November 15, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

7

Plan writes

4

No-change acknowledgements

2

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:16MIDNIGHTplan_writtenWrote public plan iris-20261115-0016. Resolved 00:18 MDT.
Morning planning cycle06:47SUNRISEplan_writtenWrote public plan iris-20261115-0647. Resolved 06:51 MDT.
Forecast deviation10:43FORECAST_DEVIATIONplan_writtenWrote public plan iris-20261115-1043. Resolved 10:47 MDT.
Solar peak planning checkpoint11:45SOLAR_MAXaction_completedDelivery recorded without a public plan write. Resolved 11:47 MDT.
Peak Stress13:45TRANSITIONackedAcknowledged: No tunable change warranted: fresh climate is 77.6°F, VPD 1.09 kPa, dew margin 12°F, mode IDLE; heat1 alone is on. No current heat or VPD-high stress, and the active staged-wet plan is appropriate as outdoor conditions cool and VPD falls this evening. Resolved 13:46 MDT.
Decline15:44TRANSITIONackedAcknowledged: No immediate retune: house temp 80.8°F and VPD 1.19 kPa are within the current served bands, dew margin is 11.7°F, and all climate relays are off. The existing 16:30 waypoint already tapers mister thresholds and widens the pulse gap ahead of the cold, humid overnight forecast; localized south/east VPD outliers do not justify overriding that staged posture. Resolved 15:45 MDT.
Evening planning cycle16:43SUNSETplan_writtenWrote public plan iris-20261115-1643. Resolved 16:47 MDT.

🌅 Morning Cycle (12:18 AM) — iris-20261115-0016

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261114-1645

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:45,“outdoor_rh_min_pct”:78,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:96,“notes”:“Sunset indoor 73.1F/VPD 0.93 kPa vs 0.90 high edge; dew margin 11.7F. Today’s score 76.9, binary temp/VPD 96.0/65.8%, VPD-low stress 5.67h; costs unavailable. The 12h forecast reaches 38F/95% RH/0.04 kPa at 03:00. Main risk is a humid low-VPD trough; preserve stable heat and dew safety, but retain bounded band-edge wet assist if measured VPD remains high. Historical temperature forecasts run about 2.3F cold.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-14T22:00:00-07:00”,“end”:“2026-11-15T05:30:00-07:00”,“severity”:“high”,“mitigation”:“Reduce mist duty and heavy fog as VPD falls; retain bounded band-edge mist only if live VPD remains high and dew margin is safe… Result: Scoped window 0.273 day for iris-20261115-0016: contract-2 planner score 73.6; binary joint/temp/VPD compliance 30.7%/89.8%/34.6%; nominal cold stress 0.29h, VPD-high 0.05h, VPD-low 1.84h, dew-risk 0h. The <2h VPD-low and zero dew-risk goals were met, but joint/VPD compliance remained poor and cold stress was nonzero. Costs, coverage, confirmed consumed targets and physical crop outcomes are unavailable; this supports only a cautious partial score, not causal benefit or a durable lesson. Score: 4/10

Hypothesis

Expected outcome: Through the early-day handoff, maintain zero dew-risk hours and under 1h cold stress if heating capacity permits; avoid forecast-only wetting while keeping assist available near live VPD-high demand. Costs and physical crop outcomes are unavailable.

Setpoints

Sunday November 15

Primary crop-band changes:

TimeValuesNote
00:16hyst 0.25625000000000003Cold, humid night: restrain wetting but retain band-edge res
03:30hyst 0.26125000000000004Frost-risk pre-dawn: preserve heat, minimize wet duty and co
06:30hyst 0.25125000000000003At sunrise, keep dawn moisture conservative until live VPD a
09:30hyst 0.24125000000000002Early-day handoff: reopen modest band-coupled assist only wi

Tactical tunable changes:

TimeValuesNote
00:16s2 1.995; cool_exit 2.14; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 60; wt 1.3Cold, humid night: restrain wetting but retain band-edge res
03:30s2 2.0100000000000002; cool_exit 2.23; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 60; wt 1.2333333333333334Frost-risk pre-dawn: preserve heat, minimize wet duty and co
06:30s2 1.98; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 60; wt 1.3333333333333333At sunrise, keep dawn moisture conservative until live VPD a
09:30s2 1.905; cool_exit 1.87; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 41.25; wt 1.5666666666666669Early-day handoff: reopen modest band-coupled assist only wi

