October 31, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
9
5
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261031-0016. Resolved 00:19 MDT. |
| Morning planning cycle | 07:29 | SUNRISE | delivery_failed | Delivery recorded without a public plan write. |
| Morning planning cycle | 07:32 | SUNRISE | plan_written | Wrote public plan iris-20261031-0732. Resolved 07:36 MDT. |
| Forecast deviation | 11:08 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261031-1108. Resolved 11:12 MDT. |
| Forecast deviation | 12:09 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261031-1209. Resolved 12:12 MDT. |
| Solar peak planning checkpoint | 12:46 | SOLAR_MAX | acked | Acknowledged: No tunable: solar is 598 W/m² vs forecast peak 432 (385 after the supplied +47 correction, provisional only); live VPD peaked at 1.21 near the 1.22 edge but has eased to 1.15, temp 76.6°F, dew margin 13.4°F, and the afternoon plan remains active. Solar divergence alone is not a continuing indoor miss. Resolved 12:48 MDT. |
| Peak Stress | 14:46 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 14:47 MDT. |
| Decline | 17:00 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 17:02 MDT. |
| Evening planning cycle | 18:00 | SUNSET | plan_written | Wrote public plan iris-20261031-1800. Resolved 18:04 MDT. |
🌅 Morning Cycle (12:19 AM) — iris-20261031-0016
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261030-1802
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:51,“outdoor_rh_min_pct”:74,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:99.5,“notes”:“Cold saturated overnight: outdoor falls to 43°F by dawn, forecast VPD 0.05–0.14 kPa; current indoor dew margin 9.6°F. The prior afternoon moisture-shoulder treatment was not delivered reliably (19 requests missed), so no causal effect is claimed.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-30T22:00:00-06:00”,“end”:“2026-10-31T06:00:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat, damp relay churn, and avoid unnecessary cold-air exchange; leave crop bands unchanged.”},{“kind”:“vpd_low”,“start”:“2026-10-31T02:00:00-06:00”,“end”:“2026-10-31T06:00:00-06:00”,“severity”:“medium”,“mitigation”:“No forecast-only wetting; maintain dew-margin guard and allow only useful, bounded drying exchange… Result: After replacement by iris-20261031-0732, the executed portion of iris-20261031-0016 ended at 07:32 MDT, before its 09:30 waypoint. Its scoped window fraction was 0.300 with plan-window score 63.5; nominal scoped cold stress was 2.09h, while VPD-high/VPD-low and dew-risk were 0.0h. At replacement the fresh climate was 64F, VPD 0.56 kPa, RH 73%, dew margin 9F; observed heat1 was on and vent/fans/misters/fog off. The execution audit showed 28 missed requests and 21 already-at-value, so the intended posture was weakly delivered and causal attribution is poor. Dry-out outcome for Oct 30 was no_episodes with explicit incomplete-coverage limitations; no physical crop or resource result is qualified. Zero dew-risk and no VPD-low are consistent with the hypothesis, but cold stress and delivery failures prevent a stronger grade; no durable lesson extracted. Score: 3/10
Hypothesis
Testing: Operational overnight and dawn protection; no causal experiment. Expected outcome: By 09:30 MDT: dp-risk 0h, VPD-low <1h, dew margin >5°F; avoid forecast-led wetting and unnecessary cold-air exchange. Evidence is diagnostic, not physical crop compliance.
