November 16, 2026
Generated lab notebook from daily_summary, plan_journal, plan_delivery_log, and setpoint audit data. It is intentionally chronological and may include in-progress cycles before validation.
Planner Execution Ledger
Planner checkpoints can acknowledge that the active plan is still suitable without writing a new public plan ID. Those no-change decisions are part of the audit trail.
10
3
2
0
| Event | Delivered | Type | Status | Note |
|---|---|---|---|---|
| End-of-day review and reset | 00:15 | MIDNIGHT | plan_written | Wrote public plan iris-20261116-0016. Resolved 00:18 MDT. |
| Morning planning cycle | 06:48 | SUNRISE | plan_written | Wrote public plan iris-20261116-0648. Resolved 06:52 MDT. |
| Solar peak planning checkpoint | 11:45 | SOLAR_MAX | action_completed | Delivery recorded without a public plan write. Resolved 11:47 MDT. |
| Peak Stress | 13:46 | TRANSITION | acked | Acknowledged: Peak checkpoint tracks the governing posture: indoor 75.1°F and VPD 1.17 kPa are within the served band, VPD-high stress is absent, and dew margin is 14.6°F. Current mode is IDLE; forecast turns colder and more humid, so no added wet aggression is warranted. Resolved 13:46 MDT. |
| Decline | 15:43 | TRANSITION | acked | Acknowledged: Decline checkpoint is tracking the active plan: house is IDLE at 80.4°F / 1.07 kPa, within the served band, dew margin 10.5°F, and all wet/cooling relays are off. The forecast turns sharply colder and more humid overnight; existing evening waypoints already taper posture. No concrete signal warrants a one-shot tunable change; leaving the manually held fog setting untouched. Resolved 15:44 MDT. |
| Evening planning cycle | 16:43 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 16:44 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 16:45 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 16:46 | SUNSET | delivery_failed | Delivery recorded without a public plan write. |
| Evening planning cycle | 16:47 | SUNSET | plan_written | Wrote public plan iris-20261116-1648. Resolved 16:52 MDT. |
🌅 Morning Cycle (12:18 AM) — iris-20261116-0016
validated
4/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261115-1643
Previous hypothesis: {“conditions”:{“outdoor_temp_peak_f”:49.0,“outdoor_rh_min_pct”:71.0,“solar_peak_w_m2”:0,“cloud_cover_avg_pct”:35.667,“notes”:“Forecast falls to 35F with RH 93-100% and outdoor VPD 0-0.05 before dawn; indoor is 72.9F, VPD 0.80, dew margin 9.8F. Today’s partial VPD-low stress dominates. Prior iris-20261115-0016 self-grade 4 vs anchor 1 over-credited a short window despite weak joint/VPD and many held guardrails; keep attribution cautious.”},“stress_windows”:[{“kind”:“vpd_low”,“start”:“2026-11-15T20:00:00-07:00”,“end”:“2026-11-16T09:00:00-07:00”,“severity”:“high”,“mitigation”:“Keep wet assist capped at 10%, live-edge-only; avoid unnecessary mist/fog through the saturated trough… Result: Correction to the prior evaluation note: dry-out episode timestamps are UTC and must be converted to America/Denver. For iris-20261116-0016’s 00:18–02:06 MST window, 13 of 25 night episodes preceded the plan, 6 overlapped it, and 6 followed its 02:06 cutoff. The six overlapping episodes include four complete/ineffective and two incomplete/insufficient-evidence episodes; the full solar night totals 18 ineffective and 7 insufficient-evidence episodes, with safety gates passing. Relay truth during these short episodes showed vent/fans and heat1 active, wet relays off; the mixed, short-window evidence does not establish plan-caused dry-out effectiveness. The plan-scoped contract-3 score remains 72.2% over only 0.075 day: temp 86.1%, VPD 73.4%, cold 0.07h, VPD-low 0.13h, VPD-high 0h, dew-risk 0h. This ends before most of the planned humid-dawn/handoff interval. Guardrail audit recorded 65 VPD-high events, 45 held and 20 dispatched, further limiting attribution. No durable lesson extracted; coverage and crop outcomes remain unverified. Score: 4/10
Hypothesis
Testing: Continue the staged wet-authority trial: 10% duty cap during humid dawn, live-edge demand only; no new treatment claim. Expected outcome: Through humid dawn, preserve dew margin at or above 8°F and limit added wetting; at 11:00 reopen modest assist only on live VPD edge evidence. Judge by scoped served-band compliance and held-guardrail counts.
