November 01, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
12
3
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261101-0016. Resolved 00:20 MDT. |
| Morning planning cycle | 06:31 | SUNRISE | delivery_failed | Delivery recorded without a public plan write. |
| Morning planning cycle | 06:33 | SUNRISE | plan_written | Wrote public plan iris-20261101-0634. Resolved 06:36 MDT. |
| Solar peak planning checkpoint | 11:45 | SOLAR_MAX | acked | Acknowledged: No tunable change: live solar 226 W/m² is below the forecast peak of 286; indoor VPD 1.08 is inside the dispatcher corridor (0.67–1.22) and only slightly above the 11:00 reading. Strong 13.6°F dew margin and cool, humid forecast; existing afternoon plan covers the remaining period. Resolved 11:46 MDT. |
| Peak Stress | 13:45 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 13:47 MDT. |
| Decline | 15:59 | TRANSITION | acked | Acknowledged: No tunable change: live climate is 76.7°F / 1.11 kPa VPD with 12.8°F dew margin; vent, fans, fog and misters are off, heat1 is active. The active plan already schedules a decline taper at 16:30 (mister gap 56s, fog escalation 0.4) ahead of the cool, humid overnight forecast. Keep the existing recovery/taper posture; conditions do not warrant an immediate override. Resolved 16:00 MDT. |
| Evening planning cycle | 19:40 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 19:42 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 19:43 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 19:44 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 19:45 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 19:46 | SUNSET | plan_written | Wrote public plan iris-20261101-1947. Resolved 19:50 MDT. |
🌅 Morning Cycle (12:20 AM) — iris-20261101-0016
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261031-1800
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:51,“outdoor_rh_min_pct”:77,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:85,“notes”:“Cold saturated night: forecast falls from 51°F to 40°F, RH rises to 100%, and outdoor VPD approaches zero. Indoors is 73.2°F/0.77 kPa with 9.4°F dew margin; heat1 is on.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-10-31T20:00:00-06:00”,“end”:“2026-11-01T07:00:00-07:00”,“severity”:“high”,“mitigation”:“Use longer thermal lead and require a stronger outdoor advantage for exchange; penalize relay churn.”},{“kind”:“vpd_low”,“start”:“2026-11-01T02:00:00-07:00”,“end”:“2026-11-01T06:00:00-07:00”,“severity”:“medium”,“mitigation”:“No forecast-only wetting; keep low mist duty and an 8°F dew-margin floor, with live-edge response retained.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.6,“new_value”:1.1,“forecast_anchor”:“Outdoor VPD falls to 0.00–0… Result: Superseded at 06:36 MST by the persisted SUNRISE plan. Through the available Nov 1 partial scorecard snapshot (recorded 06:08 MST), contract-2 planner_score was 63.5; nominal stress was 6.77h cold, with VPD-high/low 0h, dew-risk 0h, and minimum dew margin 7.6°F. Temperature was the weak axis. Cost and water fields were null; observed-minute and physical crop-band evidence were ineligible/unavailable. The prior-night dryout read for Oct 31 returned no episodes, but coverage is incomplete and safety pending, so this is not proof of zero admission or effectiveness. Delivery audit in assembled context showed 26 missed requests; no causal benefit is established. Score: 3/10
Hypothesis
Testing: Directional cold/wet overnight posture: no forecast-only wetting; retain live band-edge assist only with healthy dew margin. Expected outcome: By 09:00 MST: dp-risk 0h, minimum dew margin >5°F, added VPD-low <1h, and no avoidable cold-air exchange; costs and crop outcomes unverified.
