November 05, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
3
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261105-0018. Resolved 00:19 MDT. |
| Morning planning cycle | 06:36 | SUNRISE | plan_written | Wrote public plan iris-20261105-0638. Resolved 06:41 MDT. |
| Forecast deviation | 07:05 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261105-0705. Resolved 07:09 MDT. |
| Solar peak planning checkpoint | 11:45 | SOLAR_MAX | acked | Acknowledged: Solar measured 600 W/m² vs forecast peak 515 (raw +85; bias-corrected forecast ~468), but indoor VPD is now 0.90 kPa, down from brief 1.47/1.32 spikes, with RH 71%, temp 75.8°F, dew margin 10.4°F, and current target-band error 0. The active plan covers the afternoon; cooldown/high humidity and lesson 103 argue against extra wetting without persistent live VPD-high stress, so no tunable change. Resolved 11:47 MDT. |
| Peak Stress | 13:46 | TRANSITION | acked | Acknowledged: Peak-stress checkpoint: indoor 78.9°F, VPD 1.19 kPa, dew margin 12.9°F; all relays are off and fresh controller proof reports IDLE with zero VPD band error. Forecast VPD is near this level with cooling daylight ahead. No rising heat/VPD error or justified change beyond the existing band-coupled posture and guardrail-clamped 30s mister gap; leave tunables unchanged. Resolved 13:46 MDT. |
| Decline | 15:55 | TRANSITION | acked | Acknowledged: No immediate retune: live house VPD is 0.93 kPa against the 0.99 high edge and dew margin is 10.1°F; only east is a modest dry outlier at 1.12. Equipment is idle, and the active plan already steps to a mild taper at 17:00 then a stronger evening taper at 19:30 as outdoor VPD and temperature fall toward a 33–34°F pre-dawn low. Keep that planned recovery shoulder rather than override it now. Resolved 15:56 MDT. |
| Evening planning cycle | 16:54 | SUNSET | plan_written | Wrote public plan iris-20261105-1654. Resolved 16:58 MDT. |
🌅 Morning Cycle (12:19 AM) — iris-20261105-0018
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261104-1655
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:59,“outdoor_rh_min_pct”:22,“solar_peak_w_m2”:522,“cloud_cover_avg_pct”:45,“notes”:“Cold cloudy freeze-adjacent night, low 33F near dawn; then clearing and dry air tomorrow. Current indoor VPD is at the 0.95 high edge with 11.9F dew margin. Prior evaluation gap: plan iris-20261104-0018 self-grade 4 vs anchor 1 (3 points); I credited safe dew/VPD-low results despite 2.77h cold and 1.36h VPD-high in only 6.3h, while anchor found no guardrail-backed efficacy. Keep attribution cautious.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-04T20:00:00-07:00”,“end”:“2026-11-05T07:00:00-07:00”,“severity”:“high”,“mitigation”:“Forecast low 33F; keep air exchange conservative and relay response stable through frost dawn… Result: Revised after anchor review: the plan’s main cold objective was not achieved well enough to justify a 4; the partial window still had 1.79 h nominal cold stress and 0% binary temperature compliance. The 0 h VPD-high/VPD-low/dew-risk result is a limited safety outcome, not demonstrated plan efficacy. Window covered only ~0.265 of a day; cost, fixed-panel coverage, crop outcome, and firmware-consumed targets remain unavailable. No durable lesson. Score: 3/10
Hypothesis
Testing: Cold-dawn stability with a restrained, band-coupled daytime moisture ramp; judge only from later plan-scoped evidence. Expected outcome: Keep pre-dawn dew margin at or above 8F without unnecessary wetting or cold-air exchange; make modest wet assist available only if live VPD approaches/exceeds its served high edge during the dry ramp. No cost or crop-benefit claim.
