November 06, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
43
3
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261106-0016. Resolved 00:19 MDT. |
| Morning planning cycle | 06:38 | SUNRISE | plan_written | Wrote public plan iris-20261106-0639. Resolved 06:42 MDT. |
| Forecast deviation | 08:54 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261106-0854. Resolved 08:58 MDT. |
| Solar peak planning checkpoint | 11:46 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 11:48 MDT. |
| Peak Stress | 13:46 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 13:49 MDT. |
| Decline | 15:54 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline | 15:56 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline | 15:58 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:00 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:02 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:04 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:06 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:08 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:10 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:12 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:14 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:16 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:18 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:20 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:22 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:24 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:26 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:28 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:30 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:32 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:34 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:36 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:38 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:40 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:42 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:44 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:46 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:48 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:50 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:52 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:54 | TRANSITION | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 16:56 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Decline (catch-up) | 16:58 | TRANSITION | acked | Acknowledged: No tunable change: current VPD is 0.78 kPa (east 0.94), dew margin 9.8°F, and fog/misters/vent are off; the active plan already has a 17:00 decline step that raises mister thresholds, widens pulse gap, and raises fog escalation for the cold night. Maintain existing plan and avoid additional wetting changes. Resolved 16:59 MDT. |
| Evening planning cycle (catch-up) | 17:06 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle (catch-up) | 17:08 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle (catch-up) | 17:10 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle (catch-up) | 17:12 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle (catch-up) | 17:14 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
🌅 Morning Cycle (12:19 AM) — iris-20261106-0016
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261105-1654
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:53,“outdoor_rh_min_pct”:33,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:54,“notes”:“Cold evening, turning overcast overnight; forecast low 35F before dawn. Indoor VPD has recovered to 0.79 kPa with 10F dew margin. Main challenge is stable frost-night heating without cold-air cycling or overnight moisture overshoot; the next dry/solar ramp is after this plan.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-05T20:00:00-07:00”,“end”:“2026-11-06T06:30:00-07:00”,“severity”:“high”,“mitigation”:“Conservative outdoor exchange and stable heating; reduce ordinary churn while preserving safety preemption.”}],“rationale”:[{“parameter”:“temp_hysteresis”,“old_value”:1.96,“new_value”:2.2,“forecast_anchor”:“35F pre-dawn frost risk; heat1 and heat2 each showed 40 and 39 state transitions in the prior 24h… Result: Scoped window 2026-11-06 00:19–06:42 (0.266 day): contract-2 planner score 71.6; binary both-axis compliance 31.1%, temperature 94.2%, VPD 32.0%; nominal stress was 0.13 h cold and 1.55 h VPD-low, with 0 heat and 0 VPD-high. The overnight frost-protection objective was mostly met on temperature, but the low-wet posture did not prevent notable VPD-low exposure; the window is short and coverage-limited, and there is no qualified physical crop outcome, reliable resource evidence, or confirmed consumed-target attribution. No causal efficacy or durable lesson established. Score: 4/10
Hypothesis
Testing: No formal experiment; conservative overnight bridge with a live-edge daytime handoff. Expected outcome: Overnight cold stress <4h, zero dew-risk/VPD-low hours, and forecast-window VPD-high <3h with bounded wet assist available at the live edge; verify against scoped evidence.