Setpoints
Monday November 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | hyst 0.25125000000000003 | Frost and saturated air: preserve heat, cap wetting at 10% a |
| 04:45 | hyst 0.25125000000000003 | Carry the humid-dawn live-edge cap through the coldest hours |
| 08:30 | hyst 0.25125000000000003 | Keep wet authority bounded while outdoor air remains saturat |
| 11:00 | hyst 0.24625000000000002 | Early-day handoff: modestly reopen band-coupled wet assist o |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:16 | s2 1.5925000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6 | Frost and saturated air: preserve heat, cap wetting at 10% a |
| 04:45 | s2 1.5925000000000002; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6 | Carry the humid-dawn live-edge cap through the coldest hours |
| 08:30 | s2 1.6561000000000001; cool_exit 2.05; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.2; pulse 30; gap 30; wt 1.6 | Keep wet authority bounded while outdoor air remains saturat |
| 11:00 | s2 1.6561000000000001; cool_exit 1.96; all_fans 0; dw_stress 0; engage 0.9500000000000001; all 1.15; pulse 30; gap 30; wt 1.6533333333333333 | Early-day handoff: modestly reopen band-coupled wet assist o |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 00:16 | band_track_fraction | initial 0 |
| 00:16 | cold_vent_guard_delta_f | initial 14 |
| 00:16 | cool_stage2_exit_hysteresis_f | initial 1 |
| 00:16 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 00:16 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 00:16 | dwell_gate_ms | initial 285000 |
| 00:16 | enthalpy_close | initial 1 |
| 00:16 | enthalpy_open | initial -2 |
| 00:16 | fog_escalation_kpa | initial 0.4 |
| 00:16 | heat_hysteresis | initial 1 |
| 00:16 | min_fog_off_s | initial 54 |
| 00:16 | min_fog_on_s | initial 66 |
| 00:16 | mist_backoff_s | initial 600 |
| 00:16 | mist_max_closed_vent_s | initial 600 |
| 00:16 | mist_thermal_relief_s | initial 90 |
| 00:16 | mister_all_delay_s | initial 97.5 |
| 00:16 | mister_engage_delay_s | initial 48.75 |
| 00:16 | mister_water_budget_gal | initial 120 |
| 00:16 | night_vpd_bias_kpa | initial 0 |
| 00:16 | outdoor_staleness_max_s | initial 600 |
| 00:16 | sw_dwell_gate_enabled | initial 1 |
| 00:16 | sw_fog_closes_vent | initial 1 |
| 00:16 | sw_mister_closes_vent | initial 0 |
| 00:16 | sw_summer_vent_enabled | initial 1 |
| 00:16 | temp_hysteresis | initial 2.05 |
| 00:16 | vent_exchange_fraction | initial 0.3 |
| 00:16 | vent_prefer_dp_delta_f | initial 9 |
| 00:16 | vent_prefer_temp_delta_f | initial 10 |
| 00:16 | vpd_watch_dwell_s | initial 71.25 |
| 11:00 | dwell_gate_ms | 285000 → 270000 |
| 11:00 | fog_escalation_kpa | 0.4 → 0.3 |
| 11:00 | mister_all_delay_s | 97.5 → 93 |
| 11:00 | mister_engage_delay_s | 48.75 → 46.5 |
| 11:00 | temp_hysteresis | 2.05 → 1.96 |
| 11:00 | vpd_watch_dwell_s | 71.25 → 67.5 |
