November 02, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
9
6
3
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261102-0016. Resolved 00:20 MDT. |
| Morning planning cycle | 06:33 | SUNRISE | plan_written | Wrote public plan iris-20261102-0634. Resolved 06:39 MDT. |
| Forecast deviation | 11:08 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261102-1108. Resolved 11:12 MDT. |
| Solar peak planning checkpoint | 11:46 | SOLAR_MAX | acked | Acknowledged: Solar is above the calibrated cloudy forecast (131 W/m² vs ~56 adjusted midday peak), but live VPD has eased from 1.20 to 1.03 kPa, below the 1.22 high edge, with 12.2°F dew margin. No wetting nudge; retain current posture. Resolved 11:47 MDT. |
| Forecast deviation | 12:08 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261102-1208. Resolved 12:11 MDT. |
| Forecast deviation | 12:39 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261102-1240. Resolved 12:41 MDT. |
| Peak Stress | 13:45 | TRANSITION | acked | Acknowledged: Peak checkpoint: fresh climate is 76.8°F/1.00 kPa with 11.3°F dew margin; no heat/VPD-high excursion is evident. Controller is IDLE, vent/fans/fog/misters are off and heat1 alone is on. Existing guarded posture is tracking; no concrete tactical change warranted. Resolved 13:46 MDT. |
| Decline | 15:57 | TRANSITION | acked | Acknowledged: No tunable change: live VPD is at the 0.99 kPa high edge (not rising above it), dew margin is healthy at 11.6°F, fog/misters are off, and the active posture already has a 45 s mister gap, 1.264 kPa engagement, and 0.30 kPa fog escalation. Cool overnight conditions are forecast; avoid unnecessary evening moisture changes. Resolved 15:57 MDT. |
| Evening planning cycle | 16:58 | SUNSET | plan_written | Wrote public plan iris-20261102-1658. Resolved 17:03 MDT. |
🌅 Morning Cycle (12:20 AM) — iris-20261102-0016
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261101-0634
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:60,“outdoor_rh_min_pct”:56,“solar_peak_w_m2”:282,“cloud_cover_avg_pct”:96,“notes”:“Cold, heavily overcast Sunday: indoor 64.3°F/0.56 kPa, dew margin 9°F, heat1 on. Yesterday temperature compliance lagged VPD; costs unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-01T06:34:00-07:00”,“end”:“2026-11-01T10:30:00-07:00”,“severity”:“medium”,“mitigation”:“Preserve heat and limit avoidable cold exchange; wet only on live VPD-edge excess with dew margin >=8°F.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.6,“new_value”:0.95,“forecast_anchor”:“Indoor VPD 0.56; forecast maximum outdoor VPD 0.77 in cool overcast air.”,“expected_effect”:“Keep wet assist available near the live VPD high edge without forecast-only misting or added VPD-low.”}]} Result: For iris-20261102-0016’s short 00:20–02:04 window, the plan-window record shows planner score 62.6, nominal cold stress 0.43h, no heat or VPD-high/low stress, no dew-risk, and 100% legacy VPD fraction; temperature was 0% in-band. Evidence is narrow and target/coverage is unqualified. The Nov 1 full-day contract-2 scorecard was 76.4, with temp 25.7% vs VPD 80.0%, 17.75h nominal cold and 4.77h VPD-high; daily cost and resource fields unavailable. Realized solar-night dryout returned no episodes, but safety is pending and this does not prove zero admission or effectiveness. No causal crop/resource effect established. Score: 5/10
Hypothesis
Testing: Conservative moisture posture through saturated overcast dawn; use live indoor VPD and dew margin, not outdoor VPD alone, for the daytime handoff. Expected outcome: Keep dew-point-risk at 0h and VPD-low under 1h; avoid unnecessary cold-air exchange overnight. If indoor VPD approaches its live high edge after 10:00, allow bounded moisture assist; no cost or crop-outcome claim.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21250000000000002 | Cold saturated air; VPD is below the live high edge. Preserv |
| 04:30 | hyst 0.21250000000000002 | Pre-dawn low near 46F and saturated; keep cold exchange and |
| 06:30 | hyst 0.21250000000000002 | Clouded sunrise ramp has negligible solar; retain heat, then |
| 10:00 | hyst 0.20750000000000002 | Outdoor VPD rises slowly to ~0.77; permit bounded assist onl |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.98; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.944; all 1.0939999999999999; pulse 30; gap 60; wt 1.3333333333333333 | Cold saturated air; VPD is below the live high edge. Preserv |
