November 14, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
7
4
1
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:15 | MIDNIGHT | plan_written | Wrote public plan iris-20261114-0015. Resolved 00:18 MDT. |
| Morning planning cycle | 06:45 | SUNRISE | plan_written | Wrote public plan iris-20261114-0645. Resolved 06:50 MDT. |
| Forecast deviation | 10:55 | FORECAST_DEVIATION | plan_written | Wrote public plan iris-20261114-1055. Resolved 10:58 MDT. |
| Solar peak planning checkpoint | 11:45 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 11:46 MDT. |
| Peak Stress | 13:45 | TRANSITION | action_completed | Delivery recorded without a public plan write. Resolved 13:47 MDT. |
| Decline | 15:45 | TRANSITION | acked | Acknowledged: No immediate override: current VPD is still 1.11 kPa above the 0.90 high edge with 13.2°F dew margin, while occupancy blocks wet/fog. The governing plan already tapers at 17:00 (engage 1.0, all-zone 1.2, gap 41s, fog escalation 0.2), matching the cold, humid forecast; keep band-edge recovery available until that waypoint rather than suppressing it early. Resolved 15:46 MDT. |
| Evening planning cycle | 16:44 | SUNSET | plan_written | Wrote public plan iris-20261114-1645. Resolved 16:48 MDT. |
🌅 Morning Cycle (12:18 AM) — iris-20261114-0015
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261113-1646
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:53,“outdoor_rh_min_pct”:30,“solar_peak_w_m2”:3,“cloud_cover_avg_pct”:99,“notes”:“Nov13 partial contract-2 score72.9; temp/VPD binary97.5/59.8%, VPD-low6.67h, cold0.42h, dew-risk0.2h; current72F/0.81kPa, margin10.4F. Forecast raw low35F, RH99%, near-zero solar. Prior iris-20261113-0015 grade5 vs anchor2: over-credited stable axes and underweighted 42 guardrail events (21 held) and VPD-low.”},“stress_windows”:[{“kind”:“cold”,“start”:“2026-11-13T18:00:00-07:00”,“end”:“2026-11-14T05:30:00-07:00”,“severity”:“high”,“mitigation”:“Preserve stable heat and require a meaningful outdoor advantage before exchange; penalize ordinary relay churn… Result: Scoped completed window 00:18-06:50 MST (0.272d): contract-2 binary joint compliance 44.9%, temp 95.3%, VPD 46.5%; nominal cold stress 0.14h, VPD-low 1.54h, VPD-high 0h, dew-risk 0h. This is mixed evidence: temperature control and avoidance of high-VPD/dew-risk matched the conservative cold-night aim, but substantial VPD-low and low joint compliance remain. Costs, coverage, consumed-target confirmation and physical crop outcomes are unavailable; no causal benefit is established. Score: 4/10
Hypothesis
Expected outcome: Through the 10:30 handoff: no VPD-high or dew-risk hours, and at most 1 nominal VPD-low hour; resource-cost evidence is unavailable.
