October 31, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

9

Plan writes

5

No-change acknowledgements

1

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:16MIDNIGHTplan_writtenWrote public plan iris-20261031-0016. Resolved 00:19 MDT.
Morning planning cycle07:29SUNRISEdelivery_failedDelivery recorded without a public plan write.
Morning planning cycle07:32SUNRISEplan_writtenWrote public plan iris-20261031-0732. Resolved 07:36 MDT.
Forecast deviation11:08FORECAST_DEVIATIONplan_writtenWrote public plan iris-20261031-1108. Resolved 11:12 MDT.
Forecast deviation12:09FORECAST_DEVIATIONplan_writtenWrote public plan iris-20261031-1209. Resolved 12:12 MDT.
Solar peak planning checkpoint12:46SOLAR_MAXackedAcknowledged: No tunable: solar is 598 W/m² vs forecast peak 432 (385 after the supplied +47 correction, provisional only); live VPD peaked at 1.21 near the 1.22 edge but has eased to 1.15, temp 76.6°F, dew margin 13.4°F, and the afternoon plan remains active. Solar divergence alone is not a continuing indoor miss. Resolved 12:48 MDT.
Peak Stress14:46TRANSITIONaction_completedDelivery recorded without a public plan write. Resolved 14:47 MDT.
Decline17:00TRANSITIONaction_completedDelivery recorded without a public plan write. Resolved 17:02 MDT.
Evening planning cycle18:00SUNSETplan_writtenWrote public plan iris-20261031-1800. Resolved 18:04 MDT.

🌅 Morning Cycle (12:19 AM) — iris-20261031-0016

Status

validated

Outcome score

3/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261030-1802

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:51,“outdoor_rh_min_pct”:74,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:99.5,“notes”:“Cold saturated overnight: outdoor falls to 43°F by dawn, forecast VPD 0.05–0.14 kPa; current indoor dew margin 9.6°F. The prior afternoon moisture-shoulder treatment was not delivered reliably (19 requests missed), so no causal effect is claimed.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-30T22:00:00-06:00”,“end”:“2026-10-31T06:00:00-06:00”,“severity”:“high”,“mitigation”:“Preserve heat, damp relay churn, and avoid unnecessary cold-air exchange; leave crop bands unchanged.”},{“kind”:“vpd_low”,“start”:“2026-10-31T02:00:00-06:00”,“end”:“2026-10-31T06:00:00-06:00”,“severity”:“medium”,“mitigation”:“No forecast-only wetting; maintain dew-margin guard and allow only useful, bounded drying exchange… Result: After replacement by iris-20261031-0732, the executed portion of iris-20261031-0016 ended at 07:32 MDT, before its 09:30 waypoint. Its scoped window fraction was 0.300 with plan-window score 63.5; nominal scoped cold stress was 2.09h, while VPD-high/VPD-low and dew-risk were 0.0h. At replacement the fresh climate was 64F, VPD 0.56 kPa, RH 73%, dew margin 9F; observed heat1 was on and vent/fans/misters/fog off. The execution audit showed 28 missed requests and 21 already-at-value, so the intended posture was weakly delivered and causal attribution is poor. Dry-out outcome for Oct 30 was no_episodes with explicit incomplete-coverage limitations; no physical crop or resource result is qualified. Zero dew-risk and no VPD-low are consistent with the hypothesis, but cold stress and delivery failures prevent a stronger grade; no durable lesson extracted. Score: 3/10

Hypothesis

Testing: Operational overnight and dawn protection; no causal experiment. Expected outcome: By 09:30 MDT: dp-risk 0h, VPD-low <1h, dew margin >5°F; avoid forecast-led wetting and unnecessary cold-air exchange. Evidence is diagnostic, not physical crop compliance.

Setpoints

Saturday October 31

Primary crop-band changes:

TimeValuesNote
00:16hyst 0.21250000000000002Post-midnight: heat priority; no forecast-only wetting, prot
04:00hyst 0.21750000000000003Pre-dawn low 42–44°F: protect heat; permit wet assist only o
07:00hyst 0.21750000000000003Sunrise ramp remains saturated/cloudy; avoid precooling and
09:30hyst 0.21250000000000002Early-day handoff: keep conservative wetting unless live VPD

Tactical tunable changes:

TimeValuesNote
00:16s2 1.8175000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669Post-midnight: heat priority; no forecast-only wetting, prot
04:00s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669Pre-dawn low 42–44°F: protect heat; permit wet assist only o
07:00s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 41.25; wt 1.5666666666666669Sunrise ramp remains saturated/cloudy; avoid precooling and
09:30s2 1.8325; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 45; wt 1.5333333333333332Early-day handoff: keep conservative wetting unless live VPD

Changed secondary parameters:

TimeParameterChange
00:16band_track_fractioninitial 0
00:16cold_vent_guard_delta_finitial 14
00:16cool_stage2_exit_hysteresis_finitial 1
00:16direct_wet_stress_min_dew_margin_finitial 8
00:16direct_wet_stress_vpd_margin_kpainitial 0.05
00:16dwell_gate_msinitial 285000
00:16enthalpy_closeinitial 1
00:16enthalpy_openinitial -2
00:16fog_escalation_kpainitial 0.35
00:16heat_hysteresisinitial 1
00:16min_fog_off_sinitial 72
00:16min_fog_on_sinitial 59.25
00:16mist_backoff_sinitial 600
00:16mist_max_closed_vent_sinitial 600
00:16mist_thermal_relief_sinitial 90
00:16mister_all_delay_sinitial 97.5
00:16mister_engage_delay_sinitial 48.75
00:16mister_water_budget_galinitial 200
00:16night_vpd_bias_kpainitial 0
00:16outdoor_staleness_max_sinitial 600
00:16sw_dwell_gate_enabledinitial 1
00:16sw_fog_closes_ventinitial 1
00:16sw_mister_closes_ventinitial 0
00:16sw_summer_vent_enabledinitial 1
00:16temp_hysteresisinitial 2.05
00:16vent_exchange_fractioninitial 0.3
00:16vent_prefer_dp_delta_finitial 5
00:16vent_prefer_temp_delta_finitial 10
00:16vpd_watch_dwell_sinitial 71.25
04:00cold_vent_guard_delta_f14 → 15
04:00dwell_gate_ms285000 → 300000
04:00mister_all_delay_s97.5 → 102
04:00mister_engage_delay_s48.75 → 51
04:00temp_hysteresis2.05 → 2.14
04:00vent_prefer_temp_delta_f10 → 12
04:00vpd_watch_dwell_s71.25 → 75
09:30cold_vent_guard_delta_f15 → 14
09:30dwell_gate_ms300000 → 285000
09:30min_fog_off_s72 → 78
09:30min_fog_on_s59.25 → 57
09:30mister_all_delay_s102 → 97.5
09:30mister_engage_delay_s51 → 48.75
09:30temp_hysteresis2.14 → 2.05
09:30vent_prefer_temp_delta_f12 → 10
09:30vpd_watch_dwell_s75 → 71.25

🌅 Morning Cycle (7:36 AM) — iris-20261031-0732

Status

validated

Outcome score

3/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261031-0016

Previous hypothesis: Cold saturated, overcast dawn: outdoor 42–46°F with RH 86–100% and negligible solar; indoor is 63.7°F, VPD 0.50 kPa, dew margin 8°F, with heat1 observed on. Preserve temperature recovery and avoid unnecessary cold-air exchange; do not wet on forecast alone, but retain bounded moisture assist for live VPD edge excess when dew margin permits. By the 09:30 handoff, target zero dew-risk, VPD-low stress under 1h, and no avoidable relay churn; crop outcomes and resource cost are not attributable from available evidence. Result: Replacement at 11:12 MDT closed the scoped window (fraction 0.147; window planner score 69.9). Contract-2 legacy joint/temp/VPD fractions were 0.8/1.4/99.4%; nominal cold stress 1.54h, VPD-high 0.01h, VPD-low 0h, dew-risk 0h. At handoff, live climate was 73.1F, VPD 0.97 kPa, dew margin 12.3F; heat1 was on and vent/fans/misters/fog were off, consistent with the heat-first/no-forecast-wetting posture. Attribution is weak: audit shows 29 missed and 20 already-at-value requests, and the planned 14:00-17:00 dry-edge test had not begun. Its treatment effect and resource outcome remain untested/unverified; no causal crop claim. Score: 3/10

Hypothesis

Testing: Conditional dry-edge response test: keep dawn heat-focused; open modest band-coupled wet assist only if indoor VPD crosses its high edge with at least 8F dew margin. Expected outcome: Keep dew-risk at 0h and VPD-low stress below 1h; avoid forecast-only wetting and cold-air exchange. If indoor VPD exceeds its high edge 14:00-17:00, bounded wet assist should keep VPD-high stress below 2h without sustained fog; costs remain unverified.