🌅 Morning Cycle (2:06 AM) — iris-20261116-0203
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261115-1643
Result: Window-scoped Nov 16 02:06–06:52 MST (0.199 day): contract-3 joint compliance 81.4%, temp 89.9%, VPD 83.4%; cold stress 0.33h, VPD-low 0.55h, VPD-high/heat/dew-risk 0h. The interval is short, so this is not a full-day result. The prior solar-night diagnostic was available and safety gates passed, but across the night there were 18 ineffective and 7 insufficient-evidence episodes, zero effective, and zero daytime hold admissions; these do not prove plan-caused drying or crop benefit. No durable lesson extracted. Score: 5/10
Hypothesis
Testing: Continue the staged wet-authority observation: 10% cap through humid dawn; reopen bounded assist only on observed VPD high-edge demand, then taper before cold nights. Expected outcome: Against the prior 7-day baseline (VPD-low 8.08–10.75 h/day; temp compliance 93.8–98.6%), seek <8 h/day VPD-low on at least 2 of the next 3 complete days while temp compliance stays >=94%, cold stress ⇐1 h and dew-risk ⇐0.2 h. Grade qualified dry-out separately; coverage is unverified.
Setpoints
Monday November 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 02:01 | hyst 0.26325000000000004 | Frosty humid dawn: preserve 10% live-edge cap; use only stro |
| 10:30 | hyst 0.24825000000000003 | Modest warming/drying ramp: permit bounded assist only at th |
| 17:30 | hyst 0.26325000000000004 | Cold evening and overnight low VPD: taper wetting, retain de |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 02:01 | s2 1.71; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.25; pulse 30; gap 26.25; wt 1.6333333333333333 | Frosty humid dawn: preserve 10% live-edge cap; use only stro |
| 10:30 | s2 1.6775; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 30; gap 22.5; wt 1.7000000000000002 | Modest warming/drying ramp: permit bounded assist only at th |
| 17:30 | s2 1.76; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.3; pulse 30; gap 30; wt 1.5666666666666669 | Cold evening and overnight low VPD: taper wetting, retain de |
Tuesday November 17
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | hyst 0.24825000000000003 | Tue/Wed dry ramps: bounded near-edge wet authority, stronger |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 10:00 | s2 1.6425; cool_exit 1.96; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 30; gap 22.5; wt 1.7333333333333334 | Tue/Wed dry ramps: bounded near-edge wet authority, stronger |
Wednesday November 18
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | hyst 0.26325000000000004 | Wed cold handoff: end wetting before evening; keep useful mo |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 18:00 | s2 1.725; cool_exit 2.23; all_fans 0; dw_stress 0; engage 1.15; all 1.25; pulse 30; gap 30; wt 1.5666666666666669 | Wed cold handoff: end wetting before evening; keep useful mo |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 02:01 | band_track_fraction | initial 0 |
