November 10, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
10
7
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:16 | MIDNIGHT | plan_written | Wrote public plan iris-20261110-0016. Resolved 00:18 MDT. |
| Morning planning cycle | 06:41 | SUNRISE | plan_written | Wrote public plan iris-20261110-0642. Resolved 06:45 MDT. |
| Solar peak planning checkpoint | 11:45 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 11:47 MDT. |
| Forecast deviation | 13:06 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261110-1307. Resolved 13:11 MDT. |
| Peak Stress | 13:45 | TRANSITION | acked | Acknowledged: Peak-stress check: fresh indoor readings are 77.8°F/1.26 kPa with 14.4°F dew margin; zone VPD spread is small, and today's scorecard shows no heat or VPD-high stress to date. Current plan already keeps live-edge mist/fog assist available, while current VPD is below the daytime high-band edge (1.29 kPa) and equipment is idle aside from heat1. Forecast/current outdoor conditions differ, but no measured worsening justifies another tunable change; retain the plan and avoid forecast-only wetting. Resolved 13:46 MDT. |
| Forecast deviation | 14:06 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261110-1406. Resolved 14:10 MDT. |
| Forecast deviation | 15:35 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261110-1535. Resolved 15:39 MDT. |
| Decline | 15:48 | TRANSITION | acked | Acknowledged: No safe tunable change: indoor VPD remains above the 0.90 high edge (1.11 kPa) with healthy 13.5°F dew margin; current wet/fog thresholds are already band-coupled and the active plan only tapers modestly at 17:00. Avoid further evening aggressiveness changes pending observed recovery. Resolved 15:49 MDT. |
| Evening planning cycle | 16:48 | SUNSET | plan_written | Wrote public plan iris-20261110-1648. Resolved 16:52 MDT. |
| Forecast deviation | 16:52 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261110-1652. Resolved 16:55 MDT. |
🌅 Morning Cycle (12:18 AM) — iris-20261110-0016
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261109-1652
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:68.0,“outdoor_rh_min_pct”:17.0,“solar_peak_w_m2”:417,“cloud_cover_avg_pct”:75.0,“notes”:“House 75.0F/0.72 kPa, dew margin 8.3F; today’s minimum 3.6F. Tonight falls to 36F before dawn with outdoor VPD 0.25-0.31; Tuesday reaches 68F/17% RH and VPD 1.91 with variable cloud. Today score 73 vs 7d 76.5; VPD-low dominates. I graded plans 0640 and 0850 at 3 vs anchors 6: self-grade penalized 2h windows ending before their principal stress periods; anchor favored safe partial windows/no guardrail events. Neither hypothesis was fully tested; no causal credit.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-10T00:00:00-07:00”,“end”:“2026-11-10T07:00:00-07:00”,“severity”:“high”,“mitigation”:“Retain heat, avoid unnecessary cold exchange, and damp ordinary mode churn while preserving safety preemption… Result: Window-scoped evaluation only (0.268 d): contract-2 historical score 74.9; binary temp/VPD compliance 96.8%/55.4%; nominal stress cold 0.11 h, VPD-low 1.56 h, VPD-high/heat/dew-risk 0. No resource costs, fixed-panel or physical crop outcome, consumed-target proof, or verified coverage. The overnight heat/dew-safe low-wet posture had near-zero cold and no recorded dew risk but VPD-low remained the main miss. Morning dry-ramp handoff was outside this plan window; no causal efficacy can be assigned. Score 5/10: partial/safe but weak VPD corridor result and incomplete test. Score: 5/10
Hypothesis
Testing: Frost-night moisture taper with a live-VPD-gated sunrise handoff; judge the midday response from measured indoor conditions, not outdoor VPD alone. Expected outcome: Keep pre-dawn dew-risk at or below 0.1h and avoid wetting below the live VPD high edge; reopen bounded assist at 10:00 only on measured excess. Costs and crop effects remain unverified.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.2515 | Cold night; VPD 0.60 below 0.90 high edge. Retain heat/dew s |
| 04:30 | hyst 0.2515 | Pre-dawn frost minimum near 36°F; maintain live-demand-only |
| 07:00 | hyst 0.2465 | Sunrise ramp is still cold/cloudy; permit modest assist only |
| 10:00 | hyst 0.2415 | Handoff to the dry VPD ramp; open bounded band-coupled mist/ |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.995; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.2666666666666666 | Cold night; VPD 0.60 below 0.90 high edge. Retain heat/dew s |
| 04:30 | s2 1.995; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.2666666666666666 | Pre-dawn frost minimum near 36°F; maintain live-demand-only |
| 07:00 | s2 1.8475000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 1; all 1.2; pulse 30; gap 48.75; wt 1.4333333333333333 | Sunrise ramp is still cold/cloudy; permit modest assist only |
| 10:00 | s2 1.7875; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.6666666666666665 | Handoff to the dry VPD ramp; open bounded band-coupled mist/ |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 12 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 00:15 | dwell_gate_ms | initial 285000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.4 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 108 |
| 00:15 | min_fog_on_s | initial 45.75 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 97.5 |