Setpoints
Friday November 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.21750000000000003 | Post-midnight frost: retain heat, avoid unnecessary exchange |
| 03:00 | hyst 0.21750000000000003 | Pre-dawn low near 33°F; stable heat and dew protection take |
| 06:30 | hyst 0.21250000000000002 | Sunrise ramp remains cold and overcast; keep mist band-coupl |
| 10:00 | hyst 0.20750000000000002 | Early-day VPD climbs toward 1 kPa; modest wet assist only if |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 56.25; wt 1.38 | Post-midnight frost: retain heat, avoid unnecessary exchange |
| 03:00 | s2 1.905; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 56.25; wt 1.38 | Pre-dawn low near 33°F; stable heat and dew protection take |
| 06:30 | s2 1.875; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 30; gap 48.75; wt 1.4866666666666666 | Sunrise ramp remains cold and overcast; keep mist band-coupl |
| 10:00 | s2 1.845; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.794; all 1; pulse 31.5; gap 41.25; wt 1.58 | Early-day VPD climbs toward 1 kPa; modest wet assist only if |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 15 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 300000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.25 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 96 |
| 00:16 | min_fog_on_s | initial 50.25 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 102 |
| 00:16 | mister_engage_delay_s | initial 51 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.14 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 8 |
| 00:16 | vent_prefer_temp_delta_f | initial 15 |
| 00:16 | vpd_watch_dwell_s | initial 75 |
| 06:30 | dwell_gate_ms | 300000 → 285000 |
| 06:30 | min_fog_off_s | 96 → 84 |
| 06:30 | min_fog_on_s | 50.25 → 54.75 |
| 06:30 | mister_all_delay_s | 102 → 97.5 |
| 06:30 | mister_engage_delay_s | 51 → 48.75 |
| 06:30 | temp_hysteresis | 2.14 → 2.05 |
| 06:30 | vpd_watch_dwell_s | 75 → 71.25 |
| 10:00 | dwell_gate_ms | 285000 → 270000 |
| 10:00 | min_fog_off_s | 84 → 72 |
| 10:00 | min_fog_on_s | 54.75 → 59.25 |
| 10:00 | mister_all_delay_s | 97.5 → 93 |
| 10:00 | mister_engage_delay_s | 48.75 → 46.5 |
| 10:00 | temp_hysteresis | 2.05 → 1.96 |
| 10:00 | vent_prefer_temp_delta_f | 15 → 12 |
| 10:00 | vpd_watch_dwell_s | 71.25 → 67.5 |
🌅 Morning Cycle (6:42 AM) — iris-20261106-0639
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261105-1654
Result: Scoped 0.094-day window: contract-2 planner_score 76.2; binary both-axis/temp/VPD compliance 53.5%/97.6%/53.8%; nominal cold 0.05h, VPD-low 1.04h, VPD-high/heat/dew-risk 0. The brief frost-protection objective was met on temperature with no dew risk, but VPD-low persisted; this short window ended before the forecast dry ramp. Resource cost, coverage, consumed-target attribution, and physical crop outcomes unavailable; no causal claim or durable lesson. Score: 5/10
Hypothesis
Testing: Test moderate band-edge-only wet assist on a cold, overcast day; compare VPD-high/low hours and dew safety without changing crop bands. Expected outcome: During this plan window, keep dew-risk at 0h, VPD-low stress below 2h and VPD-high below 2h while maintaining at least 90% binary temperature compliance; evidence remains coverage-limited.
Conditions
59.0°F
30.0%
216.0 W/m²
100.0%
Nov 6: 33F frost dawn, 59F high, overcast low-solar daylight; indoor 66.1F/VPD 0.90 with 14.8F dew margin. Prior completed plan self-grade 6 vs anchor 1 (gap 5): its narrow cold objective was largely met (94.9% temp compliance, 0.10h cold stress), but VPD compliance was 39.2%, VPD-low 1.24h, and 110/154 guardrail events were held. I graded the cold objective more heavily; the anchor penalized weak VPD outcome and poor attribution. No efficacy claim.
Expected stress windows
Preserve heat; avoid unnecessary cold-air exchange and wetting while frost passes.
Allow band-edge mist assist; reserve fog for persistent excess with safe dew margin.
Parameter rationale
Tie first wet assist to about 0.05 kPa above the high edge, preserving a dry-band interval while allowing response to a real daytime rise.
Reserve heavy fog for persistent excess while threshold-limited misting remains available during the forecast VPD rise.
