November 04, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
6
3
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261104-0018. Resolved 00:20 MDT. |
| Morning planning cycle | 06:35 | SUNRISE | plan_written | Wrote public plan iris-20261104-0635. Resolved 06:38 MDT. |
| Solar peak planning checkpoint | 11:46 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 11:47 MDT. |
| Peak Stress | 13:46 | TRANSITION | acked | Acknowledged: No further tuning: live VPD is 1.00 kPa, only 0.01 above the 0.99 high edge, at 78.4°F with a safe 10.2°F dew margin and no heat stress. Current wet posture is already responsive (mister gap 30s, fog escalation 0.30); forecast VPD and outdoor temperature fall through evening, and the active plan already tapers at 16:00/18:00. Resolved 13:46 MDT. |
| Decline | 15:55 | TRANSITION | acked | Acknowledged: No tunable change: current VPD 0.91 kPa is below the 0.99 high edge, dew margin is 11°F, and heat is active with vents/fans/fog/misters off. Existing plan already tapers misting at 16:00 and further at 18:00; forecast cold overnight supports conservative wetting. Conditions are tracking the planned decline posture. Resolved 15:56 MDT. |
| Evening planning cycle | 16:55 | SUNSET | plan_written | Wrote public plan iris-20261104-1655. Resolved 17:00 MDT. |
🌅 Morning Cycle (12:20 AM) — iris-20261104-0018
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261103-1657
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:55,“outdoor_rh_min_pct”:41,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:56,“notes”:“Mostly cloudy, variable sky; forecast falls to 38F before dawn. Indoor 72.3F/VPD 0.87, dew margin 11.2F; house VPD is just below the current 0.95 high edge. Prior plan scored 4 vs deterministic anchor 1; 112/124 VPD guardrail events held changes, so efficacy is uncertain.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-03T18:00:00-07:00”,“end”:“2026-11-04T06:00:00-07:00”,“severity”:“high”,“mitigation”:“Preserve heat with stable dwell and conservative air exchange; wet only on live high-edge demand with dew margin >=8F.”}],“rationale”:[{“parameter”:“temp_hysteresis”,“old_value”:1.78,“new_value”:2.0,“forecast_anchor”:“Outdoor falls from 55F to 38F; heat1 ran 20.05h with 26 transitions today… Result: Scoped window 00:20-06:38 MST (about 6.3 h): contract-2 historical scorecard window score 73.7; binary house-average temp/VPD fractions 32.8%/66.9%; nominal cold stress 2.77 h, VPD-high 1.36 h, VPD-low 0.01 h, and dew-risk 0 h (minimum daily dew margin context 7.4°F). Cold remained the leading miss in the short window; moisture/condensation remained controlled, but no costs, fixed-panel coverage, consumed-target proof, or crop outcome are available. This is a cautious partial grade, not causal attribution. Score: 4/10
Hypothesis
Testing: Observe pre-dawn thermal stability and early VPD response; avoid attributing changes when guardrails hold requests. Expected outcome: By the 09:30 handoff, keep dew margin at or above 8F and avoid material VPD-low/dew stress; limit wetting to measured high-edge demand. Cold exposure may persist with 35F outdoor air; cost evidence is unavailable.
