November 16, 2026

Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.

Planner Execution Ledger

Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.

Delivery events

10

Plan writes

3

No-change acknowledgements

2

Pending

0

EventDeliveredTypeStatusNote
End-of-day review and reset00:15MIDNIGHTplan_writtenWrote public plan iris-20261116-0016. Resolved 00:18 MDT.
Morning planning cycle06:48SUNRISEplan_writtenWrote public plan iris-20261116-0648. Resolved 06:52 MDT.
Solar peak planning checkpoint11:45SOLAR_MAXaction_completedDelivery recorded without a public plan write. Resolved 11:47 MDT.
Peak Stress13:46TRANSITIONackedAcknowledged: Peak checkpoint tracks the governing posture: indoor 75.1°F and VPD 1.17 kPa are within the served band, VPD-high stress is absent, and dew margin is 14.6°F. Current mode is IDLE; forecast turns colder and more humid, so no added wet aggression is warranted. Resolved 13:46 MDT.
Decline15:43TRANSITIONackedAcknowledged: Decline checkpoint is tracking the active plan: house is IDLE at 80.4°F / 1.07 kPa, within the served band, dew margin 10.5°F, and all wet/cooling relays are off. The forecast turns sharply colder and more humid overnight; existing evening waypoints already taper posture. No concrete signal warrants a one-shot tunable change; leaving the manually held fog setting untouched. Resolved 15:44 MDT.
Evening planning cycle16:43SUNSETdelivery_failedDelivery recorded without a public plan write.
Evening planning cycle16:44SUNSETdelivery_failedDelivery recorded without a public plan write.
Evening planning cycle16:45SUNSETdelivery_failedDelivery recorded without a public plan write.
Evening planning cycle16:46SUNSETdelivery_failedDelivery recorded without a public plan write.
Evening planning cycle16:47SUNSETplan_writtenWrote public plan iris-20261116-1648. Resolved 16:52 MDT.

🌅 Morning Cycle (12:18 AM) — iris-20261116-0016

Status

validated

Outcome score

4/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261115-1643

Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:49.0,“outdoor_rh_min_pct”:71.0,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:35.667,“notes”:“Forecast falls to 35F with RH 93-100% and outdoor VPD 0-0.05 before dawn; indoor is 72.9F, VPD 0.80, dew margin 9.8F. Today’s partial VPD-low stress dominates. Prior iris-20261115-0016 self-grade 4 vs anchor 1 over-credited a short window despite weak joint/VPD and many held guardrails; keep attribution cautious.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-15T20:00:00-07:00”,“end”:“2026-11-16T09:00:00-07:00”,“severity”:“high”,“mitigation”:“Keep wet assist capped at 10%, live-edge-only; avoid unnecessary mist/fog through the saturated trough… Result: Correction to the prior evaluation note: dry-out episode timestamps are UTC and must be converted to America/Denver. For iris-20261116-0016’s 00:18–02:06 MST window, 13 of 25 night episodes preceded the plan, 6 overlapped it, and 6 followed its 02:06 cutoff. The six overlapping episodes include four complete/ineffective and two incomplete/insufficient-evidence episodes; the full solar night totals 18 ineffective and 7 insufficient-evidence episodes, with safety gates passing. Relay truth during these short episodes showed vent/fans and heat1 active, wet relays off; the mixed, short-window evidence does not establish plan-caused dry-out effectiveness. The plan-scoped contract-3 score remains 72.2% over only 0.075 day: temp 86.1%, VPD 73.4%, cold 0.07h, VPD-low 0.13h, VPD-high 0h, dew-risk 0h. This ends before most of the planned humid-dawn/handoff interval. Guardrail audit recorded 65 VPD-high events, 45 held and 20 dispatched, further limiting attribution. No durable lesson extracted; coverage and crop outcomes remain unverified. Score: 4/10

Hypothesis

Testing: Continue the staged wet-authority trial: 10% duty cap during humid dawn, live-edge demand only; no new treatment claim. Expected outcome: Through humid dawn, preserve dew margin at or above 8°F and limit added wetting; at 11:00 reopen modest assist only on live VPD edge evidence. Judge by scoped served-band compliance and held-guardrail counts.