Conditions

Outdoor peak

63.0°F

RH minimum

48.0%

Solar peak

323.0 W/m²

Cloud average

80.0%

Mostly cloudy, 63F high/46F low. Prior plan self-score 4 vs anchor 1: I gave limited credit for zero dew-risk and a safe handoff, but missed writes and weak window coverage make that benefit poorly attributable; retain skepticism.

Expected stress windows

coldmedium · 2026-10-31T07:32:00-06:00 to 2026-10-31T10:30:00-06:00

Keep heat recovery; avoid unnecessary cold-air exchange and forecast-only wetting.

vpd_highmedium · 2026-10-31T14:00:00-06:00 to 2026-10-31T17:00:00-06:00

Enable bounded band-coupled wet assist only on live indoor edge excess with dew margin at least 8F.

Parameter rationale

mister_engage_kpa1.6 → 0.95; Outdoor VPD rises from 0.01 at dawn to 1.04 kPa near 16:00; require live indoor confirmation.

Make first wet assist available near the served VPD high edge without forecast-only dawn misting.

mister_all_kpa1.9 → 1.15; Modest afternoon drying peak; indoor readings and dew margin remain the gating evidence.

Allow broader mist rotation only if the live high-edge demand persists.

fog_escalation_kpa0.4 → 0.25; VPD peaks near 1.04 kPa with no strong heat load; fog window and RH gates remain active.

Permit only bounded fog assist if VPD excess persists and dew margin stays healthy.

Setpoints

Saturday October 31

Primary crop-band changes:

TimeValuesNote
07:32hyst 0.21750000000000003Dawn: protect heat recovery; no wetting on forecast alone.
10:30hyst 0.21750000000000003Morning ramp: retain cold-air guard; prepare for measured VP
15:30hyst 0.21250000000000002Peak VPD forecast: wet assist only for live high-edge demand
17:30hyst 0.21750000000000003Decline: taper wetting as VPD falls; retain live-edge recove
20:00hyst 0.22250000000000003Evening: cold humid night ahead; suppress routine wetting, p

Tactical tunable changes:

TimeValuesNote
07:32s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.056; all 1.256; pulse 30; gap 60; wt 1.3Dawn: protect heat recovery; no wetting on forecast alone.
10:30s2 1.965; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 56.25; wt 1.4Morning ramp: retain cold-air guard; prepare for measured VP
15:30s2 1.905; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 33.75; gap 41.25; wt 1.6Peak VPD forecast: wet assist only for live high-edge demand
17:30s2 1.95; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 52.5; wt 1.4333333333333333Decline: taper wetting as VPD falls; retain live-edge recove
20:00s2 1.995; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.106; all 1.256; pulse 30; gap 60; wt 1.3Evening: cold humid night ahead; suppress routine wetting, p

Changed secondary parameters:

TimeParameterChange
07:32band_track_fractioninitial 0
07:32cold_vent_guard_delta_finitial 12
07:32cool_stage2_exit_hysteresis_finitial 1
07:32direct_wet_stress_min_dew_margin_finitial 8
07:32direct_wet_stress_vpd_margin_kpainitial 0.15
07:32dwell_gate_msinitial 300000
07:32enthalpy_closeinitial 1
07:32enthalpy_openinitial -2
07:32fog_escalation_kpainitial 0.4
07:32heat_hysteresisinitial 1
07:32min_fog_off_sinitial 108
07:32min_fog_on_sinitial 45.75
07:32mist_backoff_sinitial 600
07:32mist_max_closed_vent_sinitial 600
07:32mist_thermal_relief_sinitial 90
07:32mister_all_delay_sinitial 102
07:32mister_engage_delay_sinitial 51
07:32mister_water_budget_galinitial 100
07:32night_vpd_bias_kpainitial 0
07:32outdoor_staleness_max_sinitial 600
07:32sw_dwell_gate_enabledinitial 1
07:32sw_fog_closes_ventinitial 1
07:32sw_mister_closes_ventinitial 0
07:32sw_summer_vent_enabledinitial 1
07:32temp_hysteresisinitial 2.14
07:32vent_exchange_fractioninitial 0.3
07:32vent_prefer_dp_delta_finitial 6
07:32vent_prefer_temp_delta_finitial 8
07:32vpd_watch_dwell_sinitial 75
10:30direct_wet_stress_vpd_margin_kpa0.15 → 0.1
10:30fog_escalation_kpa0.4 → 0.35
10:30min_fog_off_s108 → 96
10:30min_fog_on_s45.75 → 50.25
10:30mister_water_budget_gal100 → 120
15:30direct_wet_stress_vpd_margin_kpa0.1 → 0.05
15:30dwell_gate_ms300000 → 285000
15:30fog_escalation_kpa0.35 → 0.25
15:30min_fog_off_s96 → 72
15:30min_fog_on_s50.25 → 59.25
15:30mister_all_delay_s102 → 97.5
15:30mister_engage_delay_s51 → 48.75
15:30mister_water_budget_gal120 → 140
15:30temp_hysteresis2.14 → 2.05
15:30vpd_watch_dwell_s75 → 71.25
17:30direct_wet_stress_vpd_margin_kpa0.05 → 0.1
17:30dwell_gate_ms285000 → 300000
17:30fog_escalation_kpa0.25 → 0.35
17:30min_fog_off_s72 → 90
17:30min_fog_on_s59.25 → 52.5
17:30mister_all_delay_s97.5 → 102
17:30mister_engage_delay_s48.75 → 51
17:30mister_water_budget_gal140 → 120
17:30temp_hysteresis2.05 → 2.14
17:30vpd_watch_dwell_s71.25 → 75
20:00direct_wet_stress_vpd_margin_kpa0.1 → 0.2
20:00dwell_gate_ms300000 → 315000
20:00fog_escalation_kpa0.35 → 0.45
20:00min_fog_off_s90 → 108
20:00min_fog_on_s52.5 → 45.75
20:00mister_all_delay_s102 → 106.5
20:00mister_engage_delay_s51 → 53.25
20:00mister_water_budget_gal120 → 100
20:00temp_hysteresis2.14 → 2.23
20:00vpd_watch_dwell_s75 → 78.75

☀️ Midday Cycle (11:12 AM) — iris-20261031-1108

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261031-0016

Result: Replaced at 12:09 MDT after a short 0.040 window fraction: scoped planner score 71.7, nominal cold stress 0.45h, VPD-high/low stress 0h. Current climate was 76.5°F/1.10 kPa with 12.6°F dew margin; controller IDLE, all relays off. The live-edge experiment was not triggered; execution audit showed 18 missed requests and 21 already-at-value. Evidence is insufficient for treatment, resource, or crop attribution; no durable lesson extracted. Score: 4/10

Hypothesis

Testing: Continue the inherited conditional dry-edge test: wet assist only on live VPD edge excess with dew margin >=8F; no forecast-only wetting. Expected outcome: Keep temperature/VPD within dispatcher corridors where achievable, preserve dew margin >=8F, avoid forecast-only wetting and VPD-low stress overnight; if live VPD exceeds its high edge with safe dew margin, retain bounded assist rather than suppressing it. Resource outcomes unverified.

Setpoints

Saturday October 31

Primary crop-band changes:

TimeValuesNote
11:08hyst 0.1975Clearer than forecast; preserve live-edge-only wet assist an
16:30hyst 0.1975Keep the conditional test through the afternoon edge; reduce
19:00hyst 0.20750000000000002Cold, humid evening forecast; retain high-edge fallback but

Tactical tunable changes:

TimeValuesNote
11:08s2 1.745; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 33.75; gap 45; wt 1.5666666666666667Clearer than forecast; preserve live-edge-only wet assist an
16:30s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.5333333333333332Keep the conditional test through the afternoon edge; reduce
19:00s2 1.92; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.4666666666666666Cold, humid evening forecast; retain high-edge fallback but

Sunday November 01

Primary crop-band changes:

TimeValuesNote
07:00hyst 0.20750000000000002After DST fallback, protect cold dawn; allow moisture respon

Tactical tunable changes:

TimeValuesNote
07:00s2 1.8325; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1.195; all 1.395; pulse 30; gap 45; wt 1.5After DST fallback, protect cold dawn; allow moisture respon

Changed secondary parameters:

TimeParameterChange
11:08band_track_fractioninitial 0
11:08cold_vent_guard_delta_finitial 8
11:08cool_stage2_exit_hysteresis_finitial 1
11:08direct_wet_stress_min_dew_margin_finitial 8
11:08direct_wet_stress_vpd_margin_kpainitial 0.05
11:08dwell_gate_msinitial 240000
11:08enthalpy_closeinitial 1
11:08enthalpy_openinitial -2
11:08fog_escalation_kpainitial 0.25
11:08heat_hysteresisinitial 1
11:08min_fog_off_sinitial 78
11:08min_fog_on_sinitial 57
11:08mist_backoff_sinitial 600
11:08mist_max_closed_vent_sinitial 600
11:08mist_thermal_relief_sinitial 90
11:08mister_all_delay_sinitial 84
11:08mister_engage_delay_sinitial 42
11:08mister_water_budget_galinitial 120
11:08night_vpd_bias_kpainitial 0
11:08outdoor_staleness_max_sinitial 600
11:08sw_dwell_gate_enabledinitial 1
11:08sw_fog_closes_ventinitial 1
11:08sw_mister_closes_ventinitial 0
11:08sw_summer_vent_enabledinitial 1
11:08temp_hysteresisinitial 1.78
11:08vent_exchange_fractioninitial 0.3
11:08vent_prefer_dp_delta_finitial 3
11:08vent_prefer_temp_delta_finitial 4
11:08vpd_watch_dwell_sinitial 60
16:30fog_escalation_kpa0.25 → 0.3
19:00cold_vent_guard_delta_f8 → 12
19:00direct_wet_stress_min_dew_margin_f8 → 10
19:00dwell_gate_ms240000 → 270000
19:00fog_escalation_kpa0.3 → 0.4
19:00mister_all_delay_s84 → 93
19:00mister_engage_delay_s42 → 46.5
19:00temp_hysteresis1.78 → 1.96
19:00vent_prefer_temp_delta_f4 → 8
19:00vpd_watch_dwell_s60 → 67.5

☀️ Midday Cycle (12:12 PM) — iris-20261031-1209

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261031-0016

Result: Plan iris-20261031-1209 governed 12:12–18:04 and was replaced. Oct 31 partial contract-2 score was 70.9 (7-day mean 71.3); legacy binary temp/VPD fractions were 32.6%/74.5%, with 15.58 nominal stress hours (cold 11.3h, VPD-high 4.28h, heat/VPD-low 0h). Minimum dew margin was 7.4°F and dp-risk 0h. Resource values are null and resource weight was 0; coverage and physical crop-band evidence are unqualified. The scoped plan-window score was 71.1. Avoiding forecast-only wetting was consistent with no VPD-low stress, but the conditional response and its effect are unverified: 18 requests were missed and VPD-high stress persisted. Oct 30 realized dryout returned no_episodes, with incomplete daylight coverage limitations and safety status pending; this does not prove zero admission. No causal crop/resource outcome or durable lesson. Score: 4/10

Hypothesis

Testing: Continue the inherited conditional dry-edge test: wet assist only on live VPD edge excess with dew margin >=8F; no forecast-only wetting. Expected outcome: Do not alter crop corridors or react to cloud forecast alone; preserve dew margin >=8°F and avoid scheduled wetting overnight. Keep bounded assist available only for live VPD edge excess with safe dew margin; resource and crop outcomes remain unverified.

Setpoints

Saturday October 31

Primary crop-band changes:

TimeValuesNote
12:09hyst 0.19749999999999998Treat clearing as a forecast miss; retain bounded live-edge
18:00hyst 0.19749999999999998Cold humid night ahead; avoid proactive wetting while preser

Tactical tunable changes:

TimeValuesNote
12:09s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332Treat clearing as a forecast miss; retain bounded live-edge
18:00s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332Cold humid night ahead; avoid proactive wetting while preser

Sunday November 01

Primary crop-band changes:

TimeValuesNote
07:00hyst 0.19749999999999998Dawn forecast is saturated and VPD-low; retain heat/dew safe
14:00hyst 0.19749999999999998Cool cloudy day; keep moderate solar preparation and wet ass

Tactical tunable changes:

TimeValuesNote
07:00s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332Dawn forecast is saturated and VPD-low; retain heat/dew safe
14:00s2 1.8325; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332Cool cloudy day; keep moderate solar preparation and wet ass

Monday November 02

Primary crop-band changes:

TimeValuesNote
07:00hyst 0.19749999999999998Windy cool forecast with limited solar; keep conservative we

Tactical tunable changes:

TimeValuesNote
07:00s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 45; wt 1.5333333333333332Windy cool forecast with limited solar; keep conservative we

Tuesday November 03

Primary crop-band changes:

TimeValuesNote
07:00hyst 0.19749999999999998Clearer dry dawn possible; open bounded assist only on measu

Tactical tunable changes:

TimeValuesNote
07:00s2 1.8025000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 33.75; gap 37.5; wt 1.6333333333333333Clearer dry dawn possible; open bounded assist only on measu

Changed secondary parameters:

TimeParameterChange
12:09band_track_fractioninitial 0
12:09cold_vent_guard_delta_finitial 8
12:09cool_stage2_exit_hysteresis_finitial 1
12:09direct_wet_stress_min_dew_margin_finitial 8
12:09direct_wet_stress_vpd_margin_kpainitial 0.05
12:09dwell_gate_msinitial 240000
12:09enthalpy_closeinitial 1
12:09enthalpy_openinitial -2
12:09fog_escalation_kpainitial 0.4
12:09heat_hysteresisinitial 1
12:09min_fog_off_sinitial 78
12:09min_fog_on_sinitial 57
12:09mist_backoff_sinitial 600
12:09mist_max_closed_vent_sinitial 600
12:09mist_thermal_relief_sinitial 90
12:09mister_all_delay_sinitial 84
12:09mister_engage_delay_sinitial 42
12:09mister_water_budget_galinitial 300
12:09night_vpd_bias_kpainitial 0
12:09outdoor_staleness_max_sinitial 600
12:09sw_dwell_gate_enabledinitial 1
12:09sw_fog_closes_ventinitial 1
12:09sw_mister_closes_ventinitial 0
12:09sw_summer_vent_enabledinitial 1
12:09temp_hysteresisinitial 1.78
12:09vent_exchange_fractioninitial 0.3
12:09vent_prefer_dp_delta_finitial 3
12:09vent_prefer_temp_delta_finitial 4
12:09vpd_watch_dwell_sinitial 60
18:00fog_escalation_kpa0.4 → 0.45
14:00fog_escalation_kpa0.45 → 0.4
07:00fog_escalation_kpa0.4 → 0.45
07:00fog_escalation_kpa0.45 → 0.3
07:00min_fog_off_s78 → 66
07:00min_fog_on_s57 → 61.5

🌆 Evening Cycle (6:04 PM) — iris-20261031-1800

Status

validated

Outcome score

2/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261031-1108

Previous hypothesis: Cloud-cover deviation is an outdoor forecast miss/local clearing, not equipment failure: observed cloud is 0% with 348 W/m² solar, while greenhouse air is 73.1°F/0.97 kPa with 12.3°F dew margin and low zone spread; temperature and VPD remain within the latest dispatcher corridors. Keep the existing conditional dry-edge experiment: wet assist only on live VPD edge excess with dew margin >=8°F; do not wet on the cloud forecast alone. Preserve heat-first/cold-night posture and taper wet duty for the forecast cold, very humid night and Sunday dawn. Historical cloud calibration has no paired samples; temp/VPD calibration is modest and does not justify an offset. Result: Oct 31 scorecard: planner_score 73.5, contract-2 legacy temp/VPD fractions 25.5%/81.2%; nominal stress 21.26h (cold 16.98h, VPD-high 4.28h, VPD-low 0), dew-risk 0h, minimum dew margin 7.4°F. Costs are unavailable; total water was 2 gal vs 7-day average 166 gal. For this plan’s scoped 18:04–midnight window, score 63.5, cold stress 1.77h, VPD-high/low 0h; dryout query returned no episodes but safety is pending and daylight coverage is incomplete. These results are consistent with avoiding wetting and dew risk, but do not establish causal benefit; the daily bottleneck was cold/temperature, and write delivery was weak (31 missed requests per context). Score: 2/10

Hypothesis

Testing: Directional only: test conservative overnight exchange against cold stress while preserving a live-edge moisture response; no crop or resource causality claimed. Expected outcome: Keep dp_risk_hours at 0 and minimum dew margin above 5°F; reduce cold stress versus today’s 11.3h without forecast-only wetting. Resource and physical crop outcomes remain unverified.

Conditions

Outdoor peak

51.0°F

RH minimum

77.0%

Solar peak

0.0 W/m²

Cloud average

85.0%

Cold saturated night: forecast falls from 51°F to 40°F, RH rises to 100%, and outdoor VPD approaches zero. Indoors is 73.2°F/0.77 kPa with 9.4°F dew margin; heat1 is on.

Expected stress windows

coldhigh · 2026-10-31T20:00:00-06:00 to 2026-11-01T07:00:00-07:00

Use longer thermal lead and require a stronger outdoor advantage for exchange; penalize relay churn.

vpd_lowmedium · 2026-11-01T02:00:00-07:00 to 2026-11-01T06:00:00-07:00

No forecast-only wetting; keep low mist duty and an 8°F dew-margin floor, with live-edge response retained.

