November 12, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:15 | MIDNIGHT | plan_written | Wrote public plan iris-20261112-0015. Resolved 00:18 MDT. |
| Morning planning cycle | 06:43 | SUNRISE | plan_written | Wrote public plan iris-20261112-0644. Resolved 06:47 MDT. |
| Solar peak planning checkpoint | 11:44 | SOLAR_MAX | acked | Acknowledged: No tunable change: live solar 559 W/m² is close to the fresher 12:00 partial-window nowcast of 562 despite the hourly forecast at 493; indoor VPD is 1.22 kPa with 14.6°F dew margin and has not shown a material acceleration. Existing plan already provides band-edge mist/fog posture for the afternoon; avoid extra wetting without clearer demand. Resolved 11:46 MDT. |
| Peak Stress | 13:45 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 13:46 MDT. |
| Decline | 15:47 | TRANSITION | acked | Acknowledged: No tunable change: live controller is IDLE with climate relays off and 10.3F dew margin; upcoming plan already tapers mist/fog at 16:00 and widens the gap again at 19:00. Keep band-edge recovery available while VPD is still near/above its edge; forecast cools quickly toward sub-edge VPD and the day’s VPD-low stress is dominant. Resolved 15:48 MDT. |
| Evening planning cycle | 16:46 | SUNSET | plan_written | Wrote public plan iris-20261112-1647. Resolved 16:51 MDT. |
| Forecast deviation | 16:55 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261112-1655. Resolved 16:57 MDT. |
🌅 Morning Cycle (12:18 AM) — iris-20261112-0015
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261111-1654
Previous hypothesis: Observed cloud cover was 97.39% versus 0% forecast at 16:54 MST, but solar was already 3 W/m² and the forecast put the cloud increase after 22:00. Fresh climate is 72.9°F, VPD 1.15 kPa, dew margin 14.8°F; all climate relays are off. This is a dusk cloud/forecast-timing miss, not evidence of equipment failure or a confirmed sustained regime change; no quantitative cloud calibration is available. Keep frost-safe, low-wet overnight posture for the 38–39°F Thursday dawn, reopen band-coupled measured-VPD assist for Thursday’s dry ramp, taper for Friday’s 34°F cloudy dawn, then reopen cautiously Saturday. Apply only lead-matched temperature/VPD forecast corrections; preserve dispatcher-owned crop bands and avoid causal crop/resource claims. Prior completed 0643 plan was already graded 5 vs anchor 4; its partial window and guardrail holds limited attribution. Result: Window-scoped 0.270 d only: planner_score 73.6; contract-2 binary temp/VPD 97.5%/71.9%; nominal cold 0.11 h, VPD-high 0.02 h, VPD-low 1.23 h; dew-risk 0 h. Frost-safe/low-wet posture had little cold stress and no dew-risk, but VPD-low remained the main miss; attribution and costs unavailable, so partial result only. Score: 5/10
Hypothesis
Expected outcome: Keep overnight dew margin at or above 10°F and avoid adding moisture while live VPD remains below band; expose bounded band-edge assist by 10:00 for the forecast dry ramp without exceeding the 120-gal mist budget. Judge effects only from later qualified evidence.