Setpoints
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21750000000000003 | Post-midnight: hold heat, avoid needless cold exchange; curr |
| 03:30 | hyst 0.21750000000000003 | Pre-dawn low 35F: preserve thermal stability; keep wet assis |
| 06:30 | hyst 0.21750000000000003 | Sunrise ramp remains cold/cloudy; do not pre-cool, allow onl |
| 09:30 | hyst 0.20750000000000002 | Early-day handoff: permit modest assist only if live VPD cro |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.845; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 48.75; wt 1.5 | Post-midnight: hold heat, avoid needless cold exchange; curr |
| 03:30 | s2 1.845; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 48.75; wt 1.5 | Pre-dawn low 35F: preserve thermal stability; keep wet assis |
| 06:30 | s2 1.83; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 33.75; gap 45; wt 1.5666666666666667 | Sunrise ramp remains cold/cloudy; do not pre-cool, allow onl |
| 09:30 | s2 1.815; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 41.25; gap 41.25; wt 1.6666666666666665 | Early-day handoff: permit modest assist only if live VPD cro |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 14 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 300000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.4 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 84 |
| 00:16 | min_fog_on_s | initial 54.75 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 102 |
| 00:16 | mister_engage_delay_s | initial 51 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.14 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 10 |
| 00:16 | vent_prefer_temp_delta_f | initial 10 |
| 00:16 | vpd_watch_dwell_s | initial 75 |
| 06:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 06:30 | min_fog_off_s | 84 → 78 |
| 06:30 | min_fog_on_s | 54.75 → 57 |
| 09:30 | dwell_gate_ms | 300000 → 270000 |
| 09:30 | fog_escalation_kpa | 0.35 → 0.3 |
| 09:30 | min_fog_off_s | 78 → 72 |
| 09:30 | min_fog_on_s | 57 → 59.25 |
| 09:30 | mister_all_delay_s | 102 → 93 |
| 09:30 | mister_engage_delay_s | 51 → 46.5 |
| 09:30 | temp_hysteresis | 2.14 → 1.96 |
| 09:30 | vpd_watch_dwell_s | 75 → 67.5 |
🌅 Morning Cycle (6:38 AM) — iris-20261104-0635
validated
2/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261103-1657
Result: Revised self-grade after reviewing the deterministic anchor: plan-scoped window (0.432 day fraction) had planner score 76.6, contract-2 binary temp/VPD fractions 25.4%/75.6%, 7.39 h nominal cold stress and 2.40 h VPD-high stress, with 0.01 h VPD-low and 0 h dew-risk. Although the cold and dry-ramp conditions were forecast and dew/VPD-low outcomes were good, both predicted stress severities were materially understated and 113 of 141 guardrail events were held; the mister-engage effect is therefore not demonstrated. I reduce my original 4 to 2 because I over-credited partial safety outcomes and broad planner score despite poor plan-window objectives and weak actuation attribution. Costs, physical coverage and crop outcomes remain unavailable; no durable lesson. Score: 2/10
Hypothesis
Testing: Test a restrained, live-edge midday wet-assist shoulder on a cold cloudy day without evening wetting. Expected outcome: Keep dew margin >=8F and VPD-low stress near zero; limit VPD-high exposure during the 1.05 kPa outdoor peak. Cold stress may persist; costs and crop benefit remain unverified.
Conditions
56.0°F
30.0%
494.0 W/m²
75.0%
Cold, mostly cloudy day; brief midday clearing, with a moderate dry-air VPD shoulder. Prior completed plan self-score 4 vs anchor 1: limited moisture-safety success, but 218/259 guardrail events were held, so no causal benefit is claimed.
Expected stress windows
Preserve stable heat through the 35F forecast low; avoid unnecessary cold-air exchange.
Band-coupled wet readiness near +0.05; restrained duty and fog only with dew margin >=8F.
Parameter rationale
Keep first wet assist reachable near a live high-edge excess while avoiding unnecessary dawn or evening wetting.
Setpoints
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:35 | hyst 0.2025 | Cold dawn: retain stable heat; wet only on measured VPD exce |
| 09:00 | hyst 0.2025 | Morning ramp: avoid extra cooling; keep wet assist band-rela |
| 14:00 | hyst 0.2025 | Peak dry shoulder: allow bounded wet assist if live VPD exce |
| 16:00 | hyst 0.2025 | Decline: retain measured recovery support, taper with the dr |
| 18:00 | hyst 0.20750000000000002 | Evening frost posture: no unnecessary wetting; preserve stab |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:35 | s2 1.95; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 30; gap 52.5; wt 1.4 | Cold dawn: retain stable heat; wet only on measured VPD exce |