Setpoints
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21250000000000002 | Cold overnight; current VPD below served high edge, retain h |
| 04:30 | hyst 0.21250000000000002 | Hold conservative air exchange through the 33F dawn; keep we |
| 07:00 | hyst 0.20750000000000002 | Sunrise ramp starts cold/cloudy; warm first, then preserve r |
| 10:30 | hyst 0.2025 | Pre-position modest wet assist ahead of noon VPD rise; do no |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.91; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 60; wt 1.4000000000000001 | Cold overnight; current VPD below served high edge, retain h |
| 04:30 | s2 1.91; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 60; wt 1.4000000000000001 | Hold conservative air exchange through the 33F dawn; keep we |
| 07:00 | s2 1.7775; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 48.75; wt 1.5666666666666669 | Sunrise ramp starts cold/cloudy; warm first, then preserve r |
| 10:30 | s2 1.6887500000000002; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 33.75; gap 37.5; wt 1.6999999999999997 | Pre-position modest wet assist ahead of noon VPD rise; do no |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 12 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8.5 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 285000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.35 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 102 |
| 00:16 | min_fog_on_s | initial 48 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 97.5 |
| 00:16 | mister_engage_delay_s | initial 48.75 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.05 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 6 |
| 00:16 | vent_prefer_temp_delta_f | initial 8 |
| 00:16 | vpd_watch_dwell_s | initial 71.25 |
| 07:00 | direct_wet_stress_min_dew_margin_f | 8.5 → 8 |
| 07:00 | dwell_gate_ms | 285000 → 270000 |
| 07:00 | fog_escalation_kpa | 0.35 → 0.3 |
| 07:00 | min_fog_off_s | 102 → 84 |
| 07:00 | min_fog_on_s | 48 → 54.75 |
| 07:00 | mister_all_delay_s | 97.5 → 93 |
| 07:00 | mister_engage_delay_s | 48.75 → 46.5 |
| 07:00 | temp_hysteresis | 2.05 → 1.96 |
| 07:00 | vpd_watch_dwell_s | 71.25 → 67.5 |
| 10:30 | dwell_gate_ms | 270000 → 255000 |
| 10:30 | fog_escalation_kpa | 0.3 → 0.25 |
| 10:30 | min_fog_off_s | 84 → 66 |
| 10:30 | min_fog_on_s | 54.75 → 61.5 |
| 10:30 | mister_all_delay_s | 93 → 88.5 |
| 10:30 | mister_engage_delay_s | 46.5 → 44.25 |
| 10:30 | temp_hysteresis | 1.96 → 1.87 |
| 10:30 | vpd_watch_dwell_s | 67.5 → 63.75 |
🌅 Morning Cycle (6:41 AM) — iris-20261105-0638
validated
2/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261104-1655
Result: This plan governed only about 0.020 day (~29 minutes) before the next plan replaced it, so its planned midday VPD and overnight cold windows were not observed under this plan. The scoped row lists planner_score 72.8, contract-2 binary temp/VPD 30.6%/62.0%, nominal cold stress 0.22h and VPD-high 0.12h, but the scorecard’s coverage is unverified and those short-window values do not establish plan attribution. Today’s cost terms, fixed-panel/physical crop evidence, and crop outcomes are unavailable. No durable lesson or efficacy claim is supported. Score: 2/10
Hypothesis
Testing: Test conservative dawn, moderate band-coupled midday wet assist, and stable cold-night posture; judge only from scoped evidence and guardrail delivery. Expected outcome: Keep plan-window VPD-high below 3h, VPD-low below 0.5h, and dp-risk at 0h if feasible; anticipate cold-band load near 33F. No cost or crop-benefit claim.
Conditions
60.0°F
24.0%
520.0 W/m²
49.2%
Today: 36-60F, overcast dawn/evening with a clear midday, outdoor VPD peak 1.33 kPa; next pre-dawn low 33F. Current house VPD 0.81 kPa and dew margin 13.4F. Prior evening plan revised to 3 vs anchor 1 after 54/66 VPD guardrail events were held, so efficacy attribution remains weak.
Expected stress windows
Keep moisture thresholds band-coupled (+0.05/+0.25); moderate duty, fog only for persistent excess with >=9F dew margin.
Conservative air exchange and stable heat through the forecast 33F minimum; no unnecessary wetting.
Parameter rationale
Keep first wet assist close to the live high edge without watering while the house remains in-band.
Allow all-zone rotation only after a further 0.25 kPa excess, avoiding unnecessary broad wetting.
Reserve heavy fog for persistent edge exceedance while moderate mist duty handles initial demand.