Setpoints
Friday November 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:39 | hyst 0.186 | Dawn: protect warmth through the 33F frost; no unnecessary w |
| 09:00 | hyst 0.186 | Morning ramp: keep wet assist band-coupled as outdoor VPD ri |
| 14:00 | hyst 0.186 | Peak VPD window: favor corridor recovery over resource savin |
| 16:30 | hyst 0.186 | Decline: taper wet duty only as observed VPD recovers; keep |
| 19:00 | hyst 0.186 | Evening: protect the cold night and avoid repeat VPD-low exp |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:39 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Dawn: protect warmth through the 33F frost; no unnecessary w |
| 09:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Morning ramp: keep wet assist band-coupled as outdoor VPD ri |
| 14:00 | s2 1.8900000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Peak VPD window: favor corridor recovery over resource savin |
| 16:30 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Decline: taper wet duty only as observed VPD recovers; keep |
| 19:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Evening: protect the cold night and avoid repeat VPD-low exp |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:39 | band_track_fraction | initial 0 |
| 06:39 | cold_vent_guard_delta_f | initial 10 |
| 06:39 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:39 | direct_wet_stress_min_dew_margin_f | initial 9 |
| 06:39 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:39 | dwell_gate_ms | initial 210000 |
| 06:39 | enthalpy_close | initial 1 |
| 06:39 | enthalpy_open | initial -2 |
| 06:39 | fog_escalation_kpa | initial 0.25 |
| 06:39 | heat_hysteresis | initial 1 |
| 06:39 | min_fog_off_s | initial 72 |
| 06:39 | min_fog_on_s | initial 59.25 |
| 06:39 | mist_backoff_s | initial 600 |
| 06:39 | mist_max_closed_vent_s | initial 600 |
| 06:39 | mist_thermal_relief_s | initial 90 |
| 06:39 | mister_all_delay_s | initial 75 |
| 06:39 | mister_engage_delay_s | initial 37.5 |
| 06:39 | mister_water_budget_gal | initial 120 |
| 06:39 | night_vpd_bias_kpa | initial 0 |
| 06:39 | outdoor_staleness_max_s | initial 600 |
| 06:39 | sw_dwell_gate_enabled | initial 1 |
| 06:39 | sw_fog_closes_vent | initial 1 |
| 06:39 | sw_mister_closes_vent | initial 0 |
| 06:39 | sw_summer_vent_enabled | initial 1 |
| 06:39 | temp_hysteresis | initial 1.6 |
| 06:39 | vent_exchange_fraction | initial 0.3 |
| 06:39 | vent_prefer_dp_delta_f | initial 4 |
| 06:39 | vent_prefer_temp_delta_f | initial 6 |
| 06:39 | vpd_watch_dwell_s | initial 52.5 |
| 14:00 | cold_vent_guard_delta_f | 10 → 8 |
| 14:00 | min_fog_off_s | 72 → 66 |
| 14:00 | min_fog_on_s | 59.25 → 61.5 |
| 14:00 | vent_prefer_temp_delta_f | 6 → 4 |
| 16:30 | cold_vent_guard_delta_f | 8 → 10 |
| 16:30 | min_fog_off_s | 66 → 72 |
| 16:30 | min_fog_on_s | 61.5 → 59.25 |
| 16:30 | vent_prefer_temp_delta_f | 4 → 6 |
🌅 Morning Cycle (8:58 AM) — iris-20261106-0854
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261106-0016