| 09:00 | s2 1.90625; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 30; gap 52.5; wt 1.4333333333333333 | Morning ramp: avoid extra cooling; keep wet assist band-rela |
| 14:00 | s2 1.8762500000000002; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 33.75; gap 45; wt 1.5666666666666667 | Peak dry shoulder: allow bounded wet assist if live VPD exce |
| 16:00 | s2 1.95; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 30; gap 52.5; wt 1.4666666666666666 | Decline: retain measured recovery support, taper with the dr |
| 18:00 | s2 1.98; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9540000000000001; all 1.154; pulse 30; gap 60; wt 1.3333333333333333 | Evening frost posture: no unnecessary wetting; preserve stab |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:35 | band_track_fraction | initial 0 |
| 06:35 | cold_vent_guard_delta_f | initial 10 |
| 06:35 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:35 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:35 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:35 | dwell_gate_ms | initial 255000 |
| 06:35 | enthalpy_close | initial 1 |
| 06:35 | enthalpy_open | initial -2 |
| 06:35 | fog_escalation_kpa | initial 0.35 |
| 06:35 | heat_hysteresis | initial 1 |
| 06:35 | min_fog_off_s | initial 90 |
| 06:35 | min_fog_on_s | initial 52.5 |
| 06:35 | mist_backoff_s | initial 600 |
| 06:35 | mist_max_closed_vent_s | initial 600 |
| 06:35 | mist_thermal_relief_s | initial 90 |
| 06:35 | mister_all_delay_s | initial 88.5 |
| 06:35 | mister_engage_delay_s | initial 44.25 |
| 06:35 | mister_water_budget_gal | initial 120 |
| 06:35 | night_vpd_bias_kpa | initial 0 |
| 06:35 | outdoor_staleness_max_s | initial 600 |
| 06:35 | sw_dwell_gate_enabled | initial 1 |
| 06:35 | sw_fog_closes_vent | initial 1 |
| 06:35 | sw_mister_closes_vent | initial 0 |
| 06:35 | sw_summer_vent_enabled | initial 1 |
| 06:35 | temp_hysteresis | initial 1.87 |
| 06:35 | vent_exchange_fraction | initial 0.3 |
| 06:35 | vent_prefer_dp_delta_f | initial 4 |
| 06:35 | vent_prefer_temp_delta_f | initial 6 |
| 06:35 | vpd_watch_dwell_s | initial 63.75 |
| 14:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 14:00 | min_fog_off_s | 90 → 78 |
| 14:00 | min_fog_on_s | 52.5 → 57 |
| 16:00 | fog_escalation_kpa | 0.3 → 0.35 |
| 16:00 | min_fog_off_s | 78 → 90 |
| 16:00 | min_fog_on_s | 57 → 52.5 |
| 18:00 | dwell_gate_ms | 255000 → 270000 |
| 18:00 | fog_escalation_kpa | 0.35 → 0.4 |
| 18:00 | min_fog_off_s | 90 → 102 |
| 18:00 | min_fog_on_s | 52.5 → 48 |
| 18:00 | mister_all_delay_s | 88.5 → 93 |
| 18:00 | mister_engage_delay_s | 44.25 → 46.5 |
| 18:00 | temp_hysteresis | 1.87 → 1.96 |
| 18:00 | vpd_watch_dwell_s | 63.75 → 67.5 |
🌆 Evening Cycle (5:00 PM) — iris-20261104-1655
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261104-0635
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:56,“outdoor_rh_min_pct”:30,“solar_peak_w_m2”:494,“cloud_cover_avg_pct”:75,“notes”:“Cold, mostly cloudy day; brief midday clearing, with a moderate dry-air VPD shoulder. Prior completed plan self-score 4 vs anchor 1: limited moisture-safety success, but 218/259 guardrail events were held, so no causal benefit is claimed.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-04T18:00:00-07:00”,“end”:“2026-11-05T06:35:00-07:00”,“severity”:“medium”,“mitigation”:“Preserve stable heat through the 35F forecast low; avoid unnecessary cold-air exchange.”},{“kind”:“vpd_high”,“start”:“2026-11-04T12:30:00-07:00”,“end”:“2026-11-04T16:30:00-07:00”,“severity”:“low”,“mitigation”:“Band-coupled wet readiness near +0.05; restrained duty and fog only with dew margin >=8F.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:0.794,“new_value”:0… Result: Revised self-grade after the anchor review: the 17:00–00:19 window remains only partial evidence (score 66.8; binary temp/VPD 0%/100%; nominal cold 1.91 h; VPD-high/low and dew-risk 0 h), but 54 of 66 VPD-high guardrail events were held and only 12 dispatched. This undermines attribution: the absence of VPD-low/dew-risk does not demonstrate the planned moisture settings worked, and the short window did not include the forecast pre-dawn minimum. I reduce 5 to 3 because I over-credited safe observed outcomes despite weak actuation and incomplete forecast-window coverage. Daily costs, fixed-panel coverage, firmware-consumed targets, and crop outcome remain unavailable; no durable lesson. Score: 3/10
Hypothesis
Testing: Cold-night hold with modest live-edge moisture availability; observe dew margin, VPD-low carryover and heater/vent transition stability without claiming causal benefit. Expected outcome: Keep dew margin above 8F and VPD-low stress minimal overnight; limit cold/vent cycling through the 33F dawn. Resource costs and physical crop outcome remain unverified.