| 00:15 | mister_engage_delay_s | initial 48.75 |
| 00:15 | mister_water_budget_gal | initial 120 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.05 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 6 |
| 00:15 | vent_prefer_temp_delta_f | initial 8 |
| 00:15 | vpd_watch_dwell_s | initial 71.25 |
| 07:00 | cold_vent_guard_delta_f | 12 → 11 |
| 07:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 07:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.1 |
| 07:00 | dwell_gate_ms | 285000 → 270000 |
| 07:00 | fog_escalation_kpa | 0.4 → 0.3 |
| 07:00 | min_fog_off_s | 108 → 84 |
| 07:00 | min_fog_on_s | 45.75 → 54.75 |
| 07:00 | mister_all_delay_s | 97.5 → 93 |
| 07:00 | mister_engage_delay_s | 48.75 → 46.5 |
| 07:00 | temp_hysteresis | 2.05 → 1.96 |
| 07:00 | vent_prefer_dp_delta_f | 6 → 5 |
| 07:00 | vent_prefer_temp_delta_f | 8 → 7 |
| 07:00 | vpd_watch_dwell_s | 71.25 → 67.5 |
| 10:00 | cold_vent_guard_delta_f | 11 → 10 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 10:00 | dwell_gate_ms | 270000 → 255000 |
| 10:00 | fog_escalation_kpa | 0.3 → 0.25 |
| 10:00 | min_fog_off_s | 84 → 60 |
| 10:00 | min_fog_on_s | 54.75 → 63.75 |
| 10:00 | mister_all_delay_s | 93 → 88.5 |
| 10:00 | mister_engage_delay_s | 46.5 → 44.25 |
| 10:00 | temp_hysteresis | 1.96 → 1.87 |
| 10:00 | vent_prefer_temp_delta_f | 7 → 6 |
| 10:00 | vpd_watch_dwell_s | 67.5 → 63.75 |
🌅 Morning Cycle (6:45 AM) — iris-20261110-0642
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261109-1652
Result: Scoped completed window for iris-20261110-0642 (0.268 d, ~6.4 h): contract-2 historical controller-credit score 74.1; binary temp/VPD shares 97.0%/58.6%; nominal cold stress 0.11 h, VPD-low 1.56 h, and zero heat/VPD-high/dew-risk. The cold/VPD-low windows predicted for 19:00-23:00 were after the plan was replaced around 13:06, so they were untested. Daytime intent aligned with avoiding forecast-only wetting, but VPD corridor performance remained weak. Anchor comparison is 4/10 self-grade versus 2; 72 VPD-high guardrail events had 68 held and 4 dispatched, weakening attribution. Costs, qualified coverage, consumed-target proof, and physical crop outcomes are unavailable; no causal or resource claim. Score: 4/10
Hypothesis
Testing: Test a live-VPD-gated, modest midday wet-assist ramp on a cold overcast day, then taper before the low-VPD night. Expected outcome: Avoid forecast-only wetting; retain assist near the live high edge if indoor VPD rises, keep dew margin at or above 10F, and limit evening VPD-low carryover. Do not infer crop or resource benefit.
Conditions
68.0°F
16.0%
252.0 W/m²
60.0%
Forecast is overcast through the 68F/16% RH dry ramp; indoor is 62.6F/0.79kPa with 14.5F dew margin and 0.90kPa high edge. Prior plan 1652 self-score 4 vs anchor 1 (+3): 204 VPD-high guardrail events (158 held) weaken causal credit despite a safe 7.4h window.
Expected stress windows
Taper by 20:00; keep dew floor 10F and avoid forecast-only wetting.
Keep heat-first posture; avoid unnecessary cold exchange and preserve relay dwell.
Parameter rationale
Keep first-stage wet assist gated near live high-band excess, not outdoor VPD alone.
Permit bounded fog only on stronger measured VPD excess while retaining the 10F dew floor.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:40 | hyst 0.21150000000000002 | Dawn handoff: heat-first; avoid forecast-only wetting and ke |
| 09:30 | hyst 0.21150000000000002 | Morning ramp: modest assist only as measured indoor VPD appr |
| 13:30 | hyst 0.21150000000000002 | Peak dry-air window: allow bounded wet assist on live excess |
| 16:15 | hyst 0.21150000000000002 | Decline: keep edge assist available until observed VPD recov |
| 19:00 | hyst 0.21650000000000003 | Evening descent: low wet duty through 20:00, heat-first and |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:40 | s2 1.995; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1.05; all 1.25; pulse 30; gap 60; wt 1.2666666666666666 | Dawn handoff: heat-first; avoid forecast-only wetting and ke |
| 09:30 | s2 1.965; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1; all 1.2; pulse 30; gap 56.25; wt 1.3666666666666667 | Morning ramp: modest assist only as measured indoor VPD appr |
| 13:30 | s2 1.92; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 45; wt 1.5333333333333332 | Peak dry-air window: allow bounded wet assist on live excess |
| 16:15 | s2 1.95; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 52.5; wt 1.4133333333333333 | Decline: keep edge assist available until observed VPD recov |
| 19:00 | s2 2.0100000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 60; wt 1.2333333333333334 | Evening descent: low wet duty through 20:00, heat-first and |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:40 | band_track_fraction | initial 0 |
| 06:40 | cold_vent_guard_delta_f | initial 12 |
| 06:40 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:40 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 06:40 | direct_wet_stress_vpd_margin_kpa | initial 0.15 |
| 06:40 | dwell_gate_ms | initial 285000 |
| 06:40 | enthalpy_close | initial 1 |
| 06:40 | enthalpy_open | initial -2 |
| 06:40 | fog_escalation_kpa | initial 0.35 |
| 06:40 | heat_hysteresis | initial 1 |
| 06:40 | min_fog_off_s | initial 108 |
| 06:40 | min_fog_on_s | initial 45.75 |