| 02:01 | cold_vent_guard_delta_f | initial 15 |
| 02:01 | cool_stage2_exit_hysteresis_f | initial 1 |
| 02:01 | direct_wet_stress_min_dew_margin_f | initial 11 |
| 02:01 | direct_wet_stress_vpd_margin_kpa | initial 0.25 |
| 02:01 | dwell_gate_ms | initial 315000 |
| 02:01 | enthalpy_close | initial 1 |
| 02:01 | enthalpy_open | initial -2 |
| 02:01 | fog_escalation_kpa | initial 0.35 |
| 02:01 | heat_hysteresis | initial 1 |
| 02:01 | min_fog_off_s | initial 48 |
| 02:01 | min_fog_on_s | initial 68.25 |
| 02:01 | mist_backoff_s | initial 600 |
| 02:01 | mist_max_closed_vent_s | initial 600 |
| 02:01 | mist_thermal_relief_s | initial 90 |
| 02:01 | mister_all_delay_s | initial 106.5 |
| 02:01 | mister_engage_delay_s | initial 53.25 |
| 02:01 | mister_water_budget_gal | initial 120 |
| 02:01 | night_vpd_bias_kpa | initial 0 |
| 02:01 | outdoor_staleness_max_s | initial 600 |
| 02:01 | sw_dwell_gate_enabled | initial 1 |
| 02:01 | sw_fog_closes_vent | initial 1 |
| 02:01 | sw_mister_closes_vent | initial 0 |
| 02:01 | sw_summer_vent_enabled | initial 1 |
| 02:01 | temp_hysteresis | initial 2.23 |
| 02:01 | vent_exchange_fraction | initial 0.3 |
| 02:01 | vent_prefer_dp_delta_f | initial 8 |
| 02:01 | vent_prefer_temp_delta_f | initial 12 |
| 02:01 | vpd_watch_dwell_s | initial 78.75 |
| 10:30 | cold_vent_guard_delta_f | 15 → 12 |
| 10:30 | direct_wet_stress_min_dew_margin_f | 11 → 9 |
| 10:30 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 10:30 | dwell_gate_ms | 315000 → 270000 |
| 10:30 | fog_escalation_kpa | 0.35 → 0.3 |
| 10:30 | min_fog_off_s | 48 → 42 |
| 10:30 | min_fog_on_s | 68.25 → 70.5 |
| 10:30 | mister_all_delay_s | 106.5 → 93 |
| 10:30 | mister_engage_delay_s | 53.25 → 46.5 |
| 10:30 | temp_hysteresis | 2.23 → 1.96 |
| 10:30 | vent_prefer_dp_delta_f | 8 → 6 |
| 10:30 | vent_prefer_temp_delta_f | 12 → 8 |
| 10:30 | vpd_watch_dwell_s | 78.75 → 67.5 |
| 17:30 | cold_vent_guard_delta_f | 12 → 15 |
| 17:30 | direct_wet_stress_min_dew_margin_f | 9 → 11 |
| 17:30 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.25 |
| 17:30 | dwell_gate_ms | 270000 → 315000 |
| 17:30 | fog_escalation_kpa | 0.3 → 0.4 |
| 17:30 | min_fog_off_s | 42 → 54 |
| 17:30 | min_fog_on_s | 70.5 → 66 |
| 17:30 | mister_all_delay_s | 93 → 106.5 |
| 17:30 | mister_engage_delay_s | 46.5 → 53.25 |
| 17:30 | temp_hysteresis | 1.96 → 2.23 |
| 17:30 | vent_prefer_dp_delta_f | 6 → 8 |
| 17:30 | vent_prefer_temp_delta_f | 8 → 12 |
| 17:30 | vpd_watch_dwell_s | 67.5 → 78.75 |
| 10:00 | cold_vent_guard_delta_f | 15 → 12 |
| 10:00 | direct_wet_stress_min_dew_margin_f | 11 → 8 |
| 10:00 | direct_wet_stress_vpd_margin_kpa | 0.25 → 0.05 |
| 10:00 | dwell_gate_ms | 315000 → 270000 |
| 10:00 | fog_escalation_kpa | 0.4 → 0.22 |