Setpoints
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.23625000000000002 | Post-midnight: honor VPD-low alert; heat-first and no unnece |
| 04:30 | hyst 0.23625000000000002 | Pre-dawn low near 37°F; preserve heat and a 10°F dew-margin |
| 06:45 | hyst 0.23625000000000002 | Sunrise ramp: delay wetting through the cool low-VPD shoulde |
| 10:00 | hyst 0.23625000000000002 | Dry-ramp handoff: make edge-coupled mist/fog available only |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.7025000000000001; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.3 | Post-midnight: honor VPD-low alert; heat-first and no unnece |
| 04:30 | s2 1.7025000000000001; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.3 | Pre-dawn low near 37°F; preserve heat and a 10°F dew-margin |
| 06:45 | s2 1.6725; cool_exit 1.78; all_fans 0; dw_stress 0; engage 1.05; all 1.25; pulse 30; gap 52.5; wt 1.3866666666666667 | Sunrise ramp: delay wetting through the cool low-VPD shoulde |
| 10:00 | s2 1.51; cool_exit 1.78; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.6666666666666665 | Dry-ramp handoff: make edge-coupled mist/fog available only |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 12 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 00:15 | dwell_gate_ms | initial 240000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.4 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 102 |
| 00:15 | min_fog_on_s | initial 48 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 84 |
| 00:15 | mister_engage_delay_s | initial 42 |
| 00:15 | mister_water_budget_gal | initial 120 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 1.78 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 6 |
| 00:15 | vent_prefer_temp_delta_f | initial 8 |
| 00:15 | vpd_watch_dwell_s | initial 60 |
| 06:45 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.15 |
| 06:45 | fog_escalation_kpa | 0.4 → 0.35 |
| 06:45 | min_fog_off_s | 102 → 90 |
| 06:45 | min_fog_on_s | 48 → 52.5 |
| 10:00 | cold_vent_guard_delta_f | 12 → 10 |
| 10:00 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.15 → 0.05 |
| 10:00 | fog_escalation_kpa | 0.35 → 0.2 |
| 10:00 | min_fog_off_s | 90 → 60 |
| 10:00 | min_fog_on_s | 52.5 → 63.75 |
| 10:00 | vent_prefer_dp_delta_f | 6 → 4 |
| 10:00 | vent_prefer_temp_delta_f | 8 → 6 |
🌅 Morning Cycle (6:47 AM) — iris-20261112-0644
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261111-1654
Result: SUNSET cutoff after 0.416 d (~10.0 h) of iris-20261112-0644: scoped window planner_score 73.5; contract-2 binary temp/VPD 97.5%/71.9%; nominal cold 0.17 h, VPD-high 0.03 h, VPD-low 1.91 h; dew-risk 0 h (daily minimum margin 5.7°F). Midday VPD-high stayed below the plan’s <2 h target, but VPD-low remained the dominant miss; the planned evening taper/recovery and overnight forecast window were not tested because the 19:00 waypoint was still future. Guardrail audit had 36 matched, 17 already-at-value, and one missed fog_escalation_kpa write (requested 0.25, actual 0.15), so attribution is limited. Cost unavailable; target consumption, continuous exposure, and physical crop outcome are unverified. Score: 5/10
Hypothesis
Testing: Test a low-duty dawn to band-coupled midday handoff: avoid forecast-only wetting, open assist near measured high-band excess, and keep a small recovery shoulder into evening. Expected outcome: Keep dawn dew margin at least 10°F with little or no VPD-low exposure; during the measured dry ramp retain band-edge wet assist and keep VPD-high stress below 2 h; taper only after observed VPD recovery, with dew-risk at 0 h. Cost and physical crop effects remain unverified.
Conditions
68.0°F
18.0%
497.0 W/m²
0.0%
Nov 12: 37F forecast dawn, clear ramp, 68F high, outdoor VPD peak 1.90. Current house 66F/0.95 kPa, 15.9F dew margin. Nov 11 score 77; contract-2 temp/VPD 98.6/66.3%, VPD-low 8.08h dominated, VPD-high 0h; water 32 gal, costs unavailable. Prior 1654 self-grade 6 vs anchor 2: 126 VPD-high guardrail events (102 held) weaken execution attribution.
Expected stress windows
Measured band-edge assist with low-to-moderate duty; fog only for persistent excess while dew margin is safe.
Reduce duty and keep a small live-edge recovery shoulder; do not wet solely from forecast or clock.
Parameter rationale
Make first-stage assist reachable at the measured band edge while limiting humid-dawn over-wetting.
Allow all-zone rotation only after additional band-relative excess, balancing afternoon recovery against overshoot.
Reserve heavy fog for persistent measured excess rather than routine dawn or marginal VPD demand.