| 04:30 | s2 1.98; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.944; all 1.0939999999999999; pulse 30; gap 60; wt 1.3333333333333333 | Pre-dawn low near 46F and saturated; keep cold exchange and |
| 06:30 | s2 1.965; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.944; all 1.0939999999999999; pulse 30; gap 56.25; wt 1.38 | Clouded sunrise ramp has negligible solar; retain heat, then |
| 10:00 | s2 1.92; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.844; all 1.044; pulse 30; gap 45; wt 1.5333333333333332 | Outdoor VPD rises slowly to ~0.77; permit bounded assist onl |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 15 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 00:16 | dwell_gate_ms | initial 285000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.45 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 102 |
| 00:16 | min_fog_on_s | initial 48 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 97.5 |
| 00:16 | mister_engage_delay_s | initial 48.75 |
| 00:16 | mister_water_budget_gal | initial 100 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.05 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 10 |
| 00:16 | vent_prefer_temp_delta_f | initial 12 |
| 00:16 | vpd_watch_dwell_s | initial 71.25 |
| 06:30 | min_fog_off_s | 102 → 96 |
| 06:30 | min_fog_on_s | 48 → 50.25 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.1 |
| 10:00 | dwell_gate_ms | 285000 → 270000 |
| 10:00 | fog_escalation_kpa | 0.45 → 0.4 |
| 10:00 | min_fog_off_s | 96 → 78 |
| 10:00 | min_fog_on_s | 50.25 → 57 |
| 10:00 | mister_all_delay_s | 97.5 → 93 |
| 10:00 | mister_engage_delay_s | 48.75 → 46.5 |
| 10:00 | temp_hysteresis | 2.05 → 1.96 |
| 10:00 | vpd_watch_dwell_s | 71.25 → 67.5 |
🌅 Morning Cycle (2:04 AM) — iris-20261102-0202
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261101-0634
Result: Completed 4.6 h window: contract-2 window score 72.3; nominal stress was 1.89 h cold and 0.21 h VPD-high, with no heat/VPD-low stress or dew-risk hours. Window binary temp/VPD compliance remained very low (0.3%/7.0%); coverage and physical crop outcomes are unqualified, and no causal benefit is established. Score: 4/10
Hypothesis
Testing: Test a conservative saturated-dawn to measured-edge Tue/Wed moisture handoff; do not infer crop or resource benefit. Expected outcome: Through Nov 4: dp-risk 0h and VPD-low <1h/day; on Tue/Wed, keep VPD-high <4h/day when dew margin is >=8°F, with zero missed/mismatched plan rows. Costs and crop outcomes remain unqualified.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 02:02 | hyst 0.21750000000000003 | Cold saturated dawn: preserve heat; avoid forecast-only wett |
| 10:00 | hyst 0.21750000000000003 | Cloudy, cool day: allow modest assist only if live VPD cross |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 02:02 | s2 1.8925; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.888; all 1.088; pulse 30; gap 60; wt 1.3333333333333333 | Cold saturated dawn: preserve heat; avoid forecast-only wett |
| 10:00 | s2 1.8625; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.838; all 1.038; pulse 30; gap 52.5; wt 1.4333333333333333 | Cloudy, cool day: allow modest assist only if live VPD cross |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | hyst 0.21750000000000003 | Sunny Tue forecast peaks near 1.06 kPa outdoor VPD; keep mea |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | s2 1.8025000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.788; all 1; pulse 33.75; gap 37.5; wt 1.6333333333333333 | Sunny Tue forecast peaks near 1.06 kPa outdoor VPD; keep mea |
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | hyst 0.21750000000000003 | Wed cool dry-air ramp: retain bounded moisture response, avo |
| 20:00 | hyst 0.21750000000000003 | Taper only after observed VPD recovery; return to cold-night |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | s2 1.8325; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.818; all 1; pulse 30; gap 45; wt 1.5333333333333332 | Wed cool dry-air ramp: retain bounded moisture response, avo |
| 20:00 | s2 1.98; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.888; all 1.088; pulse 30; gap 60; wt 1.3333333333333333 | Taper only after observed VPD recovery; return to cold-night |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 02:02 | band_track_fraction | initial 0 |
| 02:02 | cold_vent_guard_delta_f | initial 15 |
| 02:02 | cool_stage2_exit_hysteresis_f | initial 1 |
| 02:02 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 02:02 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 02:02 | dwell_gate_ms | initial 300000 |