Changed secondary parameters:

TimeParameterChange
00:16band_track_fractioninitial 0
00:16cold_vent_guard_delta_finitial 14
00:16cool_stage2_exit_hysteresis_finitial 1
00:16direct_wet_stress_min_dew_margin_finitial 8
00:16direct_wet_stress_vpd_margin_kpainitial 0.05
00:16dwell_gate_msinitial 300000
00:16enthalpy_closeinitial 1
00:16enthalpy_openinitial -2
00:16fog_escalation_kpainitial 0.4
00:16heat_hysteresisinitial 1
00:16min_fog_off_sinitial 108
00:16min_fog_on_sinitial 45.75
00:16mist_backoff_sinitial 600
00:16mist_max_closed_vent_sinitial 600
00:16mist_thermal_relief_sinitial 90
00:16mister_all_delay_sinitial 102
00:16mister_engage_delay_sinitial 51
00:16mister_water_budget_galinitial 120
00:16night_vpd_bias_kpainitial 0
00:16outdoor_staleness_max_sinitial 600
00:16sw_dwell_gate_enabledinitial 1
00:16sw_fog_closes_ventinitial 1
00:16sw_mister_closes_ventinitial 0
00:16sw_summer_vent_enabledinitial 1
00:16temp_hysteresisinitial 2.14
00:16vent_exchange_fractioninitial 0.3
00:16vent_prefer_dp_delta_finitial 9
00:16vent_prefer_temp_delta_finitial 10
00:16vpd_watch_dwell_sinitial 75
03:30dwell_gate_ms300000 → 315000
03:30fog_escalation_kpa0.4 → 0.5
03:30min_fog_off_s108 → 114
03:30min_fog_on_s45.75 → 43.5
03:30mister_all_delay_s102 → 106.5
03:30mister_engage_delay_s51 → 53.25
03:30temp_hysteresis2.14 → 2.23
03:30vpd_watch_dwell_s75 → 78.75
06:30dwell_gate_ms315000 → 285000
06:30fog_escalation_kpa0.5 → 0.4
06:30min_fog_off_s114 → 102
06:30min_fog_on_s43.5 → 48
06:30mister_all_delay_s106.5 → 97.5
06:30mister_engage_delay_s53.25 → 48.75
06:30temp_hysteresis2.23 → 2.05
06:30vpd_watch_dwell_s78.75 → 71.25
09:30dwell_gate_ms285000 → 255000
09:30fog_escalation_kpa0.4 → 0.3
09:30min_fog_off_s102 → 72
09:30min_fog_on_s48 → 59.25
09:30mister_all_delay_s97.5 → 88.5
09:30mister_engage_delay_s48.75 → 44.25
09:30temp_hysteresis2.05 → 1.87
09:30vpd_watch_dwell_s71.25 → 63.75

🌅 Morning Cycle (6:51 AM) — iris-20261115-0647

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261114-1645

Result: Scoped only to iris-20261115-0647’s governed 06:51–10:47 MST window (0.164 day): contract-3 binary served-band compliance/planner_score 54.8%, temp 92.5%, VPD 58.3%; stress cold 0.20h, VPD-high 0.03h, VPD-low 1.11h, dew-risk 0h in the scoped scorecard. This directionally matches the forecasted humid-dawn VPD-low risk and conservative wet posture, but the joint/VPD score remained poor; the planned midday live-edge phase was outside this plan’s window. No causal benefit can be claimed: coverage and consumed targets are unverified, resource metrics are unavailable, and no physical crop outcome is qualified. Score: 4/10

Hypothesis

Testing: Test staged wet authority: 10% mist duty through humid morning, then 18% only for live midday edge demand, with conservative fog; measure VPD-low/high, dew risk and guardrail/readback realization. Expected outcome: For 06:46-18:30, target <3h VPD-low stress, zero dew-risk hours and >=90% temp compliance; compare VPD axis and action/guardrail evidence without claiming crop benefit or causality.