Setpoints
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:43 | hyst 0.1865 | Dawn: frost-safe heat posture; keep only modest live VPD-edg |
| 09:30 | hyst 0.1865 | Morning ramp: raise duty only as live VPD approaches or exce |
| 13:00 | hyst 0.1865 | Peak dry ramp: compliance-first wet assist, but avoid high d |
| 16:00 | hyst 0.1865 | Decline: taper gradually; retain assist until measured VPD i |
| 19:00 | hyst 0.1865 | Evening: prevent VPD-low overshoot while preserving a small |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:43 | s2 1.5725000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Dawn: frost-safe heat posture; keep only modest live VPD-edg |
| 09:30 | s2 1.5050000000000001; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 26.25; wt 1.7333333333333334 | Morning ramp: raise duty only as live VPD approaches or exce |
| 13:00 | s2 1.47; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 26.25; wt 1.7333333333333334 | Peak dry ramp: compliance-first wet assist, but avoid high d |
| 16:00 | s2 1.5725000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Decline: taper gradually; retain assist until measured VPD i |
| 19:00 | s2 1.6900000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Evening: prevent VPD-low overshoot while preserving a small |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:43 | band_track_fraction | initial 0 |
| 06:43 | cold_vent_guard_delta_f | initial 8 |
| 06:43 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:43 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 06:43 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:43 | dwell_gate_ms | initial 210000 |
| 06:43 | enthalpy_close | initial 1 |
| 06:43 | enthalpy_open | initial -2 |
| 06:43 | fog_escalation_kpa | initial 0.25 |
| 06:43 | heat_hysteresis | initial 1 |
| 06:43 | min_fog_off_s | initial 54 |
| 06:43 | min_fog_on_s | initial 66 |
| 06:43 | mist_backoff_s | initial 600 |
| 06:43 | mist_max_closed_vent_s | initial 600 |
| 06:43 | mist_thermal_relief_s | initial 90 |
| 06:43 | mister_all_delay_s | initial 75 |
| 06:43 | mister_engage_delay_s | initial 37.5 |
| 06:43 | mister_water_budget_gal | initial 120 |
| 06:43 | night_vpd_bias_kpa | initial 0 |
| 06:43 | outdoor_staleness_max_s | initial 600 |
| 06:43 | sw_dwell_gate_enabled | initial 1 |
| 06:43 | sw_fog_closes_vent | initial 1 |
| 06:43 | sw_mister_closes_vent | initial 0 |
| 06:43 | sw_summer_vent_enabled | initial 1 |
| 06:43 | temp_hysteresis | initial 1.6 |
| 06:43 | vent_exchange_fraction | initial 0.3 |
| 06:43 | vent_prefer_dp_delta_f | initial 3 |
| 06:43 | vent_prefer_temp_delta_f | initial 4 |
| 06:43 | vpd_watch_dwell_s | initial 52.5 |
| 09:30 | direct_wet_stress_min_dew_margin_f | 10 → 8 |
| 09:30 | min_fog_off_s | 54 → 48 |
| 09:30 | min_fog_on_s | 66 → 68.25 |
| 13:00 | fog_escalation_kpa | 0.25 → 0.2 |
| 16:00 | direct_wet_stress_min_dew_margin_f | 8 → 9 |
| 16:00 | fog_escalation_kpa | 0.2 → 0.25 |
| 16:00 | min_fog_off_s | 48 → 54 |
| 16:00 | min_fog_on_s | 68.25 → 66 |
| 19:00 | direct_wet_stress_min_dew_margin_f | 9 → 10 |
| 19:00 | min_fog_off_s | 54 → 66 |
| 19:00 | min_fog_on_s | 66 → 61.5 |
🌆 Evening Cycle (4:51 PM) — iris-20261112-1647
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261112-0644
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:68.0,“outdoor_rh_min_pct”:18.0,“solar_peak_w_m2”:497.0,“cloud_cover_avg_pct”:0.0,“notes”:“Nov 12: 37F forecast dawn, clear ramp, 68F high, outdoor VPD peak 1.90. Current house 66F/0.95 kPa, 15.9F dew margin. Nov 11 score 77; contract-2 temp/VPD 98.6/66.3%, VPD-low 8.08h dominated, VPD-high 0h; water 32 gal, costs unavailable. Prior 1654 self-grade 6 vs anchor 2: 126 VPD-high guardrail events (102 held) weaken execution attribution.”},“stress_windows”:[{“kind”:“vpd_high”,“start”:“2026-11-12T10:30:00-07:00”,“end”:“2026-11-12T16:00:00-07:00”,“severity”:“medium”,“mitigation”:“Measured band-edge assist with low-to-moderate duty; fog only for persistent excess while dew margin is safe… Result: Evaluated only the plan-scoped WINDOW SCORECARD for iris-20261112-1647: its governed interval was just 0.004 day (~6 minutes) before replacement. Scoped planner_score 75.4; binary both-axis compliance 55.2%, temp 98.3%, VPD 55.6%; nominal VPD-low stress 0.04 h, no heat/cold/VPD-high stress or dew risk recorded. The interval is too short to establish whether the plan hypothesis or moisture/overnight goals were met. Full Nov 12 context was planner_score 75.4, temp/VPD binary 98.2%/56.5%, and 10.17 h nominal VPD-low stress; this whole-day result is not attributable to the six-minute plan window. Water was 36 gal; costs unavailable. Contract-2 historical desired-band metrics have unverified coverage and are not physical crop outcomes. No durable lesson supported. Score: 4/10
Hypothesis
Expected outcome: Through pre-dawn, target cold stress <1h, VPD-low <2h, VPD-high <2h and dew-risk 0h; no forecast-only wetting. Cost, consumed targets and physical crop outcome remain unverified.