Setpoints
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | hyst 0.21250000000000002 | Dawn near 36-40F; preserve heat and keep wet assist near-edg |
| 09:30 | hyst 0.2025 | Morning dry ramp begins; keep initial wetting band-coupled a |
| 12:00 | hyst 0.2025 | Clear midday, RH 24-29%, outdoor VPD peaks 1.33; allow moder |
| 16:30 | hyst 0.20750000000000002 | Solar and outdoor VPD decline; taper duty gradually while re |
| 19:30 | hyst 0.21750000000000003 | Prepare for 33F pre-dawn low; keep exchange conservative and |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 56.25; wt 1.4 | Dawn near 36-40F; preserve heat and keep wet assist near-edg |
| 09:30 | s2 1.8475000000000001; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 48.75; wt 1.5 | Morning dry ramp begins; keep initial wetting band-coupled a |
| 12:00 | s2 1.8175000000000001; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 37.5; gap 41.25; wt 1.6333333333333333 | Clear midday, RH 24-29%, outdoor VPD peaks 1.33; allow moder |
| 16:30 | s2 1.95; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 52.5; wt 1.4666666666666666 | Solar and outdoor VPD decline; taper duty gradually while re |
| 19:30 | s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.9560000000000001; all 1.1560000000000001; pulse 30; gap 60; wt 1.3 | Prepare for 33F pre-dawn low; keep exchange conservative and |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:30 | band_track_fraction | initial 0 |
| 06:30 | cold_vent_guard_delta_f | initial 12 |
| 06:30 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:30 | direct_wet_stress_min_dew_margin_f | initial 9 |
| 06:30 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:30 | dwell_gate_ms | initial 285000 |
| 06:30 | enthalpy_close | initial 1 |
| 06:30 | enthalpy_open | initial -2 |
| 06:30 | fog_escalation_kpa | initial 0.35 |
| 06:30 | heat_hysteresis | initial 1 |
| 06:30 | min_fog_off_s | initial 96 |
| 06:30 | min_fog_on_s | initial 50.25 |
| 06:30 | mist_backoff_s | initial 600 |
| 06:30 | mist_max_closed_vent_s | initial 600 |
| 06:30 | mist_thermal_relief_s | initial 90 |
| 06:30 | mister_all_delay_s | initial 97.5 |
| 06:30 | mister_engage_delay_s | initial 48.75 |
| 06:30 | mister_water_budget_gal | initial 120 |
| 06:30 | night_vpd_bias_kpa | initial 0 |
| 06:30 | outdoor_staleness_max_s | initial 600 |
| 06:30 | sw_dwell_gate_enabled | initial 1 |
| 06:30 | sw_fog_closes_vent | initial 1 |
| 06:30 | sw_mister_closes_vent | initial 0 |
| 06:30 | sw_summer_vent_enabled | initial 1 |
| 06:30 | temp_hysteresis | initial 2.05 |
| 06:30 | vent_exchange_fraction | initial 0.3 |
| 06:30 | vent_prefer_dp_delta_f | initial 5 |
| 06:30 | vent_prefer_temp_delta_f | initial 8 |
| 06:30 | vpd_watch_dwell_s | initial 71.25 |
| 09:30 | cold_vent_guard_delta_f | 12 → 10 |
| 09:30 | dwell_gate_ms | 285000 → 255000 |
| 09:30 | fog_escalation_kpa | 0.35 → 0.3 |
| 09:30 | min_fog_off_s | 96 → 84 |
| 09:30 | min_fog_on_s | 50.25 → 54.75 |
| 09:30 | mister_all_delay_s | 97.5 → 88.5 |
| 09:30 | mister_engage_delay_s | 48.75 → 44.25 |
| 09:30 | temp_hysteresis | 2.05 → 1.87 |
| 09:30 | vent_prefer_dp_delta_f | 5 → 4 |
| 09:30 | vent_prefer_temp_delta_f | 8 → 6 |
| 09:30 | vpd_watch_dwell_s | 71.25 → 63.75 |
| 12:00 | fog_escalation_kpa | 0.3 → 0.25 |
| 12:00 | min_fog_off_s | 84 → 72 |
| 12:00 | min_fog_on_s | 54.75 → 59.25 |
| 16:30 | cold_vent_guard_delta_f | 10 → 11 |
| 16:30 | dwell_gate_ms | 255000 → 270000 |
| 16:30 | fog_escalation_kpa | 0.25 → 0.35 |
| 16:30 | min_fog_off_s | 72 → 90 |
| 16:30 | min_fog_on_s | 59.25 → 52.5 |
| 16:30 | mister_all_delay_s | 88.5 → 93 |
| 16:30 | mister_engage_delay_s | 44.25 → 46.5 |