Setpoints

Monday November 16

Primary crop-band changes:

TimeValuesNote
00:16hyst 0.25125000000000003Frost and saturated air: preserve heat, cap wetting at 10% a
04:45hyst 0.25125000000000003Carry the humid-dawn live-edge cap through the coldest hours
08:30hyst 0.25125000000000003Keep wet authority bounded while outdoor air remains saturat
11:00hyst 0.24625000000000002Early-day handoff: modestly reopen band-coupled wet assist o

Tactical tunable changes:

TimeValuesNote
00:16s2 1.5925000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6Frost and saturated air: preserve heat, cap wetting at 10% a
04:45s2 1.5925000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6Carry the humid-dawn live-edge cap through the coldest hours
08:30s2 1.6561000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6Keep wet authority bounded while outdoor air remains saturat
11:00s2 1.6561000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 30; wt 1.6533333333333333Early-day handoff: modestly reopen band-coupled wet assist o

Changed secondary parameters:

TimeParameterChange
00:16band_track_fractioninitial 0
00:16cold_vent_guard_delta_finitial 14
00:16cool_stage2_exit_hysteresis_finitial 1
00:16direct_wet_stress_min_dew_margin_finitial 8
00:16direct_wet_stress_vpd_margin_kpainitial 0.05
00:16dwell_gate_msinitial 285000
00:16enthalpy_closeinitial 1
00:16enthalpy_openinitial -2
00:16fog_escalation_kpainitial 0.4
00:16heat_hysteresisinitial 1
00:16min_fog_off_sinitial 54
00:16min_fog_on_sinitial 66
00:16mist_backoff_sinitial 600
00:16mist_max_closed_vent_sinitial 600
00:16mist_thermal_relief_sinitial 90
00:16mister_all_delay_sinitial 97.5
00:16mister_engage_delay_sinitial 48.75
00:16mister_water_budget_galinitial 120
00:16night_vpd_bias_kpainitial 0
00:16outdoor_staleness_max_sinitial 600
00:16sw_dwell_gate_enabledinitial 1
00:16sw_fog_closes_ventinitial 1
00:16sw_mister_closes_ventinitial 0
00:16sw_summer_vent_enabledinitial 1
00:16temp_hysteresisinitial 2.05
00:16vent_exchange_fractioninitial 0.3
00:16vent_prefer_dp_delta_finitial 9
00:16vent_prefer_temp_delta_finitial 10
00:16vpd_watch_dwell_sinitial 71.25
11:00dwell_gate_ms285000 → 270000
11:00fog_escalation_kpa0.4 → 0.3
11:00mister_all_delay_s97.5 → 93
11:00mister_engage_delay_s48.75 → 46.5
11:00temp_hysteresis2.05 → 1.96
11:00vpd_watch_dwell_s71.25 → 67.5

🌅 Morning Cycle (2:06 AM) — iris-20261116-0203

Status

validated

Outcome score

5/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261115-1643

Result: Window-scoped Nov 16 02:06–06:52 MST (0.199 day): contract-3 joint compliance 81.4%, temp 89.9%, VPD 83.4%; cold stress 0.33h, VPD-low 0.55h, VPD-high/heat/dew-risk 0h. The interval is short, so this is not a full-day result. The prior solar-night diagnostic was available and safety gates passed, but across the night there were 18 ineffective and 7 insufficient-evidence episodes, zero effective, and zero daytime hold admissions; these do not prove plan-caused drying or crop benefit. No durable lesson extracted. Score: 5/10

Hypothesis

Testing: Continue the staged wet-authority observation: 10% cap through humid dawn; reopen bounded assist only on observed VPD high-edge demand, then taper before cold nights. Expected outcome: Against the prior 7-day baseline (VPD-low 8.08–10.75 h/day; temp compliance 93.8–98.6%), seek <8 h/day VPD-low on at least 2 of the next 3 complete days while temp compliance stays >=94%, cold stress ⇐1 h and dew-risk ⇐0.2 h. Grade qualified dry-out separately; coverage is unverified.