Conditions

Outdoor peak

58.0°F

RH minimum

47.0%

Solar peak

459.0 W/m²

Cloud average

30.0%

Cool high-RH dawn, clouds clear under modest solar, then a cold night. Indoor 63F/VPD 0.84/dew margin 15.2F; South VPD 1.07 versus West 0.71. Yesterday VPD-low stress was 10.75h; costs unavailable. I scored the prior plan 4 vs anchor 1 because its partial-window <2h VPD-low and zero dew-risk goals held, but poor VPD/joint compliance and 70/96 held guardrails weakened attribution.

Expected stress windows

vpd_lowmedium · 2026-11-15T06:46:00-07:00 to 2026-11-15T11:00:00-07:00

Keep humid-dawn mist duty low and fog conservative; allow only controller-selected, dew-safe drying and verify live VPD.

coldhigh · 2026-11-16T02:00:00-07:00 to 2026-11-16T06:30:00-07:00

Retain low-wet, stable evening posture; verify heating and protect the lower edge through the 33F forecast.

Parameter rationale

mister_engage_kpa0.95 → 1.0; At dawn house VPD is 0.84 below the 0.90 high edge, while yesterday had 10.75h nominal VPD-low stress; South is the dry outlier at 1.07.

Stage a modest +0.10-kPa dawn excess with a 10% duty cap, then +0.05 and 18% only at midday, limiting broad wetting while preserving live edge response.

Setpoints

Sunday November 15

Primary crop-band changes:

TimeValuesNote
06:46hyst 0.21125000000000002Dawn: avoid forecast-only wetting; retain dew-safe, controll
09:30hyst 0.21125000000000002Morning ramp: hold modest wet duty until live VPD justifies
13:30hyst 0.21125000000000002Peak: permit band-edge assist for South/local demand, capped
16:30hyst 0.21125000000000002Decline: taper broad wet authority as solar falls; retain ed
18:30hyst 0.22125Evening: low-wet and churn-conscious for the cold, low-outdo

Tactical tunable changes:

TimeValuesNote
06:46s2 1.9300000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1; all 1.1; pulse 30; gap 56.25; wt 1.3666666666666667Dawn: avoid forecast-only wetting; retain dew-safe, controll
09:30s2 1.8775000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1; all 1.1; pulse 30; gap 56.25; wt 1.3666666666666667Morning ramp: hold modest wet duty until live VPD justifies
13:30s2 1.8475000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 48.75; wt 1.4866666666666666Peak: permit band-edge assist for South/local demand, capped
16:30s2 1.965; cool_exit 2.05; all_fans 0; dw_stress 0; engage 1; all 1.15; pulse 30; gap 56.25; wt 1.3666666666666667Decline: taper broad wet authority as solar falls; retain ed
18:30s2 1.995; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1; all 1.15; pulse 30; gap 60; wt 1.2866666666666666Evening: low-wet and churn-conscious for the cold, low-outdo

Changed secondary parameters:

TimeParameterChange
06:46band_track_fractioninitial 0
06:46cold_vent_guard_delta_finitial 14
06:46cool_stage2_exit_hysteresis_finitial 1
06:46direct_wet_stress_min_dew_margin_finitial 9
06:46direct_wet_stress_vpd_margin_kpainitial 0.1
06:46dwell_gate_msinitial 285000
06:46enthalpy_closeinitial 1
06:46enthalpy_openinitial -2
06:46fog_escalation_kpainitial 0.4
06:46heat_hysteresisinitial 1
06:46min_fog_off_sinitial 96
06:46min_fog_on_sinitial 50.25
06:46mist_backoff_sinitial 600
06:46mist_max_closed_vent_sinitial 600
06:46mist_thermal_relief_sinitial 90
06:46mister_all_delay_sinitial 97.5
06:46mister_engage_delay_sinitial 48.75
06:46mister_water_budget_galinitial 120
06:46night_vpd_bias_kpainitial 0
06:46outdoor_staleness_max_sinitial 600
06:46sw_dwell_gate_enabledinitial 1
06:46sw_fog_closes_ventinitial 1
06:46sw_mister_closes_ventinitial 0
06:46sw_summer_vent_enabledinitial 1
06:46temp_hysteresisinitial 2.05
06:46vent_exchange_fractioninitial 0.3
06:46vent_prefer_dp_delta_finitial 9
06:46vent_prefer_temp_delta_finitial 10
06:46vpd_watch_dwell_sinitial 71.25
13:30direct_wet_stress_min_dew_margin_f9 → 8
13:30direct_wet_stress_vpd_margin_kpa0.1 → 0.05
13:30fog_escalation_kpa0.4 → 0.35
13:30min_fog_off_s96 → 84
13:30min_fog_on_s50.25 → 54.75
16:30direct_wet_stress_min_dew_margin_f8 → 9
16:30direct_wet_stress_vpd_margin_kpa0.05 → 0.1
16:30fog_escalation_kpa0.35 → 0.4
16:30min_fog_off_s84 → 96
16:30min_fog_on_s54.75 → 50.25
18:30direct_wet_stress_min_dew_margin_f9 → 10
18:30dwell_gate_ms285000 → 315000
18:30min_fog_off_s96 → 108
18:30min_fog_on_s50.25 → 45.75
18:30mister_all_delay_s97.5 → 106.5
18:30mister_engage_delay_s48.75 → 53.25
18:30temp_hysteresis2.05 → 2.23
18:30vpd_watch_dwell_s71.25 → 78.75