Setpoints
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:17 | hyst 0.1975 | Hold heat overnight; no forecast-only wetting or unnecessary |
| 03:00 | hyst 0.1975 | Cold saturated pre-dawn: maintain thermal lead and require a |
| 06:30 | hyst 0.1975 | At sunrise, allow only modest band-edge wet assist if live V |
| 09:00 | hyst 0.1975 | Early-day handoff stays conservative; respond to observed ba |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:17 | s2 2.0100000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 60; wt 1.2666666666666666 | Hold heat overnight; no forecast-only wetting or unnecessary |
| 03:00 | s2 2.0100000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 60; wt 1.2666666666666666 | Cold saturated pre-dawn: maintain thermal lead and require a |
| 06:30 | s2 1.9600000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 60; wt 1.3333333333333333 | At sunrise, allow only modest band-edge wet assist if live V |
| 09:00 | s2 1.9275; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.805; all 1.005; pulse 30; gap 60; wt 1.4000000000000001 | Early-day handoff stays conservative; respond to observed ba |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:17 | band_track_fraction | initial 0 |
| 00:17 | cold_vent_guard_delta_f | initial 12 |
| 00:17 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:17 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:17 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:17 | dwell_gate_ms | initial 240000 |
| 00:17 | enthalpy_close | initial 1 |
| 00:17 | enthalpy_open | initial -2 |
| 00:17 | fog_escalation_kpa | initial 0.4 |
| 00:17 | heat_hysteresis | initial 1 |
| 00:17 | min_fog_off_s | initial 114 |
| 00:17 | min_fog_on_s | initial 43.5 |
| 00:17 | mist_backoff_s | initial 600 |
| 00:17 | mist_max_closed_vent_s | initial 600 |
| 00:17 | mist_thermal_relief_s | initial 90 |
| 00:17 | mister_all_delay_s | initial 84 |
| 00:17 | mister_engage_delay_s | initial 42 |
| 00:17 | mister_water_budget_gal | initial 120 |
| 00:17 | night_vpd_bias_kpa | initial 0 |
| 00:17 | outdoor_staleness_max_s | initial 600 |
| 00:17 | sw_dwell_gate_enabled | initial 1 |
| 00:17 | sw_fog_closes_vent | initial 1 |
| 00:17 | sw_mister_closes_vent | initial 0 |
| 00:17 | sw_summer_vent_enabled | initial 1 |
| 00:17 | temp_hysteresis | initial 1.78 |
| 00:17 | vent_exchange_fraction | initial 0.3 |
| 00:17 | vent_prefer_dp_delta_f | initial 5 |
| 00:17 | vent_prefer_temp_delta_f | initial 8 |
| 00:17 | vpd_watch_dwell_s | initial 60 |
| 03:00 | cold_vent_guard_delta_f | 12 → 14 |
| 03:00 | vent_prefer_temp_delta_f | 8 → 10 |
| 06:30 | cold_vent_guard_delta_f | 14 → 12 |
| 06:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 06:30 | min_fog_off_s | 114 → 108 |
| 06:30 | min_fog_on_s | 43.5 → 45.75 |
| 06:30 | vent_prefer_temp_delta_f | 10 → 8 |
| 09:00 | cold_vent_guard_delta_f | 12 → 11 |
| 09:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 09:00 | min_fog_off_s | 108 → 102 |
| 09:00 | min_fog_on_s | 45.75 → 48 |
| 09:00 | vent_prefer_temp_delta_f | 8 → 7 |
🌅 Morning Cycle (6:36 AM) — iris-20261101-0634
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261101-0016
Previous hypothesis: Oct 31 contract-2 planner score was 73.6 (resource weight 0); legacy binary temp/VPD fractions 25.5%/81.2%, nominal stress 21.26h (cold 16.98h, VPD-high 4.28h), dp-risk 0h and min margin 7.4°F. Coverage, crop outcomes, and costs are unqualified. The prior 18:04 plan’s scoped window through midnight shows 0.03h cold stress, no VPD-high/low, 100% legacy VPD fraction, and score 68.3; fresh climate is 63.4°F/0.51 kPa with 8.1°F dew margin. Its overnight safety expectations are so far consistent, but only the early portion ran, so no causal effect is established. Nov 1 remains cold and saturated (43°F dawn, RH near 100%, overcast, negligible solar): preserve heat, avoid forecast-only wetting and unnecessary cold exchange, while retaining limited live-edge wet assist only if VPD exceeds the current band and dew margin stays healthy… Result: Previous-plan validation (window-scoped, partial through the current decline checkpoint): the window scorecard reports planner score 73.6, no VPD-low stress, 4.27 h cold stress and 1.63 h VPD-high stress; minimum dew margin was 7.6°F and dp-risk 0h. The predicted medium cold window was directionally consistent with cold stress, while the plan’s no-added-VPD-low/dew-risk expectation held. The wet-assist rationale is only partly supported: VPD-high stress persisted, and the context records 25 missed plan requests, so delivery and causality are weak. Forecast conditions were materially brighter/warmer than predicted (solar peak 613 vs 282 W/m²; outdoor peak 64.3 vs 60°F), cloud actual unavailable. Score 6/10: partial safety/outcome success, but persistent cold/VPD-high stress, forecast miss and delivery failures limit credit; no causal crop/resource claim. Score: 6/10
Hypothesis
Testing: Test edge-triggered, dew-margin-gated wet assist through a cool overcast day; compare stress and relay behavior without claiming causal crop benefit. Expected outcome: Keep dew-risk at 0h, added VPD-low under 1h, and avoid unnecessary cold-air exchange; retain live-edge wet response. No cost or crop-benefit claim.