| 16:30 | temp_hysteresis | 1.87 → 1.96 |
| 16:30 | vent_prefer_dp_delta_f | 4 → 5 |
| 16:30 | vent_prefer_temp_delta_f | 6 → 7 |
| 16:30 | vpd_watch_dwell_s | 63.75 → 67.5 |
| 19:30 | cold_vent_guard_delta_f | 11 → 12 |
| 19:30 | dwell_gate_ms | 270000 → 300000 |
| 19:30 | fog_escalation_kpa | 0.35 → 0.45 |
| 19:30 | min_fog_off_s | 90 → 108 |
| 19:30 | min_fog_on_s | 52.5 → 45.75 |
| 19:30 | mister_all_delay_s | 93 → 102 |
| 19:30 | mister_engage_delay_s | 46.5 → 51 |
| 19:30 | temp_hysteresis | 1.96 → 2.14 |
| 19:30 | vent_prefer_temp_delta_f | 7 → 8 |
| 19:30 | vpd_watch_dwell_s | 67.5 → 75 |
🌅 Morning Cycle (7:09 AM) — iris-20261105-0705
validated
3/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261104-1655
Result: Scoped WINDOW SCORECARD for iris-20261105-0705 (0.409 day): planner_score 76.5, binary both-axis compliance 6.5%, temp 23.1%, VPD 73.0%, nominal cold stress 7.05 h and VPD-high 2.47 h; heat/VPD-low/dew-risk 0 h. The plan’s cautious cold-protection/live-edge posture avoided recorded dew/VPD-low stress but did not prevent substantial cold stress and left notable VPD-high exposure, so its main protective objective was only partly met. Whole-day Nov 5 contract-2 scorecard was 76.5 with 17.47 h cold and 6.05 h VPD-high; costs/resources unavailable. Coverage is unverified; targets are historical desired setpoints, not confirmed consumed targets, and physical crop outcome is unavailable. No causal efficacy claim. Score: 3/10
Hypothesis
Testing: Test conservative dawn, moderate band-coupled midday wet assist, and stable cold-night posture; judge only from scoped evidence and guardrail delivery. Expected outcome: Keep plan-window VPD-high below 3h, VPD-low below 0.5h, and dp-risk at 0h if feasible; anticipate cold-band load near 33F. No cost or crop-benefit claim.
Setpoints
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:05 | hyst 0.20750000000000002 | Humid dawn matches RH underforecast bias; preserve heat and |
| 10:30 | hyst 0.20750000000000002 | Dry ramp is forecast-only; moderate duty remains gated by li |
| 13:30 | hyst 0.20750000000000002 | Peak forecast is modest; retain band-coupled assist but do n |
| 17:00 | hyst 0.20750000000000002 | Keep recovery assist available through the dry shoulder; unw |
| 19:30 | hyst 0.20750000000000002 | Cold night ahead; avoid unnecessary wetting and outdoor exch |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:05 | s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 30; gap 41.25; wt 1.5333333333333332 | Humid dawn matches RH underforecast bias; preserve heat and |
| 10:30 | s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 30; gap 41.25; wt 1.5666666666666669 | Dry ramp is forecast-only; moderate duty remains gated by li |
| 13:30 | s2 1.8175000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 33.75; gap 41.25; wt 1.6 | Peak forecast is modest; retain band-coupled assist but do n |
| 17:00 | s2 1.86125; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 30; gap 41.25; wt 1.5666666666666669 | Keep recovery assist available through the dry shoulder; unw |
| 19:30 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 30; gap 48.75; wt 1.4333333333333333 | Cold night ahead; avoid unnecessary wetting and outdoor exch |
Friday November 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | hyst 0.20750000000000002 | Frost dawn remains forecast; retain stable heat posture and |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:30 | s2 1.935; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9820000000000001; all 1.182; pulse 30; gap 48.75; wt 1.4333333333333333 | Frost dawn remains forecast; retain stable heat posture and |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 07:05 | band_track_fraction | initial 0 |