Setpoints
Saturday October 31
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21250000000000002 | Post-midnight: heat priority; no forecast-only wetting, prot |
| 04:00 | hyst 0.21750000000000003 | Pre-dawn low 42–44°F: protect heat; permit wet assist only o |
| 07:00 | hyst 0.21750000000000003 | Sunrise ramp remains saturated/cloudy; avoid precooling and |
| 09:30 | hyst 0.21250000000000002 | Early-day handoff: keep conservative wetting unless live VPD |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.8175000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669 | Post-midnight: heat priority; no forecast-only wetting, prot |
| 04:00 | s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669 | Pre-dawn low 42–44°F: protect heat; permit wet assist only o |
| 07:00 | s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669 | Sunrise ramp remains saturated/cloudy; avoid precooling and |
| 09:30 | s2 1.8325; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 45; wt 1.5333333333333332 | Early-day handoff: keep conservative wetting unless live VPD |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 14 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 285000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.35 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 72 |
| 00:16 | min_fog_on_s | initial 59.25 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 97.5 |
| 00:16 | mister_engage_delay_s | initial 48.75 |
| 00:16 | mister_water_budget_gal | initial 200 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.05 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 5 |
| 00:16 | vent_prefer_temp_delta_f | initial 10 |
| 00:16 | vpd_watch_dwell_s | initial 71.25 |
| 04:00 | cold_vent_guard_delta_f | 14 → 15 |
| 04:00 | dwell_gate_ms | 285000 → 300000 |
| 04:00 | mister_all_delay_s | 97.5 → 102 |
| 04:00 | mister_engage_delay_s | 48.75 → 51 |
| 04:00 | temp_hysteresis | 2.05 → 2.14 |
| 04:00 | vent_prefer_temp_delta_f | 10 → 12 |
| 04:00 | vpd_watch_dwell_s | 71.25 → 75 |
| 09:30 | cold_vent_guard_delta_f | 15 → 14 |
| 09:30 | dwell_gate_ms | 300000 → 285000 |
| 09:30 | min_fog_off_s | 72 → 78 |
| 09:30 | min_fog_on_s | 59.25 → 57 |
| 09:30 | mister_all_delay_s | 102 → 97.5 |
| 09:30 | mister_engage_delay_s | 51 → 48.75 |
| 09:30 | temp_hysteresis | 2.14 → 2.05 |
| 09:30 | vent_prefer_temp_delta_f | 12 → 10 |
| 09:30 | vpd_watch_dwell_s | 75 → 71.25 |
🌅 Morning Cycle (7:36 AM) — iris-20261031-0732
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261031-0016
Previous hypothesis: Cold saturated, overcast dawn: outdoor 42–46°F with RH 86–100% and negligible solar; indoor is 63.7°F, VPD 0.50 kPa, dew margin 8°F, with heat1 observed on. Preserve temperature recovery and avoid unnecessary cold-air exchange; do not wet on forecast alone, but retain bounded moisture assist for live VPD edge excess when dew margin permits. By the 09:30 handoff, target zero dew-risk, VPD-low stress under 1h, and no avoidable relay churn; crop outcomes and resource cost are not attributable from available evidence. Result: Replacement at 11:12 MDT closed the scoped window (fraction 0.147; window planner score 69.9). Contract-2 legacy joint/temp/VPD fractions were 0.8/1.4/99.4%; nominal cold stress 1.54h, VPD-high 0.01h, VPD-low 0h, dew-risk 0h. At handoff, live climate was 73.1F, VPD 0.97 kPa, dew margin 12.3F; heat1 was on and vent/fans/misters/fog were off, consistent with the heat-first/no-forecast-wetting posture. Attribution is weak: audit shows 29 missed and 20 already-at-value requests, and the planned 14:00-17:00 dry-edge test had not begun. Its treatment effect and resource outcome remain untested/unverified; no causal crop claim. Score: 3/10
Hypothesis
Testing: Conditional dry-edge response test: keep dawn heat-focused; open modest band-coupled wet assist only if indoor VPD crosses its high edge with at least 8F dew margin. Expected outcome: Keep dew-risk at 0h and VPD-low stress below 1h; avoid forecast-only wetting and cold-air exchange. If indoor VPD exceeds its high edge 14:00-17:00, bounded wet assist should keep VPD-high stress below 2h without sustained fog; costs remain unverified.
Conditions
63.0°F
48.0%
323.0 W/m²
80.0%
Mostly cloudy, 63F high/46F low. Prior plan self-score 4 vs anchor 1: I gave limited credit for zero dew-risk and a safe handoff, but missed writes and weak window coverage make that benefit poorly attributable; retain skepticism.
Expected stress windows
Keep heat recovery; avoid unnecessary cold-air exchange and forecast-only wetting.
Enable bounded band-coupled wet assist only on live indoor edge excess with dew margin at least 8F.
Parameter rationale
Make first wet assist available near the served VPD high edge without forecast-only dawn misting.
Allow broader mist rotation only if the live high-edge demand persists.