Parameter rationale

mister_engage_kpa1.6 → 1.1; Outdoor VPD falls to 0.00–0.08 kPa; indoor VPD is 0.77 below the 0.95 high edge.

Avoid forecast-only wetting while retaining bounded response to measured VPD-high excess.

mister_all_kpa1.9 → 1.25; Saturated outdoor air and current indoor VPD below the high edge make all-zone wetting unnecessary overnight.

Prevent routine all-zone misting unless live VPD rises materially above the served edge.

vent_prefer_temp_delta_f5.0 → 10.0; Outdoor temperature falls to 40°F before dawn while heat1 is active; cold stress dominated today.

Reduce avoidable cold-air exchange during heating and preserve dew margin above 5°F.

Setpoints

Saturday October 31

Primary crop-band changes:

TimeValuesNote
18:00hyst 0.2175Evening settle: preserve heat, require a stronger outdoor ad

Tactical tunable changes:

TimeValuesNote
18:00s2 1.8900000000000001; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 37.5; wt 1.5666666666666667Evening settle: preserve heat, require a stronger outdoor ad

Sunday November 01

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.22249999999999998Midnight: colder saturated air; prioritize stable heat and d
05:00hyst 0.22249999999999998Pre-dawn: forecast minimum is 40°F with saturated air; exten

Tactical tunable changes:

TimeValuesNote
00:00s2 1.8900000000000001; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 37.5; wt 1.5333333333333332Midnight: colder saturated air; prioritize stable heat and d
05:00s2 1.875; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.0959999999999999; all 1.246; pulse 30; gap 33.75; wt 1.5666666666666667Pre-dawn: forecast minimum is 40°F with saturated air; exten

Changed secondary parameters:

TimeParameterChange
18:00band_track_fractioninitial 0
18:00cold_vent_guard_delta_finitial 12
18:00cool_stage2_exit_hysteresis_finitial 1
18:00direct_wet_stress_min_dew_margin_finitial 8
18:00direct_wet_stress_vpd_margin_kpainitial 0.15
18:00dwell_gate_msinitial 300000
18:00enthalpy_closeinitial 1
18:00enthalpy_openinitial -2
18:00fog_escalation_kpainitial 0.45
18:00heat_hysteresisinitial 1
18:00min_fog_off_sinitial 66
18:00min_fog_on_sinitial 61.5
18:00mist_backoff_sinitial 600
18:00mist_max_closed_vent_sinitial 600
18:00mist_thermal_relief_sinitial 90
18:00mister_all_delay_sinitial 102
18:00mister_engage_delay_sinitial 51
18:00mister_water_budget_galinitial 150
18:00night_vpd_bias_kpainitial 0
18:00outdoor_staleness_max_sinitial 600
18:00sw_dwell_gate_enabledinitial 1
18:00sw_fog_closes_ventinitial 1
18:00sw_mister_closes_ventinitial 0
18:00sw_summer_vent_enabledinitial 1
18:00temp_hysteresisinitial 2.14
18:00vent_exchange_fractioninitial 0.3
18:00vent_prefer_dp_delta_finitial 8
18:00vent_prefer_temp_delta_finitial 8
18:00vpd_watch_dwell_sinitial 75
00:00cold_vent_guard_delta_f12 → 14
00:00dwell_gate_ms300000 → 315000
00:00fog_escalation_kpa0.45 → 0.5
00:00mister_all_delay_s102 → 106.5
00:00mister_engage_delay_s51 → 53.25
00:00temp_hysteresis2.14 → 2.23
00:00vent_prefer_temp_delta_f8 → 10
00:00vpd_watch_dwell_s75 → 78.75
05:00min_fog_off_s66 → 60
05:00min_fog_on_s61.5 → 63.75

End-of-Day Summary

Climate

Temperature

61.3–83.1°F; avg 68.6°F

VPD

0.44–1.32 kPa; avg 0.71 kPa

Relative humidity

59.8–76.5%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: legacy_invalid_exterior_proxy_plus_fixture_estimate
  • Validity: dli-validity-v1; 2024-01-01T00:00:00+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (>85°F): 0.0h
  • VPD stress (>2.0 kPa): 4.3h
  • Cold stress (<55°F): 17.0h

Economics

Electric

Not available

Gas

USD 0.51

Water

USD 0.010

Total

Not available

Equipment Runtimes

EquipmentRuntimeReading
Fan 10 minPrimary exhaust runtime.
Fan 20 minSecondary exhaust runtime.
Vent0 minIntake vent runtime.
Fog2 minFogger runtime.
Heat 1 electric1280 minElectric heater runtime.
Heat 2 gas49 minGas heater runtime.
Grow lights888 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center0.00hCenter mister runtime.