☀️ Midday Cycle (10:47 AM) — iris-20261115-1043

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261115-0016

Previous hypothesis: Nov 14 contract-2 daily planner score was 78.2 (joint 54.1%, temp 95.4%, VPD 55.9%); nominal VPD-low stress 10.33h and cold 1.08h, with resource costs unavailable. Evaluated iris-20261114-1055 at 4/10 vs anchor 5: its 5.83h scoped window scored 77.9, VPD-low 2.61h, cold 0.26h, and no VPD-high/dew-risk; recovery was only partly supported and no durable lesson is justified. Current indoor state is 60.6F, VPD 0.41, dew margin 7.1F with heat1 on. Keep cold-night restraint, avoid chasing the target inside the corridor, and preserve bounded wet assist for a measured rise toward the current VPD high edge. Forecast is stale; an open band-drift alert cites a conflicting older band, so favor fresh climate/action evidence. Result: Scoped 6.0h plan window (2026-11-15 10:47–16:47 MST): contract-3 planner score/joint served-band compliance 54.5%, temp-axis 93.8%, VPD-axis 57.3%; the supplied window row reports no heat stress, ~0.37h cold, ~0.04h VPD-high, and ~2.52h VPD-low. The hypothesis called for carrying the staged wet cap/live-edge gating through the daytime solar deviation and then tapering toward the cold humid night. Temperature stayed strong, but VPD/joint compliance remained weak and low-VPD exposure was not eliminated; no evidence establishes that the wet-cap treatment caused or prevented these outcomes. The forecast solar deviation was real; the scoped window does not establish a repeatable forecast bias. Full-day Nov 15 scorecard (54.1%, temp 93.6%, VPD 56.9%, VPD-low 10.0h, cold 1.5h, dew-risk 0h) is context only, not substituted for the window grade. Coverage/consumed targets and physical crop outcome are unverified; no durable lesson extracted. Score: 4/10

Hypothesis

Testing: Continue the staged wet-authority trial: 10% mist duty through humid morning, then 18% only for live midday edge demand, with conservative fog; measure VPD-low/high, dew risk and guardrail/readback realization. No new treatment claim. Expected outcome: Preserve dew margin >=8°F through the cold night; keep the Sunday 18% wet cap live-edge-only, then taper when measured VPD recovers. Maintain frost-safe posture Monday; enable bounded Tue/Wed dry-ramp response only on live edge evidence, evaluating scoped stress and guardrail holds without claiming crop causality.

Setpoints

Sunday November 15

Primary crop-band changes:

TimeValuesNote
10:30hyst 0.1375Bright clearing and slight dual-axis edge; preserve live-edg
16:30hyst 0.1375Taper trial cap at sunset only as VPD recovers; maintain sma
19:00hyst 0.1375Cold humid night ahead; minimize wetting, preserve heat and

Tactical tunable changes:

TimeValuesNote
10:30s2 1.503; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7Bright clearing and slight dual-axis edge; preserve live-edg
16:30s2 1.6735000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Taper trial cap at sunset only as VPD recovers; maintain sma
19:00s2 1.7610000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Cold humid night ahead; minimize wetting, preserve heat and

Monday November 16

Primary crop-band changes:

TimeValuesNote
05:30hyst 0.1375Protect through forecast 33°F frost; keep wet assist narrow
11:30hyst 0.1375Cloudy mild day; keep live-edge authority, avoid additional

