD compliance 5.8/26.8/72.3%, nominal stress 23.05h (cold 16.72h, VPD-high 4.8h, VPD-low 1.53h), and dew-risk 0h. These are diagnostics, not physical crop outcomes. I evaluated 0955 and 1610 at 4 and 5 versus deterministic anchors 1 and 1: I over-weighted their low scoped VPD-high (0.40/0.11h) and zero dew/VPD-low stress while under-weighting weak joint/temp readings; no durable causal lesson is supported. Plan 1803 still had a 05:30 waypoint and remains incomplete. Current climate is 63°F/0.50 kPa with 8.2°F dew margin and heat1 on; forecast is 37–39°F pre-dawn, then a cloudy/uncertain dry ramp. Hold wetting while in-band, protect the cold dawn, and make band-coupled assistance available only on measured VPD-high with a safe dew margin. Result: Scoped window for iris-20261029-0728: planner score 73.8; contract-2 legacy temp/VPD fractions 25.6%/71.4%; nominal stress heat 0.00h, cold 7.43h, VPD-high 2.85h, VPD-low 0.01h; dew-risk 0h. The predicted VPD-high <2h was missed; VPD-low <1h and no dew-risk were met. The plan audit had numerous missed requests, so attribution to requested tactics is weak. Resource terms and physical crop outcomes are unavailable. Whole-day Oct 29 score was 73.9, with cold stress the largest axis, but is not attributed to this daylight plan. Score: 4/10

Hypothesis

Testing: Guarded dawn-to-dry-ramp: keep wetting demand-led, then test band-coupled assist only on live VPD excess with safe dew margin. Expected outcome: By evening, avoid forecast-only wetting; target VPD-high stress <2h, VPD-low <1h, dew-risk 0h and dew margin >5°F, while retaining assist on measured excess. No resource-savings or crop-outcome claim.

Conditions

Outdoor peak

65.0°F

RH minimum

26.0%

Solar peak

535.0 W/m²

Cloud average

50.0%

Cold 35°F/high-RH dawn; forecast warms to 65°F with outdoor VPD peaking 1.57 kPa at 16:00 as afternoon cloud thickens. Indoor is 65°F/0.71 kPa, dew margin 11.5°F. Prior 1803 self-score 5 vs anchor 1: I credited VPD/dew predictions despite weak joint/temp diagnostics; exact anchor rationale unavailable.

Expected stress windows

coldmedium · 2026-10-29T07:28:00-06:00 to 2026-10-29T10:00:00-06:00

Preserve heat; no forecast-led wetting while indoor VPD remains below its high edge.

vpd_highmedium · 2026-10-29T12:00:00-06:00 to 2026-10-29T18:00:00-06:00

Enable band-coupled assist only on live excess with dew margin >=8°F; taper only after observed recovery.

Parameter rationale

mister_engage_kpa0.889 → 0.952; Outdoor VPD forecast peaks at 1.57 kPa by 16:00, but indoor VPD is 0.71 with 11.5°F dew margin now.

Permit assist near live band excess, not from forecast alone; target VPD-high <2h and dew-risk 0h.

Setpoints

Thursday October 29

Primary crop-band changes:

TimeValuesNote
07:28hyst 0.20750000000000002Dawn: cold heating load; VPD is in-band, so avoid forecast-o
10:00hyst 0.20750000000000002Morning ramp: keep wet assist gated to measured excess as ou
16:00hyst 0.20750000000000002Peak forecast dryness: preserve band-coupled wet assist only
18:00hyst 0.20750000000000002Decline: retain a short recovery shoulder; unwind only after
20:00hyst 0.20750000000000002Evening cool-down: constrain wetting for forecast VPD fall;

Tactical tunable changes:

TimeValuesNote
07:28s2 1.965; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.055; all 1.255; pulse 30; gap 56.25; wt 1.4Dawn: cold heating load; VPD is in-band, so avoid forecast-o
10:00s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.0050000000000001; all 1.205; pulse 30; gap 48.75; wt 1.5Morning ramp: keep wet assist gated to measured excess as ou
16:00s2 1.905; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9550000000000001; all 1.155; pulse 33.75; gap 41.25; wt 1.6Peak forecast dryness: preserve band-coupled wet assist only
18:00s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.985; all 1.205; pulse 30; gap 48.75; wt 1.5Decline: retain a short recovery shoulder; unwind only after
20:00s2 1.995; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.055; all 1.255; pulse 30; gap 60; wt 1.3Evening cool-down: constrain wetting for forecast VPD fall;

Changed secondary parameters:

TimeParameterChange
07:28band_track_fractioninitial 0
07:28cold_vent_guard_delta_finitial 8
07:28cool_stage2_exit_hysteresis_finitial 1
07:28direct_wet_stress_min_dew_margin_finitial 8
07:28direct_wet_stress_vpd_margin_kpainitial 0.15
07:28dwell_gate_msinitial 270000
07:28enthalpy_closeinitial 1
07:28enthalpy_openinitial -2
07:28fog_escalation_kpainitial 0.35
07:28heat_hysteresisinitial 1
07:28min_fog_off_sinitial 96
07:28min_fog_on_sinitial 50.25
07:28mist_backoff_sinitial 600
07:28mist_max_closed_vent_sinitial 600
07:28mist_thermal_relief_sinitial 90
07:28mister_all_delay_sinitial 93
07:28mister_engage_delay_sinitial 46.5
07:28mister_water_budget_galinitial 120
07:28night_vpd_bias_kpainitial 0
07:28outdoor_staleness_max_sinitial 600
07:28sw_dwell_gate_enabledinitial 1
07:28sw_fog_closes_ventinitial 1
07:28sw_mister_closes_ventinitial 0
07:28sw_summer_vent_enabledinitial 1
07:28temp_hysteresisinitial 1.96
07:28vent_exchange_fractioninitial 0.3
07:28vent_prefer_dp_delta_finitial 3
07:28vent_prefer_temp_delta_finitial 4
07:28vpd_watch_dwell_sinitial 67.5
10:00direct_wet_stress_vpd_margin_kpa0.15 → 0.1
10:00fog_escalation_kpa0.35 → 0.3
10:00min_fog_off_s96 → 84
10:00min_fog_on_s50.25 → 54.75
16:00direct_wet_stress_vpd_margin_kpa0.1 → 0.05
16:00fog_escalation_kpa0.3 → 0.25
16:00min_fog_off_s84 → 72
16:00min_fog_on_s54.75 → 59.25
18:00direct_wet_stress_vpd_margin_kpa0.05 → 0.08
18:00fog_escalation_kpa0.25 → 0.3
18:00min_fog_off_s72 → 84
18:00min_fog_on_s59.25 → 54.75
20:00direct_wet_stress_vpd_margin_kpa0.08 → 0.15
20:00fog_escalation_kpa0.3 → 0.4
20:00min_fog_off_s84 → 108
20:00min_fog_on_s54.75 → 45.75

🌆 Evening Cycle (6:06 PM) — iris-20261029-1803

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261029-0728

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:65,“outdoor_rh_min_pct”:26,“solar_peak_w_m2”:535,“cloud_cover_avg_pct”:50,“notes”:“Cold 35°F/high-RH dawn; forecast warms to 65°F with outdoor VPD peaking 1.57 kPa at 16:00 as afternoon cloud thickens. Indoor is 65°F/0.71 kPa, dew margin 11.5°F. Prior 1803 self-score 5 vs anchor 1: I credited VPD/dew predictions despite weak joint/temp diagnostics; exact anchor rationale unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-29T07:28:00-06:00”,“end”:“2026-10-29T10:00:00-06:00”,“severity”:“medium”,“mitigation”:“Preserve heat; no forecast-led wetting while indoor VPD remains below its high edge.”},{“kind”:“vpd_high”,“start”:“2026-10-29T12:00:00-06:00”,“end”:“2026-10-29T18:00:00-06:00”,“severity”:“medium”,“mitigation”:“Enable band-coupled assist only on live excess with dew margin >=8°F; taper only after observed recovery… Result: Evaluated at supersession 2026-10-30 00:20 MDT; scoped window row for iris-20261029-1803 reports 0.0 across its legacy metrics, but has no usable eligible outcome evidence. Oct 29 whole-day contract-2 score was 73.9, with nominal cold 16.75h, VPD-high 6.52h, VPD-low 0h, dew-risk 0h; these cannot be attributed to this plan’s window. The hypotheses (cold ⇐3.5h, VPD-low <1h, dew-risk 0h) are therefore not verifiable for the scoped window; only whole-day dew-risk was 0. Resources are null, coverage unverified, and physical crop evidence unavailable. Fresh current climate is 62.7°F/0.48 kPa with 7.9°F dew margin. Score: 4/10

Hypothesis

Expected outcome: Through the cold night and morning, target dew-risk 0h and VPD-low <1h while retaining edge-responsive moisture; keep plan-window cold stress at or below 3.5h if feasible. Cost and crop outcomes remain unverified.

Conditions

Outdoor peak

52.0°F

RH minimum

41.0%

Solar peak

0.0 W/m²

Cloud average

95.0%

Cold overcast night: outdoor 52°F early, 42°F pre-dawn, RH to 100%, VPD 0.00 by 05:00; house 72.6°F/0.82 kPa, dew margin 10.3°F. Prior 0016 score 5 vs anchor 1: I overweighted zero VPD-low/dew risk but underweighted 3.43h cold stress and weak 6% joint/temp metrics. Resource terms unavailable; no crop-outcome claim.