Setpoints
Saturday November 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | hyst 0.2565 | Hold frost-night posture; VPD is in band and current dew mar |
| 04:30 | hyst 0.2615 | Coldest saturated hours; suppress extra wetting and reduce c |
| 07:00 | hyst 0.2565 | Cold, cloudy sunrise; retain only measured band-edge assist |
| 10:30 | hyst 0.2515 | Cloudy cool ramp; avoid wetting absent live VPD excess and h |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:15 | s2 1.7525000000000002; cool_exit 2.14; all_fans 1; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.2 | Hold frost-night posture; VPD is in band and current dew mar |
| 04:30 | s2 1.8025000000000002; cool_exit 2.23; all_fans 1; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 60; wt 1.1333333333333333 | Coldest saturated hours; suppress extra wetting and reduce c |
| 07:00 | s2 1.7375000000000003; cool_exit 2.14; all_fans 1; dw_stress 0; engage 1.05; all 1.2; pulse 30; gap 60; wt 1.2333333333333334 | Cold, cloudy sunrise; retain only measured band-edge assist |
| 10:30 | s2 1.7375000000000003; cool_exit 2.05; all_fans 1; dw_stress 0; engage 1.05; all 1.2; pulse 30; gap 60; wt 1.2333333333333334 | Cloudy cool ramp; avoid wetting absent live VPD excess and h |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:15 | band_track_fraction | initial 0 |
| 00:15 | cold_vent_guard_delta_f | initial 14 |
| 00:15 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:15 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 00:15 | direct_wet_stress_vpd_margin_kpa | initial 0.2 |
| 00:15 | dwell_gate_ms | initial 300000 |
| 00:15 | enthalpy_close | initial 1 |
| 00:15 | enthalpy_open | initial -2 |
| 00:15 | fog_escalation_kpa | initial 0.4 |
| 00:15 | heat_hysteresis | initial 1 |
| 00:15 | min_fog_off_s | initial 126 |
| 00:15 | min_fog_on_s | initial 39 |
| 00:15 | mist_backoff_s | initial 600 |
| 00:15 | mist_max_closed_vent_s | initial 600 |
| 00:15 | mist_thermal_relief_s | initial 90 |
| 00:15 | mister_all_delay_s | initial 102 |
| 00:15 | mister_engage_delay_s | initial 51 |
| 00:15 | mister_water_budget_gal | initial 100 |
| 00:15 | night_vpd_bias_kpa | initial 0 |
| 00:15 | outdoor_staleness_max_s | initial 600 |
| 00:15 | sw_dwell_gate_enabled | initial 1 |
| 00:15 | sw_fog_closes_vent | initial 1 |
| 00:15 | sw_mister_closes_vent | initial 0 |
| 00:15 | sw_summer_vent_enabled | initial 1 |
| 00:15 | temp_hysteresis | initial 2.14 |
| 00:15 | vent_exchange_fraction | initial 0.3 |
| 00:15 | vent_prefer_dp_delta_f | initial 8 |
| 00:15 | vent_prefer_temp_delta_f | initial 10 |
| 00:15 | vpd_watch_dwell_s | initial 75 |
| 04:30 | cold_vent_guard_delta_f | 14 → 15 |
| 04:30 | dwell_gate_ms | 300000 → 315000 |
| 04:30 | fog_escalation_kpa | 0.4 → 0.45 |
| 04:30 | min_fog_off_s | 126 → 132 |
| 04:30 | min_fog_on_s | 39 → 36.75 |
| 04:30 | mister_all_delay_s | 102 → 106.5 |
| 04:30 | mister_engage_delay_s | 51 → 53.25 |
| 04:30 | temp_hysteresis | 2.14 → 2.23 |
| 04:30 | vent_prefer_dp_delta_f | 8 → 9 |
| 04:30 | vent_prefer_temp_delta_f | 10 → 12 |
| 04:30 | vpd_watch_dwell_s | 75 → 78.75 |
| 07:00 | cold_vent_guard_delta_f | 15 → 14 |
| 07:00 | direct_wet_stress_min_dew_margin_f | 10 → 9 |