Previous hypothesis: Overnight frost protection with limited, band-coupled moisture readiness, then a modest early-day response to the forecast VPD rise. Prior completed plan iris-20261105-0705 scored 76.5 in its 0.409-day window but still had 7.05 h nominal cold stress and 2.47 h VPD-high; self-grade 3 vs anchor 1 (2-point gap). Its 259/324 VPD-high guardrail events were held, so efficacy attribution is weak and no durable lesson is justified. Now 60.9°F, VPD 0.57 kPa, dew margin 10.2°F, heat1 on; current climate authority puts VPD below its high edge, while open alert 13993 cites a different [0.73,1.16] band. Preserve warmth, keep wet support reachable only around the live band edge, and reassess during the cloudy rise to 59°F / outdoor VPD ~1.19. No crop outcome or confirmed consumed-target evidence. Result: Plan-window evaluation (use window scorecard row): 0.640-day span, planner score 73.9, contract-2 binary both-axis/temp/VPD compliance 51.5%/96.3%/52.3%, nominal stress 0 heat, 0.29h cold, 4.70h VPD-low, 0 VPD-high. This partially met cold protection but missed the VPD objective; the full Nov 6 day was 97.6% temp / 53.8% VPD with 11.08 nominal VPD-low hours and 0.2 dp-risk hours. A separate prose row in the assembled context conflicts (score 69.9, 28.1% both, 3.73h VPD-low), so attribution is uncertain. Resource costs, coverage, consumed-target confirmation, and physical crop evidence are unavailable. Realized solar-night dryout had 12 episodes: 10 ineffective, 2 insufficient-evidence, none effective; several failed temperature-floor gates, so safety pass is not effectiveness. Score: 4/10
Hypothesis
Testing: Continue the existing moderate band-edge wet-assist test through today’s overcast window; preserve its treatment and crop bands, and assess VPD-high/low plus dew evidence. Expected outcome: Avoid forecast-only wetting while measured house VPD is in-band; target zero dew-risk and bounded overnight VPD-low exposure, then permit 20–35% capped band-edge assist on dry ramps only when live VPD exceeds the high edge.
Setpoints
Friday November 06
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:54 | hyst 0.16525 | Keep today's moderate live-edge test; outdoor forecast has c |
| 17:00 | hyst 0.16525 | Cold clear frost night; suppress routine wetting, preserve h |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:54 | s2 1.7425000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 45; wt 1.5666666666666667 | Keep today's moderate live-edge test; outdoor forecast has c |
| 17:00 | s2 1.84; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.05; all 1.25; pulse 30; gap 56.25; wt 1.3666666666666667 | Cold clear frost night; suppress routine wetting, preserve h |
Saturday November 07
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.16525 | After frost, restore low-duty edge readiness; do not wet fro |
| 11:00 | hyst 0.16525 | Sunny dry ramp: bounded assist if measured VPD crosses its h |
| 17:00 | hyst 0.16525 | Taper after the dry ramp; limit overnight VPD-low and dew ri |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.7425000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 45; wt 1.5333333333333332 | After frost, restore low-duty edge readiness; do not wet fro |
| 11:00 | s2 1.7125000000000001; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 37.5; gap 37.5; wt 1.6666666666666665 | Sunny dry ramp: bounded assist if measured VPD crosses its h |
| 17:00 | s2 1.84; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.05; all 1.25; pulse 30; gap 56.25; wt 1.3666666666666667 | Taper after the dry ramp; limit overnight VPD-low and dew ri |
Sunday November 08
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.16525 | Stage gently before the very dry Sunday forecast; require li |
| 11:00 | hyst 0.16525 | Use calibrated but still dry prior; open bounded wet assist |