Expected stress windows

coldhigh · 2026-10-29T20:00:00-06:00 to 2026-10-30T07:00:00-06:00

Protect heat; require a stronger outdoor temperature advantage before exchange; damp relay churn.

vpd_lowmedium · 2026-10-30T00:00:00-06:00 to 2026-10-30T06:00:00-06:00

No forecast-only wetting; retain dew margin and respond only to measured demand.

Parameter rationale

mister_engage_kpa1.6 → 1.0; House VPD is 0.82 below the 0.95 high edge; prior plan window recorded 2.85h VPD-high and 0h dew risk.

Keep a bounded evening recovery path at the band edge, then avoid forecast-led wetting; target overnight VPD-low <1h and dew-risk 0h.

vent_prefer_temp_delta_f5.0 → 8.0; Outdoor temperature falls from 52°F to 42°F before dawn, with RH rising to saturation.

Reduce cold-air exchange; target overnight-window cold stress no worse than 3.5h and dew-risk 0h.

Setpoints

Thursday October 29

Primary crop-band changes:

TimeValuesNote
18:03hyst 0.20749999999999996Evening recovery bridge; current VPD is in-band, so keep wet

Tactical tunable changes:

TimeValuesNote
18:03s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.996; all 1.196; pulse 30; gap 41.25; wt 1.5333333333333332Evening recovery bridge; current VPD is in-band, so keep wet

Friday October 30

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.2175Cold humid trough; preserve heat and avoid forecast-only moi
05:00hyst 0.22249999999999998Pre-dawn low is 42-44°F and saturated; favor heat retention

Tactical tunable changes:

TimeValuesNote
00:00s2 1.965; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.146; all 1.346; pulse 30; gap 56.25; wt 1.3666666666666667Cold humid trough; preserve heat and avoid forecast-only moi
05:00s2 1.95; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.146; all 1.346; pulse 30; gap 52.5; wt 1.4Pre-dawn low is 42-44°F and saturated; favor heat retention

Changed secondary parameters:

TimeParameterChange
18:03band_track_fractioninitial 0
18:03cold_vent_guard_delta_finitial 12
18:03cool_stage2_exit_hysteresis_finitial 1
18:03direct_wet_stress_min_dew_margin_finitial 8
18:03direct_wet_stress_vpd_margin_kpainitial 0.05
18:03dwell_gate_msinitial 270000
18:03enthalpy_closeinitial 1
18:03enthalpy_openinitial -2
18:03fog_escalation_kpainitial 0.35
18:03heat_hysteresisinitial 1
18:03min_fog_off_sinitial 72
18:03min_fog_on_sinitial 59.25
18:03mist_backoff_sinitial 600
18:03mist_max_closed_vent_sinitial 600
18:03mist_thermal_relief_sinitial 90
18:03mister_all_delay_sinitial 93
18:03mister_engage_delay_sinitial 46.5
18:03mister_water_budget_galinitial 120
18:03night_vpd_bias_kpainitial 0
18:03outdoor_staleness_max_sinitial 600
18:03sw_dwell_gate_enabledinitial 1
18:03sw_fog_closes_ventinitial 1
18:03sw_mister_closes_ventinitial 0
18:03sw_summer_vent_enabledinitial 1
18:03temp_hysteresisinitial 1.96
18:03vent_exchange_fractioninitial 0.3
18:03vent_prefer_dp_delta_finitial 4
18:03vent_prefer_temp_delta_finitial 8
18:03vpd_watch_dwell_sinitial 67.5
00:00direct_wet_stress_min_dew_margin_f8 → 8.5
00:00direct_wet_stress_vpd_margin_kpa0.05 → 0.2
00:00dwell_gate_ms270000 → 300000
00:00fog_escalation_kpa0.35 → 0.5
00:00min_fog_off_s72 → 96
00:00min_fog_on_s59.25 → 50.25
00:00mister_all_delay_s93 → 102
00:00mister_engage_delay_s46.5 → 51
00:00mister_water_budget_gal120 → 100
00:00temp_hysteresis1.96 → 2.14
00:00vpd_watch_dwell_s67.5 → 75
05:00cold_vent_guard_delta_f12 → 13
05:00dwell_gate_ms300000 → 315000
05:00min_fog_off_s96 → 90
05:00min_fog_on_s50.25 → 52.5
05:00mister_all_delay_s102 → 106.5
05:00mister_engage_delay_s51 → 53.25
05:00temp_hysteresis2.14 → 2.23
05:00vent_prefer_dp_delta_f4 → 4.5
05:00vent_prefer_temp_delta_f8 → 9
05:00vpd_watch_dwell_s75 → 78.75