| 07:00 | direct_wet_stress_vpd_margin_kpa | 0.2 → 0.15 |
| 07:00 | dwell_gate_ms | 315000 → 300000 |
| 07:00 | fog_escalation_kpa | 0.45 → 0.4 |
| 07:00 | min_fog_off_s | 132 → 120 |
| 07:00 | min_fog_on_s | 36.75 → 41.25 |
| 07:00 | mister_all_delay_s | 106.5 → 102 |
| 07:00 | mister_engage_delay_s | 53.25 → 51 |
| 07:00 | temp_hysteresis | 2.23 → 2.14 |
| 07:00 | vent_prefer_dp_delta_f | 9 → 8 |
| 07:00 | vent_prefer_temp_delta_f | 12 → 10 |
| 07:00 | vpd_watch_dwell_s | 78.75 → 75 |
| 10:30 | cold_vent_guard_delta_f | 14 → 13 |
| 10:30 | direct_wet_stress_min_dew_margin_f | 9 → 8 |
| 10:30 | dwell_gate_ms | 300000 → 285000 |
| 10:30 | fog_escalation_kpa | 0.4 → 0.35 |
| 10:30 | mister_all_delay_s | 102 → 97.5 |
| 10:30 | mister_engage_delay_s | 51 → 48.75 |
| 10:30 | temp_hysteresis | 2.14 → 2.05 |
| 10:30 | vent_prefer_temp_delta_f | 10 → 9 |
| 10:30 | vpd_watch_dwell_s | 75 → 71.25 |
🌅 Morning Cycle (6:50 AM) — iris-20261114-0645
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261113-1646
Result: Evaluated only the completed 2026-11-14 06:50–10:58 MST window (0.173 day): contract-2 planner score 76.9; binary joint/temp/VPD 63.8%/96.0%/65.8%; nominal cold 0.12h, VPD-low 0.98h, VPD-high 0h, dew-risk 0h. This partially supports avoiding forecast-only wetting and preserving temperature control, but the active VPD-stress alert at 10:39 reported 1.4h and 100% high in the last 15m, conflicting with the scoped scorecard’s zero VPD-high. Main hypothesis window after 10:58 was not governed/evaluated here. Costs unavailable; coverage unverified; desired bands are not confirmed consumed targets, and no physical crop outcome is available. Conservative 4/10 reflects this mixed, short-window evidence and unresolved stress/scorecard discrepancy; no causal benefit or durable lesson claimed. Score: 4/10
Hypothesis
Testing: Test modest dewpoint-selective daytime drying on a cold cloudy day; compare VPD-low and cold stress without changing crop bands. Expected outcome: By midnight, no VPD-high or dew-risk hours; reduce nominal VPD-low stress below yesterday’s 9.5h while preserving temperature control. Resource costs remain unverified.
Conditions
52.0°F
60.0%
309.0 W/m²
70.0%
Nov 13 scorecard: contract-2 planner score 77.0; binary temp/VPD 98.3%/60.4%, 9.5 nominal VPD-low h, 0 VPD-high, 0.2 dew-risk h; costs unavailable, water 33 gal vs 37-gal 7d average. Current indoor 64F/VPD 0.82, dew margin 14.3F. Today forecast 35-52F, mostly cloudy, outdoor VPD peak 0.52. Prior sunset self-grade revised to 3/10 vs anchor 1 after 349/409 guardrail actions were held; weak attribution.
Expected stress windows
No forecast-only wetting; keep band-edge mist available only on live VPD excess and safe dew margin; use selective drying exchange.
Preserve stable heat and conservative exchange through forecast 35F overnight low; keep moisture low and dew-safe.
Parameter rationale
Avoid wetting while in-band yet keep first-stage mist available at the high edge if live VPD rises.
Keep all-zone mist escalation bounded and responsive only to sustained measured excess.
Avoid heavy fog overshoot while retaining firmware-gated wet assistance for a substantial live VPD excess.