| 07:05 | cold_vent_guard_delta_f | initial 12 |
| 07:05 | cool_stage2_exit_hysteresis_f | initial 1 |
| 07:05 | direct_wet_stress_min_dew_margin_f | initial 9 |
| 07:05 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 07:05 | dwell_gate_ms | initial 270000 |
| 07:05 | enthalpy_close | initial 1 |
| 07:05 | enthalpy_open | initial -2 |
| 07:05 | fog_escalation_kpa | initial 0.3 |
| 07:05 | heat_hysteresis | initial 1 |
| 07:05 | min_fog_off_s | initial 72 |
| 07:05 | min_fog_on_s | initial 59.25 |
| 07:05 | mist_backoff_s | initial 600 |
| 07:05 | mist_max_closed_vent_s | initial 600 |
| 07:05 | mist_thermal_relief_s | initial 90 |
| 07:05 | mister_all_delay_s | initial 93 |
| 07:05 | mister_engage_delay_s | initial 46.5 |
| 07:05 | mister_water_budget_gal | initial 120 |
| 07:05 | night_vpd_bias_kpa | initial 0 |
| 07:05 | outdoor_staleness_max_s | initial 600 |
| 07:05 | sw_dwell_gate_enabled | initial 1 |
| 07:05 | sw_fog_closes_vent | initial 1 |
| 07:05 | sw_mister_closes_vent | initial 0 |
| 07:05 | sw_summer_vent_enabled | initial 1 |
| 07:05 | temp_hysteresis | initial 1.96 |
| 07:05 | vent_exchange_fraction | initial 0.3 |
| 07:05 | vent_prefer_dp_delta_f | initial 6 |
| 07:05 | vent_prefer_temp_delta_f | initial 8 |
| 07:05 | vpd_watch_dwell_s | initial 67.5 |
| 13:30 | fog_escalation_kpa | 0.3 → 0.25 |
| 17:00 | fog_escalation_kpa | 0.25 → 0.3 |
| 19:30 | direct_wet_stress_min_dew_margin_f | 9 → 10 |
| 19:30 | fog_escalation_kpa | 0.3 → 0.4 |
| 19:30 | min_fog_off_s | 72 → 84 |
| 19:30 | min_fog_on_s | 59.25 → 54.75 |
🌆 Evening Cycle (4:58 PM) — iris-20261105-1654
validated
6/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261105-0705
Previous hypothesis: Observed outdoor RH is 78.4% versus 53.0% forecast (+25.39 pp), but this follows the persistent low-biased RH forecast pattern (forecast-minus-observed historically negative); diagnose forecast miss, not a new regime. Live indoor conditions are 63.5°F/VPD 0.72 kPa with 12.4°F dew margin, within the current 63.32–73.45°F and 0.378–0.928 kPa corridors. Heat is active; vent, fans, fog, and misters are off. Preserve cold protection and current band-edge moisture readiness; use moderate midday assist only for live excess, since the forecast dry ramp is uncertain. Prior completed plan iris-20261105-0018 was revised to 3 vs anchor 1: 1.79 h nominal cold stress and 0% binary temperature compliance outweigh zero moisture/dew-risk hours; no efficacy or durable lesson is established. Result: Plan-window evidence only (0.307 day, about 7.4 h): contract-2 planner_score 69.6; binary temp/VPD compliance 94.9%/39.2%; nominal stress cold 0.10 h, VPD-low 1.24 h, heat/VPD-high/dew-risk 0. The frost-night stability objective was largely met, while VPD compliance remained weak and VPD-low was the main window miss. Whole Nov 5 context: score 76.4, temp/VPD 94.1%/49.3%, cold 1.42 h, VPD-high 0.67 h, VPD-low 11.42 h; costs unavailable. Realized dryout read: 2 ineffective and 2 insufficient-evidence episodes, safety gate pass; this is not evidence of effective dry-out or causal benefit. Window metrics use historical desired bands, coverage is unverified, and physical crop outcomes are unavailable. Score: 6/10
Hypothesis
Conditions
53.0°F
33.0%
0.0 W/m²
54.0%
Cold evening, turning overcast overnight; forecast low 35F before dawn. Indoor VPD has recovered to 0.79 kPa with 10F dew margin. Main challenge is stable frost-night heating without cold-air cycling or overnight moisture overshoot; the next dry/solar ramp is after this plan.