Conditions
60.0°F
56.0%
282.0 W/m²
96.0%
Cold, heavily overcast Sunday: indoor 64.3°F/0.56 kPa, dew margin 9°F, heat1 on. Yesterday temperature compliance lagged VPD; costs unavailable.
Expected stress windows
Preserve heat and limit avoidable cold exchange; wet only on live VPD-edge excess with dew margin >=8°F.
Parameter rationale
Keep wet assist available near the live VPD high edge without forecast-only misting or added VPD-low.
Setpoints
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:34 | hyst 0.21250000000000002 | Dawn: cold saturated air; heat-first, no forecast-only wetti |
| 09:00 | hyst 0.21250000000000002 | Morning ramp: allow low-duty wet assist only if measured VPD |
| 15:00 | hyst 0.21250000000000002 | Peak stress: forecast VPD tops 0.77; keep bounded edge suppo |
| 16:30 | hyst 0.21250000000000002 | Decline: taper wet duty only as actual VPD recovers; retain |
| 19:00 | hyst 0.21250000000000002 | Evening: cold humid air returns; low duty and no excess wett |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:34 | s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 56.25; wt 1.3666666666666667 | Dawn: cold saturated air; heat-first, no forecast-only wetti |
| 09:00 | s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 56.25; wt 1.38 | Morning ramp: allow low-duty wet assist only if measured VPD |
| 15:00 | s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 56.25; wt 1.4 | Peak stress: forecast VPD tops 0.77; keep bounded edge suppo |
| 16:30 | s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 56.25; wt 1.38 | Decline: taper wet duty only as actual VPD recovers; retain |
| 19:00 | s2 1.965; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.006; all 1.206; pulse 30; gap 56.25; wt 1.3533333333333333 | Evening: cold humid air returns; low duty and no excess wett |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:34 | band_track_fraction | initial 0 |
| 06:34 | cold_vent_guard_delta_f | initial 12 |
| 06:34 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:34 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:34 | direct_wet_stress_vpd_margin_kpa | initial 0.1 |
| 06:34 | dwell_gate_ms | initial 285000 |
| 06:34 | enthalpy_close | initial 1 |
| 06:34 | enthalpy_open | initial -2 |
| 06:34 | fog_escalation_kpa | initial 0.4 |
| 06:34 | heat_hysteresis | initial 1 |
| 06:34 | min_fog_off_s | initial 96 |
| 06:34 | min_fog_on_s | initial 50.25 |
| 06:34 | mist_backoff_s | initial 600 |
| 06:34 | mist_max_closed_vent_s | initial 600 |
| 06:34 | mist_thermal_relief_s | initial 90 |
| 06:34 | mister_all_delay_s | initial 97.5 |
| 06:34 | mister_engage_delay_s | initial 48.75 |
| 06:34 | mister_water_budget_gal | initial 100 |
| 06:34 | night_vpd_bias_kpa | initial 0 |
| 06:34 | outdoor_staleness_max_s | initial 600 |
| 06:34 | sw_dwell_gate_enabled | initial 1 |
| 06:34 | sw_fog_closes_vent | initial 1 |
| 06:34 | sw_mister_closes_vent | initial 0 |
| 06:34 | sw_summer_vent_enabled | initial 1 |
| 06:34 | temp_hysteresis | initial 2.05 |
| 06:34 | vent_exchange_fraction | initial 0.3 |
| 06:34 | vent_prefer_dp_delta_f | initial 5 |
| 06:34 | vent_prefer_temp_delta_f | initial 8 |
| 06:34 | vpd_watch_dwell_s | initial 71.25 |
| 09:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 09:00 | fog_escalation_kpa | 0.4 → 0.35 |
| 15:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 16:30 | fog_escalation_kpa | 0.3 → 0.35 |
| 19:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 19:00 | fog_escalation_kpa | 0.35 → 0.4 |
🌆 Evening Cycle (7:50 PM) — iris-20261101-1947
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261101-0634