Permit only bounded fog assist if VPD excess persists and dew margin stays healthy.
Setpoints
Saturday October 31
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:32 | hyst 0.21750000000000003 | Dawn: protect heat recovery; no wetting on forecast alone. |
| 10:30 | hyst 0.21750000000000003 | Morning ramp: retain cold-air guard; prepare for measured VP |
| 15:30 | hyst 0.21250000000000002 | Peak VPD forecast: wet assist only for live high-edge demand |
| 17:30 | hyst 0.21750000000000003 | Decline: taper wetting as VPD falls; retain live-edge recove |
| 20:00 | hyst 0.22250000000000003 | Evening: cold humid night ahead; suppress routine wetting, p |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:32 | s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.056; all 1.256; pulse 30; gap 60; wt 1.3 | Dawn: protect heat recovery; no wetting on forecast alone. |
| 10:30 | s2 1.965; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 56.25; wt 1.4 | Morning ramp: retain cold-air guard; prepare for measured VP |
| 15:30 | s2 1.905; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 33.75; gap 41.25; wt 1.6 | Peak VPD forecast: wet assist only for live high-edge demand |
| 17:30 | s2 1.95; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 52.5; wt 1.4333333333333333 | Decline: taper wetting as VPD falls; retain live-edge recove |
| 20:00 | s2 1.995; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.106; all 1.256; pulse 30; gap 60; wt 1.3 | Evening: cold humid night ahead; suppress routine wetting, p |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:32 | band_track_fraction | initial 0 |
| 07:32 | cold_vent_guard_delta_f | initial 12 |
| 07:32 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:32 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 07:32 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 07:32 | dwell_gate_ms | initial 300000 |
| 07:32 | enthalpy_close | initial 1 |
| 07:32 | enthalpy_open | initial -2 |
| 07:32 | fog_escalation_kpa | initial 0.4 |
| 07:32 | heat_hysteresis | initial 1 |
| 07:32 | min_fog_off_s | initial 108 |
| 07:32 | min_fog_on_s | initial 45.75 |
| 07:32 | mist_backoff_s | initial 600 |
| 07:32 | mist_max_closed_vent_s | initial 600 |
| 07:32 | mist_thermal_relief_s | initial 90 |
| 07:32 | mister_all_delay_s | initial 102 |
| 07:32 | mister_engage_delay_s | initial 51 |
| 07:32 | mister_water_budget_gal | initial 100 |
| 07:32 | night_vpd_bias_kpa | initial 0 |
| 07:32 | outdoor_staleness_max_s | initial 600 |
| 07:32 | sw_dwell_gate_enabled | initial 1 |
| 07:32 | sw_fog_closes_vent | initial 1 |
| 07:32 | sw_mister_closes_vent | initial 0 |
| 07:32 | sw_summer_vent_enabled | initial 1 |
| 07:32 | temp_hysteresis | initial 2.14 |
| 07:32 | vent_exchange_fraction | initial 0.3 |
| 07:32 | vent_prefer_dp_delta_f | initial 6 |
| 07:32 | vent_prefer_temp_delta_f | initial 8 |
| 07:32 | vpd_watch_dwell_s | initial 75 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 10:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 10:30 | min_fog_off_s | 108 → 96 |
| 10:30 | min_fog_on_s | 45.75 → 50.25 |
| 10:30 | mister_water_budget_gal | 100 → 120 |
| 15:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 15:30 | dwell_gate_ms | 300000 → 285000 |
| 15:30 | fog_escalation_kpa | 0.35 → 0.25 |
| 15:30 | min_fog_off_s | 96 → 72 |
| 15:30 | min_fog_on_s | 50.25 → 59.25 |
| 15:30 | mister_all_delay_s | 102 → 97.5 |
| 15:30 | mister_engage_delay_s | 51 → 48.75 |
| 15:30 | mister_water_budget_gal | 120 → 140 |
| 15:30 | temp_hysteresis | 2.14 → 2.05 |
| 15:30 | vpd_watch_dwell_s | 75 → 71.25 |
| 17:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 17:30 | dwell_gate_ms | 285000 → 300000 |
| 17:30 | fog_escalation_kpa | 0.25 → 0.35 |
| 17:30 | min_fog_off_s | 72 → 90 |
| 17:30 | min_fog_on_s | 59.25 → 52.5 |
| 17:30 | mister_all_delay_s | 97.5 → 102 |
| 17:30 | mister_engage_delay_s | 48.75 → 51 |