| 06:40 | mist_backoff_s | initial 600 |
| 06:40 | mist_max_closed_vent_s | initial 600 |
| 06:40 | mist_thermal_relief_s | initial 90 |
| 06:40 | mister_all_delay_s | initial 97.5 |
| 06:40 | mister_engage_delay_s | initial 48.75 |
| 06:40 | mister_water_budget_gal | initial 120 |
| 06:40 | night_vpd_bias_kpa | initial 0 |
| 06:40 | outdoor_staleness_max_s | initial 600 |
| 06:40 | sw_dwell_gate_enabled | initial 1 |
| 06:40 | sw_fog_closes_vent | initial 1 |
| 06:40 | sw_mister_closes_vent | initial 0 |
| 06:40 | sw_summer_vent_enabled | initial 1 |
| 06:40 | temp_hysteresis | initial 2.05 |
| 06:40 | vent_exchange_fraction | initial 0.3 |
| 06:40 | vent_prefer_dp_delta_f | initial 6 |
| 06:40 | vent_prefer_temp_delta_f | initial 8 |
| 06:40 | vpd_watch_dwell_s | initial 71.25 |
| 09:30 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.1 |
| 09:30 | min_fog_off_s | 108 → 96 |
| 09:30 | min_fog_on_s | 45.75 → 50.25 |
| 13:30 | direct_wet_stress_vpd_margin_kpa | 0.1 → 0.05 |
| 13:30 | fog_escalation_kpa | 0.35 → 0.25 |
| 13:30 | min_fog_off_s | 96 → 78 |
| 13:30 | min_fog_on_s | 50.25 → 57 |
| 16:15 | fog_escalation_kpa | 0.25 → 0.3 |
| 16:15 | min_fog_off_s | 78 → 90 |
| 16:15 | min_fog_on_s | 57 → 52.5 |
| 19:00 | dwell_gate_ms | 285000 → 300000 |
| 19:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 19:00 | min_fog_off_s | 90 → 114 |
| 19:00 | min_fog_on_s | 52.5 → 43.5 |
| 19:00 | mister_all_delay_s | 97.5 → 102 |
| 19:00 | mister_engage_delay_s | 48.75 → 51 |
| 19:00 | temp_hysteresis | 2.05 → 2.14 |
| 19:00 | vpd_watch_dwell_s | 71.25 → 75 |
☀️ Midday Cycle (1:11 PM) — iris-20261110-1307
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261110-0016
Previous hypothesis: Nov 9 contract-2 score was 76.7 (97.9% temp, 60.4% VPD); VPD-low dominated at 9.42 nominal hours, dew margin reached 3.6°F with 0.2h dp-risk. Completed plan windows were weak/short: 1034 scored 4 matching anchor 4, with 2.44h VPD-low; 1649 lasted ~1.4 min and scored 3, anchor unavailable. Today begins 61.2°F/0.60 kPa with 10.9°F dew margin and heat1 on; frost lows 36°F pre-dawn and 34°F tomorrow morning. Keep wetting gated below the live high edge overnight, preserve heat/dew safety, then reopen modest band-coupled assist as the measured morning VPD rises; forecast dry ramp peaks near 1.94 kPa outdoors but remains cloudy and is not indoor exposure. No causal crop or resource benefit is assumed. Result: Completed plan iris-20261110-1307 governed a short ~0.041-day (about 1-hour) window before replacement. Its outdoor-nowcast diagnosis was directionally supported: at the new 15:35 deviation, outdoor VPD was 1.48 vs forecast 2.13 kPa, while historical lead-matched forecast-minus-observed bias remained small (+0.004 kPa at 0–6h, +0.035 at 6–24h). The greenhouse remains distinct from that outdoor signal: fresh house VPD is 1.04 kPa, 0.14 above the current 0.90 high edge, temp 74.6°F, dew margin 12.8°F. Window scorecard shows planner score 74, binary temp/VPD 97.3%/62.6%, nominal cold 0.02h and VPD-low 0.24h, with no VPD-high or heat stress. Equipment is normal with heat1 on and vent/fans/fog/misters off. This is limited evidence that forecast-only misting was avoided without an immediate recorded stress event, not a meaningful test of the longer frost/dry-ramp hypotheses. No resource or physical crop outcome is available; attribution is weak and no durable lesson is extracted. Score: 4/10
Hypothesis
Testing: Operational forecast-deviation response; distinguish outdoor nowcast error from live greenhouse demand. Expected outcome: No forecast-only wetting; retain band-edge assist with dew margin >=10°F, suppress overnight duty through frost, and reopen only on measured VPD rise. No crop or resource benefit assumed.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 13:06 | hyst 0.1375 | Live VPD is elevated with healthy dew margin; keep bounded e |
| 17:00 | hyst 0.1375 | Cooling outdoor air and falling VPD: end wetting at cutoff; |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 13:06 | s2 1.5725000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Live VPD is elevated with healthy dew margin; keep bounded e |
| 17:00 | s2 1.6525; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cooling outdoor air and falling VPD: end wetting at cutoff; |
Wednesday November 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.1375 | Frost minimum near 34°F and forecast VPD below band; zero we |
| 11:00 | hyst 0.1375 | Reopen modest assist only on live high-edge demand during th |
| 17:00 | hyst 0.1375 | Taper at the cool evening handoff; no overnight wetting on a |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.745; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Frost minimum near 34°F and forecast VPD below band; zero we |
| 11:00 | s2 1.5925; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7 | Reopen modest assist only on live high-edge demand during th |
| 17:00 | s2 1.6; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Taper at the cool evening handoff; no overnight wetting on a |
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Prepare for dry daylight VPD rise; assist remains conditiona |
| 17:00 | hyst 0.1375 | Return to low-wet posture for the cool evening and cloudy ov |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.465; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7 | Prepare for dry daylight VPD rise; assist remains conditiona |