Setpoints
Saturday November 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:45 | hyst 0.21650000000000003 | Dawn: retain heat, avoid forecast-only wetting, and permit o |
| 09:00 | hyst 0.21650000000000003 | Morning ramp: selectively dehumidify only with clear outdoor |
| 14:00 | hyst 0.21150000000000002 | Peak: modest solar only; avoid target-hugging or extra water |
| 16:30 | hyst 0.21650000000000003 | Decline: taper wetting after the short solar window and pres |
| 18:00 | hyst 0.22150000000000003 | Evening: minimize wetting and cold-air exchange while retain |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:45 | s2 1.735; cool_exit 2.14; all_fans 1; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 48.75; wt 1.4333333333333333 | Dawn: retain heat, avoid forecast-only wetting, and permit o |
| 09:00 | s2 1.7000000000000002; cool_exit 2.14; all_fans 1; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 48.75; wt 1.4466666666666668 | Morning ramp: selectively dehumidify only with clear outdoor |
| 14:00 | s2 1.6475000000000002; cool_exit 2.05; all_fans 1; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 48.75; wt 1.4666666666666668 | Peak: modest solar only; avoid target-hugging or extra water |
| 16:30 | s2 1.75; cool_exit 2.14; all_fans 1; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 52.5; wt 1.3866666666666667 | Decline: taper wetting after the short solar window and pres |
| 18:00 | s2 1.705; cool_exit 2.23; all_fans 1; dw_stress 0; engage 1; all 1.2; pulse 30; gap 41.25; wt 1.4666666666666668 | Evening: minimize wetting and cold-air exchange while retain |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:45 | band_track_fraction | initial 0 |
| 06:45 | cold_vent_guard_delta_f | initial 15 |
| 06:45 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:45 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 06:45 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:45 | dwell_gate_ms | initial 300000 |
| 06:45 | enthalpy_close | initial 1 |
| 06:45 | enthalpy_open | initial -2 |
| 06:45 | fog_escalation_kpa | initial 0.5 |
| 06:45 | heat_hysteresis | initial 1 |
| 06:45 | min_fog_off_s | initial 84 |
| 06:45 | min_fog_on_s | initial 54.75 |
| 06:45 | mist_backoff_s | initial 600 |
| 06:45 | mist_max_closed_vent_s | initial 600 |
| 06:45 | mist_thermal_relief_s | initial 90 |
| 06:45 | mister_all_delay_s | initial 102 |
| 06:45 | mister_engage_delay_s | initial 51 |
| 06:45 | mister_water_budget_gal | initial 100 |
| 06:45 | night_vpd_bias_kpa | initial 0 |
| 06:45 | outdoor_staleness_max_s | initial 600 |
| 06:45 | sw_dwell_gate_enabled | initial 1 |
| 06:45 | sw_fog_closes_vent | initial 1 |
| 06:45 | sw_mister_closes_vent | initial 0 |
| 06:45 | sw_summer_vent_enabled | initial 1 |
| 06:45 | temp_hysteresis | initial 2.14 |
| 06:45 | vent_exchange_fraction | initial 0.3 |
| 06:45 | vent_prefer_dp_delta_f | initial 9 |
| 06:45 | vent_prefer_temp_delta_f | initial 12 |
| 06:45 | vpd_watch_dwell_s | initial 75 |
| 09:00 | cold_vent_guard_delta_f | 15 → 14 |
| 09:00 | vent_prefer_temp_delta_f | 12 → 10 |
| 14:00 | dwell_gate_ms | 300000 → 285000 |
| 14:00 | mister_all_delay_s | 102 → 97.5 |
| 14:00 | mister_engage_delay_s | 51 → 48.75 |
| 14:00 | temp_hysteresis | 2.14 → 2.05 |
| 14:00 | vpd_watch_dwell_s | 75 → 71.25 |
| 16:30 | cold_vent_guard_delta_f | 14 → 15 |
| 16:30 | dwell_gate_ms | 285000 → 300000 |
| 16:30 | min_fog_off_s | 84 → 90 |
| 16:30 | min_fog_on_s | 54.75 → 52.5 |
| 16:30 | mister_all_delay_s | 97.5 → 102 |
| 16:30 | mister_engage_delay_s | 48.75 → 51 |
| 16:30 | temp_hysteresis | 2.05 → 2.14 |
| 16:30 | vent_prefer_temp_delta_f | 10 → 12 |
| 16:30 | vpd_watch_dwell_s | 71.25 → 75 |
| 18:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.1 |
| 18:00 | dwell_gate_ms | 300000 → 315000 |
| 18:00 | min_fog_off_s | 90 → 72 |
| 18:00 | min_fog_on_s | 52.5 → 59.25 |