| 02:02 | enthalpy_close | initial 1 |
| 02:02 | enthalpy_open | initial -2 |
| 02:02 | fog_escalation_kpa | initial 0.4 |
| 02:02 | heat_hysteresis | initial 1 |
| 02:02 | min_fog_off_s | initial 102 |
| 02:02 | min_fog_on_s | initial 48 |
| 02:02 | mist_backoff_s | initial 600 |
| 02:02 | mist_max_closed_vent_s | initial 600 |
| 02:02 | mist_thermal_relief_s | initial 90 |
| 02:02 | mister_all_delay_s | initial 102 |
| 02:02 | mister_engage_delay_s | initial 51 |
| 02:02 | mister_water_budget_gal | initial 100 |
| 02:02 | night_vpd_bias_kpa | initial 0 |
| 02:02 | outdoor_staleness_max_s | initial 600 |
| 02:02 | sw_dwell_gate_enabled | initial 1 |
| 02:02 | sw_fog_closes_vent | initial 1 |
| 02:02 | sw_mister_closes_vent | initial 0 |
| 02:02 | sw_summer_vent_enabled | initial 1 |
| 02:02 | temp_hysteresis | initial 2.14 |
| 02:02 | vent_exchange_fraction | initial 0.3 |
| 02:02 | vent_prefer_dp_delta_f | initial 12 |
| 02:02 | vent_prefer_temp_delta_f | initial 15 |
| 02:02 | vpd_watch_dwell_s | initial 75 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 10:00 | fog_escalation_kpa | 0.4 → 0.35 |
| 10:00 | min_fog_off_s | 102 → 90 |
| 10:00 | min_fog_on_s | 48 → 52.5 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 10:00 | fog_escalation_kpa | 0.35 → 0.25 |
| 10:00 | min_fog_off_s | 90 → 66 |
| 10:00 | min_fog_on_s | 52.5 → 61.5 |
| 10:00 | vent_prefer_dp_delta_f | 12 → 10 |
| 10:00 | vent_prefer_temp_delta_f | 15 → 12 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.08 |
| 10:00 | fog_escalation_kpa | 0.25 → 0.3 |
| 10:00 | min_fog_off_s | 66 → 78 |
| 10:00 | min_fog_on_s | 61.5 → 57 |
| 20:00 | direct_wet_stress_vpd_margin_kpa | 0.08 → 0.15 |
| 20:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 20:00 | min_fog_off_s | 78 → 102 |
| 20:00 | min_fog_on_s | 57 → 48 |
| 20:00 | vent_prefer_dp_delta_f | 10 → 12 |
| 20:00 | vent_prefer_temp_delta_f | 12 → 15 |
🌅 Morning Cycle (6:39 AM) — iris-20261102-0634
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261101-1947
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:49,“outdoor_rh_min_pct”:88,“solar_peak_w_m2”:13,“cloud_cover_avg_pct”:60,“notes”:“Cold saturated night: outdoor low 41F, RH 88-95%, VPD 0.05-0.12; indoor 68.1F, VPD 0.68, dew margin 9.6F. Nov 1 cold stress dominated; resource data unavailable.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-01T19:46:00-07:00”,“end”:“2026-11-02T07:00:00-07:00”,“severity”:“high”,“mitigation”:“Retain heat, require a strong outdoor advantage for exchange, and penalize relay churn.”},{“kind”:“vpd_low”,“start”:“2026-11-02T00:00:00-07:00”,“end”:“2026-11-02T07:00:00-07:00”,“severity”:“medium”,“mitigation”:“No forecast-only wetting; keep dew-gated edge response only if live VPD exceeds the high edge.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.2,“new_value”:1.04,“forecast_anchor”:“Indoor VPD 0.68 is below high edge 0.99; outdoor overnight VPD forecast 0… Result: Completed 11-02 06:39–11:12 window only: window score 74.1; nominal cold stress 1.91 h and VPD-high 1.01 h; no heat/VPD-low/dew-risk hours in the window row. Today’s contract-2 daily snapshot is partial, resource fields unavailable, and physical crop/coverage evidence unqualified. Cold forecast aligned with the stress but the short window and no causal/tunable proof limit credit; no durable lesson extracted. Score: 3/10
Hypothesis
Testing: Guarded cold-dawn to measured dry-ramp handoff: conserve wetting below the VPD edge, then allow bounded band-relative mist/fog only on live excess with dew margin >=8F. Expected outcome: Nov 2: 0 dew-risk and <1 VPD-low hour; cold stress may remain dominant. During the Tue/Wed dry ramp, target <4 VPD-high hours/day when dew margin is >=8F; costs, coverage, and crop outcomes remain unqualified.
Conditions
59.0°F
26.0%
484.0 W/m²
75.0%
Cold overcast Monday (high 55F, low 39F, peak outdoor VPD 0.87); clearer Tuesday midday, then the 72h forecast reaches 59F/26% RH and 1.24 kPa VPD Wednesday. Current house 65.4F, VPD 0.65, dew margin 10.2F. Prior iris-20261102-0016: self-score 5 vs anchor 1 (+4); I credited a short window with no humidity/dew stress despite 0% temp compliance, 0.43h cold and unqualified evidence. The anchor is more conservative; no causal credit is established.
Expected stress windows
Preserve heat, avoid unnecessary cold-air exchange, and withhold wetting unless live VPD exceeds band with dew margin >=8F.
Use band-relative wet assist only on live edge excess; keep dew floor 8F and water budget 100 gal.