| 17:00 | s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Return to low-wet posture for the cool evening and cloudy ov |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Use modest live-edge assist only if measured VPD rises throu |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.7750000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Use modest live-edge assist only if measured VPD rises throu |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 13:06 | band_track_fraction | initial 0 |
| 13:06 | cold_vent_guard_delta_f | initial 12 |
| 13:06 | cool_stage2_exit_hysteresis_f | initial 1 |
| 13:06 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 13:06 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 13:06 | dwell_gate_ms | initial 210000 |
| 13:06 | enthalpy_close | initial 1 |
| 13:06 | enthalpy_open | initial -2 |
| 13:06 | fog_escalation_kpa | initial 0.2 |
| 13:06 | heat_hysteresis | initial 1 |
| 13:06 | min_fog_off_s | initial 54 |
| 13:06 | min_fog_on_s | initial 66 |
| 13:06 | mist_backoff_s | initial 600 |
| 13:06 | mist_max_closed_vent_s | initial 600 |
| 13:06 | mist_thermal_relief_s | initial 90 |
| 13:06 | mister_all_delay_s | initial 75 |
| 13:06 | mister_engage_delay_s | initial 37.5 |
| 13:06 | mister_water_budget_gal | initial 120 |
| 13:06 | night_vpd_bias_kpa | initial 0 |
| 13:06 | outdoor_staleness_max_s | initial 600 |
| 13:06 | sw_dwell_gate_enabled | initial 1 |
| 13:06 | sw_fog_closes_vent | initial 1 |
| 13:06 | sw_mister_closes_vent | initial 0 |
| 13:06 | sw_summer_vent_enabled | initial 1 |
| 13:06 | temp_hysteresis | initial 1.6 |
| 13:06 | vent_exchange_fraction | initial 0.3 |
| 13:06 | vent_prefer_dp_delta_f | initial 6 |
| 13:06 | vent_prefer_temp_delta_f | initial 8 |
| 13:06 | vpd_watch_dwell_s | initial 52.5 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 10 → 11 |
| 17:00 | min_fog_off_s | 54 → 72 |
| 17:00 | min_fog_on_s | 66 → 59.25 |
| 07:00 | direct_wet_stress_min_dew_margin_f | 11 → 12 |
| 11:00 | direct_wet_stress_min_dew_margin_f | 12 → 10 |
| 11:00 | min_fog_off_s | 72 → 60 |
| 11:00 | min_fog_on_s | 59.25 → 63.75 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 10 → 12 |
| 17:00 | min_fog_off_s | 60 → 72 |
| 17:00 | min_fog_on_s | 63.75 → 59.25 |
| 09:00 | direct_wet_stress_min_dew_margin_f | 12 → 10 |
| 09:00 | min_fog_off_s | 72 → 60 |
| 09:00 | min_fog_on_s | 59.25 → 63.75 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 10 → 12 |
| 17:00 | min_fog_off_s | 60 → 72 |
| 17:00 | min_fog_on_s | 63.75 → 59.25 |
| 09:00 | direct_wet_stress_min_dew_margin_f | 12 → 10 |
| 09:00 | min_fog_off_s | 72 → 66 |
| 09:00 | min_fog_on_s | 59.25 → 61.5 |
☀️ Midday Cycle (2:10 PM) — iris-20261110-1406
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261110-0642
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:68.0,“outdoor_rh_min_pct”:16.0,“solar_peak_w_m2”:252,“cloud_cover_avg_pct”:60,“notes”:“Forecast is overcast through the 68F/16% RH dry ramp; indoor is 62.6F/0.79kPa with 14.5F dew margin and 0.90kPa high edge. Prior plan 1652 self-score 4 vs anchor 1 (+3): 204 VPD-high guardrail events (158 held) weaken causal credit despite a safe 7.4h window.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-10T19:00:00-07:00”,“end”:“2026-11-10T23:00:00-07:00”,“severity”:“medium”,“mitigation”:“Taper by 20:00; keep dew floor 10F and avoid forecast-only wetting.”},{“kind”:“cold”,“start”:“2026-11-10T19:00:00-07:00”,“end”:“2026-11-10T23:00:00-07:00”,“severity”:“medium”,“mitigation”:“Keep heat-first posture; avoid unnecessary cold exchange and preserve relay dwell.”}],“rationale”:[{“parameter”:“mister_engage_kpa”,“old_value”:1.1,“new_value”:0… Result: Plan-specific window 14:10-15:39 MDT (~1.49h), not full-day attribution. The supplied window row reports planner score 76.9, compliance 62.0%, temp 96.9%, VPD 63.8%, nominal cold 0.05h, VPD-low 0.53h, and no heat/VPD-high/dew-risk. Its forecast-deviation rationale (outdoor VPD forecast high by ~0.69 kPa, not a persistent bias) was directionally sound, but the short window cannot test the overnight recovery plan; evidence of consumed setpoints, cost, and physical crop outcome is unavailable. No durable lesson. Score: 4/10
Hypothesis
Testing: Operational forecast-deviation response; distinguish outdoor nowcast error from live greenhouse demand. Expected outcome: Avoid forecast-only wetting; maintain safe measured-edge assistance, suppress unnecessary night wetting through frost, and reopen on observed VPD rise. No crop or resource benefit assumed.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 14:00 | hyst 0.1375 | Both measured axes exceed their read-only edges; retain meas |
| 18:00 | hyst 0.1375 | Frost approaches; lower wet duty but preserve measured-high |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 14:00 | s2 1.7725000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 37.5; gap 30; wt 1.7666666666666666 | Both measured axes exceed their read-only edges; retain meas |
| 18:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Frost approaches; lower wet duty but preserve measured-high |
Wednesday November 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.1375 | Protect heat and dew safety at the 34°F forecast low; wet on |