| 18:00 | mister_all_delay_s | 102 → 106.5 |
| 18:00 | mister_engage_delay_s | 51 → 53.25 |
| 18:00 | temp_hysteresis | 2.14 → 2.23 |
| 18:00 | vent_prefer_dp_delta_f | 9 → 10 |
| 18:00 | vpd_watch_dwell_s | 75 → 78.75 |
☀️ Midday Cycle (10:58 AM) — iris-20261114-1055
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261114-0015
Previous hypothesis: Nov 13 scored 77.1 (contract-2 binary joint 60.1%, temp 98.3%, VPD 60.4%) with 9.5 nominal VPD-low hours and 0.2 dew-risk hours; costs unavailable. Iris-20261113-0645 was revised to 4/10 vs anchor 3 after 56/61 requested actions were held, so no causal lesson is claimed. For today’s 35F saturated pre-dawn and overcast, low-solar 51F day, expect cold heat demand but little outdoor drying. Avoid added moisture while measured VPD is below its high edge; retain bounded, dew-safe response if live VPD rises. Result: Scoped plan window was 0.243 day (~5.83 h): contract-2 binary joint/temp/VPD compliance 53.1%/95.5%/54.9%, nominal cold stress 0.26 h, VPD-high 0 h, VPD-low 2.61 h, dew-risk 0 h, planner score 77.9. This partly supports stable temperature and no observed VPD-high/dew-risk during the evaluated window, but VPD-low remained the dominant failure. The plan’s recovery bridge began with measured VPD above the desired high edge; the window score has no high stress, but consumed target confirmation and causal effect are unverified. Evening taper/reopen prediction was not assessed by this scoped window. Whole-day water was 165 gal but is not plan-attributable; resource costs unavailable, coverage unverified, and no physical crop outcome. No durable lesson claimed. Score: 4/10
Hypothesis
Testing: Continue modest dewpoint-selective daytime drying through the cold/cloudy-to-clear deviation; compare VPD-low/cold stress without changing crop bands or safety rails. Expected outcome: By midnight, no VPD-high or dew-risk hours; reduce nominal VPD-low stress below yesterday’s 9.5h while preserving temperature control. Keep the existing 100-gal cap; resource costs remain unverified.
Setpoints
Saturday November 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:55 | hyst 0.1375 | Clear-sky observation; VPD 0.20 above high with safe dew mar |
| 17:00 | hyst 0.1375 | Cold humid dusk; edge-only response and low duty limit VPD-l |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:55 | s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Clear-sky observation; VPD 0.20 above high with safe dew mar |
| 17:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cold humid dusk; edge-only response and low duty limit VPD-l |
Sunday November 15
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | hyst 0.1375 | Frost-risk dawn: preserve heating posture; no forecast-only |
| 12:00 | hyst 0.1375 | Sunday solar returns, but outdoor VPD stays below 0.9; retai |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 07:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Frost-risk dawn: preserve heating posture; no forecast-only |
| 12:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Sunday solar returns, but outdoor VPD stays below 0.9; retai |
Monday November 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Monday dry ramp starts; calibrated forecast is near the edge |
| 12:00 | hyst 0.1375 | Calibrated Monday VPD peak remains about 1.54; restore compl |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Monday dry ramp starts; calibrated forecast is near the edge |
| 12:00 | s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Calibrated Monday VPD peak remains about 1.54; restore compl |
Tuesday November 17
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | hyst 0.1375 | Beyond 48h forecast uncertainty: taper to measured-edge assi |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 09:00 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Beyond 48h forecast uncertainty: taper to measured-edge assi |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 10:55 | band_track_fraction | initial 0 |