| 17:30 | mister_water_budget_gal | 140 → 120 |
| 17:30 | temp_hysteresis | 2.05 → 2.14 |
| 17:30 | vpd_watch_dwell_s | 71.25 → 75 |
| 20:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.2 |
| 20:00 | dwell_gate_ms | 300000 → 315000 |
| 20:00 | fog_escalation_kpa | 0.35 → 0.45 |
| 20:00 | min_fog_off_s | 90 → 108 |
| 20:00 | min_fog_on_s | 52.5 → 45.75 |
| 20:00 | mister_all_delay_s | 102 → 106.5 |
| 20:00 | mister_engage_delay_s | 51 → 53.25 |
| 20:00 | mister_water_budget_gal | 120 → 100 |
| 20:00 | temp_hysteresis | 2.14 → 2.23 |
| 20:00 | vpd_watch_dwell_s | 75 → 78.75 |
☀️ Midday Cycle (11:12 AM) — iris-20261031-1108
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261031-0016
Result: Replaced at 12:09 MDT after a short 0.040 window fraction: scoped planner score 71.7, nominal cold stress 0.45h, VPD-high/low stress 0h. Current climate was 76.5°F/1.10 kPa with 12.6°F dew margin; controller IDLE, all relays off. The live-edge experiment was not triggered; execution audit showed 18 missed requests and 21 already-at-value. Evidence is insufficient for treatment, resource, or crop attribution; no durable lesson extracted. Score: 4/10
Hypothesis
Testing: Continue the inherited conditional dry-edge test: wet assist only on live VPD edge excess with dew margin >=8F; no forecast-only wetting. Expected outcome: Keep temperature/VPD within dispatcher corridors where achievable, preserve dew margin >=8F, avoid forecast-only wetting and VPD-low stress overnight; if live VPD exceeds its high edge with safe dew margin, retain bounded assist rather than suppressing it. Resource outcomes unverified.
Setpoints
Saturday October 31
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 11:08 | hyst 0.1975 | Clearer than forecast; preserve live-edge-only wet assist an |
| 16:30 | hyst 0.1975 | Keep the conditional test through the afternoon edge; reduce |
| 19:00 | hyst 0.20750000000000002 | Cold, humid evening forecast; retain high-edge fallback but |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 11:08 | s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 33.75; gap 45; wt 1.5666666666666667 | Clearer than forecast; preserve live-edge-only wet assist an |
| 16:30 | s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.5333333333333332 | Keep the conditional test through the afternoon edge; reduce |
| 19:00 | s2 1.92; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.4666666666666666 | Cold, humid evening forecast; retain high-edge fallback but |
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.20750000000000002 | After DST fallback, protect cold dawn; allow moisture respon |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.8325; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.5 | After DST fallback, protect cold dawn; allow moisture respon |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 11:08 | band_track_fraction | initial 0 |
| 11:08 | cold_vent_guard_delta_f | initial 8 |
| 11:08 | cool_stage2_exit_hysteresis_f | initial 1 |
| 11:08 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 11:08 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 11:08 | dwell_gate_ms | initial 240000 |
| 11:08 | enthalpy_close | initial 1 |
| 11:08 | enthalpy_open | initial -2 |
| 11:08 | fog_escalation_kpa | initial 0.25 |
| 11:08 | heat_hysteresis | initial 1 |
| 11:08 | min_fog_off_s | initial 78 |
| 11:08 | min_fog_on_s | initial 57 |
| 11:08 | mist_backoff_s | initial 600 |
| 11:08 | mist_max_closed_vent_s | initial 600 |
| 11:08 | mist_thermal_relief_s | initial 90 |
| 11:08 | mister_all_delay_s | initial 84 |
| 11:08 | mister_engage_delay_s | initial 42 |
| 11:08 | mister_water_budget_gal | initial 120 |
| 11:08 | night_vpd_bias_kpa | initial 0 |
| 11:08 | outdoor_staleness_max_s | initial 600 |
| 11:08 | sw_dwell_gate_enabled | initial 1 |
| 11:08 | sw_fog_closes_vent | initial 1 |