Water

  • Total: 2 gal
  • Mister: 2 gal

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Lime Treewest73%8Observation notes are collapsed below to avoid publishing partial vision snippets.
Vanda Orchidscenter83%4Observation notes are collapsed below to avoid publishing partial vision snippets.
peppereast65%4Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
Lime TreeGemini Vision notes

Hanging plants in the west zone appear upright with turgid leaves. Roots are visible and appear white and healthy. No obvious wilting or yellowing observed in the infrared spectrum. || Large potted plant visible in the background (upper center/right); canopy appears full, no visible leaf drop or structural damage. || Large potted plant with broad green leaves located in the central floor area. Foliage appears healthy and turgid with no visible signs of yellowing or pest damage. || Large potted plant with exposed roots (likely an orchid or similar epiphyte) located in the center-left area. Foliage is vibrant green and turgid. Roots appear white and healthy. || Large potted tree visible on the left side. Leaves appear green, though the specific variety is difficult to confirm from this distance. || Visible in the left-hand shelving area. Foliage appears dense and upright. No visible signs of wilting or leaf drop. The bright white appearance is consistent with IR illumination of healthy g

Vanda OrchidsGemini Vision notes

Hanging baskets visible in the center background. Roots appear exposed and healthy (white/grey), typical for Vanda. Leaves are green and turgid. || Hanging baskets visible in the center background. Roots appear white and healthy, indicating good hydration and no immediate stress. || Hanging baskets visible in the upper center of the frame. Roots appear exposed and healthy; no visible wilting or leaf discoloration. || Hanging baskets visible in the upper center; roots appear dense and healthy, no obvious signs of wilting or discoloration.

pepperGemini Vision notes

Located on the right-hand shelving units near the hydroponic piping. Plants appear small and upright. While specific seedling details are difficult to resolve in IR, the general structure suggests healthy development without obvious collapse or damage. || Seedlings visible in blue trays on the left shelving unit. Plants appear upright and green, though specific individual health is difficult to assess at this distance. || Seedlings visible in blue trays on the left shelving unit. Plants appear upright and green, though specific individual health is hard to distinguish at this distance. || [low_light, potential_crowding] Seedlings on the east shelving unit are small and difficult to distinguish individually. The 0 lux reading suggests the grow lights for this zone may be off or the sensor is not capturing the specific light source, which is critical for seedling development.

Hourly Pattern

HourTemperatureVPDRH
12:0076.3°F1.04 kPa66.5%
13:0076.2°F1.03 kPa66.7%
14:0077.1°F1.15 kPa63.9%
15:0079.9°F1.17 kPa66.5%
16:0079.9°F1.00 kPa71.5%
17:0074.7°F0.84 kPa71.6%
18:0071.6°F0.73 kPa72.3%
19:0071.1°F0.74 kPa71.4%
20:0068.8°F0.68 kPa71.9%
21:0066.7°F0.59 kPa73.7%
22:0065.3°F0.54 kPa74.7%
23:0064.2°F0.51 kPa75.1%
00:0063.6°F0.50 kPa75.4%
01:0063.0°F0.48 kPa75.5%
02:0062.5°F0.47 kPa75.6%
03:0062.2°F0.47 kPa75.5%
04:0061.9°F0.46 kPa75.6%
05:0061.5°F0.46 kPa75.7%
06:0061.6°F0.46 kPa75.7%
07:0064.4°F0.57 kPa72.6%
08:0066.1°F0.64 kPa71.1%
09:0067.4°F0.70 kPa69.5%
10:0070.8°F0.84 kPa67.5%
11:0072.7°F0.94 kPa65.8%

7-Day Stress Context

DateHeatVPD highCold
2026-10-250.0h8.7h16.2h
2026-10-260.0h0.9h16.5h
2026-10-270.0h1.3h16.6h
2026-10-280.0h4.8h16.7h
2026-10-290.0h6.5h17.0h
2026-10-300.0h4.2h16.7h
2026-10-310.0h4.3h17.0h