Setpoints

Monday November 16

Primary crop-band changes:

TimeValuesNote
02:01hyst 0.26325000000000004Frosty humid dawn: preserve 10% live-edge cap; use only stro
10:30hyst 0.24825000000000003Modest warming/drying ramp: permit bounded assist only at th
17:30hyst 0.26325000000000004Cold evening and overnight low VPD: taper wetting, retain de

Tactical tunable changes:

TimeValuesNote
02:01s2 1.71; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.25; pulse 30; gap 26.25; wt 1.6333333333333333Frosty humid dawn: preserve 10% live-edge cap; use only stro
10:30s2 1.6775; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 30; gap 22.5; wt 1.7000000000000002Modest warming/drying ramp: permit bounded assist only at th
17:30s2 1.76; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.3; pulse 30; gap 30; wt 1.5666666666666669Cold evening and overnight low VPD: taper wetting, retain de

Tuesday November 17

Primary crop-band changes:

TimeValuesNote
10:00hyst 0.24825000000000003Tue/Wed dry ramps: bounded near-edge wet authority, stronger

Tactical tunable changes:

TimeValuesNote
10:00s2 1.6425; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 30; gap 22.5; wt 1.7333333333333334Tue/Wed dry ramps: bounded near-edge wet authority, stronger

Wednesday November 18

Primary crop-band changes:

TimeValuesNote
18:00hyst 0.26325000000000004Wed cold handoff: end wetting before evening; keep useful mo

Tactical tunable changes:

TimeValuesNote
18:00s2 1.725; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.25; pulse 30; gap 30; wt 1.5666666666666669Wed cold handoff: end wetting before evening; keep useful mo

Changed secondary parameters:

TimeParameterChange
02:01band_track_fractioninitial 0
02:01cold_vent_guard_delta_finitial 15
02:01cool_stage2_exit_hysteresis_finitial 1
02:01direct_wet_stress_min_dew_margin_finitial 11
02:01direct_wet_stress_vpd_margin_kpainitial 0.25
02:01dwell_gate_msinitial 315000
02:01enthalpy_closeinitial 1
02:01enthalpy_openinitial -2
02:01fog_escalation_kpainitial 0.35
02:01heat_hysteresisinitial 1
02:01min_fog_off_sinitial 48
02:01min_fog_on_sinitial 68.25
02:01mist_backoff_sinitial 600
02:01mist_max_closed_vent_sinitial 600
02:01mist_thermal_relief_sinitial 90
02:01mister_all_delay_sinitial 106.5
02:01mister_engage_delay_sinitial 53.25
02:01mister_water_budget_galinitial 120
02:01night_vpd_bias_kpainitial 0
02:01outdoor_staleness_max_sinitial 600
02:01sw_dwell_gate_enabledinitial 1
02:01sw_fog_closes_ventinitial 1
02:01sw_mister_closes_ventinitial 0
02:01sw_summer_vent_enabledinitial 1
02:01temp_hysteresisinitial 2.23
02:01vent_exchange_fractioninitial 0.3
02:01vent_prefer_dp_delta_finitial 8
02:01vent_prefer_temp_delta_finitial 12
02:01vpd_watch_dwell_sinitial 78.75
10:30cold_vent_guard_delta_f15 → 12
10:30direct_wet_stress_min_dew_margin_f11 → 9
10:30direct_wet_stress_vpd_margin_kpa0.25 → 0.05
10:30dwell_gate_ms315000 → 270000
10:30fog_escalation_kpa0.35 → 0.3
10:30min_fog_off_s48 → 42
10:30min_fog_on_s68.25 → 70.5
10:30mister_all_delay_s106.5 → 93
10:30mister_engage_delay_s53.25 → 46.5
10:30temp_hysteresis2.23 → 1.96
10:30vent_prefer_dp_delta_f8 → 6
10:30vent_prefer_temp_delta_f12 → 8
10:30vpd_watch_dwell_s78.75 → 67.5
17:30cold_vent_guard_delta_f12 → 15
17:30direct_wet_stress_min_dew_margin_f9 → 11
17:30direct_wet_stress_vpd_margin_kpa0.05 → 0.25
17:30dwell_gate_ms270000 → 315000
17:30fog_escalation_kpa0.3 → 0.4
17:30min_fog_off_s42 → 54
17:30min_fog_on_s70.5 → 66
17:30mister_all_delay_s93 → 106.5
17:30mister_engage_delay_s46.5 → 53.25
17:30temp_hysteresis1.96 → 2.23
17:30vent_prefer_dp_delta_f6 → 8
17:30vent_prefer_temp_delta_f8 → 12
17:30vpd_watch_dwell_s67.5 → 78.75
10:00cold_vent_guard_delta_f15 → 12
10:00direct_wet_stress_min_dew_margin_f11 → 8
10:00direct_wet_stress_vpd_margin_kpa0.25 → 0.05
10:00dwell_gate_ms315000 → 270000
10:00fog_escalation_kpa0.4 → 0.22
10:00min_fog_off_s54 → 42
10:00min_fog_on_s66 → 70.5
10:00mister_all_delay_s106.5 → 93
10:00mister_engage_delay_s53.25 → 46.5
10:00temp_hysteresis2.23 → 1.96
10:00vent_prefer_dp_delta_f8 → 6
10:00vent_prefer_temp_delta_f12 → 8
10:00vpd_watch_dwell_s78.75 → 67.5
18:00cold_vent_guard_delta_f12 → 15
18:00direct_wet_stress_min_dew_margin_f8 → 11
18:00direct_wet_stress_vpd_margin_kpa0.05 → 0.25
18:00dwell_gate_ms270000 → 315000
18:00fog_escalation_kpa0.22 → 0.4
18:00min_fog_off_s42 → 54
18:00min_fog_on_s70.5 → 66
18:00mister_all_delay_s93 → 106.5
18:00mister_engage_delay_s46.5 → 53.25
18:00temp_hysteresis1.96 → 2.23
18:00vent_prefer_dp_delta_f6 → 8
18:00vent_prefer_temp_delta_f8 → 12
18:00vpd_watch_dwell_s67.5 → 78.75

🌅 Morning Cycle (6:52 AM) — iris-20261116-0648

Status

validated

Outcome score

5/10

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Validating previous cycle: iris-20261115-1643

Result: SUNSET cutoff review of iris-20261116-0648 through 16:46 MST only (0.413 day): contract-3 joint compliance 81.4%, temp 89.9%, VPD 83.4%; cold 0.69h, VPD-low 1.14h, heat/VPD-high/dew-risk 0h. The cold dawn miss was limited, but the predicted VPD-low window beginning 18:30 was after this replacement cutoff and remains untested. Forecast actuals differed (outdoor peak 56.1F vs 62F, RH minimum 45% vs 32%, solar peak 570 vs 444 W/m2); guardrail audit shows held/mismatched actions, weakening attribution. No causal benefit or durable lesson established. Score: 5/10

Hypothesis

Testing: Test staged cool-dawn wet authority: hold 10% through the humid ramp, allow 20% only near live high-edge demand, then taper on observed recovery; inspect held versus dispatched actions. Expected outcome: On the complete contract-3 day, keep temp compliance near or above 93.8%, reduce VPD-low below 10.08h, maintain zero dew-risk, and keep VPD-high below 1h; verify from the full-day scorecard and action proof.

Conditions

Outdoor peak

62.0°F

RH minimum

32.0%

Solar peak

444.0 W/m²

Cloud average

55.0%

Frosty 29F dawn; house 66.6F/VPD 1.04 with 16.3F dew margin. Prior day scored 54.5% joint (93.8% temp, 57.3% VPD), dominated by 10.08h VPD-low. Live zone spread is large (south 1.70, north 0.74). The 18h forecast is stale but indicates a moderate 62F/1.27kPa afternoon followed by cloudy cooling.