| 10:00 | min_fog_off_s | 54 → 42 |
| 10:00 | min_fog_on_s | 66 → 70.5 |
| 10:00 | mister_all_delay_s | 106.5 → 93 |
| 10:00 | mister_engage_delay_s | 53.25 → 46.5 |
| 10:00 | temp_hysteresis | 2.23 → 1.96 |
| 10:00 | vent_prefer_dp_delta_f | 8 → 6 |
| 10:00 | vent_prefer_temp_delta_f | 12 → 8 |
| 10:00 | vpd_watch_dwell_s | 78.75 → 67.5 |
| 18:00 | cold_vent_guard_delta_f | 12 → 15 |
| 18:00 | direct_wet_stress_min_dew_margin_f | 8 → 11 |
| 18:00 | direct_wet_stress_vpd_margin_kpa | 0.05 → 0.25 |
| 18:00 | dwell_gate_ms | 270000 → 315000 |
| 18:00 | fog_escalation_kpa | 0.22 → 0.4 |
| 18:00 | min_fog_off_s | 42 → 54 |
| 18:00 | min_fog_on_s | 70.5 → 66 |
| 18:00 | mister_all_delay_s | 93 → 106.5 |
| 18:00 | mister_engage_delay_s | 46.5 → 53.25 |
| 18:00 | temp_hysteresis | 1.96 → 2.23 |
| 18:00 | vent_prefer_dp_delta_f | 6 → 8 |
| 18:00 | vent_prefer_temp_delta_f | 8 → 12 |
| 18:00 | vpd_watch_dwell_s | 67.5 → 78.75 |
🌅 Morning Cycle (6:52 AM) — iris-20261116-0648
validated
5/10
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Validating previous cycle: iris-20261115-1643
Result: SUNSET cutoff review of iris-20261116-0648 through 16:46 MST only (0.413 day): contract-3 joint compliance 81.4%, temp 89.9%, VPD 83.4%; cold 0.69h, VPD-low 1.14h, heat/VPD-high/dew-risk 0h. The cold dawn miss was limited, but the predicted VPD-low window beginning 18:30 was after this replacement cutoff and remains untested. Forecast actuals differed (outdoor peak 56.1F vs 62F, RH minimum 45% vs 32%, solar peak 570 vs 444 W/m2); guardrail audit shows held/mismatched actions, weakening attribution. No causal benefit or durable lesson established. Score: 5/10
Hypothesis
Testing: Test staged cool-dawn wet authority: hold 10% through the humid ramp, allow 20% only near live high-edge demand, then taper on observed recovery; inspect held versus dispatched actions. Expected outcome: On the complete contract-3 day, keep temp compliance near or above 93.8%, reduce VPD-low below 10.08h, maintain zero dew-risk, and keep VPD-high below 1h; verify from the full-day scorecard and action proof.
Conditions
62.0°F
32.0%
444.0 W/m²
55.0%
Frosty 29F dawn; house 66.6F/VPD 1.04 with 16.3F dew margin. Prior day scored 54.5% joint (93.8% temp, 57.3% VPD), dominated by 10.08h VPD-low. Live zone spread is large (south 1.70, north 0.74). The 18h forecast is stale but indicates a moderate 62F/1.27kPa afternoon followed by cloudy cooling.
Expected stress windows
Keep outdoor exchange conservative and relay transitions damped through the 29F dawn.
Taper wet assist after observed high-edge recovery; retain dew-safe drying and avoid evening mist carryover.
Parameter rationale
Avoid broad dawn wetting while permitting bounded afternoon assist near the live served high edge.
Keep heavy fog behind a modest live VPD excess and avoid adding humidity during the cool humid recovery.