| 10:55 | cold_vent_guard_delta_f | initial 14 |
| 10:55 | cool_stage2_exit_hysteresis_f | initial 1 |
| 10:55 | direct_wet_stress_min_dew_margin_f | initial 10 |
| 10:55 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 10:55 | dwell_gate_ms | initial 210000 |
| 10:55 | enthalpy_close | initial 1 |
| 10:55 | enthalpy_open | initial -2 |
| 10:55 | fog_escalation_kpa | initial 0.2 |
| 10:55 | heat_hysteresis | initial 1 |
| 10:55 | min_fog_off_s | initial 54 |
| 10:55 | min_fog_on_s | initial 66 |
| 10:55 | mist_backoff_s | initial 600 |
| 10:55 | mist_max_closed_vent_s | initial 600 |
| 10:55 | mist_thermal_relief_s | initial 90 |
| 10:55 | mister_all_delay_s | initial 75 |
| 10:55 | mister_engage_delay_s | initial 37.5 |
| 10:55 | mister_water_budget_gal | initial 120 |
| 10:55 | night_vpd_bias_kpa | initial 0 |
| 10:55 | outdoor_staleness_max_s | initial 600 |
| 10:55 | sw_dwell_gate_enabled | initial 1 |
| 10:55 | sw_fog_closes_vent | initial 1 |
| 10:55 | sw_mister_closes_vent | initial 0 |
| 10:55 | sw_summer_vent_enabled | initial 1 |
| 10:55 | temp_hysteresis | initial 1.6 |
| 10:55 | vent_exchange_fraction | initial 0.3 |
| 10:55 | vent_prefer_dp_delta_f | initial 9 |
| 10:55 | vent_prefer_temp_delta_f | initial 10 |
| 10:55 | vpd_watch_dwell_s | initial 52.5 |
| 17:00 | min_fog_off_s | 54 → 72 |
| 17:00 | min_fog_on_s | 66 → 59.25 |
| 12:00 | min_fog_off_s | 72 → 54 |
| 12:00 | min_fog_on_s | 59.25 → 66 |
| 09:00 | min_fog_off_s | 54 → 72 |
| 09:00 | min_fog_on_s | 66 → 59.25 |
🌆 Evening Cycle (4:48 PM) — iris-20261114-1645
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261114-0645
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:52.0,“outdoor_rh_min_pct”:60.0,“solar_peak_w_m2”:309,“cloud_cover_avg_pct”:70,“notes”:“Nov 13 scorecard: contract-2 planner score 77.0; binary temp/VPD 98.3%/60.4%, 9.5 nominal VPD-low h, 0 VPD-high, 0.2 dew-risk h; costs unavailable, water 33 gal vs 37-gal 7d average. Current indoor 64F/VPD 0.82, dew margin 14.3F. Today forecast 35-52F, mostly cloudy, outdoor VPD peak 0.52. Prior sunset self-grade revised to 3/10 vs anchor 1 after 349/409 guardrail actions were held; weak attribution.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-14T06:45:00-07:00”,“end”:“2026-11-14T17:00:00-07:00”,“severity”:“medium”,“mitigation”:“No forecast-only wetting; keep band-edge mist available only on live VPD excess and safe dew margin; use selective drying exchange… Result: Scoped completed window 2026-11-14 16:48 to 2026-11-15 00:18 MST (0.313 day): contract-2 planner score 66.5; binary joint/temp/VPD compliance 23.6%/92.5%/24.9%; nominal cold stress 0.16h, VPD-high 0h, VPD-low 1.61h, dew-risk 0h. The predicted VPD-low/cold risk was directionally present but this window captures only the early part of the predicted overnight trough; its <2h VPD-low and zero dew-risk goals were met in this partial window, while joint/VPD performance remained poor. Forecast conditions diverged substantially: predicted outdoor high 45F/RH minimum 78%/solar 0 versus actual 49.6F/56%/384 W/m2. Realized dry-out read: 26 episodes, 13 ineffective and 13 insufficient-evidence, 0 effective; safety gates passed, but observed AH often rose and wet relay duty was zero. Costs unavailable, coverage unverified, targets not confirmed consumed, and no physical crop outcome; no causal benefit or durable lesson established. Score: 4/10
Hypothesis
Testing: Overnight humidity taper while retaining band-edge mister eligibility if measured VPD stays high. Expected outcome: By pre-dawn, keep dew-risk at 0h and avoid heavy fog; limit additional VPD-low stress to under 2h and cold stress to under 1h if heating capacity permits. Costs and physical crop outcomes are unavailable.