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:60,“outdoor_rh_min_pct”:56,“solar_peak_w_m2”:282,“cloud_cover_avg_pct”:96,“notes”:“Cold, heavily overcast Sunday: indoor 64.3°F/0.56 kPa, dew margin 9°F, heat1 on. Yesterday temperature compliance lagged VPD; costs unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-01T06:34:00-07:00”,“end”:“2026-11-01T10:30:00-07:00”,“severity”:“medium”,“mitigation”:“Preserve heat and limit avoidable cold exchange; wet only on live VPD-edge excess with dew margin >=8°F.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.6,“new_value”:0.95,“forecast_anchor”:“Indoor VPD 0.56; forecast maximum outdoor VPD 0.77 in cool overcast air.”,“expected_effect”:“Keep wet assist available near the live VPD high edge without forecast-only misting or added VPD-low.”}]} Result: Plan-window evidence (not the full-day score): window planner_score 66.4, nominal cold stress 0.02h, VPD-high/low 0h, and dp-risk 0h; current dew margin 8.2F. The predicted high cold stress did not occur in the scored plan window, though the cold-weather posture was conservative. No forecast-only wetting/VPD-low target and zero dp-risk were consistent with the prediction. The separate Nov 1 contract-2 daily score was 76.6 with 17.75h cold and 4.77h VPD-high stress, mostly outside this evening plan window; temp/VPD compliance were 25.7%/80.0%. Resource fields and physical crop evidence were unavailable, coverage was unverified, and the plan audit shows 17 missed rows plus one mismatch, so no causal effect or resource/crop benefit is established. An open house-band-drift alert reports VPD below the commanded band; retain as a current watch item, not a plan-window stress count. Score: 6/10
Hypothesis
Testing: Overnight cold/humidity posture; evaluate observed VPD, dew margin, cold exposure, and execution only. No causal crop or cost claim. Expected outcome: Maintain dp-risk at 0h and VPD-low below 1h; avoid unnecessary cold-air exchange while preserving edge-triggered wet assist. Cost evidence is unavailable.
Conditions
49.0°F
88.0%
13.0 W/m²
60.0%
Cold saturated night: outdoor low 41F, RH 88-95%, VPD 0.05-0.12; indoor 68.1F, VPD 0.68, dew margin 9.6F. Nov 1 cold stress dominated; resource data unavailable.
Expected stress windows
Retain heat, require a strong outdoor advantage for exchange, and penalize relay churn.
No forecast-only wetting; keep dew-gated edge response only if live VPD exceeds the high edge.
Parameter rationale
Avoid forecast-only misting; retain wet assist above the live edge, with dp-risk 0h and VPD-low under 1h.
Setpoints
Sunday November 01
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 19:46 | hyst 0.2175 | Evening settle: cold saturated air; preserve heat, avoid unn |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 19:46 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.877; all 1.127; pulse 30; gap 45; wt 1.5 | Evening settle: cold saturated air; preserve heat, avoid unn |
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.2175 | Midnight: forecast VPD remains near 0.1; limit wet duty, pre |
| 05:00 | hyst 0.2175 | Pre-dawn low near 41F: prioritize heat retention; keep wetti |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.877; all 1.127; pulse 30; gap 45; wt 1.4666666666666666 | Midnight: forecast VPD remains near 0.1; limit wet duty, pre |
| 05:00 | s2 1.92; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.877; all 1.127; pulse 30; gap 45; wt 1.4666666666666666 | Pre-dawn low near 41F: prioritize heat retention; keep wetti |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 19:46 | band_track_fraction | initial 0 |
| 19:46 | cold_vent_guard_delta_f | initial 15 |
| 19:46 | cool_stage2_exit_hysteresis_f | initial 1 |
| 19:46 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 19:46 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 19:46 | dwell_gate_ms | initial 300000 |
| 19:46 | enthalpy_close | initial 1 |
| 19:46 | enthalpy_open | initial -2 |
| 19:46 | fog_escalation_kpa | initial 0.4 |
| 19:46 | heat_hysteresis | initial 1 |
| 19:46 | min_fog_off_s | initial 78 |
| 19:46 | min_fog_on_s | initial 57 |
| 19:46 | mist_backoff_s | initial 600 |
| 19:46 | mist_max_closed_vent_s | initial 600 |
| 19:46 | mist_thermal_relief_s | initial 90 |
| 19:46 | mister_all_delay_s | initial 102 |
| 19:46 | mister_engage_delay_s | initial 51 |
| 19:46 | mister_water_budget_gal | initial 100 |