Conditions
59.0°F
22.0%
522.0 W/m²
45.0%
Cold cloudy freeze-adjacent night, low 33F near dawn; then clearing and dry air tomorrow. Current indoor VPD is at the 0.95 high edge with 11.9F dew margin. Prior evaluation gap: plan iris-20261104-0018 self-grade 4 vs anchor 1 (3 points); I credited safe dew/VPD-low results despite 2.77h cold and 1.36h VPD-high in only 6.3h, while anchor found no guardrail-backed efficacy. Keep attribution cautious.
Expected stress windows
Forecast low 33F; keep air exchange conservative and relay response stable through frost dawn.
Outdoor VPD falls to 0.13-0.27; avoid unnecessary wetting while retaining near-edge response.
Parameter rationale
Keep wet assist reachable within 0.05 kPa of the high edge, but reduce wetting below band; maintain an 8F dew floor.
Setpoints
Wednesday November 04
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:55 | hyst 0.1875 | evening_settle: cold forecast; conservative air exchange and |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:55 | s2 1.7875; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.996; all 1.196; pulse 33.75; gap 33.75; wt 1.75 | evening_settle: cold forecast; conservative air exchange and |
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | midnight_posture: preserve heat; limit low-VPD duty but keep |
| 05:30 | hyst 0.1875 | pre_dawn: retain frost protection and near-edge wet readines |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.8025000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.996; all 1.196; pulse 33.75; gap 37.5; wt 1.7166666666666668 | midnight_posture: preserve heat; limit low-VPD duty but keep |
| 05:30 | s2 1.7875; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.996; all 1.196; pulse 33.75; gap 33.75; wt 1.75 | pre_dawn: retain frost protection and near-edge wet readines |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:55 | band_track_fraction | initial 0 |
| 16:55 | cold_vent_guard_delta_f | initial 12 |
| 16:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:55 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:55 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:55 | dwell_gate_ms | initial 210000 |
| 16:55 | enthalpy_close | initial 1 |
| 16:55 | enthalpy_open | initial -2 |
| 16:55 | fog_escalation_kpa | initial 0.25 |
| 16:55 | heat_hysteresis | initial 1 |
| 16:55 | min_fog_off_s | initial 60 |
| 16:55 | min_fog_on_s | initial 63.75 |
| 16:55 | mist_backoff_s | initial 600 |
| 16:55 | mist_max_closed_vent_s | initial 600 |
| 16:55 | mist_thermal_relief_s | initial 90 |
| 16:55 | mister_all_delay_s | initial 75 |
| 16:55 | mister_engage_delay_s | initial 37.5 |
| 16:55 | mister_water_budget_gal | initial 120 |
| 16:55 | night_vpd_bias_kpa | initial 0 |
| 16:55 | outdoor_staleness_max_s | initial 600 |
| 16:55 | sw_dwell_gate_enabled | initial 1 |
| 16:55 | sw_fog_closes_vent | initial 1 |
| 16:55 | sw_mister_closes_vent | initial 0 |
| 16:55 | sw_summer_vent_enabled | initial 1 |
| 16:55 | temp_hysteresis | initial 1.6 |
| 16:55 | vent_exchange_fraction | initial 0.3 |
| 16:55 | vent_prefer_dp_delta_f | initial 6 |
| 16:55 | vent_prefer_temp_delta_f | initial 8 |
| 16:55 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | min_fog_off_s | 60 → 66 |
| 00:00 | min_fog_on_s | 63.75 → 61.5 |
| 05:30 | min_fog_off_s | 66 → 60 |
| 05:30 | min_fog_on_s | 61.5 → 63.75 |
End-of-Day Summary
Climate
59.1–81.4°F; avg 68.0°F
0.43–1.64 kPa; avg 0.81 kPa
43.1–76.7%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 5.6h
- Cold stress (<55°F): 17.1h
Economics
Not available
USD 2.42
USD 0.040
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 15 min | Primary exhaust runtime. |
| Fan 2 | 15 min | Secondary exhaust runtime. |
| Vent | 15 min | Intake vent runtime. |
| Fog | 6 min | Fogger runtime. |
| Heat 1 electric | 1309 min | Electric heater runtime. |
| Heat 2 gas | 233 min | Gas heater runtime. |
| Grow lights | 1190 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.01h | Center mister runtime. |
Water
- Total: 9 gal