Expected stress windows

coldhigh · 2026-11-16T06:48:00-07:00 to 2026-11-16T09:00:00-07:00

Keep outdoor exchange conservative and relay transitions damped through the 29F dawn.

vpd_lowhigh · 2026-11-16T18:30:00-07:00 to 2026-11-17T00:30:00-07:00

Taper wet assist after observed high-edge recovery; retain dew-safe drying and avoid evening mist carryover.

Parameter rationale

mister_engage_kpa1.15 → 1.234; House VPD 1.04 is in band, but the south is 1.70 and outdoor VPD peaks at 1.27; forecast is stale.

Avoid broad dawn wetting while permitting bounded afternoon assist near the live served high edge.

fog_escalation_kpa0.35 → 0.3; Moderate 62F afternoon with outdoor VPD near 1.27, well below extreme hot-dry conditions.

Keep heavy fog behind a modest live VPD excess and avoid adding humidity during the cool humid recovery.

Setpoints

Monday November 16

Primary crop-band changes:

TimeValuesNote
06:48hyst 0.1865Dawn frost: favor steady heat and defer wetting until measur
09:30hyst 0.1865Keep a light wet cap through the humid morning; reopen only
13:30hyst 0.1865Peak dry ramp: make bounded, band-coupled wet assist availab
16:00hyst 0.1865As skies cloud and VPD falls, taper duty but keep brief reco
18:30hyst 0.1865Cool evening: minimize wet carryover, but unwind only after

Tactical tunable changes:

TimeValuesNote
06:48s2 1.8900000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7Dawn frost: favor steady heat and defer wetting until measur
09:30s2 1.8375000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7Keep a light wet cap through the humid morning; reopen only
13:30s2 1.7200000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002Peak dry ramp: make bounded, band-coupled wet assist availab
16:00s2 1.8550000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7As skies cloud and VPD falls, taper duty but keep brief reco
18:30s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7Cool evening: minimize wet carryover, but unwind only after

Changed secondary parameters:

TimeParameterChange
06:48band_track_fractioninitial 0
06:48cold_vent_guard_delta_finitial 15
06:48cool_stage2_exit_hysteresis_finitial 1
06:48direct_wet_stress_min_dew_margin_finitial 8
06:48direct_wet_stress_vpd_margin_kpainitial 0.05
06:48dwell_gate_msinitial 210000
06:48enthalpy_closeinitial 1
06:48enthalpy_openinitial -2
06:48fog_escalation_kpainitial 0.25
06:48heat_hysteresisinitial 1
06:48min_fog_off_sinitial 66
06:48min_fog_on_sinitial 61.5
06:48mist_backoff_sinitial 600
06:48mist_max_closed_vent_sinitial 600
06:48mist_thermal_relief_sinitial 90
06:48mister_all_delay_sinitial 75
06:48mister_engage_delay_sinitial 37.5
06:48mister_water_budget_galinitial 120
06:48night_vpd_bias_kpainitial 0
06:48outdoor_staleness_max_sinitial 600
06:48sw_dwell_gate_enabledinitial 1
06:48sw_fog_closes_ventinitial 1
06:48sw_mister_closes_ventinitial 0
06:48sw_summer_vent_enabledinitial 1
06:48temp_hysteresisinitial 1.6
06:48vent_exchange_fractioninitial 0.3
06:48vent_prefer_dp_delta_finitial 8
06:48vent_prefer_temp_delta_finitial 12
06:48vpd_watch_dwell_sinitial 52.5
13:30min_fog_off_s66 → 54
13:30min_fog_on_s61.5 → 66
16:00min_fog_off_s54 → 66
16:00min_fog_on_s66 → 61.5
18:30min_fog_off_s66 → 72
18:30min_fog_on_s61.5 → 59.25

🌆 Evening Cycle (4:52 PM) — iris-20261116-1648

Status

Daily Summary So Far

Outcome score

not validated yet

Changed parameters

band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...