Setpoints
Monday November 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 06:48 | hyst 0.1865 | Dawn frost: favor steady heat and defer wetting until measur |
| 09:30 | hyst 0.1865 | Keep a light wet cap through the humid morning; reopen only |
| 13:30 | hyst 0.1865 | Peak dry ramp: make bounded, band-coupled wet assist availab |
| 16:00 | hyst 0.1865 | As skies cloud and VPD falls, taper duty but keep brief reco |
| 18:30 | hyst 0.1865 | Cool evening: minimize wet carryover, but unwind only after |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 06:48 | s2 1.8900000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Dawn frost: favor steady heat and defer wetting until measur |
| 09:30 | s2 1.8375000000000001; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | Keep a light wet cap through the humid morning; reopen only |
| 13:30 | s2 1.7200000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 30; wt 1.7000000000000002 | Peak dry ramp: make bounded, band-coupled wet assist availab |
| 16:00 | s2 1.8550000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 37.5; wt 1.7 | As skies cloud and VPD falls, taper duty but keep brief reco |
| 18:30 | s2 1.905; cool_exit 1.6; all_fans 0; dw_stress 1; engage 0.9500000000000001; all 1.15; pulse 33.75; gap 41.25; wt 1.7 | Cool evening: minimize wet carryover, but unwind only after |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 06:48 | band_track_fraction | initial 0 |
| 06:48 | cold_vent_guard_delta_f | initial 15 |
| 06:48 | cool_stage2_exit_hysteresis_f | initial 1 |
| 06:48 | direct_wet_stress_min_dew_margin_f | initial 8 |
| 06:48 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 06:48 | dwell_gate_ms | initial 210000 |
| 06:48 | enthalpy_close | initial 1 |
| 06:48 | enthalpy_open | initial -2 |
| 06:48 | fog_escalation_kpa | initial 0.25 |
| 06:48 | heat_hysteresis | initial 1 |
| 06:48 | min_fog_off_s | initial 66 |
| 06:48 | min_fog_on_s | initial 61.5 |
| 06:48 | mist_backoff_s | initial 600 |
| 06:48 | mist_max_closed_vent_s | initial 600 |
| 06:48 | mist_thermal_relief_s | initial 90 |
| 06:48 | mister_all_delay_s | initial 75 |
| 06:48 | mister_engage_delay_s | initial 37.5 |
| 06:48 | mister_water_budget_gal | initial 120 |
| 06:48 | night_vpd_bias_kpa | initial 0 |
| 06:48 | outdoor_staleness_max_s | initial 600 |
| 06:48 | sw_dwell_gate_enabled | initial 1 |
| 06:48 | sw_fog_closes_vent | initial 1 |
| 06:48 | sw_mister_closes_vent | initial 0 |
| 06:48 | sw_summer_vent_enabled | initial 1 |
| 06:48 | temp_hysteresis | initial 1.6 |
| 06:48 | vent_exchange_fraction | initial 0.3 |
| 06:48 | vent_prefer_dp_delta_f | initial 8 |
| 06:48 | vent_prefer_temp_delta_f | initial 12 |
| 06:48 | vpd_watch_dwell_s | initial 52.5 |
| 13:30 | min_fog_off_s | 66 → 54 |
| 13:30 | min_fog_on_s | 61.5 → 66 |
| 16:00 | min_fog_off_s | 54 → 66 |
| 16:00 | min_fog_on_s | 66 → 61.5 |
| 18:30 | min_fog_off_s | 66 → 72 |
| 18:30 | min_fog_on_s | 61.5 → 59.25 |
🌆 Evening Cycle (4:52 PM) — iris-20261116-1648
Daily Summary So Far
not validated yet
band_track_fraction, cold_vent_guard_delta_f, cool_exit_hysteresis_f, cool_stage2_exit_hysteresis_f, cool_stage2_over_high_f, direct_wet_stress_min_dew_margin_f, direct_wet_stress_vpd_margin_kpa, dwell_gate_ms ...
Reflection
Daily Summary So Far — this cycle will be validated at the next planning cycle.
Hypothesis
Testing: Test low-duty, wider-interval wet intent through a cold humid night; verify served-band stress, actual relay/readback, and dew margin at sunrise. Expected outcome: Across the overnight governed window, target VPD-low stress under 2h, cold stress under 1h, and 0 dew-risk hours; retain response to measured VPD-high and verify the intended waypoints/readbacks.
Conditions
53.0°F
48.0%
13.0 W/m²
95.0%
Forecast falls to 31F by 07:00; RH rises to 78-86% and outdoor VPD is 0.08-0.18 overnight. House is 70.3F/VPD 1.16 with 17.2F dew margin; heat1 and heat2 are on. Prior plans 0203 and 0648 each scored 5/10 vs anchor 5; 0648’s forecast VPD-low window after 18:30 was not observed by sunset. The realized solar night had 18 ineffective, 7 insufficient-evidence, 0 effective episodes; safety pass is not effectiveness.