- Mister: 4 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 68% | 11 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 74% | 7 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 73% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Large hanging plants (likely citrus or similar) in the central/west area. Foliage appears dense and turgid with no obvious signs of wilting or leaf drop. || Large potted plant visible on the left (west) side. Foliage appears dense and healthy. Soil moisture data is missing, but visual inspection shows no immediate signs of stress. || Large potted plant with exposed roots in the center. Leaves appear green and healthy, though the exposed root system suggests it may be in a transitional phase or requires specific humidity management. || The tree appears robust with dense foliage. The leaves are bright white in the IR image, indicating high reflectivity and likely good turgor pressure. No obvious signs of pest damage or leaf drop. || Vegetative growth is visible in the potted plants on the lower left shelves. Foliage is green and turgid. || [leaf yellowing] Large potted tree visible on the right side (west). Some lower leaves appear yellowed or brown, possibly indicating nutrient deficien
Hanging baskets visible in the center background. Roots appear exposed and healthy, typical for Vanda. No obvious signs of wilting or discoloration. || Hanging baskets visible in the center background. Roots appear white and healthy, indicating good hydration and air circulation. No visible yellowing or root rot. || Hanging baskets visible in the center background. Roots appear white and healthy. Foliage is green and turgid. || Hanging baskets visible in the upper center of the frame. Roots appear dense and healthy. No visible signs of wilting or leaf drop. || [low light, low temperature] Hanging baskets visible in the center. Roots appear exposed and healthy, but the 61.1°F temperature is on the cool side for Vandas, and 0 lux indicates the lights are off. || [root exposure, potential dehydration] Hanging baskets visible in upper center. Roots appear exposed and somewhat dry, which is typical for Vanda but requires monitoring given the 0 lux light cycle (nighttime). || [root exposure]
Seedlings in blue trays on the left-side shelving appear upright and green. No visible wilting or yellowing. || Seedlings visible on the left-side shelving units (east zone). Plants appear upright and intact, though specific leaf color cannot be determined due to monochrome imaging. || [low light exposure, potential nutrient deficiency] Seedlings appear small and delicate. The 0 lux light reading suggests they are currently in a dark cycle or the light sensors are not active, which is normal for night but critical for growth if prolonged. No visible wilting or yellowing in the infrared spectrum. || [low_soil_moisture] Seedlings visible in blue trays on the left rack. Soil moisture in the south zone is low (19.5%), which may impact these plants if they are located in that area.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 72.9°F | 1.02 kPa | 63.2% |
| 11:00 | 75.2°F | 1.13 kPa | 62.1% |
| 12:00 | 76.4°F | 1.03 kPa | 66.8% |
| 13:00 | 76.5°F | 1.16 kPa | 62.8% |
| 14:00 | 79.1°F | 1.16 kPa | 65.8% |
| 15:00 | 80.7°F | 1.17 kPa | 67.4% |
| 16:00 | 74.8°F | 0.94 kPa | 68.1% |
| 17:00 | 72.9°F | 0.94 kPa | 66.1% |
| 18:00 | 69.7°F | 0.82 kPa | 66.8% |
| 19:00 | 68.8°F | 0.90 kPa | 62.3% |
| 20:00 | 65.8°F | 0.74 kPa | 66.1% |
| 21:00 | 66.2°F | 0.75 kPa | 65.9% |
| 22:00 | 63.4°F | 0.43 kPa | 78.6% |
| 23:00 | 61.6°F | 0.42 kPa | 77.9% |
| 00:00 | 60.3°F | 0.46 kPa | 74.2% |
| 01:00 | 60.6°F | 0.48 kPa | 73.4% |
| 02:00 | 60.3°F | 0.51 kPa | 71.5% |
| 03:00 | 60.7°F | 0.54 kPa | 70.5% |
| 04:00 | 61.8°F | 0.57 kPa | 69.5% |
| 05:00 | 62.8°F | 0.65 kPa | 66.9% |
| 06:00 | 63.7°F | 0.70 kPa | 65.3% |
| 07:00 | 66.3°F | 0.83 kPa | 62.5% |
| 08:00 | 68.5°F | 0.93 kPa | 60.8% |
| 09:00 | 70.3°F | 1.02 kPa | 59.6% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-29 | 0.0h | 6.5h | 17.0h |
| 2026-10-30 | 0.0h | 4.2h | 16.7h |
| 2026-10-31 | 0.0h | 4.3h | 17.0h |
| 2026-11-01 | 0.0h | 4.8h | 17.8h |
| 2026-11-02 | 0.0h | 6.7h | 16.5h |
| 2026-11-03 | 0.0h | 6.3h | 16.8h |
| 2026-11-04 | 0.0h | 5.6h | 17.1h |