Parameter rationale
Make fog available at a bounded band-relative edge if VPD-high develops; target <4 VPD-high hours, <1 VPD-low hour, and 0 dew-risk hours.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:33 | hyst 0.20750000000000002 | Dawn: preserve heat; VPD 0.65 is below the live high edge an |
| 10:00 | hyst 0.20750000000000002 | Overcast ramp: allow near-edge assist, but avoid unnecessary |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:33 | s2 1.9075000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 60; wt 1.3133333333333332 | Dawn: preserve heat; VPD 0.65 is below the live high edge an |
| 10:00 | s2 1.8775000000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 56.25; wt 1.4 | Overcast ramp: allow near-edge assist, but avoid unnecessary |
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 13:00 | hyst 0.20750000000000002 | Peak forecast VPD 1.24: permit bounded band-relative mist/fo |
| 16:00 | hyst 0.20750000000000002 | Decline: retain edge support until measured VPD recovers; do |
| 18:00 | hyst 0.20750000000000002 | Evening: retain bounded near-edge assist through cutoff unle |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 13:00 | s2 1.7737500000000002; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 41.25; wt 1.5666666666666669 | Peak forecast VPD 1.24: permit bounded band-relative mist/fo |
| 16:00 | s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 41.25; wt 1.5666666666666669 | Decline: retain edge support until measured VPD recovers; do |
| 18:00 | s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9570000000000001; all 1.157; pulse 30; gap 41.25; wt 1.5666666666666669 | Evening: retain bounded near-edge assist through cutoff unle |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:33 | band_track_fraction | initial 0 |
| 06:33 | cold_vent_guard_delta_f | initial 12 |
| 06:33 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:33 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:33 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:33 | dwell_gate_ms | initial 270000 |
| 06:33 | enthalpy_close | initial 1 |
| 06:33 | enthalpy_open | initial -2 |
| 06:33 | fog_escalation_kpa | initial 0.35 |
| 06:33 | heat_hysteresis | initial 1 |
| 06:33 | min_fog_off_s | initial 108 |
| 06:33 | min_fog_on_s | initial 45.75 |
| 06:33 | mist_backoff_s | initial 600 |
| 06:33 | mist_max_closed_vent_s | initial 600 |
| 06:33 | mist_thermal_relief_s | initial 90 |
| 06:33 | mister_all_delay_s | initial 93 |
| 06:33 | mister_engage_delay_s | initial 46.5 |
| 06:33 | mister_water_budget_gal | initial 100 |
| 06:33 | night_vpd_bias_kpa | initial 0 |
| 06:33 | outdoor_staleness_max_s | initial 600 |
| 06:33 | sw_dwell_gate_enabled | initial 1 |
| 06:33 | sw_fog_closes_vent | initial 1 |
| 06:33 | sw_mister_closes_vent | initial 0 |
| 06:33 | sw_summer_vent_enabled | initial 1 |
| 06:33 | temp_hysteresis | initial 1.96 |
| 06:33 | vent_exchange_fraction | initial 0.3 |
| 06:33 | vent_prefer_dp_delta_f | initial 6 |
| 06:33 | vent_prefer_temp_delta_f | initial 8 |
| 06:33 | vpd_watch_dwell_s | initial 67.5 |
| 10:00 | min_fog_off_s | 108 → 96 |
| 10:00 | min_fog_on_s | 45.75 → 50.25 |
| 13:00 | fog_escalation_kpa | 0.35 → 0.25 |
| 13:00 | min_fog_off_s | 96 → 72 |
| 13:00 | min_fog_on_s | 50.25 → 59.25 |
☀️ Midday Cycle (11:12 AM) — iris-20261102-1108
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261102-0202
Previous hypothesis: Seven-day contract-2 planner score rose from 60.1 (Oct 26) to 76.4 (Nov 1), but nominal stress remained 21.3–24.2h/day, dominated by 16.5–17.8h cold and 0.9–6.5h VPD-high; early-week VPD-low and dew-risk also occurred. These are historical graded/controller diagnostics, not physical crop outcomes. Hold heat and avoid cold exchange during saturated dawns; make bounded, band-coupled wet assist available only for measured VPD edge stress on the Tue/Wed dry ramp, with dew and water limits intact. Costs, interior DLI, and crop-band evidence are unavailable; no causal benefit is assumed. Recent plan delivery misses and open heap-pressure, hydro-TDS sensor, and house-band-drift alerts remain watch items. Result: Completed 11-02 11:12–12:11 window: window score 74.1; nominal cold stress 0.41 h and VPD-high 0.22 h, no heat/VPD-low/dew-risk hours in the row. Wind forecast was substantially high, but fresh indoor readings and equipment showed no corroborating regime shift, so retaining the treatment was prudent; the short period does not establish a climate benefit. Resource and physical crop/coverage evidence unavailable; no lesson extracted. Score: 3/10
Hypothesis
Testing: Guarded cold-dawn to measured dry-ramp handoff: conserve wetting below the VPD edge, then allow bounded band-relative mist/fog only on live excess with dew margin >=8F. Expected outcome: Nov 2: 0 dew-risk and <1 VPD-low hour; cold stress may remain dominant. During the Tue/Wed dry ramp, target <4 VPD-high hours/day when dew margin is >=8F; costs, coverage, and crop outcomes remain unqualified.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 11:08 | hyst 0.19749999999999998 | Wind miss is not an indoor regime change; retain heat postur |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 11:08 | s2 1.825; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 41.25; wt 1.5666666666666669 | Wind miss is not an indoor regime change; retain heat postur |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.19749999999999998 | Forecast low 43F; preserve heat and avoid cold-air exchange; |