| 11:08 | sw_mister_closes_vent | initial 0 |
| 11:08 | sw_summer_vent_enabled | initial 1 |
| 11:08 | temp_hysteresis | initial 1.78 |
| 11:08 | vent_exchange_fraction | initial 0.3 |
| 11:08 | vent_prefer_dp_delta_f | initial 3 |
| 11:08 | vent_prefer_temp_delta_f | initial 4 |
| 11:08 | vpd_watch_dwell_s | initial 60 |
| 16:30 | fog_escalation_kpa | 0.25 → 0.3 |
| 19:00 | cold_vent_guard_delta_f | 8 → 12 |
| 19:00 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 19:00 | dwell_gate_ms | 240000 → 270000 |
| 19:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 19:00 | mister_all_delay_s | 84 → 93 |
| 19:00 | mister_engage_delay_s | 42 → 46.5 |
| 19:00 | temp_hysteresis | 1.78 → 1.96 |
| 19:00 | vent_prefer_temp_delta_f | 4 → 8 |
| 19:00 | vpd_watch_dwell_s | 60 → 67.5 |
☀️ Midday Cycle (12:12 PM) — iris-20261031-1209
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261031-0016
Result: Plan iris-20261031-1209 governed 12:12–18:04 and was replaced. Oct 31 partial contract-2 score was 70.9 (7-day mean 71.3); legacy binary temp/VPD fractions were 32.6%/74.5%, with 15.58 nominal stress hours (cold 11.3h, VPD-high 4.28h, heat/VPD-low 0h). Minimum dew margin was 7.4°F and dp-risk 0h. Resource values are null and resource weight was 0; coverage and physical crop-band evidence are unqualified. The scoped plan-window score was 71.1. Avoiding forecast-only wetting was consistent with no VPD-low stress, but the conditional response and its effect are unverified: 18 requests were missed and VPD-high stress persisted. Oct 30 realized dryout returned no_episodes, with incomplete daylight coverage limitations and safety status pending; this does not prove zero admission. No causal crop/resource outcome or durable lesson. Score: 4/10
Hypothesis
Testing: Continue the inherited conditional dry-edge test: wet assist only on live VPD edge excess with dew margin >=8F; no forecast-only wetting. Expected outcome: Do not alter crop corridors or react to cloud forecast alone; preserve dew margin >=8°F and avoid scheduled wetting overnight. Keep bounded assist available only for live VPD edge excess with safe dew margin; resource and crop outcomes remain unverified.
Setpoints
Saturday October 31
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:09 | hyst 0.19749999999999998 | Treat clearing as a forecast miss; retain bounded live-edge |
| 18:00 | hyst 0.19749999999999998 | Cold humid night ahead; avoid proactive wetting while preser |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:09 | s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332 | Treat clearing as a forecast miss; retain bounded live-edge |
| 18:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332 | Cold humid night ahead; avoid proactive wetting while preser |
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.19749999999999998 | Dawn forecast is saturated and VPD-low; retain heat/dew safe |
| 14:00 | hyst 0.19749999999999998 | Cool cloudy day; keep moderate solar preparation and wet ass |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332 | Dawn forecast is saturated and VPD-low; retain heat/dew safe |
| 14:00 | s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332 | Cool cloudy day; keep moderate solar preparation and wet ass |
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.19749999999999998 | Windy cool forecast with limited solar; keep conservative we |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332 | Windy cool forecast with limited solar; keep conservative we |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.19749999999999998 | Clearer dry dawn possible; open bounded assist only on measu |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.8025000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 33.75; gap 37.5; wt 1.6333333333333333 | Clearer dry dawn possible; open bounded assist only on measu |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 12:09 | band_track_fraction | initial 0 |