| 11:00 | hyst 0.1375 | Restore bounded measured-edge assist for the forecast dry ra |
| 17:00 | hyst 0.1375 | Taper duty only after observed recovery; retain dew and cold |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Protect heat and dew safety at the 34°F forecast low; wet on |
| 11:00 | s2 1.7725000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7333333333333334 | Restore bounded measured-edge assist for the forecast dry ra |
| 17:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Taper duty only after observed recovery; retain dew and cold |
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Thursday dry ramp: allow modest measured-demand assist; the |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.7875; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7000000000000002 | Thursday dry ramp: allow modest measured-demand assist; the |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Friday cloudy dry ramp: keep live-edge assist bounded and le |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Friday cloudy dry ramp: keep live-edge assist bounded and le |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 14:00 | band_track_fraction | initial 0 |
| 14:00 | cold_vent_guard_delta_f | initial 8 |
| 14:00 | cool_stage2_exit_hysteresis_f | initial 1 |
| 14:00 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 14:00 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 14:00 | dwell_gate_ms | initial 210000 |
| 14:00 | enthalpy_close | initial 1 |
| 14:00 | enthalpy_open | initial -2 |
| 14:00 | fog_escalation_kpa | initial 0.2 |
| 14:00 | heat_hysteresis | initial 1 |
| 14:00 | min_fog_off_s | initial 54 |
| 14:00 | min_fog_on_s | initial 66 |
| 14:00 | mist_backoff_s | initial 600 |
| 14:00 | mist_max_closed_vent_s | initial 600 |
| 14:00 | mist_thermal_relief_s | initial 90 |
| 14:00 | mister_all_delay_s | initial 75 |
| 14:00 | mister_engage_delay_s | initial 37.5 |
| 14:00 | mister_water_budget_gal | initial 120 |
| 14:00 | night_vpd_bias_kpa | initial 0 |
| 14:00 | outdoor_staleness_max_s | initial 600 |
| 14:00 | sw_dwell_gate_enabled | initial 1 |
| 14:00 | sw_fog_closes_vent | initial 1 |
| 14:00 | sw_mister_closes_vent | initial 0 |
| 14:00 | sw_summer_vent_enabled | initial 1 |
| 14:00 | temp_hysteresis | initial 1.6 |
| 14:00 | vent_exchange_fraction | initial 0.3 |
| 14:00 | vent_prefer_dp_delta_f | initial 3 |
| 14:00 | vent_prefer_temp_delta_f | initial 4 |
| 14:00 | vpd_watch_dwell_s | initial 52.5 |
| 18:00 | cold_vent_guard_delta_f | 8 → 12 |
| 18:00 | direct_wet_stress_min_dew_margin_f | 10 → 11 |
| 18:00 | min_fog_off_s | 54 → 72 |
| 18:00 | min_fog_on_s | 66 → 59.25 |
| 18:00 | vent_prefer_dp_delta_f | 3 → 6 |
| 18:00 | vent_prefer_temp_delta_f | 4 → 8 |
| 11:00 | cold_vent_guard_delta_f | 12 → 8 |
| 11:00 | direct_wet_stress_min_dew_margin_f | 11 → 10 |
| 11:00 | min_fog_off_s | 72 → 54 |
| 11:00 | min_fog_on_s | 59.25 → 66 |
| 11:00 | vent_prefer_dp_delta_f | 6 → 3 |
| 11:00 | vent_prefer_temp_delta_f | 8 → 4 |
| 17:00 | cold_vent_guard_delta_f | 8 → 12 |
| 17:00 | direct_wet_stress_min_dew_margin_f | 10 → 11 |
| 17:00 | min_fog_off_s | 54 → 72 |
| 17:00 | min_fog_on_s | 66 → 59.25 |
| 17:00 | vent_prefer_dp_delta_f | 3 → 6 |
| 17:00 | vent_prefer_temp_delta_f | 4 → 8 |
| 09:00 | cold_vent_guard_delta_f | 12 → 8 |
| 09:00 | direct_wet_stress_min_dew_margin_f | 11 → 10 |
| 09:00 | min_fog_off_s | 72 → 60 |
| 09:00 | min_fog_on_s | 59.25 → 63.75 |
| 09:00 | vent_prefer_dp_delta_f | 6 → 3 |
| 09:00 | vent_prefer_temp_delta_f | 8 → 4 |
| 09:00 | cold_vent_guard_delta_f | 8 → 10 |
| 09:00 | min_fog_off_s | 60 → 72 |
| 09:00 | min_fog_on_s | 63.75 → 59.25 |
| 09:00 | vent_prefer_dp_delta_f | 3 → 4 |
| 09:00 | vent_prefer_temp_delta_f | 4 → 6 |
🌆 Evening Cycle (3:39 PM) — iris-20261110-1535
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261110-0642
Result: Plan-specific window 15:39-16:52 MDT (~1.22h), not a full-day result. The supplied window row reports planner score 76.9, compliance 62.0%, temp 96.9%, VPD 63.8%, nominal cold 0.04h, VPD-low 0.44h, and no heat/VPD-high/dew-risk. The near-term temperature/VPD calibration diagnosis was consistent with the event’s corrected-vs-raw forecast context, but the window is too brief to demonstrate a moisture or frost-night effect; persistence/consumed targets, cost, and physical crop outcomes are unavailable. No durable lesson. Score: 4/10
Hypothesis
Testing: Operational forecast-deviation response; distinguish outdoor nowcast error from live greenhouse demand. Expected outcome: Keep measured-edge moisture support available through recovery, avoid forecast-only wetting, preserve a 10°F dew-margin floor through the 34°F frost night, and reopen modest support only on observed VPD rise above the 0.90 high edge. No crop or resource benefit assumed.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 15:35 | hyst 0.15625 | Live house is modestly above both edges; retain dew-safe mea |
| 17:00 | hyst 0.15625 | Evening cooling and forecast VPD decline favor taper; keep o |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 15:35 | s2 1.5625000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Live house is modestly above both edges; retain dew-safe mea |
| 17:00 | s2 1.6425; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Evening cooling and forecast VPD decline favor taper; keep o |