| 13:00 | hyst 0.19749999999999998 | Mild dry ramp; retain experiment's bounded band-relative wet |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.825; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 41.25; wt 1.5666666666666669 | Forecast low 43F; preserve heat and avoid cold-air exchange; |
| 13:00 | s2 1.865; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 41.25; wt 1.5666666666666669 | Mild dry ramp; retain experiment's bounded band-relative wet |
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.19749999999999998 | Wed forecast VPD peaks 1.16; correct modest lead-bin bias, a |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.865; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 41.25; wt 1.5666666666666669 | Wed forecast VPD peaks 1.16; correct modest lead-bin bias, a |
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.19749999999999998 | 48h+ calibration is less certain; keep conservative cold pos |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.905; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.256; all 1.456; pulse 30; gap 41.25; wt 1.5666666666666669 | 48h+ calibration is less certain; keep conservative cold pos |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 11:08 | band_track_fraction | initial 0 |
| 11:08 | cold_vent_guard_delta_f | initial 12 |
| 11:08 | cool_stage2_exit_hysteresis_f | initial 1 |
| 11:08 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 11:08 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 11:08 | dwell_gate_ms | initial 240000 |
| 11:08 | enthalpy_close | initial 1 |
| 11:08 | enthalpy_open | initial -2 |
| 11:08 | fog_escalation_kpa | initial 0.25 |
| 11:08 | heat_hysteresis | initial 1 |
| 11:08 | min_fog_off_s | initial 72 |
| 11:08 | min_fog_on_s | initial 59.25 |
| 11:08 | mist_backoff_s | initial 600 |
| 11:08 | mist_max_closed_vent_s | initial 600 |
| 11:08 | mist_thermal_relief_s | initial 90 |
| 11:08 | mister_all_delay_s | initial 84 |
| 11:08 | mister_engage_delay_s | initial 42 |
| 11:08 | mister_water_budget_gal | initial 100 |
| 11:08 | night_vpd_bias_kpa | initial 0 |
| 11:08 | outdoor_staleness_max_s | initial 600 |
| 11:08 | sw_dwell_gate_enabled | initial 1 |
| 11:08 | sw_fog_closes_vent | initial 1 |
| 11:08 | sw_mister_closes_vent | initial 0 |
| 11:08 | sw_summer_vent_enabled | initial 1 |
| 11:08 | temp_hysteresis | initial 1.78 |
| 11:08 | vent_exchange_fraction | initial 0.3 |
| 11:08 | vent_prefer_dp_delta_f | initial 6 |
| 11:08 | vent_prefer_temp_delta_f | initial 8 |
| 11:08 | vpd_watch_dwell_s | initial 60 |
☀️ Midday Cycle (12:11 PM) — iris-20261102-1208
validated
2/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261102-0202
Result: Completed 11-02 12:11–12:41 window: window score 74.1; nominal cold stress 0.21 h and VPD-high 0.11 h, no heat/VPD-low/dew-risk hours in the row. Indoor air and equipment remained stable despite the wind forecast miss, supporting no retune; this 30-minute window is too short to claim benefit. Costs and physical crop/coverage evidence unavailable; no lesson extracted. Score: 2/10
Hypothesis
Testing: Guarded cold-dawn to measured dry-ramp handoff: conserve wetting below the VPD edge, then allow bounded band-relative mist/fog only on live excess with dew margin >=8F. Expected outcome: Nov 2: 0 dew-risk and <1 VPD-low hour; cold stress may remain dominant. During the Tue/Wed dry ramp, target <4 VPD-high hours/day when dew margin is >=8F; costs, coverage, and crop outcomes remain unqualified.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:08 | hyst 0.1875 | Wind-only deviation; indoor state is in-band. Preserve exper |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:08 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.272; all 1.472; pulse 33.75; gap 41.25; wt 1.7 | Wind-only deviation; indoor state is in-band. Preserve exper |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.1875 | Cold dawn forecast; retain guarded posture and wet only on m |
| 13:00 | hyst 0.1875 | Modest dry ramp; allow bounded band-relative wet assist only |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.272; all 1.472; pulse 33.75; gap 41.25; wt 1.7 | Cold dawn forecast; retain guarded posture and wet only on m |
| 13:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.272; all 1.472; pulse 33.75; gap 41.25; wt 1.7 | Modest dry ramp; allow bounded band-relative wet assist only |
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.1875 | At 24–48h lead, VPD is historically overforecast; keep respo |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.272; all 1.472; pulse 33.75; gap 41.25; wt 1.7 | At 24–48h lead, VPD is historically overforecast; keep respo |