Conditions
45.0°F
78.0%
0.0 W/m²
96.0%
Sunset indoor 73.1F/VPD 0.93 kPa vs 0.90 high edge; dew margin 11.7F. Today’s score 76.9, binary temp/VPD 96.0/65.8%, VPD-low stress 5.67h; costs unavailable. The 12h forecast reaches 38F/95% RH/0.04 kPa at 03:00. Main risk is a humid low-VPD trough; preserve stable heat and dew safety, but retain bounded band-edge wet assist if measured VPD remains high. Historical temperature forecasts run about 2.3F cold.
Expected stress windows
Reduce mist duty and heavy fog as VPD falls; retain bounded band-edge mist only if live VPD remains high and dew margin is safe.
Preserve stable heating, require meaningful outdoor advantage before exchange, and penalize ordinary relay churn.
Parameter rationale
Defer heavy fog during the saturated trough while keeping band-edge mister eligibility; target zero dew-risk hours and under 2h additional VPD-low overnight.
Setpoints
Saturday November 14
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:45 | hyst 0.20550000000000002 | evening_settle: retain band-edge wet assist through recovery |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:45 | s2 1.86; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 30; wt 1.6333333333333333 | evening_settle: retain band-edge wet assist through recovery |
Sunday November 15
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.21050000000000002 | midnight_posture: humid trough expected; keep modest band-co |
| 05:30 | hyst 0.21050000000000002 | pre_dawn: limit unnecessary moisture while retaining a bound |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.905; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 41.25; wt 1.5133333333333332 | midnight_posture: humid trough expected; keep modest band-co |
| 05:30 | s2 1.92; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 45; wt 1.4666666666666666 | pre_dawn: limit unnecessary moisture while retaining a bound |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:45 | band_track_fraction | initial 0 |
| 16:45 | cold_vent_guard_delta_f | initial 14 |
| 16:45 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:45 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 16:45 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:45 | dwell_gate_ms | initial 300000 |
| 16:45 | enthalpy_close | initial 1 |
| 16:45 | enthalpy_open | initial -2 |
| 16:45 | fog_escalation_kpa | initial 0.3 |
| 16:45 | heat_hysteresis | initial 1 |
| 16:45 | min_fog_off_s | initial 54 |
| 16:45 | min_fog_on_s | initial 66 |
| 16:45 | mist_backoff_s | initial 600 |
| 16:45 | mist_max_closed_vent_s | initial 600 |
| 16:45 | mist_thermal_relief_s | initial 90 |
| 16:45 | mister_all_delay_s | initial 102 |
| 16:45 | mister_engage_delay_s | initial 51 |
| 16:45 | mister_water_budget_gal | initial 120 |
| 16:45 | night_vpd_bias_kpa | initial 0 |
| 16:45 | outdoor_staleness_max_s | initial 600 |
| 16:45 | sw_dwell_gate_enabled | initial 1 |
| 16:45 | sw_fog_closes_vent | initial 1 |
| 16:45 | sw_mister_closes_vent | initial 0 |
| 16:45 | sw_summer_vent_enabled | initial 1 |
| 16:45 | temp_hysteresis | initial 2.14 |
| 16:45 | vent_exchange_fraction | initial 0.3 |