Wednesday November 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.15625 | After the 34°F frost low, avoid wetting the forecast low-VPD |
| 11:00 | hyst 0.15625 | Forecast dry ramp is a cue to watch, not actuate; open assis |
| 17:00 | hyst 0.15625 | Taper after the forecast peak while preserving bounded recov |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.6725; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | After the 34°F frost low, avoid wetting the forecast low-VPD |
| 11:00 | s2 1.59; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7 | Forecast dry ramp is a cue to watch, not actuate; open assis |
| 17:00 | s2 1.6725; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Taper after the forecast peak while preserving bounded recov |
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.15625 | Cool dawn then dry ramp; use forecast corrections conservati |
| 12:00 | hyst 0.15625 | Forecast VPD reaches about 1.7-2.0 outdoors; maintain band-c |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.53; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cool dawn then dry ramp; use forecast corrections conservati |
| 12:00 | s2 1.43; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7 | Forecast VPD reaches about 1.7-2.0 outdoors; maintain band-c |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.15625 | Cloudier forecast and prior frost favor conservative, live-c |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cloudier forecast and prior frost favor conservative, live-c |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 15:35 | band_track_fraction | initial 0 |
| 15:35 | cold_vent_guard_delta_f | initial 9 |
| 15:35 | cool_stage2_exit_hysteresis_f | initial 1 |
| 15:35 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 15:35 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 15:35 | dwell_gate_ms | initial 210000 |
| 15:35 | enthalpy_close | initial 1 |
| 15:35 | enthalpy_open | initial -2 |
| 15:35 | fog_escalation_kpa | initial 0.2 |
| 15:35 | heat_hysteresis | initial 1 |
| 15:35 | min_fog_off_s | initial 54 |
| 15:35 | min_fog_on_s | initial 66 |
| 15:35 | mist_backoff_s | initial 600 |
| 15:35 | mist_max_closed_vent_s | initial 600 |
| 15:35 | mist_thermal_relief_s | initial 90 |
| 15:35 | mister_all_delay_s | initial 75 |
| 15:35 | mister_engage_delay_s | initial 37.5 |
| 15:35 | mister_water_budget_gal | initial 120 |
| 15:35 | night_vpd_bias_kpa | initial 0 |
| 15:35 | outdoor_staleness_max_s | initial 600 |
| 15:35 | sw_dwell_gate_enabled | initial 1 |
| 15:35 | sw_fog_closes_vent | initial 1 |
| 15:35 | sw_mister_closes_vent | initial 0 |
| 15:35 | sw_summer_vent_enabled | initial 1 |
| 15:35 | temp_hysteresis | initial 1.6 |
| 15:35 | vent_exchange_fraction | initial 0.3 |
| 15:35 | vent_prefer_dp_delta_f | initial 5 |
| 15:35 | vent_prefer_temp_delta_f | initial 5 |
| 15:35 | vpd_watch_dwell_s | initial 52.5 |
| 17:00 | cold_vent_guard_delta_f | 9 → 10 |
| 17:00 | min_fog_off_s | 54 → 72 |
| 17:00 | min_fog_on_s | 66 → 59.25 |
| 17:00 | vent_prefer_dp_delta_f | 5 → 6 |
| 17:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 07:00 | cold_vent_guard_delta_f | 10 → 11 |
| 07:00 | vent_prefer_dp_delta_f | 6 → 7 |
| 07:00 | vent_prefer_temp_delta_f | 6 → 7 |
| 11:00 | cold_vent_guard_delta_f | 11 → 9 |
| 11:00 | min_fog_off_s | 72 → 60 |
| 11:00 | min_fog_on_s | 59.25 → 63.75 |
| 11:00 | vent_prefer_dp_delta_f | 7 → 6 |
| 11:00 | vent_prefer_temp_delta_f | 7 → 5 |
| 17:00 | cold_vent_guard_delta_f | 9 → 10 |
| 17:00 | min_fog_off_s | 60 → 72 |
| 17:00 | min_fog_on_s | 63.75 → 59.25 |
| 17:00 | vent_prefer_temp_delta_f | 5 → 6 |
| 09:00 | cold_vent_guard_delta_f | 10 → 9 |
| 09:00 | vent_prefer_temp_delta_f | 6 → 5 |
| 12:00 | min_fog_off_s | 72 → 60 |
| 12:00 | min_fog_on_s | 59.25 → 63.75 |
| 09:00 | cold_vent_guard_delta_f | 9 → 10 |
| 09:00 | min_fog_off_s | 60 → 72 |
| 09:00 | min_fog_on_s | 63.75 → 59.25 |
| 09:00 | vent_prefer_dp_delta_f | 6 → 7 |
| 09:00 | vent_prefer_temp_delta_f | 5 → 6 |
🌆 Evening Cycle (4:52 PM) — iris-20261110-1648
validated
2/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261110-0642
Result: Plan-specific window 16:52-16:55 MDT (~3 minutes). The supplied window row reports planner score 76.9, compliance 62.0%, temp 96.9%, VPD 63.8%, and only 0.02h nominal VPD-low stress with no heat/cold/VPD-high/dew-risk. This is far too short to test the overnight low-wet/frost hypothesis; scorecard values appear dominated by sparse-window/fallback behavior rather than a meaningful treatment response. No causal, resource, or crop conclusion and no durable lesson. Score: 2/10
Hypothesis
Expected outcome: Overnight cold stress under 1h, VPD-low stress under 2h, and dew-risk 0h; keep measured-edge recovery available until house VPD is back below 0.90. Predictions use unverified historical bands, not crop outcomes.
Conditions
64.0°F
16.0%
504.0 W/m²
47.0%
At sunset the house is 72.9F/0.97 kPa with a 12.5F dew margin, slightly above the 0.90 VPD high edge; forecast low is 34F near 06:00 (near-term outdoor temperature bias is about -2.1F). Today’s partial score is 74 versus 7-day 76.3; VPD-low dominates, while cost is unavailable. The prior 1535 plan still had future waypoints and was not evaluated as a completed plan.