Reflection

Daily Summary So Far — this cycle will be validated at the next planning cycle.

Hypothesis

Testing: Test low-duty, wider-interval wet intent through a cold humid night; verify served-band stress, actual relay/readback, and dew margin at sunrise. Expected outcome: Across the overnight governed window, target VPD-low stress under 2h, cold stress under 1h, and 0 dew-risk hours; retain response to measured VPD-high and verify the intended waypoints/readbacks.

Conditions

Outdoor peak

53.0°F

RH minimum

48.0%

Solar peak

13.0 W/m²

Cloud average

95.0%

Forecast falls to 31F by 07:00; RH rises to 78-86% and outdoor VPD is 0.08-0.18 overnight. House is 70.3F/VPD 1.16 with 17.2F dew margin; heat1 and heat2 are on. Prior plans 0203 and 0648 each scored 5/10 vs anchor 5; 0648’s forecast VPD-low window after 18:30 was not observed by sunset. The realized solar night had 18 ineffective, 7 insufficient-evidence, 0 effective episodes; safety pass is not effectiveness.

Expected stress windows

coldhigh · 2026-11-16T20:00:00-07:00 to 2026-11-17T07:00:00-07:00

Hold heat steadily, keep outdoor exchange conservative, and avoid ordinary heater-vent reversals.

vpd_lowhigh · 2026-11-16T21:00:00-07:00 to 2026-11-17T07:00:00-07:00

Use low wet duty and a wider effective pulse interval; preserve nonzero live-edge recovery and dew safety.

Parameter rationale

mister_pulse_gap_s30.0 → 45.0; Outdoor VPD 0.08-0.18 kPa and RH 78-86% overnight; today's partial VPD-low stress is 2.75h.

The low-duty overnight intent should reduce VPD-low to under 2h while retaining live-edge response and keeping dew-risk at 0h.

Setpoints

Monday November 16

Primary crop-band changes:

TimeValuesNote
16:47hyst 0.1875evening_settle: frost front arrives; limit wet duty and requ

Tactical tunable changes:

TimeValuesNote
16:47s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002evening_settle: frost front arrives; limit wet duty and requ

Tuesday November 17

Primary crop-band changes:

TimeValuesNote
00:00hyst 0.1875midnight_posture: cold humid trough favors heat stability an
05:30hyst 0.1875pre_dawn: maintain a small band-triggered recovery bridge wi

Tactical tunable changes:

TimeValuesNote
00:00s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002midnight_posture: cold humid trough favors heat stability an
05:30s2 1.7725000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002pre_dawn: maintain a small band-triggered recovery bridge wi

Changed secondary parameters:

TimeParameterChange
16:47band_track_fractioninitial 0
16:47cold_vent_guard_delta_finitial 15
16:47cool_stage2_exit_hysteresis_finitial 1
16:47direct_wet_stress_min_dew_margin_finitial 9
16:47direct_wet_stress_vpd_margin_kpainitial 0.05
16:47dwell_gate_msinitial 210000
16:47enthalpy_closeinitial 1
16:47enthalpy_openinitial -2
16:47fog_escalation_kpainitial 0.25
16:47heat_hysteresisinitial 1
16:47min_fog_off_sinitial 54
16:47min_fog_on_sinitial 66
16:47mist_backoff_sinitial 600
16:47mist_max_closed_vent_sinitial 600
16:47mist_thermal_relief_sinitial 90
16:47mister_all_delay_sinitial 75
16:47mister_engage_delay_sinitial 37.5
16:47mister_water_budget_galinitial 300
16:47night_vpd_bias_kpainitial 0
16:47outdoor_staleness_max_sinitial 600
16:47sw_dwell_gate_enabledinitial 1
16:47sw_fog_closes_ventinitial 1
16:47sw_mister_closes_ventinitial 0
16:47sw_summer_vent_enabledinitial 1
16:47temp_hysteresisinitial 1.6
16:47vent_exchange_fractioninitial 0.3
16:47vent_prefer_dp_delta_finitial 10
16:47vent_prefer_temp_delta_finitial 15
16:47vpd_watch_dwell_sinitial 52.5