Conditions
60.0°F
25.0%
447.0 W/m²
60.0%
Dusk house 74.7F/0.90 kPa, dew margin 9F; today score 73.5, temp/VPD 97.5/71.9%, VPD-low 4.58h and costs unavailable. Forecast falls to 37F with outdoor VPD 0.34 by dawn, then clouded warming. Evaluated 0644 at 5 vs anchor 6 on 0.416d: VPD-low persisted; 19:00+ overnight untested. Fresh relay reads show heat1 concurrent with vent/fan2 in DEHUM_VENT; flagged, not manipulated.
Expected stress windows
Heat-first, penalize relay churn, and require a meaningful outdoor advantage before exchange.
No forecast-only wetting; retain measured band-edge recovery and keep dew margin at least 8F.
Parameter rationale
Defer heavy fog during the cool hold; retain mist at measured high-band excess, target VPD-low below 2h and dew-risk 0h.
Setpoints
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:46 | hyst 0.176 | Evening settle: preserve band-edge wet assist; favor cold-sa |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:46 | s2 1.5875000000000001; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7 | Evening settle: preserve band-edge wet assist; favor cold-sa |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.176 | Midnight: avoid forecast-only wetting; hold dehumidification |
| 05:30 | hyst 0.176 | Pre-dawn: retain heat stability, but keep modest live-edge a |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.6175000000000002; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Midnight: avoid forecast-only wetting; hold dehumidification |
| 05:30 | s2 1.6025000000000003; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Pre-dawn: retain heat stability, but keep modest live-edge a |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:46 | band_track_fraction | initial 0 |
| 16:46 | cold_vent_guard_delta_f | initial 12 |
| 16:46 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:46 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:46 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:46 | dwell_gate_ms | initial 210000 |
| 16:46 | enthalpy_close | initial 1 |
| 16:46 | enthalpy_open | initial -2 |
| 16:46 | fog_escalation_kpa | initial 0.2 |
| 16:46 | heat_hysteresis | initial 1 |
| 16:46 | min_fog_off_s | initial 60 |
| 16:46 | min_fog_on_s | initial 63.75 |
| 16:46 | mist_backoff_s | initial 600 |
| 16:46 | mist_max_closed_vent_s | initial 600 |
| 16:46 | mist_thermal_relief_s | initial 90 |
| 16:46 | mister_all_delay_s | initial 75 |
| 16:46 | mister_engage_delay_s | initial 37.5 |
| 16:46 | mister_water_budget_gal | initial 120 |
| 16:46 | night_vpd_bias_kpa | initial 0 |
| 16:46 | outdoor_staleness_max_s | initial 600 |
| 16:46 | sw_dwell_gate_enabled | initial 1 |
| 16:46 | sw_fog_closes_vent | initial 1 |
| 16:46 | sw_mister_closes_vent | initial 0 |
| 16:46 | sw_summer_vent_enabled | initial 1 |
| 16:46 | temp_hysteresis | initial 1.6 |
| 16:46 | vent_exchange_fraction | initial 0.3 |
| 16:46 | vent_prefer_dp_delta_f | initial 5 |
| 16:46 | vent_prefer_temp_delta_f | initial 8 |
| 16:46 | vpd_watch_dwell_s | initial 52.5 |
| 00:00 | min_fog_off_s | 60 → 72 |
| 00:00 | min_fog_on_s | 63.75 → 59.25 |
| 05:30 | min_fog_off_s | 72 → 66 |
| 05:30 | min_fog_on_s | 59.25 → 61.5 |
🌆 Evening Cycle (4:57 PM) — iris-20261112-1655
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261112-0644