Expected stress windows
Keep heat-first stability and conservative outdoor exchange through the 34F dawn; retain safety preemption.
Taper wet duty after observed VPD clears 0.90; retain measured high-edge recovery with a 10F dew floor.
Parameter rationale
Keep band-edge recovery available until observed VPD is at or below 0.90; target under 2h overnight VPD-low and 0h dew-risk.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:48 | hyst 0.17575000000000002 | Evening settle: retain live-edge recovery only while house V |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:48 | s2 1.6025000000000003; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Evening settle: retain live-edge recovery only while house V |
Wednesday November 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.17575000000000002 | Midnight: taper wet duty as VPD falls; preserve heat and sup |
| 05:30 | hyst 0.17575000000000002 | Pre-dawn: retain stable heat, then allow modest live-demand |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.6175000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Midnight: taper wet duty as VPD falls; preserve heat and sup |
| 05:30 | s2 1.5737500000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Pre-dawn: retain stable heat, then allow modest live-demand |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:48 | band_track_fraction | initial 0 |
| 16:48 | cold_vent_guard_delta_f | initial 11 |
| 16:48 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:48 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 16:48 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:48 | dwell_gate_ms | initial 210000 |
| 16:48 | enthalpy_close | initial 1 |
| 16:48 | enthalpy_open | initial -2 |
| 16:48 | fog_escalation_kpa | initial 0.2 |
| 16:48 | heat_hysteresis | initial 1 |
| 16:48 | min_fog_off_s | initial 66 |
| 16:48 | min_fog_on_s | initial 61.5 |
| 16:48 | mist_backoff_s | initial 600 |
| 16:48 | mist_max_closed_vent_s | initial 600 |
| 16:48 | mist_thermal_relief_s | initial 90 |
| 16:48 | mister_all_delay_s | initial 75 |
| 16:48 | mister_engage_delay_s | initial 37.5 |
| 16:48 | mister_water_budget_gal | initial 120 |
| 16:48 | night_vpd_bias_kpa | initial 0 |
| 16:48 | outdoor_staleness_max_s | initial 600 |
| 16:48 | sw_dwell_gate_enabled | initial 1 |
| 16:48 | sw_fog_closes_vent | initial 1 |
| 16:48 | sw_mister_closes_vent | initial 0 |
| 16:48 | sw_summer_vent_enabled | initial 1 |
| 16:48 | temp_hysteresis | initial 1.6 |
| 16:48 | vent_exchange_fraction | initial 0.3 |
| 16:48 | vent_prefer_dp_delta_f | initial 5 |
| 16:48 | vent_prefer_temp_delta_f | initial 7 |
| 16:48 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | cold_vent_guard_delta_f | 11 → 12 |
| 00:00 | min_fog_off_s | 66 → 72 |
| 00:00 | min_fog_on_s | 61.5 → 59.25 |
| 00:00 | vent_prefer_temp_delta_f | 7 → 8 |
| 05:30 | cold_vent_guard_delta_f | 12 → 11 |
| 05:30 | vent_prefer_temp_delta_f | 8 → 7 |
🌆 Evening Cycle (4:55 PM) — iris-20261110-1652
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261110-0642
Result: Plan-window evidence only (0.308 d, about 7.4 h; 16:55 Nov 10 to 00:18 Nov 11 MDT): contract-2 planner_score 72.5, binary temp/VPD compliance 94.9%/62.0%, nominal cold 0.10 h, VPD-low 0.79 h, heat/VPD-high/dew-risk 0. Forecast/frost-safe, low-wet intent was partly consistent with low cold and no plan-window dew-risk, but VPD-low persisted and the hypothesis’s daytime ramp could not be tested in this window. Full Nov 10 scorecard: planner_score 76.8, binary temp/VPD 96.9%/63.8%, stress 9.41 nominal h (VPD-low 8.58, cold 0.75, VPD-high 0.08), min dew margin 3.7F and 0.1h dp-risk. Resource costs unavailable. Realized solar-night diagnostic available: 10 admitted heat-assist episodes, 3 ineffective and 7 insufficient-evidence, 0 effective/blocked, safety gates passed; 0 daytime dry-action or hold-admission samples. This is not evidence of effective dry-out or complete daylight coverage and extends beyond this plan’s window. No causal crop/resource benefit established; no durable lesson extracted. Score: 5/10
Hypothesis
Expected outcome: Keep dew-risk near 0 and cold-stress controlled overnight; avoid forecast-only wetting, then allow measured band-edge VPD recovery. Evaluate only from the plan window; no causal or resource claim.