Daily Summary So Far

Climate

Temperature

58.5–85.1°F; avg 68.2°F

VPD

0.53–1.44 kPa; avg 0.94 kPa

Relative humidity

47.6–74.9%

Interior Light Evidence

  • Crop DLI: unavailable
  • Reason: source_reading_missing
  • Provenance: par_quantum_sensor_canopy
  • Validity: dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open
  • Qualified-light minutes and photoperiod remain independent of unavailable DLI.

Stress Hours

  • Heat stress (above the served band): 0.0h
  • VPD stress (above the served band): 0.0h
  • Cold stress (below the served band): 1.7h

Economics

Electric

USD 4.36

Gas

USD 2.38

Water

Not available

Total

Not available

Equipment Runtimes

EquipmentRuntimeReading
Fan 135 minPrimary exhaust runtime.
Fan 236 minSecondary exhaust runtime.
Vent71 minIntake vent runtime.
Fog6 minFogger runtime.
Heat 1 electric1047 minElectric heater runtime.
Heat 2 gas229 minGas heater runtime.
Grow lights1151 minSupplemental lighting runtime.
Mister south0.00hSouth mister runtime.
Mister west0.00hWest mister runtime.
Mister center0.00hCenter mister runtime.

Water

  • Total: 49 gal
  • Mister: — gal

Crop Health (Gemini Vision)

CropZoneHealthObservationsNote
Vanda Orchidscenter78%4Observation notes are collapsed below to avoid publishing partial vision snippets.
Vision observation notes
Vanda OrchidsGemini Vision notes

Plants appear healthy with green foliage and active root systems visible. No signs of stress or disease. || Plants appear turgid and healthy; no visible signs of stress or damage. || [fallen petals on floor] Plants appear generally healthy with green foliage; some fallen petals observed on floor indicating recent bloom or natural shedding. || [fallen petals on floor] Plants appear healthy with green foliage and active root systems visible. Fallen petals suggest recent blooming or minor handling stress, not systemic issue.

Hourly Pattern

HourTemperatureVPDRH
10:0073.1°F1.01 kPa64.7%
11:0076.2°F1.09 kPa65.8%
12:0076.2°F1.09 kPa65.7%
13:0077.3°F1.08 kPa66.7%
14:0079.6°F1.16 kPa66.5%
15:0081.3°F1.16 kPa69.0%
16:0074.6°F0.88 kPa70.4%
17:0072.0°F0.86 kPa68.3%
18:0071.8°F0.94 kPa65.4%
19:0069.3°F0.85 kPa65.8%
20:0066.4°F0.75 kPa66.8%
21:0064.2°F0.67 kPa68.0%
22:0064.0°F0.73 kPa64.4%
23:0063.1°F0.81 kPa59.7%
00:0061.6°F0.75 kPa60.3%
01:0061.4°F0.77 kPa59.3%
02:0061.4°F0.77 kPa59.3%
03:0060.8°F0.76 kPa58.5%
04:0061.5°F0.79 kPa58.2%
05:0062.8°F0.81 kPa59.5%
06:0063.8°F0.85 kPa58.9%
07:0065.2°F0.71 kPa67.4%
08:0068.4°F0.94 kPa61.5%
09:0069.0°F0.91 kPa63.5%

7-Day Stress Context

DateHeatVPD highCold
2026-11-100.0h0.1h0.8h
2026-11-110.0h0.0h0.3h
2026-11-120.0h0.1h0.4h
2026-11-130.0h0.0h0.4h
2026-11-140.0h0.0h1.1h
2026-11-150.0h0.2h1.5h
2026-11-160.0h0.0h1.7h