| 12:09 | cold_vent_guard_delta_f | initial 8 |
| 12:09 | cool_stage2_exit_hysteresis_f | initial 1 |
| 12:09 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 12:09 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 12:09 | dwell_gate_ms | initial 240000 |
| 12:09 | enthalpy_close | initial 1 |
| 12:09 | enthalpy_open | initial -2 |
| 12:09 | fog_escalation_kpa | initial 0.4 |
| 12:09 | heat_hysteresis | initial 1 |
| 12:09 | min_fog_off_s | initial 78 |
| 12:09 | min_fog_on_s | initial 57 |
| 12:09 | mist_backoff_s | initial 600 |
| 12:09 | mist_max_closed_vent_s | initial 600 |
| 12:09 | mist_thermal_relief_s | initial 90 |
| 12:09 | mister_all_delay_s | initial 84 |
| 12:09 | mister_engage_delay_s | initial 42 |
| 12:09 | mister_water_budget_gal | initial 300 |
| 12:09 | night_vpd_bias_kpa | initial 0 |
| 12:09 | outdoor_staleness_max_s | initial 600 |
| 12:09 | sw_dwell_gate_enabled | initial 1 |
| 12:09 | sw_fog_closes_vent | initial 1 |
| 12:09 | sw_mister_closes_vent | initial 0 |
| 12:09 | sw_summer_vent_enabled | initial 1 |
| 12:09 | temp_hysteresis | initial 1.78 |
| 12:09 | vent_exchange_fraction | initial 0.3 |
| 12:09 | vent_prefer_dp_delta_f | initial 3 |
| 12:09 | vent_prefer_temp_delta_f | initial 4 |
| 12:09 | vpd_watch_dwell_s | initial 60 |
| 18:00 | fog_escalation_kpa | 0.4 → 0.45 |
| 14:00 | fog_escalation_kpa | 0.45 → 0.4 |
| 07:00 | fog_escalation_kpa | 0.4 → 0.45 |
| 07:00 | fog_escalation_kpa | 0.45 → 0.3 |
| 07:00 | min_fog_off_s | 78 → 66 |
| 07:00 | min_fog_on_s | 57 → 61.5 |
🌆 Evening Cycle (6:04 PM) — iris-20261031-1800
validated
2/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261031-1108
Previous hypothesis: Cloud-cover deviation is an outdoor forecast miss/local clearing, not equipment failure: observed cloud is 0% with 348 W/m² solar, while greenhouse air is 73.1°F/0.97 kPa with 12.3°F dew margin and low zone spread; temperature and VPD remain within the latest dispatcher corridors. Keep the existing conditional dry-edge experiment: wet assist only on live VPD edge excess with dew margin >=8°F; do not wet on the cloud forecast alone. Preserve heat-first/cold-night posture and taper wet duty for the forecast cold, very humid night and Sunday dawn. Historical cloud calibration has no paired samples; temp/VPD calibration is modest and does not justify an offset. Result: Oct 31 scorecard: planner_score 73.5, contract-2 legacy temp/VPD fractions 25.5%/81.2%; nominal stress 21.26h (cold 16.98h, VPD-high 4.28h, VPD-low 0), dew-risk 0h, minimum dew margin 7.4°F. Costs are unavailable; total water was 2 gal vs 7-day average 166 gal. For this plan’s scoped 18:04–midnight window, score 63.5, cold stress 1.77h, VPD-high/low 0h; dryout query returned no episodes but safety is pending and daylight coverage is incomplete. These results are consistent with avoiding wetting and dew risk, but do not establish causal benefit; the daily bottleneck was cold/temperature, and write delivery was weak (31 missed requests per context). Score: 2/10
Hypothesis
Testing: Directional only: test conservative overnight exchange against cold stress while preserving a live-edge moisture response; no crop or resource causality claimed. Expected outcome: Keep dp_risk_hours at 0 and minimum dew margin above 5°F; reduce cold stress versus today’s 11.3h without forecast-only wetting. Resource and physical crop outcomes remain unverified.
Conditions
51.0°F
77.0%
0.0 W/m²
85.0%
Cold saturated night: forecast falls from 51°F to 40°F, RH rises to 100%, and outdoor VPD approaches zero. Indoors is 73.2°F/0.77 kPa with 9.4°F dew margin; heat1 is on.
Expected stress windows
Use longer thermal lead and require a stronger outdoor advantage for exchange; penalize relay churn.
No forecast-only wetting; keep low mist duty and an 8°F dew-margin floor, with live-edge response retained.