Setpoints
Tuesday November 10
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:52 | hyst 0.1765 | Cloud miss only; preserve frost-safe night and dew-gated liv |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:52 | s2 1.695; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cloud miss only; preserve frost-safe night and dew-gated liv |
Wednesday November 11
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 05:30 | hyst 0.1765 | 34F dawn frost and low outdoor VPD; keep heat-first, avoid f |
| 11:00 | hyst 0.1765 | Reopen bounded assist only as live VPD approaches the served |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 05:30 | s2 1.75; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | 34F dawn frost and low outdoor VPD; keep heat-first, avoid f |
| 11:00 | s2 1.6625; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Reopen bounded assist only as live VPD approaches the served |
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.1765 | Correct 24-48h outdoor priors modestly; support measured dry |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.5525000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Correct 24-48h outdoor priors modestly; support measured dry |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | hyst 0.1765 | 48h+ forecast is less reliable; use cautious cold/cloud post |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | 48h+ forecast is less reliable; use cautious cold/cloud post |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:52 | band_track_fraction | initial 0 |
| 16:52 | cold_vent_guard_delta_f | initial 9 |
| 16:52 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:52 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 16:52 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:52 | dwell_gate_ms | initial 210000 |
| 16:52 | enthalpy_close | initial 1 |
| 16:52 | enthalpy_open | initial -2 |
| 16:52 | fog_escalation_kpa | initial 0.2 |
| 16:52 | heat_hysteresis | initial 1 |
| 16:52 | min_fog_off_s | initial 72 |
| 16:52 | min_fog_on_s | initial 59.25 |
| 16:52 | mist_backoff_s | initial 600 |
| 16:52 | mist_max_closed_vent_s | initial 600 |
| 16:52 | mist_thermal_relief_s | initial 90 |
| 16:52 | mister_all_delay_s | initial 75 |
| 16:52 | mister_engage_delay_s | initial 37.5 |
| 16:52 | mister_water_budget_gal | initial 120 |
| 16:52 | night_vpd_bias_kpa | initial 0 |
| 16:52 | outdoor_staleness_max_s | initial 600 |
| 16:52 | sw_dwell_gate_enabled | initial 1 |
| 16:52 | sw_fog_closes_vent | initial 1 |
| 16:52 | sw_mister_closes_vent | initial 0 |
| 16:52 | sw_summer_vent_enabled | initial 1 |
| 16:52 | temp_hysteresis | initial 1.6 |
| 16:52 | vent_exchange_fraction | initial 0.3 |
| 16:52 | vent_prefer_dp_delta_f | initial 5 |
| 16:52 | vent_prefer_temp_delta_f | initial 5 |
| 16:52 | vpd_watch_dwell_s | initial 52.5 |
| 05:30 | cold_vent_guard_delta_f | 9 → 11 |
| 05:30 | vent_prefer_temp_delta_f | 5 → 7 |
| 11:00 | cold_vent_guard_delta_f | 11 → 9 |
| 11:00 | direct_wet_stress_min_dew_margin_f | 10 → 9 |
| 11:00 | vent_prefer_dp_delta_f | 5 → 4 |
| 11:00 | vent_prefer_temp_delta_f | 7 → 5 |
| 06:00 | cold_vent_guard_delta_f | 9 → 11 |
| 06:00 | direct_wet_stress_min_dew_margin_f | 9 → 10 |
| 06:00 | vent_prefer_dp_delta_f | 4 → 5 |
| 06:00 | vent_prefer_temp_delta_f | 5 → 7 |
End-of-Day Summary
Climate
59.1–78.1°F; avg 67.9°F
0.29–1.48 kPa; avg 0.85 kPa
37.8–88.1%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
par_quantum_sensor_canopy - Validity:
dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 0.1h
- Cold stress (<55°F): 0.8h
Economics
Not available
USD 1.69
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 24 min | Primary exhaust runtime. |
| Fan 2 | 14 min | Secondary exhaust runtime. |
| Vent | 28 min | Intake vent runtime. |
| Fog | 1 min | Fogger runtime. |
| Heat 1 electric | 1312 min | Electric heater runtime. |
| Heat 2 gas | 163 min | Gas heater runtime. |
| Grow lights | 1320 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Vanda Orchids | center | 87% | 3 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Plants appear healthy with good root development visible in hanging baskets; no signs of stress or disease. || Plants appear healthy with green foliage; no visible wilting, yellowing, or pest damage. Roots are exposed and appear normal. || Plants appear turgid and healthy; no visible signs of stress or disease.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 73.5°F | 1.02 kPa | 63.7% |
| 11:00 | 76.4°F | 1.13 kPa | 63.7% |
| 12:00 | 75.8°F | 1.10 kPa | 64.0% |
| 13:00 | 76.8°F | 1.18 kPa | 62.6% |
| 14:00 | 81.0°F | 1.14 kPa | 68.5% |
| 15:00 | 82.0°F | 1.05 kPa | 72.1% |
| 16:00 | 76.9°F | 0.84 kPa | 73.2% |
| 17:00 | 71.8°F | 0.93 kPa | 65.2% |
| 18:00 | 69.6°F | 0.83 kPa | 66.5% |
| 19:00 | 69.0°F | 0.85 kPa | 65.0% |
| 20:00 | 66.9°F | 0.87 kPa | 61.4% |
| 21:00 | 64.4°F | 0.78 kPa | 62.4% |
| 22:00 | 62.9°F | 0.75 kPa | 61.6% |
| 23:00 | 61.5°F | 0.71 kPa | 62.2% |
| 00:00 | 60.8°F | 0.59 kPa | 68.0% |
| 01:00 | 60.1°F | 0.53 kPa | 70.6% |
| 02:00 | 59.6°F | 0.51 kPa | 71.1% |
| 03:00 | 61.0°F | 0.71 kPa | 61.3% |
| 04:00 | 61.6°F | 0.78 kPa | 58.3% |
| 05:00 | 62.8°F | 0.83 kPa | 57.7% |
| 06:00 | 64.0°F | 0.75 kPa | 62.9% |
| 07:00 | 67.0°F | 0.53 kPa | 76.6% |
| 08:00 | 68.0°F | 0.75 kPa | 68.0% |
| 09:00 | 70.4°F | 0.86 kPa | 66.0% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-11-04 | 0.0h | 0.4h | 0.8h |
| 2026-11-05 | 0.0h | 0.7h | 1.4h |
| 2026-11-06 | 0.0h | 0.0h | 0.6h |
| 2026-11-07 | 0.0h | 0.0h | 0.7h |
| 2026-11-08 | 0.0h | 0.2h | 0.7h |
| 2026-11-09 | 0.0h | 0.1h | 0.5h |
| 2026-11-10 | 0.0h | 0.1h | 0.8h |