Tactical tunable changes:

TimeValuesNote
05:30s2 1.7610000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Protect through forecast 33°F frost; keep wet assist narrow
11:30s2 1.6005; cool_exit 1.6; all_fans 1; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Cloudy mild day; keep live-edge authority, avoid additional

Tuesday November 17

Primary crop-band changes:

TimeValuesNote
10:30hyst 0.1375Forecast supports dry sunny ramp even after 48h+ VPD correct
16:30hyst 0.1375Taper after the dry ramp only with observed recovery; retain

Tactical tunable changes:

TimeValuesNote
10:30s2 1.5975000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002Forecast supports dry sunny ramp even after 48h+ VPD correct
16:30s2 1.8175000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Taper after the dry ramp only with observed recovery; retain

Wednesday November 18

Primary crop-band changes:

TimeValuesNote
10:00hyst 0.1375Third-day solar/VPD rise; keep bounded live-edge moisture re

Tactical tunable changes:

TimeValuesNote
10:00s2 1.7875; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 33.75; wt 1.7Third-day solar/VPD rise; keep bounded live-edge moisture re

Changed secondary parameters:

TimeParameterChange
10:30band_track_fractioninitial 0
10:30cold_vent_guard_delta_finitial 14
10:30cool_stage2_exit_hysteresis_finitial 1
10:30direct_wet_stress_min_dew_margin_finitial 8
10:30direct_wet_stress_vpd_margin_kpainitial 0.05
10:30dwell_gate_msinitial 210000
10:30enthalpy_closeinitial 1
10:30enthalpy_openinitial -2
10:30fog_escalation_kpainitial 0.2
10:30heat_hysteresisinitial 1
10:30min_fog_off_sinitial 60
10:30min_fog_on_sinitial 63.75
10:30mist_backoff_sinitial 600
10:30mist_max_closed_vent_sinitial 600
10:30mist_thermal_relief_sinitial 90
10:30mister_all_delay_sinitial 75
10:30mister_engage_delay_sinitial 37.5
10:30mister_water_budget_galinitial 120
10:30night_vpd_bias_kpainitial 0
10:30outdoor_staleness_max_sinitial 600
10:30sw_dwell_gate_enabledinitial 1
10:30sw_fog_closes_ventinitial 1
10:30sw_mister_closes_ventinitial 0
10:30sw_summer_vent_enabledinitial 1
10:30temp_hysteresisinitial 1.6
10:30vent_exchange_fractioninitial 0.3
10:30vent_prefer_dp_delta_finitial 9
10:30vent_prefer_temp_delta_finitial 10
10:30vpd_watch_dwell_sinitial 52.5
16:30min_fog_off_s60 → 72
16:30min_fog_on_s63.75 → 59.25
19:00cold_vent_guard_delta_f14 → 15
19:00direct_wet_stress_min_dew_margin_f8 → 9
19:00vent_prefer_dp_delta_f9 → 10
19:00vent_prefer_temp_delta_f10 → 12
11:30cold_vent_guard_delta_f15 → 14
11:30direct_wet_stress_min_dew_margin_f9 → 8
11:30vent_prefer_dp_delta_f10 → 9
11:30vent_prefer_temp_delta_f12 → 10
10:30min_fog_off_s72 → 54
10:30min_fog_on_s59.25 → 66
16:30min_fog_off_s54 → 72
16:30min_fog_on_s66 → 59.25
10:00min_fog_off_s72 → 60
10:00min_fog_on_s59.25 → 63.75