Parameter rationale
Avoid forecast-only wetting while retaining bounded response to measured VPD-high excess.
Prevent routine all-zone misting unless live VPD rises materially above the served edge.
Reduce avoidable cold-air exchange during heating and preserve dew margin above 5°F.
Setpoints
Saturday October 31
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | hyst 0.2175 | Evening settle: preserve heat, require a stronger outdoor ad |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | s2 1.8900000000000001; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 37.5; wt 1.5666666666666667 | Evening settle: preserve heat, require a stronger outdoor ad |
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.22249999999999998 | Midnight: colder saturated air; prioritize stable heat and d |
| 05:00 | hyst 0.22249999999999998 | Pre-dawn: forecast minimum is 40°F with saturated air; exten |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.8900000000000001; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 37.5; wt 1.5333333333333332 | Midnight: colder saturated air; prioritize stable heat and d |
| 05:00 | s2 1.875; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 33.75; wt 1.5666666666666667 | Pre-dawn: forecast minimum is 40°F with saturated air; exten |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 18:00 | band_track_fraction | initial 0 |
| 18:00 | cold_vent_guard_delta_f | initial 12 |
| 18:00 | cool_stage2_exit_hysteresis_f | initial 1 |
| 18:00 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 18:00 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 18:00 | dwell_gate_ms | initial 300000 |
| 18:00 | enthalpy_close | initial 1 |
| 18:00 | enthalpy_open | initial -2 |
| 18:00 | fog_escalation_kpa | initial 0.45 |
| 18:00 | heat_hysteresis | initial 1 |
| 18:00 | min_fog_off_s | initial 66 |
| 18:00 | min_fog_on_s | initial 61.5 |
| 18:00 | mist_backoff_s | initial 600 |
| 18:00 | mist_max_closed_vent_s | initial 600 |
| 18:00 | mist_thermal_relief_s | initial 90 |
| 18:00 | mister_all_delay_s | initial 102 |
| 18:00 | mister_engage_delay_s | initial 51 |
| 18:00 | mister_water_budget_gal | initial 150 |
| 18:00 | night_vpd_bias_kpa | initial 0 |
| 18:00 | outdoor_staleness_max_s | initial 600 |
| 18:00 | sw_dwell_gate_enabled | initial 1 |
| 18:00 | sw_fog_closes_vent | initial 1 |
| 18:00 | sw_mister_closes_vent | initial 0 |
| 18:00 | sw_summer_vent_enabled | initial 1 |
| 18:00 | temp_hysteresis | initial 2.14 |
| 18:00 | vent_exchange_fraction | initial 0.3 |
| 18:00 | vent_prefer_dp_delta_f | initial 8 |
| 18:00 | vent_prefer_temp_delta_f | initial 8 |
| 18:00 | vpd_watch_dwell_s | initial 75 |
| 00:00 | cold_vent_guard_delta_f | 12 → 14 |
| 00:00 | dwell_gate_ms | 300000 → 315000 |
| 00:00 | fog_escalation_kpa | 0.45 → 0.5 |
| 00:00 | mister_all_delay_s | 102 → 106.5 |
| 00:00 | mister_engage_delay_s | 51 → 53.25 |
| 00:00 | temp_hysteresis | 2.14 → 2.23 |
| 00:00 | vent_prefer_temp_delta_f | 8 → 10 |
| 00:00 | vpd_watch_dwell_s | 75 → 78.75 |
| 05:00 | min_fog_off_s | 66 → 60 |
| 05:00 | min_fog_on_s | 61.5 → 63.75 |
End-of-Day Summary
Climate
61.3–83.1°F; avg 68.6°F
0.44–1.32 kPa; avg 0.71 kPa
59.8–76.5%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 4.3h
- Cold stress (<55°F): 17.0h
Economics
Not available
USD 0.51
USD 0.010
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 2 min | Fogger runtime. |
| Heat 1 electric | 1280 min | Electric heater runtime. |
| Heat 2 gas | 49 min | Gas heater runtime. |
| Grow lights | 888 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 2 gal
- Mister: 2 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 73% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 83% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 65% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Hanging plants in the west zone appear upright with turgid leaves. Roots are visible and appear white and healthy. No obvious wilting or yellowing observed in the infrared spectrum. || Large potted plant visible in the background (upper center/right); canopy appears full, no visible leaf drop or structural damage. || Large potted plant with broad green leaves located in the central floor area. Foliage appears healthy and turgid with no visible signs of yellowing or pest damage. || Large potted plant with exposed roots (likely an orchid or similar epiphyte) located in the center-left area. Foliage is vibrant green and turgid. Roots appear white and healthy. || Large potted tree visible on the left side. Leaves appear green, though the specific variety is difficult to confirm from this distance. || Visible in the left-hand shelving area. Foliage appears dense and upright. No visible signs of wilting or leaf drop. The bright white appearance is consistent with IR illumination of healthy g
Hanging baskets visible in the center background. Roots appear exposed and healthy (white/grey), typical for Vanda. Leaves are green and turgid. || Hanging baskets visible in the center background. Roots appear white and healthy, indicating good hydration and no immediate stress. || Hanging baskets visible in the upper center of the frame. Roots appear exposed and healthy; no visible wilting or leaf discoloration. || Hanging baskets visible in the upper center; roots appear dense and healthy, no obvious signs of wilting or discoloration.