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.1875 | Far-lead VPD bias is uncertain; retain edge-only assist pend |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.73; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.272; all 1.472; pulse 33.75; gap 41.25; wt 1.7 | Far-lead VPD bias is uncertain; retain edge-only assist pend |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 12:08 | band_track_fraction | initial 0 |
| 12:08 | cold_vent_guard_delta_f | initial 12 |
| 12:08 | cool_stage2_exit_hysteresis_f | initial 1 |
| 12:08 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 12:08 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 12:08 | dwell_gate_ms | initial 210000 |
| 12:08 | enthalpy_close | initial 1 |
| 12:08 | enthalpy_open | initial -2 |
| 12:08 | fog_escalation_kpa | initial 0.25 |
| 12:08 | heat_hysteresis | initial 1 |
| 12:08 | min_fog_off_s | initial 72 |
| 12:08 | min_fog_on_s | initial 59.25 |
| 12:08 | mist_backoff_s | initial 600 |
| 12:08 | mist_max_closed_vent_s | initial 600 |
| 12:08 | mist_thermal_relief_s | initial 90 |
| 12:08 | mister_all_delay_s | initial 75 |
| 12:08 | mister_engage_delay_s | initial 37.5 |
| 12:08 | mister_water_budget_gal | initial 120 |
| 12:08 | night_vpd_bias_kpa | initial 0 |
| 12:08 | outdoor_staleness_max_s | initial 600 |
| 12:08 | sw_dwell_gate_enabled | initial 1 |
| 12:08 | sw_fog_closes_vent | initial 1 |
| 12:08 | sw_mister_closes_vent | initial 0 |
| 12:08 | sw_summer_vent_enabled | initial 1 |
| 12:08 | temp_hysteresis | initial 1.6 |
| 12:08 | vent_exchange_fraction | initial 0.3 |
| 12:08 | vent_prefer_dp_delta_f | initial 6 |
| 12:08 | vent_prefer_temp_delta_f | initial 8 |
| 12:08 | vpd_watch_dwell_s | initial 52.5 |
☀️ Midday Cycle (12:41 PM) — iris-20261102-1240
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261102-0202
Result: Scoped 11-02 12:41–17:03 window: planner score 77.7; contract-2 legacy binary temp/VPD fractions 27.9%/71.4%; nominal stress 2.99 h cold and 1.20 h VPD-high, with 0 heat, VPD-low, or dew-risk hours in the window row. Utility costs unavailable. Observed precipitation differed from forecast, but the contemporaneous indoor state remained stable, so holding posture was reasonable; the short window and unqualified coverage/physical crop evidence do not establish causal benefit. Scorecard attribution and plan-specific actuation evidence are limited. Score: 4/10
Hypothesis
Testing: Guarded cold-dawn to measured dry-ramp handoff: conserve wetting below the VPD edge, then allow bounded band-relative mist/fog only on live excess with dew margin >=8F. Expected outcome: Nov 2: 0 dew-risk and <1 VPD-low hour; cold stress may remain dominant. During the Tue/Wed dry ramp, target <4 VPD-high hours/day when dew margin is >=8F; costs, coverage, and crop outcomes remain unqualified.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:40 | hyst 0.19749999999999998 | Rain miss only; indoor state and relay truth show no matchin |
| 19:00 | hyst 0.19749999999999998 | Cold night forecast; preserve heat and suppress wetting unle |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:40 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Rain miss only; indoor state and relay truth show no matchin |
| 19:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Cold night forecast; preserve heat and suppress wetting unle |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.19749999999999998 | Cold dawn and low outdoor VPD; avoid forecast-only wetting a |
| 13:00 | hyst 0.19749999999999998 | Keep bounded band-relative wet assist available only for mea |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Cold dawn and low outdoor VPD; avoid forecast-only wetting a |
| 13:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Keep bounded band-relative wet assist available only for mea |
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | hyst 0.19749999999999998 | Wednesday dry ramp is modest; retain dew protection and unch |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 12:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Wednesday dry ramp is modest; retain dew protection and unch |
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.19749999999999998 | Thursday forecast dries; keep the 8°F dew floor and capped l |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.92; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.264; all 1.464; pulse 33.75; gap 45; wt 1.5666666666666667 | Thursday forecast dries; keep the 8°F dew floor and capped l |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 12:40 | band_track_fraction | initial 0 |
| 12:40 | cold_vent_guard_delta_f | initial 12 |
| 12:40 | cool_stage2_exit_hysteresis_f | initial 1 |
| 12:40 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 12:40 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 12:40 | dwell_gate_ms | initial 240000 |
| 12:40 | enthalpy_close | initial 1 |
| 12:40 | enthalpy_open | initial -2 |
| 12:40 | fog_escalation_kpa | initial 0.3 |
| 12:40 | heat_hysteresis | initial 1 |
| 12:40 | min_fog_off_s | initial 78 |
| 12:40 | min_fog_on_s | initial 57 |
| 12:40 | mist_backoff_s | initial 600 |
| 12:40 | mist_max_closed_vent_s | initial 600 |
| 12:40 | mist_thermal_relief_s | initial 90 |
| 12:40 | mister_all_delay_s | initial 84 |
| 12:40 | mister_engage_delay_s | initial 42 |
| 12:40 | mister_water_budget_gal | initial 120 |