Expected stress windows
Conservative outdoor exchange and stable heating; reduce ordinary churn while preserving safety preemption.
Parameter rationale
Reduce ordinary heat/vent oscillation without suppressing thermal or safety protection.
Setpoints
Thursday November 05
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:55 | hyst 0.2125 | evening_settle: VPD is below its high edge; preserve heat an |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:55 | s2 1.93; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.996; all 1.196; pulse 30; gap 60; wt 1.3666666666666667 | evening_settle: VPD is below its high edge; preserve heat an |
Friday November 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.22249999999999998 | midnight_posture: 39F and rising humidity favor heat retenti |
| 05:30 | hyst 0.2125 | pre_dawn: hold heat through frost; restore only live band-ed |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.99; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.996; all 1.196; pulse 30; gap 60; wt 1.2 | midnight_posture: 39F and rising humidity favor heat retenti |
| 05:30 | s2 1.93; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.996; all 1.196; pulse 30; gap 60; wt 1.4 | pre_dawn: hold heat through frost; restore only live band-ed |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:55 | band_track_fraction | initial 0 |
| 16:55 | cold_vent_guard_delta_f | initial 14 |
| 16:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:55 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:55 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:55 | dwell_gate_ms | initial 285000 |
| 16:55 | enthalpy_close | initial 1 |
| 16:55 | enthalpy_open | initial -2 |
| 16:55 | fog_escalation_kpa | initial 0.35 |
| 16:55 | heat_hysteresis | initial 1 |
| 16:55 | min_fog_off_s | initial 102 |
| 16:55 | min_fog_on_s | initial 48 |
| 16:55 | mist_backoff_s | initial 600 |
| 16:55 | mist_max_closed_vent_s | initial 600 |
| 16:55 | mist_thermal_relief_s | initial 90 |
| 16:55 | mister_all_delay_s | initial 97.5 |
| 16:55 | mister_engage_delay_s | initial 48.75 |
| 16:55 | mister_water_budget_gal | initial 120 |
| 16:55 | night_vpd_bias_kpa | initial 0 |
| 16:55 | outdoor_staleness_max_s | initial 600 |
| 16:55 | sw_dwell_gate_enabled | initial 1 |
| 16:55 | sw_fog_closes_vent | initial 1 |
| 16:55 | sw_mister_closes_vent | initial 0 |
| 16:55 | sw_summer_vent_enabled | initial 1 |
| 16:55 | temp_hysteresis | initial 2.05 |
| 16:55 | vent_exchange_fraction | initial 0.3 |
| 16:55 | vent_prefer_dp_delta_f | initial 8 |
| 16:55 | vent_prefer_temp_delta_f | initial 10 |
| 16:55 | vpd_watch_dwell_s | initial 71.25 |
| 00:00 | cold_vent_guard_delta_f | 14 → 15 |
| 00:00 | dwell_gate_ms | 285000 → 315000 |
| 00:00 | fog_escalation_kpa | 0.35 → 0.4 |
| 00:00 | min_fog_off_s | 102 → 126 |
| 00:00 | min_fog_on_s | 48 → 39 |
| 00:00 | mister_all_delay_s | 97.5 → 106.5 |
| 00:00 | mister_engage_delay_s | 48.75 → 53.25 |
| 00:00 | temp_hysteresis | 2.05 → 2.23 |
| 00:00 | vent_prefer_dp_delta_f | 8 → 10 |
| 00:00 | vent_prefer_temp_delta_f | 10 → 12 |
| 00:00 | vpd_watch_dwell_s | 71.25 → 78.75 |
| 05:30 | dwell_gate_ms | 315000 → 285000 |
| 05:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 05:30 | min_fog_off_s | 126 → 102 |
| 05:30 | min_fog_on_s | 39 → 48 |
| 05:30 | mister_all_delay_s | 106.5 → 97.5 |
| 05:30 | mister_engage_delay_s | 53.25 → 48.75 |
| 05:30 | temp_hysteresis | 2.23 → 2.05 |
| 05:30 | vpd_watch_dwell_s | 78.75 → 71.25 |
End-of-Day Summary
Climate
59.2–82.9°F; avg 68.2°F
0.50–1.74 kPa; avg 0.84 kPa
38.6–73.0%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 0.7h
- Cold stress (<55°F): 1.4h
Economics
Not available
USD 2.64
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 30 min | Primary exhaust runtime. |
| Fan 2 | 33 min | Secondary exhaust runtime. |
| Vent | 30 min | Intake vent runtime. |
| Fog | 16 min | Fogger runtime. |
| Heat 1 electric | 1211 min | Electric heater runtime. |
| Heat 2 gas | 254 min | Gas heater runtime. |
| Grow lights | 1060 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.03h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Lime Tree | west | 75% | 2 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| Vanda Orchids | center | 72% | 5 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
| pepper | east | 70% | 1 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Potted tree visible on the right side (west zone). Foliage appears dense and intact. No visible signs of pest damage or leaf loss. || Visible on the left-side shelving units. Plants appear upright and healthy, though specific leaf details are obscured by the black-and-white infrared imaging.