Expected stress windows
Hold heat steadily, keep outdoor exchange conservative, and avoid ordinary heater-vent reversals.
Use low wet duty and a wider effective pulse interval; preserve nonzero live-edge recovery and dew safety.
Parameter rationale
The low-duty overnight intent should reduce VPD-low to under 2h while retaining live-edge response and keeping dew-risk at 0h.
Setpoints
Monday November 16
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 16:47 | hyst 0.1875 | evening_settle: frost front arrives; limit wet duty and requ |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 16:47 | s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002 | evening_settle: frost front arrives; limit wet duty and requ |
Tuesday November 17
Primary crop-band changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | hyst 0.1875 | midnight_posture: cold humid trough favors heat stability an |
| 05:30 | hyst 0.1875 | pre_dawn: maintain a small band-triggered recovery bridge wi |
Tactical tunable changes:
| Time | Values | Note |
|---|---|---|
| 00:00 | s2 1.86; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002 | midnight_posture: cold humid trough favors heat stability an |
| 05:30 | s2 1.7725000000000002; cool_exit 1.6; all_fans 0; dw_stress 1; engage 1.09; all 1.29; pulse 33.75; gap 30; wt 1.7000000000000002 | pre_dawn: maintain a small band-triggered recovery bridge wi |
Changed secondary parameters:
| Time | Parameter | Change |
|---|---|---|
| 16:47 | band_track_fraction | initial 0 |
| 16:47 | cold_vent_guard_delta_f | initial 15 |
| 16:47 | cool_stage2_exit_hysteresis_f | initial 1 |
| 16:47 | direct_wet_stress_min_dew_margin_f | initial 9 |
| 16:47 | direct_wet_stress_vpd_margin_kpa | initial 0.05 |
| 16:47 | dwell_gate_ms | initial 210000 |
| 16:47 | enthalpy_close | initial 1 |
| 16:47 | enthalpy_open | initial -2 |
| 16:47 | fog_escalation_kpa | initial 0.25 |
| 16:47 | heat_hysteresis | initial 1 |
| 16:47 | min_fog_off_s | initial 54 |
| 16:47 | min_fog_on_s | initial 66 |
| 16:47 | mist_backoff_s | initial 600 |
| 16:47 | mist_max_closed_vent_s | initial 600 |
| 16:47 | mist_thermal_relief_s | initial 90 |
| 16:47 | mister_all_delay_s | initial 75 |
| 16:47 | mister_engage_delay_s | initial 37.5 |
| 16:47 | mister_water_budget_gal | initial 300 |
| 16:47 | night_vpd_bias_kpa | initial 0 |
| 16:47 | outdoor_staleness_max_s | initial 600 |
| 16:47 | sw_dwell_gate_enabled | initial 1 |
| 16:47 | sw_fog_closes_vent | initial 1 |
| 16:47 | sw_mister_closes_vent | initial 0 |
| 16:47 | sw_summer_vent_enabled | initial 1 |
| 16:47 | temp_hysteresis | initial 1.6 |
| 16:47 | vent_exchange_fraction | initial 0.3 |
| 16:47 | vent_prefer_dp_delta_f | initial 10 |
| 16:47 | vent_prefer_temp_delta_f | initial 15 |
| 16:47 | vpd_watch_dwell_s | initial 52.5 |
Daily Summary So Far
Climate
58.5–85.1°F; avg 68.2°F
0.53–1.44 kPa; avg 0.94 kPa
47.6–74.9%
Interior Light Evidence
- Crop DLI: unavailable
- Reason:
source_reading_missing - Provenance:
par_quantum_sensor_canopy - Validity:
dli-validity-v2-par; 2026-11-08T07:57:55.927971+00:00 → open - Qualified-light minutes and photoperiod remain independent of unavailable DLI.