| 19:46 | night_vpd_bias_kpa | initial 0 |
| 19:46 | outdoor_staleness_max_s | initial 600 |
| 19:46 | sw_dwell_gate_enabled | initial 1 |
| 19:46 | sw_fog_closes_vent | initial 1 |
| 19:46 | sw_mister_closes_vent | initial 0 |
| 19:46 | sw_summer_vent_enabled | initial 1 |
| 19:46 | temp_hysteresis | initial 2.14 |
| 19:46 | vent_exchange_fraction | initial 0.3 |
| 19:46 | vent_prefer_dp_delta_f | initial 12 |
| 19:46 | vent_prefer_temp_delta_f | initial 15 |
| 19:46 | vpd_watch_dwell_s | initial 75 |
| 00:00 | fog_escalation_kpa | 0.4 → 0.45 |
| 05:00 | fog_escalation_kpa | 0.45 → 0.4 |
End-of-Day Summary
Climate
61.6–78.9°F; avg 68.2°F
0.46–1.33 kPa; avg 0.73 kPa
59.7–76.1%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 4.8h
- Cold stress (<55°F): 17.8h
Economics
Not available
USD 1.25
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 2 min | Fogger runtime. |
| Heat 1 electric | 1436 min | Electric heater runtime. |
| Heat 2 gas | 121 min | Gas heater runtime. |
| Grow lights | 1470 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 66% | 5 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 63% | 3 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 80% | 2 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Large specimen located in the west zone (likely the prominent hanging plant in the foreground) shows dense foliage and vigorous root growth. No signs of leaf drop or browning. || Potted tree visible on the right side (west zone). Canopy appears full and healthy. No obvious signs of leaf drop or wilting. || [unknown soil moisture] Large potted plant visible on the left (west zone). Soil moisture data is missing, making it difficult to assess hydration status accurately. || [visual_observation_impossible] Camera feed is blank (solid grey). Health score is a neutral default due to lack of visual data. || [wilting] Large potted plant in the center-left area. Leaves appear somewhat droopy and lack turgor, suggesting potential water stress or high humidity issues.
Hanging baskets visible in the upper center. Roots appear dense and healthy. Leaves look turgid, though low light conditions (0 lux) limit detailed assessment of color. || Hanging orchids visible in the upper center. Roots appear exposed and healthy. No obvious signs of wilting or leaf drop in the infrared view. || [visual_observation_impossible] Camera feed is blank (solid grey). Health score is a neutral default due to lack of visual data.
Seedlings visible in blue trays on the left shelving unit. Plants appear upright and green, though specific individual health is difficult to assess at this distance. || Seedlings visible on the shelving unit in the east zone appear upright and uniform. No visible wilting or discoloration detected under IR lighting.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 12:00 | 76.6°F | 1.14 kPa | 63.7% |
| 13:00 | 76.3°F | 1.12 kPa | 63.8% |
| 14:00 | 76.8°F | 1.21 kPa | 61.5% |
| 15:00 | 80.5°F | 1.18 kPa | 66.8% |
| 16:00 | 78.8°F | 1.00 kPa | 70.4% |
| 17:00 | 74.9°F | 0.83 kPa | 72.0% |
| 18:00 | 71.9°F | 0.73 kPa | 72.6% |
| 19:00 | 69.7°F | 0.67 kPa | 73.1% |
| 20:00 | 67.6°F | 0.60 kPa | 74.0% |
| 21:00 | 66.1°F | 0.55 kPa | 74.8% |
| 22:00 | 65.2°F | 0.53 kPa | 74.9% |
| 23:00 | 64.1°F | 0.51 kPa | 75.2% |
| 00:00 | 63.3°F | 0.50 kPa | 74.9% |
| 01:00 | 63.0°F | 0.49 kPa | 75.1% |
| 01:00 | 62.5°F | 0.48 kPa | 75.1% |
| 02:00 | 62.0°F | 0.48 kPa | 74.9% |
| 03:00 | 61.8°F | 0.48 kPa | 74.9% |
| 04:00 | 61.7°F | 0.47 kPa | 74.9% |
| 05:00 | 61.6°F | 0.48 kPa | 74.7% |
| 06:00 | 64.2°F | 0.55 kPa | 73.1% |
| 07:00 | 66.1°F | 0.63 kPa | 71.1% |
| 08:00 | 68.4°F | 0.74 kPa | 68.7% |
| 09:00 | 71.1°F | 0.88 kPa | 66.3% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-26 | 0.0h | 0.9h | 16.5h |
| 2026-10-27 | 0.0h | 1.3h | 16.6h |
| 2026-10-28 | 0.0h | 4.8h | 16.7h |
| 2026-10-29 | 0.0h | 6.5h | 17.0h |
| 2026-10-30 | 0.0h | 4.2h | 16.7h |
| 2026-10-31 | 0.0h | 4.3h | 17.0h |
| 2026-11-01 | 0.0h | 4.8h | 17.8h |