Result: Plan iris-20261112-1655 governed 0.306 day (~7.3 h) before replacement. Scoped contract-2 window: planner_score 67.9, binary temp/VPD 97.5%/35.5%; nominal stress cold 0.05 h, VPD-low 1.31 h, VPD-high 0; dew-risk 0.0 h. This supports frost/condensation safety but not VPD recovery; most of Nov 12’s 10.58 h VPD-low occurred outside this window, so do not attribute the daily result. Whole Nov 12 scorecard: planner_score 75.4, temp/VPD 98.3%/55.6%, stress 0 heat/0.42 cold/0.08 VPD-high/10.58 VPD-low hours, water 36 gal (mister 6); costs, therms and electric runtime-model cost unavailable. Forecast cloud deviation and guardrail missed writes limit causal attribution; historical desired-band metrics have unverified coverage and are not physical crop outcomes. Score: 5/10
Hypothesis
Expected outcome: No climate/moisture action based only on the dusk cloud mismatch; preserve frost-safe heating and zero dew-risk. Keep band-edge wet assist available if live VPD rises above the served corridor; costs and physical crop outcomes remain unverified.
Setpoints
Thursday November 12
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:54 | hyst 0.1775 | Dusk cloud miss; frost-safe low-wet hold, measured edge only |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:54 | s2 1.645; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Dusk cloud miss; frost-safe low-wet hold, measured edge only |
Friday November 13
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1775 | Cloudy dry ramp; follow live VPD and calibrated near-term fo |
| 17:00 | hyst 0.1775 | Cooling night; avoid forecast-only wetting and retain frost- |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.6525; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cloudy dry ramp; follow live VPD and calibrated near-term fo |
| 17:00 | s2 1.645; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cooling night; avoid forecast-only wetting and retain frost- |
Saturday November 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 04:00 | hyst 0.1775 | 34°F dawn risk; keep exchange conservative and wet assist bo |
| 12:00 | hyst 0.1775 | Cloudy recovery window; allow limited band-edge assist only |
| 18:00 | hyst 0.1775 | Cold, humid evening; low-wet hold with stable heat-first pos |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 04:00 | s2 1.645; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | 34°F dawn risk; keep exchange conservative and wet assist bo |
| 12:00 | s2 1.5925; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cloudy recovery window; allow limited band-edge assist only |
| 18:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cold, humid evening; low-wet hold with stable heat-first pos |
Sunday November 15
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | hyst 0.1775 | 48h+ forecast has material VPD bias; use corrected priors an |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 08:00 | s2 1.8525; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | 48h+ forecast has material VPD bias; use corrected priors an |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:54 | band_track_fraction | initial 0 |
| 16:54 | cold_vent_guard_delta_f | initial 12 |
| 16:54 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:54 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:54 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:54 | dwell_gate_ms | initial 210000 |
| 16:54 | enthalpy_close | initial 1 |
| 16:54 | enthalpy_open | initial -2 |
| 16:54 | fog_escalation_kpa | initial 0.2 |
| 16:54 | heat_hysteresis | initial 1 |
| 16:54 | min_fog_off_s | initial 72 |