End-of-Day Summary

Climate

Temperature

59.4–80.4°F; avg 68.2°F

VPD

0.45–1.78 kPa; avg 0.81 kPa

Relative humidity

44.1–77.6%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: legacy_invalid_exterior_proxy_plus_fixture_estimate
  • Validity: dli-validity-v1; 2024-01-01T00:00:00+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (>85°F): 0.0h
  • VPD stress (>2.0 kPa): 6.5h
  • Cold stress (<55°F): 16.9h

Economics

Electric

Not available

Gas

USD 3.34

Water

Not available

Total

Not available

Equipment Runtimes

EquipmentRuntimeReading
Fan 10 minPrimary exhaust runtime.
Fan 20 minSecondary exhaust runtime.
Vent0 minIntake vent runtime.
Fog45 minFogger runtime.
Heat 1 electric1311 minElectric heater runtime.
Heat 2 gas322 minGas heater runtime.
Grow lights842 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center0.00hCenter mister runtime.

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Lime Treewest70%8Observation notes are collapsed below to avoid publishing partial vision snippets.
Vanda Orchidscenter78%4Observation notes are collapsed below to avoid publishing partial vision snippets.
peppereast73%4Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
Lime TreeGemini Vision notes

Large potted tree in the west zone. Dense, dark green canopy. No visible signs of stress or pest damage. || Plant appears robust with a dense canopy of leaves. No visible signs of wilting or leaf drop. The foliage is bright in the IR spectrum, indicating healthy turgor. || Potted tree visible in the west zone. Structure appears intact. Soil moisture data is missing, making hydration status uncertain. || Potted tree visible on the far left shelf. Foliage appears dense and upright, though specific soil moisture data is missing. || [exposed roots, potential root dryness] Large specimen with extensive exposed root system. While leaves are green, the exposed roots appear dry and brittle, suggesting a need for humidity or root protection. || [potential water stress] Potted citrus visible on the right (west) shelving. Leaves appear somewhat dull compared to other crops. Soil moisture data is missing, making assessment difficult. || [wilting] Large hanging plants with long, trailing roots (lik

Vanda OrchidsGemini Vision notes

Hanging baskets visible in the center background. Roots appear white and healthy (indicating good hydration). Foliage is green and upright. || Hanging baskets visible in the center background. Roots appear white and healthy (not brown/rotten). Foliage is green and upright. || Hanging baskets visible in the upper center. Roots appear exposed and healthy; no visible wilting or browning. || Hanging orchids visible in the center. Roots appear long and healthy. No obvious signs of wilting or browning in the infrared view.

pepperGemini Vision notes

Seedlings visible in blue trays on the left-side shelving unit. Plants appear upright and green, with no obvious signs of wilting or yellowing. || Seedlings visible in the blue trays on the left-side shelving unit appear upright and green. || [low_light] Seedlings are visible on the shelving units in the east zone. They appear upright but are small. The 0 lux reading suggests they are relying entirely on supplemental grow lights which are currently active. || [potential nutrient deficiency, low light exposure] Small seedlings visible on the left-hand shelving unit. The leaves appear somewhat pale and thin, which may indicate a lack of light or early-stage nutrient stress. The 0 lux reading suggests the lights are off or the sensor is not active, which is critical for seedlings.

Hourly Pattern

HourTemperatureVPDRH
12:0075.8°F1.13 kPa63.2%
13:0075.5°F1.12 kPa62.8%
14:0078.2°F1.13 kPa65.7%
15:0080.1°F1.17 kPa66.8%
16:0080.3°F1.18 kPa66.8%
17:0075.2°F0.93 kPa68.9%
18:0072.1°F0.78 kPa71.0%
19:0070.0°F0.70 kPa72.0%
20:0067.9°F0.64 kPa72.6%
21:0066.1°F0.57 kPa74.0%
22:0065.0°F0.54 kPa74.3%
23:0063.9°F0.52 kPa74.5%
00:0062.8°F0.50 kPa74.4%
01:0061.7°F0.50 kPa73.8%
02:0061.0°F0.48 kPa73.7%
03:0060.1°F0.47 kPa73.6%
04:0061.0°F0.50 kPa73.0%
05:0061.5°F0.53 kPa71.9%
06:0062.7°F0.60 kPa69.2%
07:0063.9°F0.69 kPa65.9%
08:0066.2°F0.80 kPa63.5%
09:0067.9°F0.98 kPa57.7%
10:0069.7°F1.18 kPa52.2%
11:0071.5°F1.17 kPa55.1%

7-Day Stress Context

DateHeatVPD highCold
2026-10-230.5h6.5h14.7h
2026-10-240.0h7.5h15.8h
2026-10-250.0h8.7h16.2h
2026-10-260.0h0.9h16.5h
2026-10-270.0h1.3h16.6h
2026-10-280.0h4.8h16.7h
2026-10-290.0h6.5h17.0h