| 17:00 | hyst 0.16525 | Taper after Sunday dry peak while retaining modest live-edge |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.7425000000000002; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 45; wt 1.5333333333333332 | Stage gently before the very dry Sunday forecast; require li |
| 11:00 | s2 1.6975; cool_exit 1.78; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 41.25; gap 33.75; wt 1.7333333333333334 | Use calibrated but still dry prior; open bounded wet assist |
| 17:00 | s2 1.81; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1; all 1.2; pulse 30; gap 48.75; wt 1.4666666666666668 | Taper after Sunday dry peak while retaining modest live-edge |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 08:54 | band_track_fraction | initial 0 |
| 08:54 | cold_vent_guard_delta_f | initial 10 |
| 08:54 | cool_stage2_exit_hysteresis_f | initial 1 |
| 08:54 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 08:54 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 08:54 | dwell_gate_ms | initial 240000 |
| 08:54 | enthalpy_close | initial 1 |
| 08:54 | enthalpy_open | initial -2 |
| 08:54 | fog_escalation_kpa | initial 0.35 |
| 08:54 | heat_hysteresis | initial 1 |
| 08:54 | min_fog_off_s | initial 78 |
| 08:54 | min_fog_on_s | initial 57 |
| 08:54 | mist_backoff_s | initial 600 |
| 08:54 | mist_max_closed_vent_s | initial 600 |
| 08:54 | mist_thermal_relief_s | initial 90 |
| 08:54 | mister_all_delay_s | initial 84 |
| 08:54 | mister_engage_delay_s | initial 42 |
| 08:54 | mister_water_budget_gal | initial 120 |
| 08:54 | night_vpd_bias_kpa | initial 0 |
| 08:54 | outdoor_staleness_max_s | initial 600 |
| 08:54 | sw_dwell_gate_enabled | initial 1 |
| 08:54 | sw_fog_closes_vent | initial 1 |
| 08:54 | sw_mister_closes_vent | initial 0 |
| 08:54 | sw_summer_vent_enabled | initial 1 |
| 08:54 | temp_hysteresis | initial 1.78 |
| 08:54 | vent_exchange_fraction | initial 0.3 |
| 08:54 | vent_prefer_dp_delta_f | initial 3 |
| 08:54 | vent_prefer_temp_delta_f | initial 6 |
| 08:54 | vpd_watch_dwell_s | initial 60 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.15 |
| 17:00 | fog_escalation_kpa | 0.35 → 0.5 |
| 17:00 | min_fog_off_s | 78 → 96 |
| 17:00 | min_fog_on_s | 57 → 50.25 |
| 17:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 08:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 08:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.05 |
| 08:00 | fog_escalation_kpa | 0.5 → 0.3 |
| 08:00 | min_fog_off_s | 96 → 78 |
| 08:00 | min_fog_on_s | 50.25 → 57 |
| 08:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 11:00 | cold_vent_guard_delta_f | 10 → 9 |
| 11:00 | fog_escalation_kpa | 0.3 → 0.25 |
| 11:00 | min_fog_off_s | 78 → 66 |
| 11:00 | min_fog_on_s | 57 → 61.5 |
| 11:00 | vent_prefer_temp_delta_f | 6 → 5 |
| 17:00 | cold_vent_guard_delta_f | 9 → 10 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.15 |
| 17:00 | fog_escalation_kpa | 0.25 → 0.5 |
| 17:00 | min_fog_off_s | 66 → 96 |
| 17:00 | min_fog_on_s | 61.5 → 50.25 |
| 17:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 17:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 08:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 08:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.05 |
| 08:00 | fog_escalation_kpa | 0.5 → 0.3 |
| 08:00 | min_fog_off_s | 96 → 78 |
| 08:00 | min_fog_on_s | 50.25 → 57 |
| 08:00 | vent_prefer_dp_delta_f | 4 → 3 |
| 11:00 | cold_vent_guard_delta_f | 10 → 9 |
| 11:00 | fog_escalation_kpa | 0.3 → 0.25 |