| 12:40 | night_vpd_bias_kpa | initial 0 |
| 12:40 | outdoor_staleness_max_s | initial 600 |
| 12:40 | sw_dwell_gate_enabled | initial 1 |
| 12:40 | sw_fog_closes_vent | initial 1 |
| 12:40 | sw_mister_closes_vent | initial 0 |
| 12:40 | sw_summer_vent_enabled | initial 1 |
| 12:40 | temp_hysteresis | initial 1.78 |
| 12:40 | vent_exchange_fraction | initial 0.3 |
| 12:40 | vent_prefer_dp_delta_f | initial 6 |
| 12:40 | vent_prefer_temp_delta_f | initial 8 |
| 12:40 | vpd_watch_dwell_s | initial 60 |
🌆 Evening Cycle (5:03 PM) — iris-20261102-1658
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261102-0634
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:59,“outdoor_rh_min_pct”:26,“solar_peak_w_m2”:484,“cloud_cover_avg_pct”:75,“notes”:“Cold overcast Monday (high 55F, low 39F, peak outdoor VPD 0.87); clearer Tuesday midday, then the 72h forecast reaches 59F/26% RH and 1.24 kPa VPD Wednesday. Current house 65.4F, VPD 0.65, dew margin 10.2F. Prior iris-20261102-0016: self-score 5 vs anchor 1 (+4); I credited a short window with no humidity/dew stress despite 0% temp compliance, 0.43h cold and unqualified evidence. The anchor is more conservative; no causal credit is established.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-02T18:00:00-07:00”,“end”:“2026-11-03T08:00:00-07:00”,“severity”:“high”,“mitigation”:“Preserve heat, avoid unnecessary cold-air exchange, and withhold wetting unless live VPD exceeds band with dew margin >=8F… Result: Prior plan iris-20261102-1658 governed only its partial 0.301-day window through the midnight reset, short of its cold-stress window to 07:00 and before the planned Tue/Wed dry-ramp test. Its window-scorecard row returned planner_score 0.0 and all axis/stress fields 0.0; because coverage/eligible evidence is not established, these must not be read as proof of zero stress. On the separate Nov 2 contract-2 daily scorecard (not attributable to this plan), planner_score was 77.9 with resource weight 0; binary temp/VPD fractions 28.2%/71.1%, nominal cold 16.53h and VPD-high 6.65h, VPD-low 0h, dp-risk 0h; cost unavailable. The typed forecast anchors missed: outdoor peak actual 55.5F vs 50F, RH minimum 56% vs 42%, solar peak 446 vs 0 W/m2. No dew/VPD-low harm is consistent with the guarded-wetting intent, but plan-window effect and whether the two lower engagement thresholds improved response are unverified; transition audit records two guardrail-held and two missed entries. No causal crop/resource benefit or durable lesson established. Score: 4/10
Hypothesis
Testing: Guarded cold-dawn to measured dry-ramp handoff: conserve wetting below the VPD edge, then allow bounded band-relative mist/fog only on live excess with dew margin >=8F. Expected outcome: Nov 2: 0 dew-risk and <1 VPD-low hour; cold stress may remain dominant. During the Tue/Wed dry ramp, target <4 VPD-high hours/day when dew margin is >=8F; costs, coverage, and crop outcomes remain unqualified.
Conditions
50.0°F
42.0%
0.0 W/m²
87.25%
Tonight: indoor 72.0F/VPD 0.96, dew margin 12.8F; forecast low 39F by Tue 07:00. Partial score 73.9 vs 7d 70.7; temp compliance 36.9% trails VPD 66.5%, with 10.07h cold and 5.35h VPD-high nominal stress. Cost unavailable.
Expected stress windows
Retain heat with stable dwell; avoid cold exchange; low-duty wet assist only on live VPD excess, dew floor 8F.
Parameter rationale
Keep assist available near live edge while low duty limits added VPD-low and dew risk.
Preserve all-zone response near the served high band without running absent demand.
Setpoints
Monday November 02
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 17:00 | hyst 0.1875 | Evening settle: preserve heat; allow only live-edge wet assi |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 17:00 | s2 1.685; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 30; wt 1.7000000000000002 | Evening settle: preserve heat; allow only live-edge wet assi |
Tuesday November 03
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | Midnight: colder ambient; lower wet duty while retaining the |
| 05:30 | hyst 0.1875 | Pre-dawn: forecast 39F; lead thermal response, maintain dew |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.715; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 37.5; wt 1.7 | Midnight: colder ambient; lower wet duty while retaining the |
| 05:30 | s2 1.7; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.995; all 1.1949999999999998; pulse 33.75; gap 33.75; wt 1.7 | Pre-dawn: forecast 39F; lead thermal response, maintain dew |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 17:00 | band_track_fraction | initial 0 |
| 17:00 | cold_vent_guard_delta_f | initial 12 |
| 17:00 | cool_stage2_exit_hysteresis_f | initial 1 |
| 17:00 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 17:00 | dwell_gate_ms | initial 210000 |
| 17:00 | enthalpy_close | initial 1 |
| 17:00 | enthalpy_open | initial -2 |
| 17:00 | fog_escalation_kpa | initial 0.25 |
| 17:00 | heat_hysteresis | initial 1 |
| 17:00 | min_fog_off_s | initial 54 |
| 17:00 | min_fog_on_s | initial 66 |
| 17:00 | mist_backoff_s | initial 600 |
| 17:00 | mist_max_closed_vent_s | initial 600 |
| 17:00 | mist_thermal_relief_s | initial 90 |
| 17:00 | mister_all_delay_s | initial 75 |