| 16:45 | vent_prefer_dp_delta_f | initial 9 |
| 16:45 | vent_prefer_temp_delta_f | initial 10 |
| 16:45 | vpd_watch_dwell_s | initial 75 |
| 00:00 | direct_wet_stress_min_dew_margin_f | 8 → 10 |
| 00:00 | dwell_gate_ms | 300000 → 315000 |
| 00:00 | fog_escalation_kpa | 0.3 → 0.4 |
| 00:00 | min_fog_off_s | 54 → 72 |
| 00:00 | min_fog_on_s | 66 → 59.25 |
| 00:00 | mister_all_delay_s | 102 → 106.5 |
| 00:00 | mister_engage_delay_s | 51 → 53.25 |
| 00:00 | temp_hysteresis | 2.14 → 2.23 |
| 00:00 | vpd_watch_dwell_s | 75 → 78.75 |
| 05:30 | min_fog_off_s | 72 → 78 |
| 05:30 | min_fog_on_s | 59.25 → 57 |
End-of-Day Summary
Climate
59.1–79.2°F; avg 68.0°F
0.36–1.35 kPa; avg 0.81 kPa
56.0–84.3%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
par_quantum_sensor_canopy - Validity:
dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (above the served band): 0.0h
- VPD stress (above the served band): 0.0h
- Cold stress (below the served band): 1.1h
Economics
USD 5.65
USD 2.75
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 30 min | Primary exhaust runtime. |
| Fan 2 | 25 min | Secondary exhaust runtime. |
| Vent | 49 min | Intake vent runtime. |
| Fog | 4 min | Fogger runtime. |
| Heat 1 electric | 1250 min | Electric heater runtime. |
| Heat 2 gas | 265 min | Gas heater runtime. |
| Grow lights | 1719 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Vanda Orchids | center | 78% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Plants appear healthy with green foliage; no visible wilting or discoloration. Roots visible in hanging baskets look turgid. || Plants appear healthy with lush green foliage and visible root systems. No signs of stress or disease. || Plants appear healthy with no visible signs of stress. Roots are visible and appear normal. || Plants appear turgid with healthy leaf structure; no visible wilting or discoloration. Root systems visible and intact.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 73.5°F | 1.02 kPa | 64.0% |
| 11:00 | 75.6°F | 1.15 kPa | 61.8% |
| 12:00 | 75.7°F | 1.17 kPa | 61.4% |
| 13:00 | 76.4°F | 1.21 kPa | 60.9% |
| 14:00 | 78.6°F | 1.14 kPa | 66.0% |
| 15:00 | 77.2°F | 1.05 kPa | 67.1% |
| 16:00 | 73.5°F | 0.88 kPa | 68.7% |
| 17:00 | 72.2°F | 0.89 kPa | 67.2% |
| 18:00 | 70.7°F | 0.89 kPa | 65.1% |
| 19:00 | 69.0°F | 0.90 kPa | 62.7% |
| 20:00 | 67.4°F | 0.87 kPa | 61.9% |
| 21:00 | 65.7°F | 0.83 kPa | 61.6% |
| 22:00 | 62.8°F | 0.65 kPa | 66.9% |
| 23:00 | 61.2°F | 0.61 kPa | 67.2% |
| 00:00 | 61.4°F | 0.69 kPa | 62.7% |
| 01:00 | 60.6°F | 0.66 kPa | 63.8% |
| 02:00 | 60.4°F | 0.67 kPa | 63.1% |
| 03:00 | 60.4°F | 0.68 kPa | 62.2% |
| 04:00 | 61.0°F | 0.74 kPa | 59.8% |
| 05:00 | 63.1°F | 0.79 kPa | 60.0% |
| 06:00 | 63.5°F | 0.77 kPa | 61.7% |
| 07:00 | 66.1°F | 0.52 kPa | 76.3% |
| 08:00 | 67.6°F | 0.72 kPa | 68.9% |
| 09:00 | 70.7°F | 0.91 kPa | 64.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-11-08 | 0.0h | 0.2h | 0.7h |
| 2026-11-09 | 0.0h | 0.1h | 0.5h |
| 2026-11-10 | 0.0h | 0.1h | 0.8h |
| 2026-11-11 | 0.0h | 0.0h | 0.3h |
| 2026-11-12 | 0.0h | 0.1h | 0.4h |
| 2026-11-13 | 0.0h | 0.0h | 0.4h |
| 2026-11-14 | 0.0h | 0.0h | 1.1h |