| 11:00 | min_fog_off_s | 78 → 60 |
| 11:00 | min_fog_on_s | 57 → 63.75 |
| 11:00 | vent_prefer_temp_delta_f | 6 → 5 |
| 17:00 | cold_vent_guard_delta_f | 9 → 10 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 8 → 9 |
| 17:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 17:00 | fog_escalation_kpa | 0.25 → 0.35 |
| 17:00 | min_fog_off_s | 60 → 84 |
| 17:00 | min_fog_on_s | 63.75 → 54.75 |
| 17:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 17:00 | vent_prefer_temp_delta_f | 5 → 6 |
End-of-Day Summary
Climate
59.2–82.5°F; avg 68.4°F
0.27–1.34 kPa; avg 0.82 kPa
49.2–88.4%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
legacy_invalid_exterior_proxy_plus_fixture_estimate - Validity:
dli-validity-v1; 2024-01-01T00:00:00+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 0.0h
- Cold stress (<55°F): 0.6h
Economics
Not available
USD 5.45
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 12 min | Primary exhaust runtime. |
| Fan 2 | 10 min | Secondary exhaust runtime. |
| Vent | 20 min | Intake vent runtime. |
| Fog | 3 min | Fogger runtime. |
| Heat 1 electric | 1208 min | Electric heater runtime. |
| Heat 2 gas | 525 min | Gas heater runtime. |
| Grow lights | 1142 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Vanda Orchids | center | 70% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Hanging baskets visible in the center zone. Roots appear exposed and healthy. No visible wilting or leaf discoloration, though low light (0 lux) is expected at this time (21:00). || Hanging baskets visible in the upper center. Roots appear dense and white (healthy) in the infrared spectrum. Leaves appear turgid, though low light (0 lux) makes detailed leaf color assessment difficult. || [exposed roots] Hanging baskets visible in the center zone. Roots appear dry and exposed, which is typical for Vanda but requires monitoring given the 0 lux light reading. || [root exposure, potential moisture stress] Hanging Vanda orchids visible in the center zone. Roots are exposed and appear somewhat dry, consistent with the low soil moisture reading (19.6%) and high VPD (1.20 kPa). Foliage appears green but may be under stress due to environmental conditions.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 72.8°F | 1.06 kPa | 61.8% |
| 11:00 | 74.2°F | 1.23 kPa | 56.9% |
| 12:00 | 73.9°F | 1.27 kPa | 54.8% |
| 13:00 | 76.8°F | 1.19 kPa | 62.2% |
| 14:00 | 79.7°F | 1.17 kPa | 66.0% |
| 15:00 | 80.6°F | 1.07 kPa | 70.4% |
| 16:00 | 74.3°F | 0.86 kPa | 70.5% |
| 17:00 | 72.7°F | 0.87 kPa | 68.5% |
| 18:00 | 70.7°F | 0.84 kPa | 67.3% |
| 19:00 | 68.9°F | 0.81 kPa | 66.6% |
| 20:00 | 67.1°F | 0.77 kPa | 66.3% |
| 21:00 | 64.9°F | 0.69 kPa | 67.4% |
| 22:00 | 64.3°F | 0.69 kPa | 66.8% |
| 23:00 | 62.0°F | 0.59 kPa | 69.0% |
| 00:00 | 60.6°F | 0.56 kPa | 69.3% |
| 01:00 | 60.2°F | 0.56 kPa | 68.9% |
| 02:00 | 60.8°F | 0.60 kPa | 67.3% |
| 03:00 | 60.7°F | 0.69 kPa | 62.1% |
| 04:00 | 61.4°F | 0.78 kPa | 58.3% |
| 05:00 | 62.7°F | 0.78 kPa | 59.9% |
| 06:00 | 64.5°F | 0.74 kPa | 63.7% |
| 07:00 | 66.0°F | 0.47 kPa | 78.9% |
| 08:00 | 67.9°F | 0.65 kPa | 72.4% |
| 09:00 | 71.3°F | 0.84 kPa | 67.7% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-10-31 | 0.0h | 0.0h | 0.2h |
| 2026-11-01 | 0.0h | 0.0h | 0.5h |
| 2026-11-02 | 0.0h | 0.0h | 0.5h |
| 2026-11-03 | 0.0h | 0.1h | 0.3h |
| 2026-11-04 | 0.0h | 0.4h | 0.8h |
| 2026-11-05 | 0.0h | 0.7h | 1.4h |
| 2026-11-06 | 0.0h | 0.0h | 0.6h |