| 16:54 | min_fog_on_s | initial 59.25 |
| 16:54 | mist_backoff_s | initial 600 |
| 16:54 | mist_max_closed_vent_s | initial 600 |
| 16:54 | mist_thermal_relief_s | initial 90 |
| 16:54 | mister_all_delay_s | initial 75 |
| 16:54 | mister_engage_delay_s | initial 37.5 |
| 16:54 | mister_water_budget_gal | initial 120 |
| 16:54 | night_vpd_bias_kpa | initial 0 |
| 16:54 | outdoor_staleness_max_s | initial 600 |
| 16:54 | sw_dwell_gate_enabled | initial 1 |
| 16:54 | sw_fog_closes_vent | initial 1 |
| 16:54 | sw_mister_closes_vent | initial 0 |
| 16:54 | sw_summer_vent_enabled | initial 1 |
| 16:54 | temp_hysteresis | initial 1.6 |
| 16:54 | vent_exchange_fraction | initial 0.3 |
| 16:54 | vent_prefer_dp_delta_f | initial 5 |
| 16:54 | vent_prefer_temp_delta_f | initial 8 |
| 16:54 | vpd_watch_dwell_s | initial 52.5 |
End-of-Day Summary
Climate
59.1–84.6°F; avg 68.3°F
0.42–1.66 kPa; avg 0.83 kPa
51.3–82.0%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
par_quantum_sensor_canopy - Validity:
dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (>85°F): 0.0h
- VPD stress (>2.0 kPa): 0.1h
- Cold stress (<55°F): 0.4h
Economics
Not available
USD 1.53
USD 0.170
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 12 min | Primary exhaust runtime. |
| Fan 2 | 12 min | Secondary exhaust runtime. |
| Vent | 22 min | Intake vent runtime. |
| Fog | 10 min | Fogger runtime. |
| Heat 1 electric | 1219 min | Electric heater runtime. |
| Heat 2 gas | 147 min | Gas heater runtime. |
| Grow lights | 1101 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.01h | Center mister runtime. |
Water
- Total: 36 gal
- Mister: 6 gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Vanda Orchids | center | 75% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Plants appear healthy with green foliage and visible root systems. No signs of stress or damage. || Plants appear healthy with green foliage; no visible wilting, yellowing, or pest damage. Roots visible in hanging baskets are white and turgid. || Plants appear healthy with normal leaf turgor and structure. No visible signs of stress or damage. || Plants appear healthy with visible root systems; no obvious signs of stress or disease.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 73.4°F | 1.08 kPa | 61.5% |
| 11:00 | 75.6°F | 1.22 kPa | 59.7% |
| 12:00 | 75.6°F | 1.21 kPa | 59.8% |
| 13:00 | 76.1°F | 1.20 kPa | 61.1% |
| 14:00 | 79.7°F | 1.17 kPa | 66.3% |
| 15:00 | 82.7°F | 1.17 kPa | 69.7% |
| 16:00 | 76.0°F | 0.95 kPa | 69.1% |
| 17:00 | 71.3°F | 0.86 kPa | 67.3% |
| 18:00 | 70.7°F | 0.87 kPa | 66.2% |
| 19:00 | 68.0°F | 0.77 kPa | 67.1% |
| 20:00 | 66.5°F | 0.81 kPa | 63.5% |
| 21:00 | 65.4°F | 0.82 kPa | 61.6% |
| 22:00 | 62.6°F | 0.68 kPa | 65.0% |
| 23:00 | 61.7°F | 0.61 kPa | 67.7% |
| 00:00 | 61.2°F | 0.67 kPa | 63.6% |
| 01:00 | 60.0°F | 0.69 kPa | 61.3% |
| 02:00 | 60.0°F | 0.65 kPa | 63.5% |
| 03:00 | 60.9°F | 0.79 kPa | 57.0% |
| 04:00 | 61.3°F | 0.79 kPa | 57.6% |
| 05:00 | 62.7°F | 0.80 kPa | 59.1% |
| 06:00 | 64.0°F | 0.84 kPa | 59.1% |
| 07:00 | 66.3°F | 0.57 kPa | 74.1% |
| 08:00 | 67.7°F | 0.74 kPa | 68.2% |
| 09:00 | 70.9°F | 0.89 kPa | 65.3% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-11-06 | 0.0h | 0.0h | 0.6h |
| 2026-11-07 | 0.0h | 0.0h | 0.7h |
| 2026-11-08 | 0.0h | 0.2h | 0.7h |
| 2026-11-09 | 0.0h | 0.1h | 0.5h |
| 2026-11-10 | 0.0h | 0.1h | 0.8h |
| 2026-11-11 | 0.0h | 0.0h | 0.3h |
| 2026-11-12 | 0.0h | 0.1h | 0.4h |