Hanging Vanda orchids visible in the center background. Roots appear white and healthy. Foliage is green and turgid. No visible wilting or yellowing. || Hanging baskets visible in the center zone. Roots appear well-developed and foliage is upright. No visible signs of wilting or leaf drop. || Hanging baskets visible in the center zone. Roots appear white and healthy. No immediate signs of wilting or leaf discoloration visible from this distance. || Hanging baskets visible in the upper center. Roots appear exposed and healthy in the infrared spectrum. No obvious signs of wilting or leaf drop. || [exposed roots, potential dehydration risk] Hanging baskets visible in the center zone. Roots are fully exposed and appear dry. While typical for Vanda, the lack of visible moisture on the roots combined with the 82°F temperature suggests a need for frequent misting.
Located on the right-side shelving units near the PVC pipe infrastructure. Seedlings appear established in their containers.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 72.9°F | 1.02 kPa | 63.0% |
| 11:00 | 75.4°F | 1.17 kPa | 61.1% |
| 12:00 | 76.4°F | 1.11 kPa | 64.4% |
| 13:00 | 75.3°F | 1.22 kPa | 58.4% |
| 14:00 | 79.0°F | 1.16 kPa | 65.8% |
| 15:00 | 75.5°F | 0.96 kPa | 68.1% |
| 16:00 | 74.4°F | 0.98 kPa | 66.3% |
| 17:00 | 72.4°F | 0.92 kPa | 66.2% |
| 18:00 | 71.1°F | 0.88 kPa | 66.0% |
| 19:00 | 67.5°F | 0.73 kPa | 68.5% |
| 20:00 | 67.6°F | 0.75 kPa | 67.5% |
| 21:00 | 65.0°F | 0.64 kPa | 69.6% |
| 22:00 | 63.6°F | 0.58 kPa | 71.1% |
| 23:00 | 62.3°F | 0.55 kPa | 71.7% |
| 00:00 | 60.8°F | 0.53 kPa | 71.2% |
| 01:00 | 60.7°F | 0.54 kPa | 70.2% |
| 02:00 | 60.0°F | 0.55 kPa | 69.2% |
| 03:00 | 61.2°F | 0.59 kPa | 68.2% |
| 04:00 | 61.3°F | 0.61 kPa | 67.2% |
| 05:00 | 62.8°F | 0.69 kPa | 64.6% |
| 06:00 | 64.0°F | 0.76 kPa | 62.6% |
| 07:00 | 65.9°F | 0.87 kPa | 60.3% |
| 08:00 | 68.4°F | 0.99 kPa | 58.2% |
| 09:00 | 70.5°F | 1.08 kPa | 57.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-30 | 0.0h | 0.0h | 0.5h |
| 2026-10-31 | 0.0h | 0.0h | 0.2h |
| 2026-11-01 | 0.0h | 0.0h | 0.5h |
| 2026-11-02 | 0.0h | 0.0h | 0.5h |
| 2026-11-03 | 0.0h | 0.1h | 0.3h |
| 2026-11-04 | 0.0h | 0.4h | 0.8h |
| 2026-11-05 | 0.0h | 0.7h | 1.4h |