Stress Hours
- Heat stress (above the served band): 0.0h
- VPD stress (above the served band): 0.0h
- Cold stress (below the served band): 1.7h
Economics
USD 4.36
USD 2.38
Not available
Not available
Equipment Runtimes
| Equipment | Runtime | Reading |
|---|---|---|
| Fan 1 | 35 min | Primary exhaust runtime. |
| Fan 2 | 36 min | Secondary exhaust runtime. |
| Vent | 71 min | Intake vent runtime. |
| Fog | 6 min | Fogger runtime. |
| Heat 1 electric | 1047 min | Electric heater runtime. |
| Heat 2 gas | 229 min | Gas heater runtime. |
| Grow lights | 1151 min | Supplemental lighting runtime. |
| Mister south | 0.00h | South mister runtime. |
| Mister west | 0.00h | West mister runtime. |
| Mister center | 0.00h | Center mister runtime. |
Water
- Total: 49 gal
- Mister: — gal
Crop Health (Gemini Vision)
| Crop | Zone | Health | Observations | Note |
|---|---|---|---|---|
| Vanda Orchids | center | 78% | 4 | Observation notes are collapsed below to avoid publishing partial vision snippets. |
Vision observation notes
Plants appear healthy with green foliage and active root systems visible. No signs of stress or disease. || Plants appear turgid and healthy; no visible signs of stress or damage. || [fallen petals on floor] Plants appear generally healthy with green foliage; some fallen petals observed on floor indicating recent bloom or natural shedding. || [fallen petals on floor] Plants appear healthy with green foliage and active root systems visible. Fallen petals suggest recent blooming or minor handling stress, not systemic issue.
Hourly Pattern
| Hour | Temperature | VPD | RH |
|---|---|---|---|
| 10:00 | 73.1°F | 1.01 kPa | 64.7% |
| 11:00 | 76.2°F | 1.09 kPa | 65.8% |
| 12:00 | 76.2°F | 1.09 kPa | 65.7% |
| 13:00 | 77.3°F | 1.08 kPa | 66.7% |
| 14:00 | 79.6°F | 1.16 kPa | 66.5% |
| 15:00 | 81.3°F | 1.16 kPa | 69.0% |
| 16:00 | 74.6°F | 0.88 kPa | 70.4% |
| 17:00 | 72.0°F | 0.86 kPa | 68.3% |
| 18:00 | 71.8°F | 0.94 kPa | 65.4% |
| 19:00 | 69.3°F | 0.85 kPa | 65.8% |
| 20:00 | 66.4°F | 0.75 kPa | 66.8% |
| 21:00 | 64.2°F | 0.67 kPa | 68.0% |
| 22:00 | 64.0°F | 0.73 kPa | 64.4% |
| 23:00 | 63.1°F | 0.81 kPa | 59.7% |
| 00:00 | 61.6°F | 0.75 kPa | 60.3% |
| 01:00 | 61.4°F | 0.77 kPa | 59.3% |
| 02:00 | 61.4°F | 0.77 kPa | 59.3% |
| 03:00 | 60.8°F | 0.76 kPa | 58.5% |
| 04:00 | 61.5°F | 0.79 kPa | 58.2% |
| 05:00 | 62.8°F | 0.81 kPa | 59.5% |
| 06:00 | 63.8°F | 0.85 kPa | 58.9% |
| 07:00 | 65.2°F | 0.71 kPa | 67.4% |
| 08:00 | 68.4°F | 0.94 kPa | 61.5% |
| 09:00 | 69.0°F | 0.91 kPa | 63.5% |
7-Day Stress Context
| Date | Heat | VPD high | Cold |
|---|---|---|---|
| 2026-11-10 | 0.0h | 0.1h | 0.8h |
| 2026-11-11 | 0.0h | 0.0h | 0.3h |
| 2026-11-12 | 0.0h | 0.1h | 0.4h |
| 2026-11-13 | 0.0h | 0.0h | 0.4h |
| 2026-11-14 | 0.0h | 0.0h | 1.1h |
| 2026-11-15 | 0.0h | 0.2h | 1.5h |
| 2026-11-16 | 0.0h | 0.0h | 1.7h |