🌆 Evening Cycle (4:47 PM) — iris-20261115-1643

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261115-0647

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:58.0,“outdoor_rh_min_pct”:47.0,“solar_peak_w_m2”:459,“cloud_cover_avg_pct”:30.0,“notes”:“Cool high-RH dawn, clouds clear under modest solar, then a cold night. Indoor 63F/VPD 0.84/dew margin 15.2F; South VPD 1.07 versus West 0.71. Yesterday VPD-low stress was 10.75h; costs unavailable. I scored the prior plan 4 vs anchor 1 because its partial-window <2h VPD-low and zero dew-risk goals held, but poor VPD/joint compliance and 70/96 held guardrails weakened attribution.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-15T06:46:00-07:00”,“end”:“2026-11-15T11:00:00-07:00”,“severity”:“medium”,“mitigation”:“Keep humid-dawn mist duty low and fog conservative; allow only controller-selected, dew-safe drying and verify live VPD… Result: Scoped outcome for iris-20261115-1643 only: its governed window was about 7.5 h (16:47–00:16 MST), with contract-3 served-band compliance 63.0%, temp 89.6%, VPD 63.0%; cold stress 0.06 h, VPD-high 0, VPD-low 0.26 h, dew-risk 0.06 h. The predicted VPD-low window was only partly observed; the cold window began after this plan was superseded by iris-20261116-0016. Forecast conditions were materially wrong (outdoor peak 56.1F vs 49F, solar 570 vs 0 W/m2, RH minimum 45% vs 71%). Low stress in the short observed window is not evidence the gap/hysteresis changes caused improvement; coverage, consumed targets, and crop outcomes are unverified. No durable lesson. Score: 4/10

Hypothesis

Testing: Carry forward the staged wet-authority trial: 10% duty cap during humid dawn, only for live-edge demand; no new treatment claim. Expected outcome: By dawn, keep dew margin at or above 8F, cold stress below 1.5h, and avoid additional VPD-low stress from wet assist; retain heat stability and the 10% live-edge cap. Judge only scoped band and guardrail evidence.

Conditions

Outdoor peak

49.0°F

RH minimum

71.0%

Solar peak

0.0 W/m²

Cloud average

35.667%

Forecast falls to 35F with RH 93-100% and outdoor VPD 0-0.05 before dawn; indoor is 72.9F, VPD 0.80, dew margin 9.8F. Today’s partial VPD-low stress dominates. Prior iris-20261115-0016 self-grade 4 vs anchor 1 over-credited a short window despite weak joint/VPD and many held guardrails; keep attribution cautious.

Expected stress windows

vpd_lowhigh · 2026-11-15T20:00:00-07:00 to 2026-11-16T09:00:00-07:00

Keep wet assist capped at 10%, live-edge-only; avoid unnecessary mist/fog through the saturated trough.

coldhigh · 2026-11-16T00:00:00-07:00 to 2026-11-16T07:00:00-07:00

Protect heat hold with conservative outdoor exchange and anti-churn posture; retain all safety preemption.

Parameter rationale

mister_pulse_gap_s41.25 → 50.0; Outdoor RH reaches 93-100%, VPD 0-0.05; today's partial VPD-low stress is 6.75h.

Limit added humidification during the trough while retaining bounded response to measured VPD-high demand.

temp_hysteresis1.6 → 2.0; 35F pre-dawn low and 86 heat1 state transitions in the prior 24h.

Reduce ordinary heat/vent reversals and keep cold stress below 1.5h without delaying safety action.

Setpoints

Sunday November 15

Primary crop-band changes:

TimeValuesNote
16:44hyst 0.20550000000000002evening_settle: preserve heat; low wet cap and selective exc

Tactical tunable changes:

TimeValuesNote
16:44s2 1.7725000000000002; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.1; all 1.3; pulse 30; gap 30; wt 1.6evening_settle: preserve heat; low wet cap and selective exc

Monday November 16

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.20550000000000002midnight_posture: avoid wet overshoot and ordinary heat/vent
05:30hyst 0.20550000000000002pre_dawn: retain the capped live-edge bridge; let fresh indo

Tactical tunable changes:

TimeValuesNote
00:00s2 1.86; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.15; all 1.35; pulse 30; gap 30; wt 1.6midnight_posture: avoid wet overshoot and ordinary heat/vent
05:30s2 1.86; cool_exit 2.14; all_fans 0; dw_stress 0; engage 1.05; all 1.2; pulse 30; gap 30; wt 1.6pre_dawn: retain the capped live-edge bridge; let fresh indo

Changed secondary parameters:

TimeParameterChange
16:44band_track_fractioninitial 0
16:44cold_vent_guard_delta_finitial 14
16:44cool_stage2_exit_hysteresis_finitial 1
16:44direct_wet_stress_min_dew_margin_finitial 8
16:44direct_wet_stress_vpd_margin_kpainitial 0.2
16:44dwell_gate_msinitial 300000
16:44enthalpy_closeinitial 1
16:44enthalpy_openinitial -2
16:44fog_escalation_kpainitial 0.45
16:44heat_hysteresisinitial 1
16:44min_fog_off_sinitial 54
16:44min_fog_on_sinitial 66
16:44mist_backoff_sinitial 600
16:44mist_max_closed_vent_sinitial 600
16:44mist_thermal_relief_sinitial 90
16:44mister_all_delay_sinitial 102
16:44mister_engage_delay_sinitial 51
16:44mister_water_budget_galinitial 120
16:44night_vpd_bias_kpainitial 0
16:44outdoor_staleness_max_sinitial 600
16:44sw_dwell_gate_enabledinitial 1
16:44sw_fog_closes_ventinitial 1
16:44sw_mister_closes_ventinitial 0
16:44sw_summer_vent_enabledinitial 1
16:44temp_hysteresisinitial 2.14
16:44vent_exchange_fractioninitial 0.3
16:44vent_prefer_dp_delta_finitial 9
16:44vent_prefer_temp_delta_finitial 10
16:44vpd_watch_dwell_sinitial 75
00:00direct_wet_stress_vpd_margin_kpa0.2 → 0.25
05:30direct_wet_stress_vpd_margin_kpa0.25 → 0.15
05:30fog_escalation_kpa0.45 → 0.35

End-of-Day Summary

Climate

Temperature

59.0–82.9°F; avg 68.5°F

VPD

0.36–1.45 kPa; avg 0.83 kPa

Relative humidity

45.2–79.8%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: par_quantum_sensor_canopy
  • Validity: dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (above the served band): 0.0h
  • VPD stress (above the served band): 0.2h
  • Cold stress (below the served band): 1.5h

Economics

Electric

USD 4.45

Gas

USD 2.59

Water

USD 0.220

Total

USD 7.26

Equipment Runtimes

EquipmentRuntimeReading
Fan 163 minPrimary exhaust runtime.
Fan 254 minSecondary exhaust runtime.
Vent101 minIntake vent runtime.
Fog9 minFogger runtime.
Heat 1 electric1057 minElectric heater runtime.
Heat 2 gas250 minGas heater runtime.
Grow lights1186 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center0.00hCenter mister runtime.

Water

  • Total: 47 gal
  • Mister: 8 gal

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Vanda Orchidscenter78%4Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
Vanda OrchidsGemini Vision notes

Plants appear healthy with green foliage and active root growth visible on hanging specimen. No obvious signs of stress. || Plants appear healthy with green foliage and active root systems visible in hanging baskets. No signs of stress or disease. || Plants appear healthy with green foliage; some aerial roots visible. No obvious wilting or discoloration. || Plants appear healthy with visible aerial roots; no obvious signs of stress or disease.

Hourly Pattern

HourTemperatureVPDRH
10:0073.0°F1.07 kPa61.5%
11:0074.6°F1.06 kPa63.6%
12:0076.1°F1.08 kPa65.0%
13:0076.5°F1.08 kPa65.5%
14:0076.7°F1.06 kPa66.1%
15:0075.6°F1.09 kPa64.2%
16:0074.3°F1.02 kPa65.0%
17:0073.3°F0.98 kPa65.5%
18:0070.8°F0.89 kPa65.9%
19:0070.0°F0.73 kPa70.8%
20:0067.6°F0.67 kPa71.2%
21:0064.2°F0.55 kPa73.4%
22:0062.8°F0.43 kPa78.3%
23:0062.3°F0.53 kPa72.6%
00:0060.4°F0.40 kPa77.5%
01:0060.7°F0.47 kPa74.4%
02:0060.4°F0.52 kPa71.1%
03:0060.8°F0.65 kPa64.7%
04:0061.5°F0.74 kPa61.1%
05:0062.2°F0.74 kPa61.9%
06:0064.0°F0.81 kPa61.0%
07:0066.7°F0.65 kPa71.5%
08:0068.9°F0.84 kPa66.0%
09:0069.7°F1.04 kPa58.5%

7-Day Stress Context

DateHeatVPD highCold
2026-11-090.0h0.1h0.5h
2026-11-100.0h0.1h0.8h
2026-11-110.0h0.0h0.3h
2026-11-120.0h0.1h0.4h
2026-11-130.0h0.0h0.4h
2026-11-140.0h0.0h1.1h
2026-11-150.0h0.2h1.5h