Located on the right-hand shelving units near the hydroponic piping. Plants appear small and upright. While specific seedling details are difficult to resolve in IR, the general structure suggests healthy development without obvious collapse or damage. || Seedlings visible in blue trays on the left shelving unit. Plants appear upright and green, though specific individual health is difficult to assess at this distance. || Seedlings visible in blue trays on the left shelving unit. Plants appear upright and green, though specific individual health is hard to distinguish at this distance. || [low_light, potential_crowding] Seedlings on the east shelving unit are small and difficult to distinguish individually. The 0 lux reading suggests the grow lights for this zone may be off or the sensor is not capturing the specific light source, which is critical for seedling development.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 76.3°F | 1.04 kPa | 66.5% |
| 13:00 | 76.2°F | 1.03 kPa | 66.7% |
| 14:00 | 77.1°F | 1.15 kPa | 63.9% |
| 15:00 | 79.9°F | 1.17 kPa | 66.5% |
| 16:00 | 79.9°F | 1.00 kPa | 71.5% |
| 17:00 | 74.7°F | 0.84 kPa | 71.6% |
| 18:00 | 71.6°F | 0.73 kPa | 72.3% |
| 19:00 | 71.1°F | 0.74 kPa | 71.4% |
| 20:00 | 68.8°F | 0.68 kPa | 71.9% |
| 21:00 | 66.7°F | 0.59 kPa | 73.7% |
| 22:00 | 65.3°F | 0.54 kPa | 74.7% |
| 23:00 | 64.2°F | 0.51 kPa | 75.1% |
| 00:00 | 63.6°F | 0.50 kPa | 75.4% |
| 01:00 | 63.0°F | 0.48 kPa | 75.5% |
| 02:00 | 62.5°F | 0.47 kPa | 75.6% |
| 03:00 | 62.2°F | 0.47 kPa | 75.5% |
| 04:00 | 61.9°F | 0.46 kPa | 75.6% |
| 05:00 | 61.5°F | 0.46 kPa | 75.7% |
| 06:00 | 61.6°F | 0.46 kPa | 75.7% |
| 07:00 | 64.4°F | 0.57 kPa | 72.6% |
| 08:00 | 66.1°F | 0.64 kPa | 71.1% |
| 09:00 | 67.4°F | 0.70 kPa | 69.5% |
| 10:00 | 70.8°F | 0.84 kPa | 67.5% |
| 11:00 | 72.7°F | 0.94 kPa | 65.8% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-25 | 0.0h | 8.7h | 16.2h |
| 2026-10-26 | 0.0h | 0.9h | 16.5h |
| 2026-10-27 | 0.0h | 1.3h | 16.6h |
| 2026-10-28 | 0.0h | 4.8h | 16.7h |
| 2026-10-29 | 0.0h | 6.5h | 17.0h |
| 2026-10-30 | 0.0h | 4.2h | 16.7h |
| 2026-10-31 | 0.0h | 4.3h | 17.0h |