| 17:00 | mister_engage_delay_s | initial 37.5 |
| 17:00 | mister_water_budget_gal | initial 120 |
| 17:00 | night_vpd_bias_kpa | initial 0 |
| 17:00 | outdoor_staleness_max_s | initial 600 |
| 17:00 | sw_dwell_gate_enabled | initial 1 |
| 17:00 | sw_fog_closes_vent | initial 1 |
| 17:00 | sw_mister_closes_vent | initial 0 |
| 17:00 | sw_summer_vent_enabled | initial 1 |
| 17:00 | temp_hysteresis | initial 1.6 |
| 17:00 | vent_exchange_fraction | initial 0.3 |
| 17:00 | vent_prefer_dp_delta_f | initial 6 |
| 17:00 | vent_prefer_temp_delta_f | initial 8 |
| 17:00 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | min_fog_off_s | 54 → 66 |
| 00:00 | min_fog_on_s | 66 → 61.5 |
| 05:30 | min_fog_off_s | 66 → 60 |
| 05:30 | min_fog_on_s | 61.5 → 63.75 |
End-of-Day Summary
Climate
60.3–80.1°F; avg 68.2°F
0.45–1.37 kPa; avg 0.82 kPa
55.9–75.6%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 6.7h
- Cold stress (<55°F): 16.5h
Economics
Not available
USD 1.91
USD 0.040
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 0 min | Primary exhaust runtime. |
| Fan 2 | 0 min | Secondary exhaust runtime. |
| Vent | 0 min | Intake vent runtime. |
| Fog | 10 min | Fogger runtime. |
| Heat 1 electric | 1343 min | Electric heater runtime. |
| Heat 2 gas | 184 min | Gas heater runtime. |
| Grow lights | 1682 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 8 gal
- Mister: 8 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 65% | 8 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 73% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 65% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Large potted tree visible on the right side. Foliage appears green and dense. Soil moisture sensor is not reporting data. || Visible in terracotta pots on the lower left shelves. Foliage is green and dense. || Visible in the foreground and mid-ground. The plant appears to have a healthy structure with a dense root system visible in the hanging basket. The leaves appear turgid, though the infrared lighting makes color assessment impossible. || Visible in the lower left corner in terracotta pots. Foliage is green and dense. The unavailable' soil moisture reading for the west zone suggests a sensor malfunction or missing data, as the plants do not appear desiccated. || [low temperature] Vegetative growth is visible in the west zone. The current temperature of 63.0°F is suboptimal for a tropical crop like a Lime Tree, potentially slowing growth or causing cold stress. || [potential cold stress] Large potted plant visible on the right (west zone). Temperature of 65.6°F is on the lower end for a
Hanging baskets visible in the center background. Roots appear white and healthy, indicating good hydration. Leaves are green and turgid. || Hanging baskets visible in the upper center. Roots appear dense and healthy. No visible wilting or leaf drop. || Hanging baskets visible in the upper center. Roots appear exposed and healthy. No obvious signs of wilting or browning, though infrared imaging limits color-based assessment. || [root exposure] Hanging baskets visible in the center background. Roots are exposed and appear dry/light-colored, which is typical for Vanda but requires monitoring given the 0 lux reading.
Visible in blue seedling trays on the left shelving unit. Plants appear uniform and green. || Visible in blue seedling trays on the left shelving unit. Plants appear upright and green with no visible signs of wilting or discoloration. || [low_light] Located on the shelving units to the right. The seedlings are small and appear to be in the early stages of development. The 0 lux reading suggests they are currently in a dark cycle or the sensor is not capturing the grow lights effectively. || [wilting, low soil moisture] Seedlings appear to be in the lower shelving units on the right. Soil moisture in the South (19.3%) is critically low for seedlings, likely causing visible wilting or drooping.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 73.1°F | 1.01 kPa | 63.7% |
| 11:00 | 73.9°F | 1.08 kPa | 62.4% |
| 12:00 | 76.6°F | 1.13 kPa | 63.7% |
| 13:00 | 77.2°F | 1.15 kPa | 63.8% |
| 14:00 | 76.4°F | 1.07 kPa | 65.7% |
| 15:00 | 75.4°F | 0.97 kPa | 67.9% |
| 16:00 | 73.7°F | 0.92 kPa | 67.6% |
| 17:00 | 72.9°F | 0.90 kPa | 67.5% |
| 18:00 | 70.7°F | 0.79 kPa | 69.2% |
| 19:00 | 69.1°F | 0.73 kPa | 70.2% |
| 20:00 | 66.6°F | 0.62 kPa | 72.1% |
| 21:00 | 65.3°F | 0.58 kPa | 73.0% |
| 22:00 | 64.3°F | 0.54 kPa | 73.9% |
| 23:00 | 63.4°F | 0.52 kPa | 74.2% |
| 00:00 | 62.8°F | 0.50 kPa | 74.5% |
| 01:00 | 62.2°F | 0.49 kPa | 74.5% |
| 02:00 | 61.3°F | 0.48 kPa | 74.0% |
| 03:00 | 60.8°F | 0.47 kPa | 74.2% |
| 04:00 | 60.6°F | 0.47 kPa | 74.3% |
| 05:00 | 62.9°F | 0.53 kPa | 73.0% |
| 06:00 | 64.2°F | 0.59 kPa | 71.5% |
| 07:00 | 66.2°F | 0.67 kPa | 69.8% |
| 08:00 | 68.3°F | 0.76 kPa | 68.2% |
| 09:00 | 71.3°F | 0.90 kPa | 65.7% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-27 | 0.0h | 1.3h | 16.6h |
| 2026-10-28 | 0.0h | 4.8h | 16.7h |
| 2026-10-29 | 0.0h | 6.5h | 17.0h |
| 2026-10-30 | 0.0h | 4.2h | 16.7h |
| 2026-10-31 | 0.0h | 4.3h | 17.0h |
| 2026-11-01 | 0.0h | 4.8h | 17.8h |
| 2026-11-02 | 0.0h | 6.7h | 16.5h |